• Title/Summary/Keyword: Circuit pressure

Search Result 536, Processing Time 0.026 seconds

Study on Integrated for Capacitive Pressure Sensor (용량성 압력센서의 집적화에 관한 연구)

  • 이윤희
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.48-58
    • /
    • 1998
  • For the purpose of designing novel capacitance pressure sensor, several effects on sensitivity such as parasitic capacitance effects, temperature/thermal drift and leakage current have to be eleiminated. This paper proposed the experimental studies on frequency compensation method by electronic circuit technique, C-V converting method with switched capacitor and C-F converting method with schmitt trigger circuit. The third interface circuit by frequency compensation method is composed to eliminate the drift and leakage component by comparision sensing frequency with reference frequency. The signal transmission is realized by digital signal to minimize the influence of noise and high resolution is obtained by means of increasing the number of digital bits. In the fabricated high performance C-V interface, the offset voltage was not appeared, and in case of voltage source, 4.0V, feed back capacitance, 10㎊, the pressure, 0~10 ㎪, the sensitivity of C-V converter is 28 ㎷/㎪.V, the temperature drift characteristic, 0.051 %F.S./$^{\circ}C$ and C-F converter shows -6.6 Hz/pa, 0.078 %F.S./$^{\circ}C$ respectively, relatively good ones.

  • PDF

Influence of SF6/N2 Gas Mixture Ratios on the Lightning Streamer Propagation Characteristics of 22 kV MV Circuit Breaker

  • Gandhi, R.;Chandrasekar, S.;Nagarajan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1663-1672
    • /
    • 2018
  • In recent times, gas insulated medium voltage (MV) circuit breakers (CB) form a vital component in power system network, considering its advantages such as reduced size and safety margins. Gas insulation characteristics of circuit breakers are generally measured by lightning impulse (LI) test according to IEC standard 60060-1 as a factory routine test. Considering the environmental issues of $SF_6$ gas, many research works are being carried out towards the mixture of $SF_6$ gases for high voltage insulation applications. However, few reports are only available regarding the LI withstand and streamer propagation characteristics (at both positive and negative polarity of waveform) of $SF_6/N_2$ gas mixture insulated medium voltage circuit breakers. In this paper, positive and negative polarity LI tests are carried out on 22 kV medium voltage circuit breaker filled with $SF_6/N_2$ gas mixture at different gas pressures (1-5 bar) and at different gas mixture ratios. Important LI parameters such as breakdown voltage, streamer velocity, time to breakdown and acceleration voltage are evaluated with IEC standard LI ($1.2/50{\mu}s$) waveform. Weibull distribution analysis of LI breakdown voltage data is carried out and 50% probability breakdown voltage, scale parameter and shape parameter are evaluated. Results illustrate that the $25%SF_6+75%N_2$ gas filled insulation considerably enhances the LI withstand and breakdown strength of MV circuit breakers. LI breakdown voltage of circuit breaker under negative polarity shows higher value when compared with positive polarity. Results show that maintaining the gas pressure at 0.3 MPa (3 bar) with 10% $SF_6$ gas mixed with 90% $N_2$ will give optimum lighting impulse withstand performance of 22 kV MV circuit breaker.

Investigation of Small Current Interruption Performance for New Type of Interrupting Chamber in SF$_{6}$ Gas Circuit Breaker (신차단방식 SF$_{6}$ 가스 차단기의 소전류 차단성능 연구)

  • Song, Won-Pyo;Kweon, Ki-Yeoung;Lee, Jae-Sung;Song, Ki-Dong;Kim, Maeng-Hyun;Ko, Hee-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.519-526
    • /
    • 2005
  • This paper presents computer simulation results for developing new type of SF$_{6}$ Circuit Breaker in terms of cold gas flow after small current interruption. This cold gas flows down a nozzle into the chamber of a circuit breaker. There are many difficult problems in analyzing the gas flow due to complex geometry, moving boundary, shock wave and so on. When predicting the dielectric capability of a gas circuit breaker after interruption, the gas pressure and density distributions due to the cold gas must be considered in addition to the electrical field imposed across the gas. A self-coded computational fluid dynamics (CFD) program is used for the simulation of cold gas flow in order to evaluate the electrical field characteristic across open contacts and transient characteristics of insulations after small current interruption.

