• Title/Summary/Keyword: Circuit modeling

Search Result 820, Processing Time 0.024 seconds

A Study on the reduction of surface roughness by analyzing the thickness of photocurable sculpture (광조형물의 패턴두께에 따른 표면 거칠기 저감을 위한 공정연구)

  • Kim, Young-Su;Yang, Hyoung-Chan;Kim, Go-Beom;Dang, Hyun-Woo;Doh, Yang-Hoi;Choi, Kyung-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.75-82
    • /
    • 2016
  • In this paper, we developed a 3D printing system using a photo-curing resin in order to reduce the surface roughness of a sculpture produced with the 3D printer. Using the pattern of the resulting variable thickness, that gave rise to a stepped shape, and the area error of the photo-curable sculpture, a study was carried out for the process to reduce the surface roughness. At a given value of stage velocity (40~70 mm/s) and output air pneumatic pressure (20~60 kPa), the minimum pattern thickness of the pattern was achieved $65{\mu}m$ and the maximum pattern thickness of up to $175{\mu}m$. To increases the pattern resolution to about $40{\mu}m$, the process conditions should be optimized. 3D surface Nano profiler was used to find the surface roughness of the sculpture that was measured to be minimum $4.7{\mu}m$ and maximum $8.7{\mu}m$. The maximum surface roughness was reduced about $1.2{\mu}m$ for the maximum thickness of the pattern. In addition, a FDM was used to fabricate the same sculpture and its surface roughness measurements were also taken for comparison with the one fabricated using photo-curing. Same process conditions were used for both fabrication setups in order to perform the comparison efficiently. The surface roughness of the photo-curable sculpture is $5.5{\mu}m$ lower than the sculpture fabricated using FDM. A certain circuit patterns was formed on the laminated surface of the photo-curable sculpture while there was no stable pattern on the laminated surface of the FDM based sculpture the other hand.

Evaluation Method for Protection Coordination of PV Systems Interconnected with Primary Feeders (태양광전원이 연계된 고압배전선로의 보호협조 평가 방안에 관한 연구)

  • Kim, Byungki;Kim, Sohee;Ryu, Kyungsang;Rho, Daeseok
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.4
    • /
    • pp.29-37
    • /
    • 2011
  • Dispersed generation (DG) such as wind power (WP) and Photovoltaic systems (PV) that has been promoted at the national level recently is mainly being introduced into distribution systems adjacent to consumers because it is generation on a small scale when compared to current generation. Due to its characteristics, DG can be operated by interconnection with distribution systems to present security of more stable power and efficient use of power facilities and resources. Problems on protection coordination of distribution systems by reverse flow of DG can roughly be divided into three possibilities: excess in rated breaking capacity (12.5KA) of protective devices by a fault in DG current supply, failure to operate protective devices by an apparent effect that can occur by reduction in impedance parallel circuit fault current due to interconnection of DG, and malfunction of protective devices by interconnection transformer connection type. The purpose of this study is to analyze problems in protection coordination that can occur when DG is operated by interconnection with distribution systems by conducting modeling and simulations by using theoretical symmetrical components and MATLAB/SIMULINK to present methods to improve such problems.

Regional Balanced Development Policy Leverage in the Capital and Non-Capital Areas : Focusing on Local Function Concentration and Dispersion Structure (수도권과 비수도권의 지역균형발전 정책 레버리지 탐색 : 지역의 기능 집중·분산 구조를 중심으로)

  • Lee, Jin-Hee;Lee, Man-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.502-512
    • /
    • 2019
  • To examine the problem structure of balanced regional development policy and identify the causes of the gap between the capital and non-capital areas, this study examined the causal structure in terms of the concentration and distribution of functions in the metropolitan area and non-capital area and explored the policy leverage. As a research method, the causal map was drawn using System Dynamics techniques and policy leverage was derived through an exploration of the feedback structure. In particular, the causes of the problems in balanced regional development policies were approached by system accidents rather than by single-circuit accidents, and causality analysis was performed among the variables constituting balanced regional development policies based on system accidents. In particular, it singled out 31 variables, developed 13 feedback loops, and confirmed four major policy leverages, including relocation of the capital function, local decentralization policies, consistent development, and investment practices centered on the Non­Capital Area. Subsequently, a follow-up study by computer simulation is needed by modeling the structure of the system to identify the ripple effect of the policies of the Capital Area on the Non­Capital Area.

