• Title/Summary/Keyword: Circulating flow rate

Search Result 102, Processing Time 0.025 seconds

Culture of the Olive Flounder, Paralichthys olivaceus in a Marine Recirculating System (해수 순환 여과 사육 시스템에서 넙치 사육 시험)

  • Bang, Jong-Deuk;Choi, Yong-Suk;Seo, Hyung-Chul
    • Journal of fish pathology
    • /
    • v.18 no.1
    • /
    • pp.91-97
    • /
    • 2005
  • Bio-secure culture of olive flounder Paralichthys olivaceus in the IBK (Intensive Bioproduction Korean) recirculating system with dry pellet was tested for 6 months. The IBK system consists of 12 rearing tanks, 6 sedimentation tanks. 4-sectioned submerged biofilter chamber and channels. The size of each rearing tank was 3m in diameter and 1m in depth. The size of each biofilter chamber was $3.1\times3.3\times2.0$ m (D) and was filled with corrugated plastic plates as a biofilter medium. Total surface area of the biofilter was 3,789.7 $m^2$ Water was circulated by one of two vertical axial pump and circulating rate was about 34 times per day. A UV light sterilizer was used to treat inlet sea water with the flow rate of 4 ton/hr. All fish were treated with 150 ppm formalin 3 times with 5 day interval before stocking. It took 60 days for 'conditioning' the biofilter with the stocking density of 4.5 kg of fish $m^2$. The concentrations of ammonium-nitrogen, nitrite-nitrogen and nitrate-nitrogen in the system remained at the range of 0.096-0.315 mg/L, 0.015-0.504 mg/L, and 2.530-39.517 mg/L, respectively. Water temperature fluctuated from 17.5 to 25.1$^{\circ}C$ and salinity was from 30.1 to 33.5 ppt during rearing period. The fish grew from the average weight of 615.2 g to 1,201.1 g for 180 days. Initial and final fish densities were 8.4 and 15.9$kg/m^2$, Survival rate was 97.1 %. Neither parasites nor noticeable diseases was observed during the raring period even Vibrio spp. were detected from some fish in the system.

Hydrodynamic Properties of Interconnected Fluidized Bed Chemical-Looping Combustors (상호 연결된 유동층 매체 순환식 연소로의 수력학적 특성)

  • Son, Sung Real;Go, Kang Seok;Kim, Sang Done
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.185-192
    • /
    • 2010
  • The chemical-looping combustion(CLC) has advantages of no energy loss for separation of $CO_2$ without $NO_x$ formation. This CLC system consists of oxidation and reduction reactors where metal oxides particles are circulating through these two reactors. In the present study, the reaction kinetic equations of iron oxide oxygen carriers supported on bentonite have been determined by the shrinking core model. Based on the reactivity data, design values of solid circulation rate and solids inventory were determined for the rector. Two types of interconnected fluidized bed systems were designed for CLC application, one system consists of a riser and a bubbling fluidized bed, and the other one has a riser and two bubbling fluidized beds. Solid circulation rates were varied to about $30kg/m^2s$ by aeration into a loop-seal. Solid circulation rate increases with increasing aeration velocity and it increases further with an auxiliary gas flow into the loop-seal. As solid circulation rate is increased, solid hold up in the riser increases. A typical gas leakage from the riser to the fluidized bed is found to be less than 1%.

Computational Fluid Dynamics Model for Solar Thermal Storage Tanks with Helical Jacket Heater and Upper Spiral Coil Heater (상부 코일히터를 갖춘 나선재킷형 태양열 축열조의 성능예측을 위한 CFD 해석모델 개발 및 검증)

  • Baek, Seung Man;Zhong, Yiming;Nam, Jin Hyun;Chung, Jae Dong;Hong, Hiki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In a solar domestic hot water (SDHW) system, solar energy is collected using collector panels, transferred to a circulating heat transfer fluid (brine), and eventually stored in a thermal storage tank (TST) as hot water. In this study, a computational fluid dynamics (CFD) model was developed to predict the solar thermal energy storage in a hybrid-type TST equipped with a helical jacket heater (mantle heat exchanger) and an immersed spiral coil heater. The helical jacket heater, which is the brine flow path attached to the side wall of a TST, has advantages including simple system design, low brine flow rate, and enhanced thermal stratification. In addition, the spiral coil heater further enhances the thermal performance and thermal stratification of the TST. The developed model was validated by the good agreement between the CFD results and the experimental results performed with the hybrid-type TST in SDHW settings.