Fabrication of embedded circuit patterns for Ie substrates using UV laser (UV 레이저 응용 반도체 기판용 임베디드 회로 패턴 가공)

  • Sohn, Hyon-Kee;Shin, Dong-Sig;Choi, Ji-Yeon
    • Laser Solutions
    • /
    • v.14 no.1
    • /
    • pp.14-18
    • /
    • 2011
  • Semiconductor industry demands decrease in line/space dimensions of IC substrates. Particularly for IC substrates for CPU, line/space dimensions below $10{\mu}m/10{\mu}m$ are expected to be used in production since 2014. Conventional production technologies (SAP, etc.) based on photolithography are widely agreed to be reaching capability limits. To address this limitation, the embedded circuit fabrication technology using laser ablation has been recently developed. In this paper, we used a nanosecond UV laser and a picosecond UV laser to fabricate embedded circuit patterns into a buildup film with $SiO_2$ powders for IC substrate. We conducted SEM and EDS analysis to investigate surface quality of the embedded circuit patterns. Experimental results showed that due to higher recoil pressure, picosecond UV laser ablation of the buildup film generated a better surface roughness.

  • PDF

Characteristics of direct laser micromachining of IC substrates using a nanosecond UV laser (나노초 UV 레이저 응용 IC 기판 소재 조성별 가공 특성)

  • Sohn, Hyon-Kee;Shin, Dong-Sig;Choi, Ji-Yeon
    • Laser Solutions
    • /
    • v.15 no.3
    • /
    • pp.7-10
    • /
    • 2012
  • Dimensions (line/space) of circuits in IC substrates for high-end chips (e.g. CPU, etc.) are anticipated to decrease as small as $10{\mu}m/10{\mu}m$ in 2014. Since current etch-based circuit-patterning processes are not able to address the urgent requirement from industry, laser-based circuit patterning processes are under active research in which UV laser is used to engrave embedded circuits patterns into IC substrates. In this paper, we used a nanosecond UV laser to directly fabricate embedded circuit patterns into IC substrates with/without ceramic powders. In experiments, we engraved embedded circuit patterns with dimensions (width/depth) of abut $10{\mu}m/10{\mu}m$ and $6{\mu}m/6{\mu}m$ into the IC substrates. Due to the recoil pressure occurring during ablation, the circuit patterning of the IC substrates with ceramic powders showed the higher ablation rate.

  • PDF

Comparison Analysis of Dynamic Characteristics of Servo-hydraulic Piezo-driven Injector between 3-way and Bypass-circuit Type (3-way형과 Bypass형 서보유압 피에조 인젝터의 구동특성 비교)

  • Jo, Insu;Jeong, Myoungchul;Lee, Jinwook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.169-175
    • /
    • 2013
  • CRDi technology of diesel engine was developed from in the early 2000s due to a need to increase fuel efficiency and environment care. Especially, high-pressure fuel injection system in CRDi system which has a fuel injection unit including an injector, a fuel pump and common-rail, etc. becomes possible to make the exhaust gas clean as well as power improvement. In this study, comparison of dynamic characteristics of servo-hydraulic piezo-driven injector with 3-way and bypass-circuit type was analyzed by using the AMESim code. As results of this study, it found the bypass-circuit inside servo-hydraulic piezo injector can cause a faster injection response than that of the 3-way type. Also it was shown that bypass-circuit type had better control capability due to hydraulic bypass system.

