• Title/Summary/Keyword: Circulation Point

Search Result 278, Processing Time 0.023 seconds

Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator (확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구)

  • 이현경;김선창;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF

A Study on Method of Selecting Five Su Point(五輸穴) According to the Turning of Season in "Hwangjenaegyeong(黃帝內經)" ("황제내경(黃帝內經)"의 사시별(四時別) 오수혈(五輸穴) 취혈법(取穴法)에 대한 소고(小考))

  • Kim, Jong-Hyun;Jeong, Chang-Hyun;Jang, Woo-Chang;Baik, You-Sang
    • Journal of Korean Medical classics
    • /
    • v.22 no.1
    • /
    • pp.121-130
    • /
    • 2009
  • Traditionally, Korean Medicine put emphasis on the treatment and health-preserve method that corresponds with circulation of nature. And acupuncture is no exception to this rule. In "Hwangjenaegyeong(黃帝內經)", some chapters present method that is changed according to the seasons. Among the chapters, there are some difference, but we can find a general theory. In spring, Yanggi(陽氣) is coming out but not strong and cannot diffuse. so the Yanggi(陽氣) hang up the middle of outer layer. Therefore, we can take some acupoints around the muscle interspace[分腠] or tiny branches of Meridian[孫絡]. In summer, Yanggi(陽氣) flourish and boil all around of the outer layer. So, we can take some acupunctural points from skin to the yang-meridian. In both fall and winter, five su point[五輸穴] make up almost of point. in fall, yanggi begin convergence. we can remove the Eum-pathogen[陰邪] and help the normal convergence by using Stream point[腧穴], River point[經穴] and Sea point[合穴]. In winter, Eum surround so solidly that the neo Yanggi(陽氣) cannot come out. So, we can break the yin by using Well point[井穴] and make be strong by Spring point[滎穴]. If we Study the method that correspond with the seasonal circulation more, we will be able to treat diseases more minutely.

  • PDF

A Study on Circulation System in conjunction with the multi-floored Art Museum - With reference to art museum in Europe - (미술계뮤지엄의 다층화에 따른 동선체계의 변화에 관한 연구 - 유럽 소재 뮤지엄을 중심으로 -)

  • Moon, Jung-Mook
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.107-116
    • /
    • 2010
  • In Europe, traditionally the low-rised buildings for public art museum have been constructed since the 18th century like any other buildings and these are because of the technical issue for construction difficulty. Even if the low-rised art museum buildings are still continued for it's construction, gradually the high-rised art museum buildings begin to be build due to the development of contemporary technology in high-dense modern urban space. This tendency of high-rised art museum building in recent years is expected to affect on the interior space of it and most of all the spatial change in conjunction with circulation system variation is remarkable. Because the circulation system in art museum means tourist's spatial experience and it normally controls the experience of knowledge in art museum. This study is to understand how the multi-floored art museums in Europe affect to the spatial structure and how this is related to the circulation system. And also the study raised an issue on what it's social meaning is. Through these analysis the study can provide the meaning of multi-floored art museum and basic indication in art museum planning. To understand this, the study calculated the number of stories, number of vertical circulation and number of ring-structure space. Also the study tired to use space syntax tools, which are connectivity, integration value, integration value in major space, integration value in vertical circulation and intelligibility value. those tools alculated topological transfiguration of the whole space.Throughout the study, it was concluded that the influence of high-rised art museum in Europe changed the spatial structure and circulation system. The topological center of art museum that has been the grand space since 18th century changed to the vertical circulation due to the it's roll of distributing visitors to each floor. It became a starting point of spatial deployment and experience in art museum.

Research of Flow Electrification Phenomena of the used Environment-Friendly Vegetable Insulating Oils (친환경 식물성절연유의 유동대전현상 연구)

  • Choi, Sun-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.580-584
    • /
    • 2012
  • The insulating oils perform a cooling and insulation action in electric power transformer. The mineral oil has immanent fire dangerousness and environmental contamination problem. Vegetable insulating oil has higher ignition point, flash point and more excellent biodegradability than conventional mineral oil. In a real oil-filled transformers, some of the power is dissipated in the form of heat. And transformer require the heat to be removed from the winding and insulator by forced convection of the insulating oil. The flow electrification occurs when insulating oil was forced to be circulated. In this paper, influence of temperature, velocity of flow, and insulating pipe and diameter on streaming electrification of vegetable insulating oil was investigated using forced circulation apparatus. Temperature effects were most significant, and it showed a peak in the temperature $30^{\circ}C$ to $35^{\circ}C$ at insulating and copper pipe. The change of flow electrification according to area variety could be checked by change of diameter.

A Study on the Relationship between Individual Knowledge Cycle Process on Its Knowledge Management Efficiency (기업내 개인차원에서의 지식순환과정과 지식경영 효율성간의 관계에 관한 연구)

  • Lee, Kun-Chang;Chung, Nam-Ho
    • Knowledge Management Research
    • /
    • v.3 no.2
    • /
    • pp.31-48
    • /
    • 2002
  • Recent trend of business is characterized by a recognition of importance of knowledge asset. Especially, this phenomenon is receiving more momentum as our society goes digital rapidly. However, most of literature on knowledge management is based on knowledge circulation from the corporate point of view, not from individual viewpoint. In this regard, this paper is concerned with proposing knowledge circulation process and its efficiency from the individual perspective. We adopted structural equation model or SEM to prove the statistical validity of our research framework. Eight hypotheses were built and tested empirically, leading to the fact that the knowledge utilization and sharing of individuals have a positive impact on the knowledge management efficiency.

