• Title/Summary/Keyword: Circulating fluidized Bed Combustion

Search Result 100, Processing Time 0.023 seconds

Circulating Fluidized Bed Combustion of Refuse Derived Fuel (폐기물 연료의 순환유동층 연소기술)

  • Shun, Do-Won;Bae, Dal-Hee;Lee, Seung-Yong;Jo, Sung-Ho
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.124-134
    • /
    • 2005
  • A new technology for refused derive fuel(RDF) utilization in circulating fluidized bed is under development. The RDF is tested in a bench scale circulating fluidized bed(CFB) combustor and it's burning characteristics were investigated and collected as design parameters. The combustions were controllable and the HCl emission which is most important toxic emission were below 150ppm out of combustor. The differences between conventional coal burning circulating fluidized bed boiler and the exclusive RDF boiler were studied and commercial scale co-generation RDF CFB's were designed.

  • PDF

Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production (폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산)

  • Shun, Do-Won;Bae, Dal-Hee;Cho, Sung-Ho;Lee, Seung-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF

Development of 3MWth Circulating Fluidized Bed Biomass Gasifier (3MWth급 순환유동층 바이오매스 가스화공정 개발)

  • Lee, Jeungwoo;Song, Jaehun;Lee, Dongyoon;Choi, Youngtai;Yang, Won;Lee, Uendo
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.231-233
    • /
    • 2012
  • Circulating Fluidized Bed (CFB) is a technically and economically proven technology for boiler systems and large CFB coal boilers are making inroads into the domestic power boiler market. For biomass gasification, it is also considered as a very promising technology for commercial. Due to the lack of experiences of a large scale CFB gasifier, however, any large scale CFB gasifiers are hard to in Korea in spite of fast-growing demand of domestic market. In this study, a 3 $MW_{th}$ CFB gasifier was developed for biomass gasification. The CFB gasifier consists of interconnected fast and bubbling fluidized bed reactors including unique features for in-situ tar removal. Various numerical and experimental approaches will be presented such as basic modeling works, investigation of hydrodynamics with a cold model, computational particle fluid dynamics and experiments in the 3 MWth gasifier.

  • PDF

Combustion Characteristics of Waste Sewage Sludge using Oxy-fuel Circulating Fluidized Bed (슬러지 순산소 유동층 연소특성)

  • Jang, Ha-Na;Sung, Jin-Ho;Choi, Hang Seok;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.846-853
    • /
    • 2017
  • Cold bed and $30kW_{th}$ pilot bed tests using circulating fluidized bed (CFB) were conducted to apply oxy-fuel technology for waste sludge combustion as a carbon capture and storage technology. In cold bed test, the minimum fluidization velocity ($u_{mf}$) and superficial velocity for fast fluidization was determined as 0.120 m/s and 2.5 m/s, respectively. In the pilot test, air and oxy-fuel combustion experiments for waste sludge were conducted using CFB unit. The flue-gas temperature in 21~25% oxy-fuel combustion was higher than that of air and up to 30% oxy-fuel combustion. In addition, the concentration of carbon dioxide was more than 80% with the oxygen injection range from 21% to 25% in oxy-fuel CFB waste sludge combustion.

A Study on Combustion Characteristics of Refuse Derived Fuel(RDF) in Various Incinerators (연소방식별 폐기물 고형연료(RDF)의 연소특성 연구)

  • Kim Woo-Hyun
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.46-57
    • /
    • 2006
  • For the development of combustion technology of RDF(refuse derived fuel), combustion characteristics are examined in bubbling fluidized bed, circulating fluidized bed, continuos combustor and batch type combustor. The characteristics of combustion and exhaust gas has been compared and analyzed in many type of combustion facilities, which has been utilized as basic data for the advanced research of specified RDF combustion facility. Stable combustion has been observed in bubbling and circulating fluidized bed from controled operating condition like the proper feeding rate and superficial gas velocity. In circulating fluidized bed, concentration of NOx has been increased with the operating condition by the fuel-NO and oxygen reaction and $SO_2$ can be considered not to be produced in RDF fluidized bed from very low concentration in flue gas. HCl concentration is 36.4 ppm as average value and lower than standard emission value, but the counter plan is needed. Shaped RDF and fluff RDF have been compared in continuos combustor and batch type combustor and shaped RDF shows benefit for the stable heat recovery and gas emission shows similar value and characteristics.

