• 제목/요약/키워드: Cleaning Container

검색결과 25건 처리시간 0.02초

Acoustic Analysis of High-Frequency Ultrasonic Cleaner

  • Choi, Sunghoon;Kim, Jin Oh;Kim, Yong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제16권1E호
    • /
    • pp.49-56
    • /
    • 1997
  • Ultrasonic cleaning at high frequency around 1 MHz, called megasonic cleaning, is commonly used to remove particles less than 1 ㎛ by generating high frequency accelerations on the cleaning objects. Cleaning is performed in an ultrasonically-excited liquid contained in a double-structured container. Ultrasonic waves generated by piezoelectric transducers propagate in the outer container and are transmitted through the inner container. The bottom of the inner container is inclined to make oblique incidence of the ultrasonic wave in order to raise the efficiency of the transmission through the bottom plate. This work deals with the efficiency of the transmission, which directly affects the cleaning performance. The transmission characteristics of the ultrasonic wave in the megasonic cleaner have been obtained analytically and numerically for the variations of some parameters, such as the thickness and inclined angle of the bottom plate of the inner container and the chemical ratio and temperature of the cleaning liquid. The calculated results have yielded the optimum cleaning condition in terms of the sound power transmitted into the cleaning liquid.

  • PDF

청소 로봇을 위한 경로 계획의 새로운 알고리즘 (A New Algorithm for Complete Coverage Path-Planning of Cleaning Robots)

  • 유강;손영익;김갑일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.252-254
    • /
    • 2005
  • Completer coverage path planning requires the robot path to cover every part of the workspace, which is an essential issue in cleaning robots and many other robotic applications such as vacuum robots and painter robots. In this paper, a novel Water Flowing Algorithm (WFA) is proposed for cleaning robots to complete coverage path planning in unknown environment without obstacles. The robot covers the whole workspace just like that water fills up a container. First the robot goes to the lowest point in the workspace just like water flows to the bottom of the container. At last the robot will come to highest point in the workspace just like water overflows from the container and simultaneously the robot has covered the whole workspace. The computer simulation results show that the proposed algorithm enable the robot to plan complete coverage paths.

  • PDF

초음파검사용 젤 용기의 제균을 위한 세척방법 평가 (Evaluation of Washing Method for Sterilization of Gel Container for Ultrasound Inspection)

  • 이희정;이석준;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.241-247
    • /
    • 2018
  • The purpose of this study was to compare the ultrasound gel container washing methods for the sterilization of contaminants and to find the useful methods for the prevention of infection caused by the ultrasonic gel containers. In this experiment, a 250 mL ultrasonic gel container was used, and the ultrasonic gel used was a non-sterile gel (ECO GEL 99, SeungWon Medical, Korea). In order to evaluate the degree of contamination, new 250 mL 15 containers were divided into 5 groups to perform five types of washing by no treatment, washing with water, washing with soap, washing with bottle cleaner and high disinfection level washing. After the washing process, filled the gel container with gel and after 2 weeks, the number of colonies in the gel container was sampled repeatedly twice in the same ultrasonic laboratory and compared before and after washing. As a result of among the five cleaning methods used in this study, 87.2% and 88.9% of the soapy water washing (p = 0.028) and high level washing (p = 0.027) showed significant bacterial reduction rates, respectively. Our findings conclusively an ultrasonic gel container cleaning method for removing contaminants has been found to be an effective sterilization method at a low cost with a soapy water cleaning method. Therefore, it is expected that it will be helpful to prevent the infection caused by the ultrasonic gel container by suggesting the sterilization cleaning method that is practically useful in this study.

고주파 초음파 세정기의 파동 해석 (Acoustic waves in a high-frequency ultrasonic cleaner)

  • 최성훈;김진오;김용훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.656-661
    • /
    • 1997
  • Ultrasonic cleaning at high frequency near 1MHz, called megasonic cleaning, is commonly used to remove particles less than 1.mu.m by generating accelerations on them. Ultrasonic waves generated from piezoelectric transducers are transmitted through a non-metallic inner container which is used to isolate a cleaning object from metallic ions. The transmission characteristics of a double-structured megasonic cleaner on the variations of parameters such as the thickness and oblique angle of a inner container, chemical ratio of a cleaning agent and temperature and transmittivity are investigated. The results are used to determine an optimum cleaning condition.

  • PDF

관 내 세정을 위한 초음파 음장 연구 (A Study on Ultrasonic Sould-fields for Cleaning in a Pipe)

  • 이정구;김진오
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.564-570
    • /
    • 2005
  • This paper presents some results of research for applying ultrasonic cleaning to an interior wall of cylindrical pipe. As the cleaning is achieved better for higher sound pressure, ultrasonic sound field in a cylindrical container is considered. The paper identifies nonuniform sound field established by the radiation of a cylindrical transducer driven at resonant frequency, Numerical analysis predicts the sound pressure distribution, and experiment verifies the trend of analysis results. Experiment observes the cleaning effect, and this paper suggests the possibility of using a cylindrical ultrasonic cleaning device.

음선 기법을 이용한 초음파 음장 해석 (Ultrasonic Field Analysis Using a Sound-Ray Method)

  • 문병환;김진오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1329-1334
    • /
    • 2001
  • This paper deals with the application of a sound-ray method to the analysis of the sound field in an ultrasonic cleaner. In order to include the wave interference phenomenon, the method has been modified to consider the phase of sound rays, The improved algorithm has been implemented by developing a Visual C++ program, The algorithm has been verified by comparing the analysis results of BEM reported earlier. It has been shown that the algorithm can be used to calculate ultrasonic fields in a cleaning- container with an object to be cleaned.