Analysis of electric circuit using capacitor for driving linear compressor (콘덴서를 이용한 선형압축기 구동 전기회로 해석)

  • Ko, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je;Hong, Yong-Ju;Yeom, Han-Kil;Koh, Deuk-Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.43-47
    • /
    • 2012
  • A linear compressor generates pulsating pressure and oscillating flow in a cryocooler such as Stirling cryocooler and pulse tube refrigerator. It is driven by AC power source and designed to operate at resonance of piston motion. The driving voltage level is determined by electric parameters of resistance, inductance and thrust constant of linear motor. From voltage equation on linear motor, the power factor of driving power is inherently less than 1. The phase difference between voltage and current of supplied power can be zero using capacitor and this can minimize a supply voltage level. Especially, the linear compressor of kW class requires high voltage and thus can cause a difficulty in selecting power supply unit due to limitation of voltage level. The capacitor in driving electric circuit is useful to settle this problem. In this study, the electric circuit of linear compressor is analytically investigated with assumption of mechanical resonance. The electric parameters of commercial linear motor are used in the analysis. The effects of capacitor on driving voltage level and power factor are investigated. From analytic results, it is shown that the voltage level can be mimized with using capacitor in driving electric circuit.

Pressure Control of Brake Circuit with Piezoelectric-hydraulic Pump Using Pressurization/Depressurization Characteristics (압전유압펌프가 적용된 브레이크 회로의 가감압 특성을 이용한 압력 제어)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung;Kwon, Jun-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.8-15
    • /
    • 2017
  • In this paper, an equivalent brake hydraulic circuit with a piezoelectric hydraulic pump was constructed, and load pressure control for better pressurization/depressurization characteristics was conducted. To understand pressurization/depressurization characteristics of the equivalent hydraulic circuit, the relation between the load pressure and the input voltage was revealed experimentally. Experiments were also conducted to observe effect of the solenoid valve on depressurization characteristics. In the pressurization experiment, it was validated that transient response time required to achieve desired load pressure may be reduced through voltage control to change pressurization gradient. By applying the valve on/off time control and voltage control, it was also possible to reduce response time in the depressurization process. Therefore, transient response time may be improved within 10ms for pressurization and within 30 ms for depressurization using the control technique suggested in this study. The load pressure control method proposed in this study is useful for controlling load pressure of a hydraulic brake system with the piezoelectric hydraulic pump.

Pressure Monitoring System in Gastro-Intestinal Tract

  • Kim, Byung-Kyu;Kim, Yong-In;Park, Suk-Ho;Jo, Jin-Ho;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.196-201
    • /
    • 2005
  • Diseases in the gastro-intestinal tract are on an increasing trend. In order to diagnose a patient, various signals of the digestive organ, such as temperature, pH, and pressure, can offer the helpful information. Among the above mentioned signals, we choose the pressure variation as a monitoring signal. The variation of a pressure signal of the gastro-intestinal tract can offer the information of a digestive trouble or some clues of the diseases. In this paper, a pressure monitoring system for the digestive organs of a living pig is presented. This is why a pig's gastro-intestinal tract is very similar as human's. This system concept is to transmit the measured biomedical signals from a transmitter in a living pig to a wireless receiver that is positioned out of body. The integrated solution includes the swallow type pressure capsule and the receiving set consisting of a receiver, decoder circuit. The merit of the proposed system is that the monitoring system can supply the precise and a durable characteristic to measure and to transmit a signal in the gastro-intestinal tract. We achieved the pressure tracings in digestive organs and verified the validity of system after several in-vivo tests using the pressure monitoring system. Through various experiments, we found each organ has its own characterized pressure fluctuation.

  • PDF

Design of Digital Calibration Circuit of Silicon Pressure Sensors (실리콘 압력 센서의 디지털 보정 회로의 설계)

  • Kim, Kyu-Chull
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.245-252
    • /
    • 2003
  • We designed a silicon pressure sensor interface circuit with digital calibration capability. The interface circuit is composed of an analog section and a digital section. The analog section amplifies the weak signal from the sensor and the digital section handles the calibration function and communication function between the chip and outside microcontroller that controls the calibration. The digital section is composed of I2C serial interface, memory, trimming register and controller. The I2C serial interface is optimized to suit the need of on-chip silicon microsensor in terms of number of IO pins and silicon area. The major part of the design is to build a controller circuit that implements the optimized I2C protocol. The designed chip was fabricated through IDEC's MPW. We also made a test board and the test result showed that the chip performs the digital calibration function very well as expected.

  • PDF