Catalytic Ozonation of Phenol (페놀의 촉매오존산화 반응에 관한 연구)

  • Lee, Cheal-Gyu;Woo, Jeong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.731-738
    • /
    • 2011
  • In this study AOPs of $O_3/UV$ radiation, $O_3/Mg(OH)_2/UV$ radiation and $O_3/MgO/UV$ radiation system for phenol treatment in aqueous solution was performed in a laboratory scale circulating batch reacter. Flow rate of ozone 1.0 L/min, ozone concentrations $150{\pm}10mg/L$ was maintained constantly at the above-mentioned oxidation processes. During the oxidation processes the $COD_{Cr}$ and TOC was measured in the composition. The pseudo first-order rate constants of the processes was $5.12{\times}10^{-5}$, $1.19{\times}10^{-4}$ and $1.79{\times}10^{-4}sec^{-1}$, and the activation energy was 3.03, 1.79 and $2.32kcal{\cdot}mol^{-1}$ at $20^{\circ}C$, respectively. It was found that both $Mg(OH)_2$ and MgO had remarkable accelerations on degradation of phenol and removal of COD in water. On this basis, $O_3/MgO/UV$ system is an effective and feasible routes for catalytic ozonation of phenol in water.

Effect of Light-Induced ROS Generation Unit on Inactivation of Foodborne Pathogenic Bacteria in Water (광유도 ROS 발생장치의 세척용수 중 식중독 세균에 대한 불활성화 효과)

  • Choi, Jaehyuk;Kim, Dawoon;Jung, Kyu-Seok;Roh, Eunjung;Ryu, Kyoung-Yul;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.583-590
    • /
    • 2019
  • As the consumption of fresh fruits and vegetables increases, food poisoning caused by foodborne pathogen contamination is not decreasing. To prevent the contamination of produce, a quick and easy, low-cost, environmentally-safe disinfection method that does not affect produce freshness or quality is needed. This study demonstrates a new-concept, circulating-water disinfection system that purifies water by using newly developed 'LED-PS (photosensitizer)-induced ROS generation unit'. Using various types of LED-PS induced ROS generation units, we investigated the conditions for reducing the density of various pathogenic bacteria by more than 3 log CFU / mL in 1 hour. The major operational factors affecting the density reduction of the LED-PS-induced ROS generation unit were analyzed. Depending on bacteria species, the density reduction rate was varied. The effect of the units on reducing the density of Bacillus cereus and Pectobacterium carotovorum subsp. carotovorum was high, but the effect on foodborne bacteria such as Escherichia coli was relatively low. In this circulating water disinfection system, the density reduction effect tended to increase as the flow rate increased and the initial bacterial density decreased. As the amount of PS absorbed beads increased, the density reduction effect increased exponentially in some bacteria. Model 3280, a double cylindrical unit connecting two single cylindrical units, could completely sterilize more than 3 log CFU/mL of B. cereus and P. carotovorum subsp. carotovorum in 30 minutes of LED irradiation.

Effect of Pipes Layout and Flow Velocity on Temperature Distribution in Greenhouses with Hot Water Heating System (방열관의 배치와 관내 유속이 온수난방 온실의 온도분포에 미치는 영향)

