• Title/Summary/Keyword: Circulation Point

Search Result 278, Processing Time 0.027 seconds

Analysis of Non-Point Source Pollution Reduction using Water Sensitive Urban Design in Gimhae, South Korea (김해시 물 순환 개선 도시계획에 의한 비점오염물질 저감효과 분석)

  • Jung, Kang-Young;Kim, Shin;Kwon, Hun-Gak;Yang, Duk Seok;Kim, Kyosik;Jang, Kwang-Jin;Shin, Dong-Seok;Ahn, Jung-Min
    • Journal of Environmental Science International
    • /
    • v.25 no.11
    • /
    • pp.1499-1509
    • /
    • 2016
  • This study was performed to analyze the effects of a water circulation green area plan on non-point source pollution in Gimhae South Korea. A quantitative analysis of Arc-GIS data was conducted by applying a watershed model based on Fortran to investigate the changes to direct runoff and pollution load. Results showed that prior to the implementation of the water circulation green area plan in Gimhae, direct runoff was $444.05m^3/year$, total biological oxygen demand (BOD) pollution load was 21,696 kg/year, and total phosphorus (TP) pollution load was 1,743 kg/year. Implementation of the development plan was found to reduce direct runoff by 2.27%, BOD pollution load by 1.16% and TP pollution load by 0.19% annually. The reduction in direct runoff and non-point source pollution were attributed to improvements in the design of impermeable layers within the city.

A Study on the Currency circulation of Myeong-do-Jeon in Gojoseon

  • SEO, Jung-Hwa;YOUN, Myoung-Kil
    • Journal of Koreanology Reviews
    • /
    • v.1 no.1
    • /
    • pp.37-49
    • /
    • 2022
  • The purpose of this study is to discuss how Dongi People in ancient societies resided in the region including the Korean Peninsula shaped its economy, what kind of currency was used, and their economic activities using this currency. This study started from a skeptical point of view that the Dongi People were conducting economic activities with the currency used in the country made by the Jina People before and after the Gojoseon society. Currently, in China, all currencies issued in China are treated as their own currency. It is due to subjective interpretation from a nationalist point of view. Japan subjectively interprets and judges from a Japanese point of view and North Korea judges from the central point of view on the Korean Peninsula. This difference is due to the subjective interpretation from the researcher which has been affected by their associating academic area. This has caused the lack of objectivity. In other words, it means that there is a big difference in the perception of the interpretation of history between different academic areas. This study, therefore, tried to avoid the application of biased concept or academic research in order to define the distribution economics more objectively by conducting the study based on the literature sources from Chinese ancient books and field research materials as much as possible, as the study and research conducted based on the domestic sources are insufficient in the sense that there is a gap between different perceptions and interpretations. As a conclusion of this study, the excavation area of Myeong-do-jeon is perfectly consistent with the old river area of Gojoseon, and in particular, considering Gojoseon was in the hostile relationship with Yan, it was found that only Myeong-do-jeon was used without using any other Chinese currency in the entire Gojoseon area, not just some areas. It is also a decisive clue to prove that it is not the Yan currency. The limitation of this study in developing the discussion different from the current research and study is that there was a lack of exploration and investigation of various documents and relics. For future research, this study will become more meaningful when it is conducted simultaneously with the discovering of new documents as well as the relics.

A Study on Characteristics of Modern Museum Architecture's Visual Circulation - Focused on Space Syntax and Visibility Graph Analysis - (현대뮤지엄 건축의 시각동선(視覺動線) 특성에 관한 연구 - 공간구문론(Space Syntax)과 가시장분석(Visibility Graph Analysis)을 중심으로 -)

  • Park, Chong-Ku;Lee, Sung-Hoon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.4
    • /
    • pp.74-81
    • /
    • 2010
  • This study analyzed characteristics of visual circulation in the modern museum architecture while carrying out space syntax and visibility graph analysis side by side in order to solve problems of visitors' movement having been suggested as the point at issue at modern museum architecture that has become big scaled and layering so as to satisfy various social demands. Also, the result of this analysis is same as followings. First, visitors become to watch the exhibition with clear position that can make themselves in right allocation, and thus visual and perceptual confusions were shown as relatively low in case physical position and visual one were matched at major space of atrium type or mediation space. Second, it was appeared a lot at the museum having exhibition space of room type in case the physical position and visual one were not matched. Visual circulation in the exhibition space of room type has a merit of forming the circulation where free selection is possible. However, it have raised concerns that visual passageway of visitors could be in a stalemate or crash at the opening part, not at the exhibition hall. Third, though analysis of space syntax had a merit of analyzing total modern museum architectures having became compounded and big scaled, but it was dropped in reliability from the visual circulation's analysis that was decided by flows of space and time. In contrary, visibility graph analysis was shown as having a merit to analyzing the flows rather than that of total structure, and also appeared as being able to supplement the disadvantage of space syntax in methodology. Upon the above analysis, a lot of architectural elements such as allocation of exhibition hall, location of door and window etc. were appeared as affecting influences to forming visual circulation of visitors, not to mention of allocations of major space, mediation space, and exhibition one. Through this study, various possibilities of quantitative analysis on the visual circulation in the museum architectures can be confirmed. However, this study expects that in-depth subsequent researches objecting to various museums could be realized afterwards because there are still limitations in its analysis.

