Parametric Study of 2.5 kW Class Propeller Type Micro Hydraulic Turbine (2.5 kW 급 프로펠러형 마이크로 수차 매개변수 연구)

  • MA, SANG-BUM;KIM, SUNG;CHOI, YOUNG-SEOK;CHA, DONG-AN;KIM, JIN-HYUK
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.4
    • /
    • pp.387-394
    • /
    • 2020
  • A parametric study of a 2.5 kW class propeller type micro hydraulic turbine was performed. In order to analyze the internal flow characteristics in the hydraulic turbine, three dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model were used and the hexahedral grid system was used to construct computational domain. To secure the reliability of the numerical analysis, the grid dependency test was performed using the grid convergence index method based on the Richardson extrapolation, and the grid dependency was removed when about 1.7 million nodes were used. For the parametric study, the axial distance at shroud span (L) between the inlet guide vane and the runner, and the inlet and outlet blade angles (β1, β2) of the runner were selected as the geometric parameters. The inlet and outlet angles of the runner were defined in the 3 spans from the hub to tip, and a total of 7 geometric parameters were investigated. It was confirmed that the outlet angles of the runner had the most sensitive effect on the power and efficiency of the micro hydraulic turbine.

A Study on the Space Program & Research of GMP in Domestic Institute for Life Science (국내 종합병원부설 생명공학연구소의 GMP 시설에 대한 실태조사 및 공간구성에 대한 연구)

  • Lee, Sang-Sok;Park, Jae-Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.13 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • The medicine is used for diagnosis, treatment or prevention of disease and consequently has an important influence upon human life and health. Its effectiveness and safety must be guaranteed. In order to achieve the facility that meets GMP, KFDA has provided standards for quality assurance of the manufacture, examination and tests of medical supplies. The result of this study were as follows : the GMP facilities are divided into work, lab/test and storage spaces, and the systematic corridor. The clean rooms are mainly installed in work and lab/test spaces, and maintain class 10,000 in average. The individual space for the procedures that requires class 100 is not provided as a separate division. Instead, they are performed in the clean bench of the laboratory.

  • PDF

SUMS OF TRIPOTENT AND NILPOTENT MATRICES

  • Abdolyousefi, Marjan Sheibani;Chen, Huanyin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.3
    • /
    • pp.913-920
    • /
    • 2018
  • Let R be a 2-primal strongly 2-nil-clean ring. We prove that every square matrix over R is the sum of a tripotent and a nilpotent matrices. The similar result for rings of bounded index is proved. We thereby provide a large class of rings over which every matrix is the sum of a tripotent and a nilpotent matrices.

Development of 2.5 kW Class Propeller Type Micro Hydraulic Turbine (2.5 kW 급 프로펠러형 마이크로 수차 개발)

  • MA, SANG-BUM;KIM, SUNG;CHOI, YOUNG-SEOK;CHA, DONG-AN;KIM, JIN-HYUK
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.3
    • /
    • pp.314-321
    • /
    • 2020
  • In this work, a preliminary design of an inlet guide vane and runner for developing a 2.5 kW hydraulic turbine was conducted by using computational fluid dynamic analysis. Three-dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model were used to analyze the fluid flow in the hydraulic turbine. The hexahedral grid system was used to construct computational domain, and the grid dependency test was performed to obtain the optimal grid system. Velocity triangle diagram considering the flow angles of the inlet guide vane and runner was analyzed to obtain a basic geometry of the inlet guide vane and runner. Through modification of the preliminary design, the hydraulic performances of the turbine have improved under overall drop conditions. Especially, the efficiency and power of the turbine increased by 0.95% and 1.45%, respectively, compared to those of the reference model.

A Study on the Characteristic of Field Operation of Wind farm at Hangwon, Cheju (제주 행원 풍력 단지 실부하 운전 특성 연구)

  • Oh, Si-Doek;Cha, Jong-Hwan;Lee, Hyun-Joo;Huh, Jong-Cheul
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.744-750
    • /
    • 2001
  • In now a days, the concern to environment and energy saving problem is increased worldly. So many countries are developing the wind power system as clean energy system. In our country, Cheju local government has the plan of the Cheju Island wind farm and 600kW class 2 wind turbines, 660kW class 2 turbines, 225kW class 1 turbine and 750kW class 2 turbines has been operated at Hangwon. In this paper the field operation data of the wind turbines was analyzed and was compared with the characteristics & performance of each turbines. As the results, we would find the possibility of wind turbine in domestic and suggest the direction of developing technology.