  • Shin, Hyun-Ho;Kim, Young-Shik;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.335-341
    • /
    • 2019
  • In order to provide basic data for uniformization of temperature distribution in heating greenhouses, heating experiments were performed in two greenhouses with a hot water heating system. By analyzing heat transfer characteristics and improving pipes layout, measures to reduce the variation of pipe surface temperature and to improve the uniformity were derived. As a result of analyzing the temperature distributions of two different greenhouses and examining the maximum deviation and uniformity, it was found that the temperature deviation of greenhouses with a large amount of hot water flow and a short heating pipe was small and the uniformity was high. And it was confirmed that the temperature deviation was reduced and the uniformity was improved when the circulating fan was operated. The correlation between the surface temperature of the heating pipe and the indoor air temperature was a positive correlation and statistically significant(p<0.01) in both greenhouses. It was confirmed that the indoor temperature distribution in a hot water heating greenhouse was influenced by the surface temperature distribution of heating pipe, and the uniformity of indoor temperature distribution could be improved by arranging the heating pipe to minimize the temperature deviation. Analysis of the heat transfer characteristics of heating pipe showed that the temperature deviation increased as the pipe length became longer and the temperature deviation became smaller as the flow rate in pipe increased. Therefore, it was considered that the temperature distribution and the uniformity of environment in a greenhouse could be improved by arranging the heating pipe to shorten the length and controlling the flow velocity in pipe. In order to control the temperature deviation of one branch pipe within $3^{\circ}C$ in the tube rail type hot water heating system most used in domestic greenhouses, when the flow velocity in the pipe is 0.2, 0.4, 0.6, 0.8, $1.0m{\cdot}s^{-1}$, the length of a heating pipe should be limited to 40, 80, 120, 160, 200m, respectively.

Growth of Potato Plug Seedlings as Affected by Photosynthetic Photon Flux in a Closed Transplants Production System (폐쇄형 묘생산 시스템에서 감자 플러그묘의 생장에 미치는 광합성유효광양자속의 영향)

  • Kim, Y.H.;Kim, H.J.;Lee, J.W.;Kim, J.M.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.2
    • /
    • pp.106-114
    • /
    • 2008
  • This study was performed to analyze the distribution of air current speed, $CO_2$ concentration, and photosynthetic photon flux (PPF) in a closed transplants production system (CTPS) for producing quality transplants. And the effect of PPF on the growth of potato (Solanum tuberosum L. cv. Dejima) plug seedlings was analyzed. Uniformity of the air current speed in CTPS was improved by installing perforated floors in duct for air circulating and by adjusting of air flow rate of the fan connected to air conditioning unit used in this study, Measured $CO_2$ concentrations were measured $409{\pm}13$, $950{\pm}25$, and $1,550{\pm}35\;{\mu}mol{\cdot}mol^{-1}$ for setting values of 400, 950, and $1,550\;{\mu}mol{\cdot}mol^{-1}$, respectively. Uniformity of PPF by adding each one the single fluorescent lamp of 20 W at both ends of the single fluorescent lamps of 40 W was highly improved. While the average PPF measured under the twin fluorescent lamps of 55 W installed at regular intervals of 10 cm was decreased by increasing the vertical distance from the lighting sources, the ratio of average PPF measured at both ends to PPF measured in the center was 74-79%. Five levels ($100{\pm}9$, $150{\pm}14$, $200{\pm}17$, $250{\pm}24$ and $300{\pm}31{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) of PPF were provided to investigate the effect of PPF on plant height, fresh weight and dry weight of potato plug seedlings produced in CTPS. Plant height was decreased by increasing PPF. Maximum fresh weight and dry weight were shown under PPF of $250{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Thus PPF of $250\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was enough to produce quality potato transplants under air temperature, photoperiod, and relative humidity of $20^{\circ}C$, 16/8 h, and 70%, respectively. It was concluded that quality indices such as plant height, fresh weight and dry weight could be improved by illuminating of adequate PPF from artificial lighting sources.