  • PDF

Discussions on Availability of Weather Information Data and Painting Effect of Existing 8,600 TEU Container Ship Using Ship Performance Analysis Program

  • Shin, Myung-Soo;Ki, Min Suk;Lee, Gyeong Joong;Park, Beom Jin;Lee, Yeong Yeon;Kim, Yeongseon;Lee, Sang Bong
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.377-386
    • /
    • 2020
  • This paper discusses the effectiveness of onboard measurements and data extracted from weather information for speed-power analysis. Furthermore, validation results of hull and propeller cleaning and painting during dry-docking are discussed. Wind and wave information can be obtained from onboard measurements or weather information from the National Oceanic and Atmospheric Administration (NOAA). The weather information of a specified position and time is extracted from NOAA weather data and compared with onboard measurements. In addition, to validate the effects of hull cleaning and painting during dry-docking, speed-power analysis results of before and after dry-docking are compared. The results show that both onboard measurements and weather information show acceptable reliability when added resistance and speed-power analysis results are compared with each other. Moreover, the ship performance analysis (SPA) software clearly shows the effects of hull cleaning and painting, and it can provide reliable analysis results with either onboard measurements or weather information. In conclusion, it is confirmed that the analysis method and SPA software used in this study are effective in analyzing the ship's speed-power performance.

수중세척 전후 속도 성능 고찰 (The Study of Speed Performance as Implement of Underwater Cleaning)

  • 조원호;방영배
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2009년도 특별논문집
    • /
    • pp.35-39
    • /
    • 2009
  • The fouling around the surface of hull and propeller caused by marine organism and sea water occur in the vessel which is taken up mooring in a quay for a quite long time. Moreover, those are able to give rise to the loss of speed performance. The purpose of underwater cleaning is to improve the performance of vessel and customer satisfaction through management for fouling condition of propeller and hull. Therefore, systematic approach in connection with underwater cleaning is required so as to obtain the stable speed performance. As a result, we evaluate the effect of propeller polishing to speed performance from the case of 115K COT and 4,250 TEU Container Ship. In addition, we issue the importance of underwater cleaning through comparison of speed results depending on conditions of hull surface painted by silicon.

  • PDF

컨테이너 내륙운송에 있어서 운전기사에 대한 컨테이너 관리의 전가문제에 대한 고찰 (A Study on the Transfer of Container Management Responsibilities to Drivers in the Inland Transportation of Containers)

  • 이하연;조찬혁
    • 한국항만경제학회지
    • /
    • 제38권2호
    • /
    • pp.69-80
    • /
    • 2022
  • 우리나라에서 화물 수송분담율을 가장 많이 차지하는 것이 도로운송이다. 도로 컨테이너 운송은 컨테이너 운송의 출발점이자 완결점일 뿐만 아니라 매우 복잡하고 종사자 또한 많다. 육상물류에서 핵심 역할을 하고 있는 컨테이너 운전기사의 본업은 컨테이너를 항만 및 터미널에서부터 목적지까지 운송해 주는 것이다. 그러나 운송과정에서 컨테이너의 청소 및 데미지 컨테이너의 관리 등 본업외에도 여러 가지 컨테이너 관리의무를 묵시적으로 전가받고 있는 실정이다. 그러나 동 사안에 대해서는 그동안 거의 연구가 되고 있지 않은 상황이다. 본 연구는 컨테이너 운전기사의 근로환경에 대해 파악하고, 컨테이너 관리 작업에 대한 실태와 현황을 실증적으로 분석했다. 나아가 선사, 터미널, 화주별로 컨테이너 관리 요구 정도의 차이가 있는지 분석하는 한편 조사지역별 요구사항의 차이를 분석하고, 컨테이너 관리 전가문제에 대한 개선방안을 제시하였다.

살충제제(殺蟲製劑)의 안정성(安定性)에 관(關)한 연구(硏究) (Studies on the Stabilities of Insectcides Combined with some Stabilizers)

  • 우종학;김재완
    • Journal of Pharmaceutical Investigation
    • /
    • 제1권1호
    • /
    • pp.101-108
    • /
    • 1971
  • The stability and toxicity test for p.p'-DDT, DDVP and dipterex that put to used sample in this study effects is follows A. about p.p'-DDT (1) In elevating the stability of p.p'-DDT, best stabilizing solvent was benzene. (2) The stability-agent has no difficulty as long as it not contain metal ion for instance $Z_n^{2+}$,$C_r^{3+}$,$Al^{3+}$,and $Fe^{2+or3+}$ but in case of contain $F_e^{3+}$, the combination of salicylaminoguanidine is best effective. (3) Using this product for water-suspension, We must use span 40 for stability agent and adding it at the same time. (4) We must use container which does not week alkali and metal ion but it is to preserved in tight light-resistant container. (5) The stopper of container is adapted with above-mentioned condition of container, but it is better not to use metal material. (6) This product needs opening ventilation more than 30 minutes after diffusion or spray and in the room we remove cause of remained poison by cleaning the bottom. B. about DDVP and Dipterex (1) Benzene or toluene in best solvent to preserve stability of DDVP and Dipterex. (2) Span 40 is superior for stability agent of this product and second is span 80. (3) The pH of solution is very stable in pH 5-6 and comparative stable in alkali more than p,p'-DDT. (4) Container is to preserved in tight, lightresistant container and especially be careful of outflow and inflow of water. (5) Because this product is centeral stimulant poison, we must pay attention to prevent cause of contact diadermic toxicity after use.

  • PDF