A Study on Frank Gehry's Architectural Changes After the Art Gallery of Ontario (온타리오 미술관 이후 프랭크 게리의 건축적 변화 연구)

  • Lee, Jae-In
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.95-106
    • /
    • 2018
  • This study aimed at revaluating Frank Gehry's freeform constructions. To this end, the study analyzed the way the space composition and circulation system of general constructions are connected with newly extended parts in the Art Gallery of Ontario and, based on this, comparatively analyzed freeform constructions before and after the art gallery, finding out what changes were made in the exterior and interior spaces of freeform constructions built after the art gallery. The results of the study are as follows. First, starting from extending the Art Gallery of Ontario, Gehry came to use glass instead of metal as main material of freeform constructions. In order to create the circulation connecting the existing building and the extended mass, Gehry applied continuing circulation for the first time to the gallery. Third, in addition to design motives, such as the woodblock print depicting a carp by Hiroshige, still life depicting a glass bottle by Morandi and the crease of the shawl in Vermeer's paintings, which Gehry applied to freeform constructions, the design motif which was recently acquired from Pyrenees rock was added. Fourth, the trend of mall construction appeared before and after the Art Gallery of Ontario. Finally, Gary used the shape of fish as a design motif for his work at an important turning point in his Freeform Architecture.

Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

  • Jongmin J. Lee;Yongmin Chang;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.91-97
    • /
    • 2000
  • Objective: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. Materials and Methods: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose timeintensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. Results: Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. Conclusion: Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

  • PDF

Freeze Protection for Passive Solar Water Heating System (자연순환형 태양열온수기 동파방지기술)

  • Kim, Jong-Hyun;Hong, Hi-Ki;Chung, Jae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.327-333
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and shortage of excessive electric power consumption. In the experimental device, hot water in storage tank was used to heat the outlet pipe from the tank if the pipe surface temperature falls lower than a set point. The cold water pipe to the storage tank was installed to directly contact the hot water pipe surface temperature rose by transferred heat.

K University History Exhibition Hall Interior Design (K 대학 역사전시관 실내디자인)

  • Kim, Jung-Shin;Lee, Jong-Se
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.11a
    • /
    • pp.197-198
    • /
    • 2006
  • The latest university makes the use of exhibition hall bring into relief a specific character and identity. This purpose of this design is to induce interest the exhibition plan, that is useful to appreciation of audience according to space structure. The concept of this design is to design continual circulation plan and to give correctness Information of the exhibit. Because to this exhibition hall is too small space, this design focus is continual circulation plan. The exhibit is classified to according to the character of that, which is distinguished according to the colour plan. The center of the hall is main image hall of university. The right space of the main hail is university history exhibition hall and the left space of the hall is a founder memorial hall. The main colour is light cream. An image object colour plan is point colou, which is bluish green colour.

  • PDF

Application of Model Based Predictive Control with Kalman Filter to Natural Circulation Water Tube Boiler

  • Kim, Tae-Shin;Kwon, Oh-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1146-1151
    • /
    • 2005
  • This paper deals with the control problem of a natural circulation water tube boiler with constraint conditions. Some linearized models for the water tube boiler are proposed around some operating points, and the model based predictive control law is adopted to control the plant accounting for constraints. In this controller, the Kalman filter is used for the state estimation, and the controller is designed based on the linearized model. The control performance of the designed controller is exemplified via some nonlinear simulations around the operation point, which show it works well.

  • PDF

A Study on the Transient Flow Process in a Vacuum Ejector-Diffuser System (진공 이젝터-디퓨져 시스템내의 비정상 유동 과정에 관한 연구)

  • Vincent, Lijo;Kim, Heuy-Dong;Setoguchi, T.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.299-302
    • /
    • 2009
  • The objective of the present study is to analyze the transient flow through theejector system with the help of a computational fluid dynamics (CFD) method. An attempt is made to investigate the interesting and conflicting phenomenon of the infinite entrainment into the primary stream without an infinite mass supply from the secondary chamber. The results obtained show that the one and only condition in which an infinite mass entrainment can be possible in such types of ejectors is the generation of a re-circulation zone near the primary nozzle exit. The flow in the secondary chamber attains a state of dynamic equilibrium of pressures at the onset of the recirculation zone. A steady flow in the ejector system is valid only after this point.

  • PDF

An Experimental Study on Vapor-Liquid Equilibria of HFC and HC Refrigerant Mixtures (탄화수소 및 불화탄화수소 혼합냉매의 기상-액상 평형에 관한 실험적 연구)

  • 강병복;김민수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1031-1037
    • /
    • 2000
  • Isothermal vapor-liquid equilibrium(VLE) data have been obtained for the systems of propane(R290)+1,1,1,2-tetrafluoroethane(R134a) and 1,1,1,2-tetrafluoroethane(R134a)+isobutane(R60A) in the temperature range of 253.15 to 323.15K. Experiments were performed in a circulation type apparatus by injecting vapor through liquid pool using a magnetic pump. Both systems form azeotropes in the temperature range of this study. The experimental results were estimated with the Peng-Robinson equation of state. When the temperature-dependent binary interaction parameter was used in the Peng-Robinson equation of state, the absolute average deviation of the measured bubble point pressures from the values correlated by the Peng-Robinson equation was 0.65% and 0.78% for R290+R134a and R134a+600a, respectively. Azeotropic compositions for both systems were presented.

  • PDF