  • PDF

POM/MICOM Inter-Comparison in Modeling the East Sea Circulation

  • Kim, Kuk-Jin;Seung, Young-Ho;Suk, Moon-Sik
    • Ocean and Polar Research
    • /
    • v.23 no.2
    • /
    • pp.161-172
    • /
    • 2001
  • A model-to-model comparison is attempted between Princeton Ocean Model (POM) and Miami Isopycnic Coordinate Ocean Model (MICOM) as a first step to extend our knowledge of models' performances in studying the East Sea circulation. The two models have fundamentally different numerical schemes and boundary conditions imposed on these models are not exactly the same each other. This study indicates that MICOM has a critical weak point in that it does not reproduce the shallow surface currents properly while it handles the thermohaline processes and associated movements of intermediate and deep waters efficiently. It is suggested that the mixed layer scheme needs to be modified so that it can match with inflow boundary conditions in order to reproduce the surface currents properly in MICOM. POM reproduces the surface current pattern better than MICOM, although the surface currents in POM appear to undergo the unrealistic seasonal variation and have exaggeratedly large vertical scale. These defects seem to arise during the process of adapting POM to the East Sea, and removing these defects is left as a future task.

  • PDF

HWR Shield Cooling Natural Circulation Study (원자로 차폐체 자연순환냉각에 관한 연구)

  • Shin, Jung-Chul
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.221-227
    • /
    • 2012
  • The CANDU 9 shield cooling system was designed and layout with the objective of promoting natural circulation on loss of forced flow. In the present study, the shield cooling natural circulation was analyzed using verified the thermal-hydraulic code when the coolant pump or the heat exchanger was lost. This study showed that thermosyphoning cooled the end shields and prevented the end shields and the reserve water tank from boiling for at least 8 hours on loss of the shield cooling pumps but the heat exchangers still operational. With the loss of both pumps and heat exchangers, the end shields remain subcooled for up to 4 hours. To enhance thermosyphoning, the bypass connection to the line from the reserve water tank should be relocated to a point as low as possible.

Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas (혹한기 지역에서의 자연순환형 태양열 시스템 동파방지)

  • Kwon, Jae-Wook;Kim, Jong-Hyun;Hong, Hi-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

A Study on the Evaluation of the Cognition of the Circulation Efficiency in Geriatric Hospital (노인요양병원 진료부의 경로인지 효율성 평가에 관한 연구)

  • Bae, Sun-mi;Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.6
    • /
    • pp.40-51
    • /
    • 2016
  • The aim of this study is to quantitatively deduce the circulation efficiency and space arrangements of the outpatient department in geriatric hospitals in terms of spatial structure and to find a methodology that could promote the improvement of accessibility and spatial cognition while using the facilities. All space units of the selected twelve geriatric hospitals were located on the first floor. The study adopted the psychological distance concept of space syntax to the unitized spaces, and presented a set of indices, such as TD, PN, RF, PNT and TRF. These indices were calculated according to the standard clinical use procedures. The study evaluated the effectiveness of circulation. The analysis of circulation was based on the four major geriatric illnesses that were selected in this study. The study established the standard clinical use procedure with consideration of the medical treatment, examinations and space units of outpatient departments. The results are as follows: 1) Based on the statistical data, four major geriatric illnesses are examined, and space requirement and standard procedures are established. Development indicators are applied in order to quantitatively deduce the efficiency of spatial cognition. 2) The percentage of the risk of cognitive decline(TRF) has an inversely proportional correlation to the circulation efficiency(PNT) at a certain point. TRF is more influenced by the clinical use procedure than the scale. 3) The arrangement of the waiting space and types of corridor greatly affect the percentage of the risk of cognitive decline. 4) Vulnerable facilities are selected on the basis of the evaluation, and two alternatives that could promote the circulation efficiency are presented. The result of the reanalysis showed that cognitive efficiency had much improved compared to the existing facilities.

Analysis on the Water Circulation and Water Quality Improvement Effect of Low Impact Development Techniques by Test-Bed Monitoring (시범 단지 운영을 통한 LID 기법별 물순환 및 수질개선 효과 분석)

  • Ko, Hyugbae;Choi, Hanna;Lee, Yunkyu;Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2016
  • Low Impact Development (LID) techniques are eco-friendly storm water management process for water circulation restoration and non-point pollutant reduction. In this study, four LID techniques (Small constructed wetland, Infiltration trench box, Infiltration trench, Vegetated swale) were selected and installed as a real size at the real site. All facilities were evaluated as monitoring under the real environmental climate situation and an artificial rain with exceeding design rainfall. In various rainfall, runoff reduction efficiency and non-point pollutant removal efficiency are increased to the bigger Surface Area of LID (SA)/Catchment Area (CA) ratio and the bigger Storage Volume of LID (SV)/Catchment Area (CA) ratio. Runoff did not occur at all rainfall event (max. 17.2 mm) in infiltration trench and vegetated swale. But Small constructed wetland was more efficient at less than 10 mm, a efficiency of infiltration trench box was similar at different rainfall. Although different conditions (such as structural material of LID, rainfall flow rate, antecedent dry periods), LID techniques are good effects not only water circulation improvement but also water quality improvement.