Design of a radiation-tolerant I-gate n-MOSFET structure and analysis of its characteristic (I 형 게이트 내방사선 n-MOSFET 구조 설계 및 특성분석)

  • Lee, Min-woong;Cho, Seong-ik;Lee, Nam-ho;Jeong, Sang-hun;Kim, Sung-mi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1927-1934
    • /
    • 2016
  • In this paper, we proposed a I-gate n-MOSFET (n-type Metal Oxide Semiconductors Field Effect Transistor) structure in order to mitigate a radiation-induced leakage current path in an isolation oxide interface of a silicon-based standard n-MOSFET. The proposed I-gate n-MOSFET structure was designed by using a layout modification technology in the standard 0.18um CMOS (Complementary Metal Oxide Semiconductor) process, this structure supplements the structural drawbacks of conventional radiation-tolerant electronic device using layout modification technology such as an ELT (Enclosed Layout Transistor) and a DGA (Dummy Gate-Assisted) n-MOSFET. Thus, in comparison with the conventional structures, it can ensure expandability of a circuit design in a semiconductor-chip fabrication. Also for verification of a radiation-tolerant characteristic, we carried out M&S (Modeling and Simulation) using TCAD 3D (Technology Computer Aided Design 3-dimension) tool. As a results, we had confirmed the radiation-tolerant characteristic of the I-gate n-MOSFET structure.

A Study on Motion Estimator Design Using DCT DC Value (DCT 직류 값을 이용한 움직임 추정기 설계에 관한 연구)

  • Lee, Gwon-Cheol;Park, Jong-Jin;Jo, Won-Gyeong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.3
    • /
    • pp.258-268
    • /
    • 2001
  • The compression method is necessarily used to send the high quality moving picture that contains a number of data in image processing. In the field of moving picture compression method, the motion estimation algorithm is used to reduce the temporal redundancy. Block matching algorithm to be usually used is distinguished partial search algorithm with full search algorithm. Full search algorithm be used in this paper is the method to compare the reference block with entire block in the search window. It is very efficient and has simple data flow and control circuit. But the bigger the search window, the larger hardware size, because large computational operation is needed. In this paper, we design the full search block matching motion estimator. Using the DCT DC values, we decide luminance. And we apply 3 bit compare-selector using bit plane to I(Intra coded) picture, not using 8 bit luminance signals. Also it is suggested that use the same selective bit for the P(Predicted coded) and B(Bidirectional coded) picture. We compare based full search method with PSNR(Peak Signal to Noise Ratio) for C language modeling. Its condition is the reference block 8$\times$8, the search window 24$\times$24 and 352$\times$288 gray scale standard video images. The result has small difference that we cannot see. And we design the suggested motion estimator that hardware size is proved to reduce 38.3% for structure I and 30.7% for structure II. The memory is proved to reduce 31.3% for structure I and II.

  • PDF

Design of a Low Noise 6-Axis Inertial Sensor IC for Mobile Devices (모바일용 저잡음 6축 관성센서 IC의 설계)

  • Kim, Chang Hyun;Chung, Jong-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.397-407
    • /
    • 2015
  • In this paper, we designed 1 chip IC for 3-axis gyroscope and 3-axis accelerometer used for various IoT/M2M mobile devices such as smartphone, wearable device and etc. We especially focused on analysis of gyroscope noise and proposed new architecture for removing various noise generated by gyroscope MEMS and IC. Gyroscope, accelerometer and geo-magnetic sensors are usually used to detect user motion or to estimate moving distance, direction and relative position. It is very important element to designing a low noise IC because very small amount of noise may be accumulated and affect the estimated position or direction. We made a mathematical model of a gyroscope sensor, analyzed the frequency characteristics of MEMS and circuit, designed a low noise, compact and low power 1 chip 6-axis inertial sensor IC including 3-axis gyroscope and 3-axis accelerometer. As a result, designed IC has 0.01dps/${\sqrt{Hz}}$ of gyroscope sensor noise density.

