• Title/Summary/Keyword: Circulating Power

Search Result 354, Processing Time 0.027 seconds

Development of 50kW High Efficiency Fast Charger with Wide Charging Voltage Range (넓은 충전전압 범위를 갖는 50kW급 고효율 급속충전기 개발)

  • Park, Jun-Sung;Kim, Min-Jae;Jeong, Heon-Soo;Kim, Joo-Ha;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.267-274
    • /
    • 2016
  • In this study, a fast charger for electric vehicle with wide charging voltage range is proposed. To achieve high efficiency, three-level topologies are employed for the AC-DC and DC-DC converters. Given that the output range of the DC-DC converter in fast chargers is quite wide, the circulating current of conventional three-level converter will increase under low voltage condition. The proposed hybrid switching method mitigates this issue. When a coupled inductor is used on the output side, the circulating current is further reduced, and the switches $S_2$, $S_3$, $S_6$, and $S_7$ achieve turning-off under the ZCS condition. Experimental results from a 50 kW prototype are provided to validate the proposed charger, and a rated efficiency of 95.9% is obtained.

Voltage-Fed Push-Pull PWM Converter Featuring Wide ZVS Range and Low Circulating Loss with Simple Auxiliary Circuit

  • Ye, Manyuan;Song, Pinggang;Li, Song;Xiao, Yunhuang
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.965-974
    • /
    • 2018
  • A new zero-voltage-switching (ZVS) push-pull pulse-width modulation (PWM) converter is proposed in this paper. The wide ZVS condition for all of the switches is obtained by utilizing the energy stored in the output inductor and magnetizing inductance. As a result, the switching losses can be dramatically reduced. A simple auxiliary circuit including two small diodes and one capacitor is added at the secondary side of a high frequency (HF) transformer to reset the primary current during the circulating stage and to clamp the voltage spike across the rectifier diodes, which enables the use of low-voltage and low-cost diodes to reduce the conducting and reverse recovery losses. In addition, there are no active devices or resistors in the auxiliary circuit, which can be realized easily. A detailed steady operation analysis, characteristics, design considerations, experimental results and a loss breakdown are presented for the proposed converter. A 500 W prototype has been constructed to verify the effectiveness of the proposed concept.

THE PERFORMANCE ANALYSIS OF A CIRCULATING WATER PUMP FOR A NUCLEAR POWER PLANT (원자력 발전소용 순환수 펌프의 성능해석)

  • Lee, M.S.;Han, B.Y.;Hwang, D.Y.;Yoo, S.S.;Park, H.K.
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.69-75
    • /
    • 2009
  • The objective of this study is to investigate the suitable design for a domestic Circulating water pump(CWP), which is used in cooling-water intakes for the unit 3 and 4 of Yeonggwang nuclear power plant. All the simulations are performed, using CFD method with a commercial code STAR-CCM+ version 3.02. After modeling a present design of the pump, the flow around the rotating blade was calculated by using quasi-static method and sliding mesh method with the almost same condition as an actual state. Based on fundamental simulations with various depth of sea water, the reference pressure for the boundary condition of the present study was decided. To verify the reliability of the calculation results, the suction flow rate of the data was compared with that of the experimental data. As a result of this comparison, it is confirmed that two results are fairly consistent. For the improvement of the suction flow rate, computational analysis was done by changing a flow channel and blade shapes. It is shown that the suction flow rate of the new pump was improved.

A Three Level ZVZCS Phase-Shifted DC/DC Converter Using A Tapped Inductor And A Snubber Capacitor (탭-인덕터와 스너버-커패시터를 적용한 3 Level 영전압.영전류 스위칭 DC/DC 컨버터)

  • 김은수;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.209-216
    • /
    • 2001
  • The conventional three-level high frequency phase-shifted dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current and RMS current stress, conduction losses of transformer and switching devices increases. To alleviate these problems, we propose an improved three-level Zero Voltage and Zero Current Switchig (ZVZCS) dc/dc converter using a tapped inductor, a snubber capacitor and two snubber diodes attached at the secondary side of transformer. The proposed ZVZCS converter is verified on a 7kW, 30kHz experimental prototype.