  • PDF

Detection and Synthesis of Transition Parts of The Speech Signal

  • Kim, Moo-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3C
    • /
    • pp.234-239
    • /
    • 2008
  • For the efficient coding and transmission, the speech signal can be classified into three distinctive classes: voiced, unvoiced, and transition classes. At low bit rate coding below 4 kbit/s, conventional sinusoidal transform coders synthesize speech of high quality for the purely voiced and unvoiced classes, whereas not for the transition class. The transition class including plosive sound and abrupt voiced-onset has the lack of periodicity, thus it is often classified and synthesized as the unvoiced class. In this paper, the efficient algorithm for the transition class detection is proposed, which demonstrates superior detection performance not only for clean speech but for noisy speech. For the detected transition frame, phase information is transmitted instead of magnitude information for speech synthesis. From the listening test, it was shown that the proposed algorithm produces better speech quality than the conventional one.

A Study on Clean Agents for Halon Replacement in the Portable Extinguisher with CO2 as an Expellant Gas (이산화탄소를 가압원으로 하는 할론대체 소화기용 청정소화약제에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • To prevent ozone depletion caused by CFCs, the replacement of Halon with clean agents has been developed in the fire protection field along with refrigerants, detergents, and foaming agents. The alternatives for Halon 1211 have been developed in the portable fire extinguisher area and HCFC-123 is used widely as a clean fire extinguishing agent. The type of expellant gas is important because their own vapor pressure is low. In this study, HCFC-123, HCFC-124, HFC-125, and Novec-1230 were selected as fire extinguishing agents and CO2, which is expected to improve the fire extinguishing ability, was chosen as the expellant gas. For each agent, experiments changing the agent and CO2 amount were carried out and HCFC-123 showed a good result, as expected. The extinguisher, HCFC-123 of 1.5 kg, showed the same ability to suppress a class A and B fire as the extinguisher, HCFC-123 of 2.5 kg, which is currently sold on the market. According to this result, the expellant gas has a subsidiary fire extinguish effect. This can reduce the amount of HCFC fire extinguishing agent, which is categorized in the phase-out alternatives, and is a more eco-friendly and economical fire extinguisher than the previous one. This study can also help solve the problems of CO2 fire extinguishers for class B and C fires, and can be used to extinguish electric and electron facilities fire, which contains large amounts of class A fire combustibles.

A study on the various operating methods of 100kW class PV-SPE system (100kW급 대용량 PV-SPE 시스템의 운전방법에 관한 연구)

  • Lee, Seok-Ju;Lee, Dong-Han;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1167-1168
    • /
    • 2006
  • Recently, the concern for environmental issue has been rising in the world such as global warming and breaking of ozone barrier by exhausting carbon dioxide(CO2) and Freon. In this situation, Photovoltaic(PV) and hydrogen energy system for utilizing clean and renewable energy was highlighted to contribute very much against the global warming prevention. Until now, authors have studied EMTDC model Development of Solar-powered Hydrogen production system and manufactured the 600W class actual PV-SPE system. Which was established in 2004 to produce highly pure hydrogen energized by PV power generation system. Sooner, authors will establish 100kW class PV-SPE system. Economically, this system produce large amount of hydrogen. In this paper, all data of 100kW class PV-SPE system will be simulated by using PSCAD/EMTDC.

  • PDF

Assessment of Atmospheric Corrosivity at Jeju Island (제주도 대기환경의 부식성 평가)

  • KIM GUI-SHIK;YANG KYEONG-CHO;HU CHUL-GOO;SONG JEONG-HWA
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.50-57
    • /
    • 2005
  • This study has been conducted to investigate corrosivity of carbon steel, Cu, Zn and Al for one year from Sept. 2003 to Aug. 2004. A model of ISO 9223-ISO 9226 that represents the relation between metal corrosions and environmental parameters was used for atmospheric corrosion evaluations. Environmental parameters for these evaluations are time of wetness(TOW), $SO_2$ and Chloride. Corrosion rates for four metals which are exposed indoors and outdoors were measured on five locations in Jeju Island; Gosan, Seogwipo, Seongsan, Chuna hill and Jeju city. The environmental factor of atmospheric corrosion of Jeju Island for $SO_2$ class is P0, a clean area. TOW as T3 and T4 indicates that Jeju has the characteristics of a tropical area. Chlorides class within 3 km from the coast show the features of costal area as S2 and S3 classes. Chuna hill show the features of woodland as a S1 class. In Corrosion classes of each site which was measured outdoors is higher than indoors. Gosan is the highest class as the rank of C5, and indicated that they're ranked as C3 or C4.