Measurement of $\textrm{CO}_2$ Concentration and Leaf Area Index for Crop Photosynthesis Model in Sweet Pepper (단고추의 작물 광합성 모델을 위한 $\textrm{CO}_2$ 농도와 엽면적지 수 측정)

  • Lee, Beom-Seon;Chung, Soon-Ju;Jang, Hong-Gi
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.192-201
    • /
    • 1999
  • This study was aimed to introduce the measurement of $CO_2$ concentration and leaf area index in the phytotron for predicting the effect of CO.E, light and leaf area index on the instantaneous photosynthetic rate of sweet pepper with the existing ASKAM model. Measurements were made in 2 semi-closed phytotron compartments in which three different $CO_2$ concentrations were applied at random. Plants were grown on containers with circulating nutrient solution at 21$^{\circ}C$ and 80-95% relative humidity. The model estimates crop net $CO_2$ uptake for short time intervals during the day based on short-term data of daily radiation, temperature and $CO_2$ concentration. During the photosynthesis measurements, $CO_2$ concentrations in both compartments and in the basement were measured every minute. This was also done for the flow of pure $CO_2$ into the compartment, global radiation, photosynthetic active radiation inside the compartment, temperature and relative humidity. Crop growth models summarize our knowledge on crop behavior and have as such a wide range of applications in analysis, crop management and thus as a farm management tool.

  • PDF

A Study on the Effects of Design Parameters of Vertical Ground Heat Exchanger on the Borehole Thermal Resistance (수직밀패형 지중열교환기의 설계인자가 보어홀 전열저항에 미치는 영향에 관한 연구)

  • Chang, Keun Sun;Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.128-135
    • /
    • 2018
  • Currently, vertical closed ground heat exchangers are the most widely utilized geothermal heat pump systems and the major influencing parameters on the performance of ground heat exchangers are the ground thermal conductivity(k) and borehole thermal resistance($R_b$). In this study, the borehole thermal resistance was calculated from the in-situ thermal response test data and the individual effects of design parameters (flow rate, number of pipe, grout composition) on the borehole thermal resistance were analyzed. The grout thermal resistance was also compared with the correlations in the literatures. The borehole thermal resistance of the investigated ground heat exchanger results in 0.1303 W/m.K and the grout thermal resistance (66.6% of borehole thermal resistance) is the most influencing parameter on borehole heat transfer compared to the other design parameters (pipe thermal resistance, 31.5% and convective thermal resistance, 1.9%). In addition, increasing the thermal conductivity of grout by adding silica sand to Bentonite is more effective than the other design improvements, such as an increase in circulating flowrate or number of tubes on enhancing borehole heat transfer.

The Treatment of Domestic Wastewater by Coagulation-Crossflow Microfiltration (응집-정밀여과에 의한 도시하수의 처리)

  • Sim, Joo-Hyun;Kim, Dae-Hwan;Seo, Hyung-Joon;Chung, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.581-589
    • /
    • 2005
  • Recently, membrane processes have been replacing the conventional processes for waste water treatment to produce better quality of effluent and to meet more stringent regulations because of water shortage. However, using membrane processes for water treatment has confronted with fouling and difficulty in treating dissolved organic pollutants. In this study, membrane process equipped with crossflow microfiltration is combined with coagulation process using alum and PAC to improve permeability and treatment efficiency. The effects of coagulant dosage and optimum membrane operating conditions were investigated from measurement of permeate flow, cumulative volume, total resistance, particle size, dissolved organic pollutant, dissolved aluminium and quality of effluent. Characteristic of PAC coagulation was compared with that of alum coagulation. PAC coagulation reduced membrane fouling because of forming larger particle size and increased permeate velocity and cumulative volume. Less dissolved organic pollutants and dissolved aluminum made decreasing-rate of permeate velocity being lowered. At using $0.2\;{\mu}m$ membrane, cake filtration observed. At using $0.45\;{\mu}m$ membrane, there was floc breakage due to shear stress occurred born circulating operation. It made floc size smaller than membrane pore size, which subsequently to decrease permeate velocity and to increase total resistance. The optimum coagulation dosage was $300{\pm}50\;mg/L$ for both alum and PAC. PAC coagulation was more efficiently used with $0.2\;{\mu}m$ membrane, and the highest permeate flux was in using $0.45\;{\mu}m$membrane. The greatest efficiency of treatment was as follows; turbidity 99.8%, SS 99.9%, $BOD_5$ 94.4%, $COD_{Cr}$ 95.4%, T-N 54.3%, T-P 99.8%.