  • PDF

An auxiliary circuit for reducing loss during free-wheeling interval in FB ZVT PWM converter (FB ZVT PWM 컨버터의 환류구간 손실저감을 위한 보조회로)

  • 윤창선;김병철;김광헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.209-214
    • /
    • 2000
  • In this paper, we propose a FB ZVT(full bridge zero voltage transition) PWM OC~OC converter which uses a a saturable reactor, instead of two additional switches, to achieve zero voltage switching. The conventional h high frequency phase shifted FB ZVT PWM OC-OC converter has a disadvantage that a circulating current f flows through high frequency transformer and switching devices during the free-wheeling interval. Due to this c circulating current, conduction loss increases. In order to reduce such the loss as this, we propose circuit of r reducing conduction loss at the secondary side of transformer. The operation principles are explained in detail a and the several interesting simulations and experimental results verify the validity of the proposed circuit.

  • PDF

On DC-Side Impedance Frequency Characteristics Analysis and DC Voltage Ripple Prediction under Unbalanced Conditions for MMC-HVDC System Based on Maximum Modulation Index

  • Liu, Yiqi;Chen, Qichao;Li, Ningning;Xie, Bing;Wang, Jianze;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.319-328
    • /
    • 2016
  • In this study, we first briefly introduce the effect of circulating current control on the modulation signal of a modular multilevel converter (MMC). The maximum modulation index is also theoretically derived. According to the optimal modulation index analysis and the model in the continuous domain, different DC-side output impedance equivalent models of MMC with/without compensating component are derived. The DC-side impedance of MMC inverter station can be regarded as a series xR + yL + zC branch in both cases. The compensating component of the maximum modulation index is also related to the DC equivalent impedance with circulating current control. The frequency characteristic of impedance for MMC, which is observed from its DC side, is analyzed. Finally, this study investigates the prediction of the DC voltage ripple transfer between two-terminal MMC high-voltage direct current systems under unbalanced conditions. The rationality and accuracy of the impedance model are verified through MATLAB/Simulink simulations and experimental results.

A Study on Power-Flow Analysis of The Lepelletier 6-Speed Automatic Transmission (6 속 자동변속기용 레펠레티아 유성 치차의 동력 해석에 관한 연구)

  • 박진홍;심재경;강봉수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.652-655
    • /
    • 2004
  • In gear-train design, power-flow analysis is a very important process. The method for power-flow analysis apply the power balance equation and torque balance equation to each fundamental circuit. Then, the equation are solved simultaneously to determine the power-flow in planetary gear train. In this paper we perform power-flow analysis of a 6-speed automatic transmission. With this results are used to represent block diagram. In addition, the efficiencies of epicyclic inversion of the 6-speed automatic transmission is obtained.

  • PDF

Studies on the clinker formed in thermal power plants (화력발전소에서 생성된 크링커에 대한 연구)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Yun, Yeo-Chan;Lee, Tae-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.2
    • /
    • pp.34-40
    • /
    • 2003
  • Analyses for concentration, surface phenomena, and crystal structure were performed to identify the causes of clinker formation in three type of pulverized coal fired boilers. Some clinkers had partially molten surface and more CaO and $Fe_2O_3$ as compared with fly ash, and the major crystalline phases identified in the clinker were mullite and quartz. Clinkers were formed in high temperature zone of the boiler according to the identification of mullite by XRD. Free $SiO_2$ in sand combined with K, Na and Ca in limestone served as a fluxing agent to form clinkers in a circulating bed boiler.

  • PDF

A Study on the Correlation between Sheath Circulating Current and Installation Type of Domestic Underground Transmission Power Cables (국내 지중송전선로 포설형태와 시스순환전류와의 상관관계 검토)

  • Kim, Nam-Yoel;Jung, Chae-Kyun;Lee, Jong-Beom;Yoon, Yang-Woung;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.484-486
    • /
    • 2002
  • In this paper, installation type is analyzed into a single and mixed burying type on burying situation of domestic underground transmission cables, and problem of underground cable is discussed with investigating the relation between burying type and sheath circulation current. Investigated cable systems are 520 T/L which have 512T/L for 154kV and 8T/L for 345kV. The authors consider that the analysis of sheath circulating current with burying type will contribute for setting reduction methods of sheath circulation current.

  • PDF

Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production (폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산)

  • Shun, Do-Won;Bae, Dal-Hee;Cho, Sung-Ho;Lee, Seung-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF