• Title/Summary/Keyword: Clean water

Search Result 1,007, Processing Time 0.029 seconds

Supercritical Water Gasification of Low Rank Coal with High Moisture Content (고함수 저등급 석탄의 초임계수 가스화 특성)

  • Yoon, Sang Jun;Lee, Jae Goo;Ra, Ho Won;Seo, Myung Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.4
    • /
    • pp.340-346
    • /
    • 2013
  • Study on clean and efficient utilization technology for low rank coal with high moisture content is actively ongoing due to limited reserves of petroleum and of high grade coal and serious climate change caused by fossil fuel usage. In the present study, supercritical water gasification of low rank coal was performed. With increasing reaction temperature, content of combustible gases such as $H_2$ and $CH_4$ in the syngas increased while the $CO_2$ content decreased. As the reaction pressure increased from 210 to 300 bar, the $CO_2$ content in the syngas increased while the hydrocarbon gas content decreased. The $H_2$ and $CH_4$ content in the syngas increased slightly with pressure. With the addition of Pd, Pt, and Ru catalysts, it was possible to improve the production of $H_2$. Moreover, the increase of active metal content in the catalyst increased the $H_2$ productivity. The Ru catalyst shows the best performance for increasing the $H_2$ content in the syngas, while decreasing the $CO_2$ content.

An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구)

  • Kim, Ki-Cheol;Kim, Hyung-Tae;Song, Gen-Soo;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

Development of Analytical Method and Monitoring of Organophosphorus Pesticides in the Raw Water and Clean Water by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS를 이용한 유기인계 농약류의 최적 분석법 정립과 원·정수에서의 모니터링)

  • Kim, Gyung-A;Song, Mi-Jeong;Yeom, Hoon-Sik;Son, Hee-Jong;Lee, Sang-Won;Choi, Jin-Tack
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1569-1582
    • /
    • 2015
  • The analytical method for 16 organophosphorus pesticides was developed in this study. The 16 organophosphorus pesticides were analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) using on-line solid phase extraction (on-line SPE) with PLRP- S cartridge. Analysis of all analytes in the MS/MS was processed in the electrospray ioni-zation (ESI) positive mode. They are Azinphos ethyl, Chlorfenvinphos, Ethion, Famphur, Phosmet, Phosphamidon, Terbufos, Aspon, Chlorpyrifos-methyl, Crotoxyphos, Dichlofenthi-on, Dicrotophos, Fonofos, Thionazin, Dimethoate and Iprobenfos. Limits of detection (LODs) and Limits of quantification(LOQs) were obtained as 0.8~2.0 ng/L and 2.6~6.4 ng/L, respectively. All compounds were not detected at the 8 sampling points of the raw water and clean water.

Comparative Studies on K2CO3-based Catalytic Gasification of Samhwa Raw Coal and Its Ash-free Coal (삼화 원탄과 무회분탄의 촉매(K2CO3) 가스화 반응성 비교 연구)

  • Kong, Yongjin;Lim, Junghwan;Rhim, Youngjoon;Chun, Donghyuk;Lee, Sihyun;Yoo, Jiho;Rhee, Young-Woo
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.218-225
    • /
    • 2014
  • Catalytic gasification of raw coals at mild condition is not realized yet mainly due to deactivation of catalysts via their irreversible interaction with mineral matters in coal. In this work, the gasification behavior of ash-free coal (AFC) was compared with that of the parent raw coal. In order to modify the gasification conditions, the raw coal gasified with fixed variables (water supply, space velocity, temperature, catalysts) in a fixed bed reactor. When catalysts are added by physical mixing method with coal, $K_2CO_3$ was the most effective additives for steam gasification of coal. However, the activity of ash-free coal (AFC) was much less reactive than raw coal due to high temperature extraction in a 1-methylnaphthalene under 30bar at $370^{\circ}C$ for 1 h, almost removed oxygen functional groups, and increased carbonization. The addition of $K_2CO_3$ in AFC achieved higher conversion rate at low temperature ($700^{\circ}C$). At that time, the molar ratio of gases ($H_2/CO$ and $CO_2/CO$) was increased because of water-gas shift reaction (WGSR) by addition of catalysts. This shows that catalytic steam gasification of AFCs is achievable for economic improvement of gasification process at mild temperature.

A Study on the Performance Improvement of the Air Washer System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 시스템의 성능개선을 위한 연구)

  • Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3413-3417
    • /
    • 2007
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from the outdoor air introduced into clean room. In the present study, an experiment was carried out to examine the improvement of removal efficiency for the gaseous contaminants. In order to improve the gas removal efficiency, a hot water contact heat exchanger was installed upstream of the air washer to heat and humidify the incoming outdoor air before entering the air washer.

  • PDF

An Experiment on Performance Evaluation of a Vapor Condensation Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 수증기 응축식 에어와셔 시스템의 성능평가)

  • Yeo, Kuk-Hyun;Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.442-447
    • /
    • 2006
  • In semiconductor manufacturing clean rooms, it becomes important to remove airborne molecular contaminants as well as particulate contaminant in outdoor air introduced into clean rooms. One suitable control technique for these chemical contaminants is air washing by water in an outdoor air handling unit. In order to enhance the removal efficiency of chemical contaminants the effect of adding a heating and humidifying process before an air washer was examined.

  • PDF

Determination of Antibiotic Residues: I. Extraction and Clean-up Methods for Solid Samples_A Review (시료 중 잔류 항생제 분석 방법: I. 고상 시료 전처리 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.600-627
    • /
    • 2016
  • Korea is one of the countries with a large veterinary antibiotics market, although antimicrobial resistance in bacteria is becoming a serious issue in many countries. The Korean government started to take interest in estimating the effects of livestock manure on rivers and agricultural soils and in monitoring of heavy metals, organic pollutants and antibiotics in the ambient water and soil. In this paper, pre-treatment methods to separate the selected antibiotics from solid samples were reviewed. It is essential to select an efficient and appropriate procedure for pre-treatment due to the high proportion of proteins and organics in biosolid samples. Pre-treatment consists of extraction followed by clean-up. Initially, homogenized samples were extracted by sonication, mechanical agitation or pressurized liquid extraction with methanol/acetonitrile/water mixture under acidic/basic conditions depending on the compound. However, aminoglycosides and colistin were extracted with 5% trichloroacetic acid and HCl, respectively. Since the ${\beta}-lactams$ are easily decomposed in acidic and basic conditions, they were extracted in neutral pH. Filtration with a membrane (pore size, $0.2{\mu}m$) or solid phase extraction with HLB and methanol, as eluents, was normally applied for the clean-up. At least, three different pre-treatment procedures should be adopted to screen all the selected antibiotics in solid samples.

A new cleaning concept for display process with electrolyzed anode water (전해 양극수를 이용한 디스플레이 신 세정 공정)

  • Choi Minki;Cha Jiyung;Kim Younggeun;Ryoo Kunkul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.99-102
    • /
    • 2004
  • Display process has adopted RCA clean, being applied to large area and coped with environmental issue for last ten years. However, the approaching concept of ozonized, hydrogenised, or electrolyzed water cleaning technologies is within RCA clean paradigm. In this work, only electrolyzed anode water was applied to clean particles and organics as well as metals based on Pourbaix concept, and as a test vehicle, MgO particles were introduced to prove the new concept. The electrolyzed anode water is very oxidative with high oxidation reduction potential(ORP) and low in pH of more than 900mV and 3.1, respectively. MgO particles were immerged in the anode water and its weight losses due to dissolution were measured with time. Weight losses were in the ranges of 100 to 500 micrograms in 250m1 anode waters depending on their ORP and pH. Therefore it was concluded that the cleaning radicals in the anode water was at least in the range of 1 to 5E20 ea per 250 ml anode water equivalent to IE18 ea/cm3. Hence it can be assumed that the anode water be applied to display cleaning since 1E10 to IE15 ea/cm3 ranges of contaminants are being treated. In addition, it was observed that anode water does not develop micro-roughness on hydrophobic surface while it does on the native silicon oxide.

  • PDF

Water is Hold Your Health (물이 당신의 건강을 좌우한다)

  • 구광서
    • Journal of the Korean Professional Engineers Association
    • /
    • v.35 no.4
    • /
    • pp.29-33
    • /
    • 2002
  • WATER, the best known and most abundant of all chemical compounds occurring in relatively pure form on the earth"s surface . And life, the material of which organisms are made by water and protoplasm. Especially, between human life and water must be joined by human"s protoplasm, proteins, nucleic acids cells energy exchange and anothers. Therefore. health of mankind is In according to drink enough clean water and to use good water environment.

  • PDF

A Study on environmental-friendly Cleaning for Si-wafers (환경친화적인 실리콘 웨이퍼 세정 연구)

  • Yoon, Hyoseob;Ryoo, Kunkul
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.79-84
    • /
    • 2000
  • In this study, to reduce the consumption of chemicals in cleaning processes, Si-wafers contaiminated with metallic impurities were cleaned with electrolyzed water(EW), which was generated by the electrolysis of a diluted electrolyte solution or ultra pure water(UPW). Electrolyzed water could be controlled for obtaining wide ranges of pH and ORP(oxidation-reduction potential). The pH and oxidation-reduction potential of anode water and cathode water were measured to be 4.7 and +1000mV, and 6.3 and -550mV, respectively. To analyze the amount of metallic impurities on Si-wafer surfaces, ICP-MS was introduced. Anode water was effective for Cu removal, while cathode water was more effective for Fe removal.

  • PDF