Heat Transfer of Smooth and Finned Tubes in A CFBC (순환유동층 보일러 전열관의 열전달 특성)

  • Kim, Bu-Hyeon;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.651-655
    • /
    • 2000
  • The objective of present work is to investigate experimentally the characteristics of heat transfer. A fluidized bed combustion has advantages of pollution control, fuel flexibility and excellent heat transfer. The present study investigates fundamental phenomena of bed-to-surface heat transfer in high temperature fluidized beds to improve design of immersed tube surface. The tested operating variables are bed temperature, supeficial velocity, mean size of bed material, and the rake angle of fin. Generally, heat transfer rates between the fluidized bed and immersed finned-tube are much higher than those of a smooth tube. A life time of finned-tube is generally longer than that of smooth tube.

  • PDF

A Experiment of Combustion Behavior of Biomass Fuels (바이오매스 연료의 연소 특성 실험)

  • KIM, HAKDEOK;KIM, YOUNGDAE;SONG, JUHUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.503-511
    • /
    • 2018
  • There have been many studies of combustion in the circulating fluidized bed. However, little study is available for combustion of wood pellet together fed with wood chip. The mixed ratio of two fuels is an useful information when thermal power company would receive the Renewable Energy Portfolio Standard (RPS) from government. In this study, the combustion behavior and kinetics of such biomass fuels are evaluated using fluidized bed reactor and thermogravimetric analyzers. The mixing ratio of wood chip relative to wood pellet was varied at different temperatures. The results show that a combustion reactivity changed significantly at the wood chip mixing ratio of 40%, particularly at low temperature condition.

Feasibility Study on the Use of CFBC Ash as Non-sintered Binder (순환유동층 보일러애시를 활용한 비소성 결합재로써의 활용 가능성 검토)

  • Kang, Yong Hak;Lim, Gwi Hwan;Kim, Sang Jun;Choi, Young Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.119-126
    • /
    • 2018
  • Recently, the production of circulating fluidized bed combustion ash has been increased in thermal power plants. The addition of limestone for the desulfurizing effect of circulating fluidized bed boiler ash increases the content of CaO and $SO_3$ contained in ash, which is higher than the free fly ash in general fly ash. Unlike conventional fly ash, the circulating fluidized bed combustion ash has a high reactivity when it comes into contact with water due to its hydraulic properties and high free-CaO content. The aim of this study is to investigate the possibility of non-sintered binder by using self-cementing properties of circulating fluidized bed combustion ash. The mechanical and hydration characteristics were investigated according to the content of CFBC ash. In addition, the effects of gymsum type and content on the compressive strength and micro-structure of non-sintered binder pastes.

A Study of Desulfation Characteristics of Circulating Fluidized Bed Combustion for Domestic Anthracite (국내 무연탄의 순환류동층 보일러에서 탈황 특성 연구)

  • 정진도;김장우;하준호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.429-436
    • /
    • 2004
  • Circulating fluidized bed combustion (hereafter CFBC) technology enables an efficient combustion for the materials with low heating values such as high ash coal and sludges. It also has desulfation function by adding limestone directly to combustor. The CFBC has been considered as one of the best processes for low grade coal containing with large contents of ash and sulfur. In this paper, in order to various tests were performed to find the optimum desulfation condition for CFBC using Korean Anthracite. We surveyed possible parameters and conducted desulfation efficiency test in D Thermal Power Plant. In addition, the result of some fundamental theoretical consideration was discussed with CFBC. Optimum limestone size could be considered to be 0.1-0.3mm irrespective of combustion temperature and Ca/S molar ratio variation. Desulfation efficiency increased as the molar ratio increased. Because desulfation process occurs at the surface at higher temperature, inner side of limestone can't be utilized. When surface area is not appropriate, some SO$_2$ emit without reaction. Optimum molar ratio should be decided after considering chemical and physical properties of limestone and coal thoroughly such as particle size, pore size and HGI. Commercial CFBC is operated at Ca/S 1.6. Combustor temperature 840-87$0^{\circ}C$ shows good desulfation efficiency.

A Numerical Study of the Characteristics of Heat Transfer in External Heat Exchanger of CFB Boiler (순환유동층보일러 외부열교환기의 열전달 특성에 관한 수치해석적 연구)

  • Hwang, Moonkyeong;Kim, Jungrae
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.15-16
    • /
    • 2014
  • With the increasing trend in CFB(Circulating Fluidized Bed) boiler scale, the EHE(External Heat Exchanger) must be adopted to the large-scale boilers to recover insufficient heat transfer surface. In this study, the numerical analysis model for EHE in commercial 300MWe CFB boiler was developed with the inclusion of mechanistic model, which enables the heat transfer prediction. Finally, the calculated absorbed heat and derived heat transfer coefficient are evaluated through the verification with experimental data.

  • PDF