Convergence Comparison of Linear Oscillating Electric Machines (리니어 오실레이팅 전기기기의 비교 연구)

  • Jeong, Sung-In;Eom, Sang In
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.273-280
    • /
    • 2021
  • This paper presents the results of study of linear oscillating electric machine; Cartesian, cylindrical type with permanent magnet, flux reversal, cylindrical reluctance, and transverse flux type. The focus of the work is the suggestion of the characteristics and design process of propose topology, respectively. First of all, there are five types of the proposed to this study on the basis of the existing literatures; Cartesian type, cylindrical type, flux reversal type, cylindrical reluctance type, and transverse flux type. All topology is achieved using equivalent magnetic circuit considering leakage elements as initial modeling. Cartesian type is investigated by number of phases and number of pole pairs using optimal process. A cylindrical type is described by number of phases and displacement of stroke. The flux reversal type is proposed based on the symmetrical and non symmetrical stator cores of the surface mounted PMs mover, and non slanted PMs and slanted PMs of the flux concentrating PMs mover. A cylindrical reluctance type is studied by the shape of mover teeth in geometric aspect to reduce force ripple and increase magnetic flux. A transverse flux type is considered by dividing the transverse flux electric excited and the transverse flux permanent magnet excited. It is significant that the study gives a design rules and features of linear oscillating electric machine.

Learning Method for Regression Model by Analysis of Relationship Between Input and Output Data with Periodicity (주기성을 갖는 입출력 데이터의 연관성 분석을 통한 회귀 모델 학습 방법)

  • Kim, Hye-Jin;Park, Ye-Seul;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.7
    • /
    • pp.299-306
    • /
    • 2022
  • In recent, sensors embedded in robots, equipment, and circuits have become common, and research for diagnosing device failures by learning measured sensor data is being actively conducted. This failure diagnosis study is divided into a classification model for predicting failure situations or types and a regression model for numerically predicting failure conditions. In the case of a classification model, it simply checks the presence or absence of a failure or defect (Class), whereas a regression model has a higher learning difficulty because it has to predict one value among countless numbers. So, the reason that regression modeling is more difficult is that there are many irregular situations in which it is difficult to determine one output from a similar input when predicting by matching input and output. Therefore, in this paper, we focus on input and output data with periodicity, analyze the input/output relationship, and secure regularity between input and output data by performing sliding window-based input data patterning. In order to apply the proposed method, in this study, current and temperature data with periodicity were collected from MMC(Modular Multilevel Converter) circuit system and learning was carried out using ANN. As a result of the experiment, it was confirmed that when a window of 2% or more of one cycle was applied, performance of 97% or more of fit could be secured.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

A Study on the Connectivity Modeling Considering the Habitat and Movement Characteristics of Wild Boars (Sus scrofa) (멧돼지(Sus scrofa) 서식지 및 이동 특성을 고려한 연결성 모델링 연구)

  • Lee, Hyun-Jung;Kim, Whee-Moon;Kim, Kyeong-Tae;Jeong, Seung-Gyu;Kim, Yu-Jin;Lee, Kyung Jin;Kim, Ho Gul;Park, Chan;Song, Won-Kyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.4
    • /
    • pp.33-47
    • /
    • 2022
  • Wild boars(Sus scrofa) are expanding their range of behavior as their habitats change. Appearing in urban centers and private houses, it caused various social problems, including damage to crops. In order to prevent damage and effectively manage wild boars, there is a need for ecological research considering the characteristics and movement characteristics of wild boars. The purpose of this study is to analyze home range and identify land cover types in key areas through tracking wild boars, and to predict the movement connectivity of wild boars in consideration of previous studies and their preferred land use characteristics. In this study, from January to June 2021, four wild boars were captured and tracked in Jinju city, Gyeongsangnam-do, and the preferred land cover type of wild boars was identified based on the MCP 100%, KDE 95%, and KDE 50% results. As a result of the analysis of the home range for each individual, it was found that 100% of MCP was about 0.68km2, 2.77km2, 2.42km2, and 0.16km2, and the three individuals overlapped the home range, refraining from habitat movement and staying in the preferred area. The core areas were analyzed as about 0.55km2, 2.05km2, 0.82km2, and 0.14km2 with KDE 95%., and about 0.011km2, 0.033km2, 0.004km2, and 0.003km2 with KDE 50%. When the preferred land cover type of wild boar was confirmed based on the results of analysis of the total home range area and core area that combined all individuals, forests were 55.49% (MCP 100%), 54.00% (KDE 95%), 77.69% (KDE 50%), respectively, with the highest ratio, and the urbanization area, grassland, and agricultural area were relatively high. A connectivity scenario was constructed in which the ratio of the land cover type preferred by the analyzed wild boar was reflected as a weight for the resistance value of the connectivity analysis, and this was compared with the connectivity evaluation results analyzed based on previous studies and wild boar characteristics. When the current density values for the wild boar movement data were compared, the average value of the existing scenario was 2.76, the minimum 1.12, and the maximum 4.36, and the weighted scenario had an average value of 2.84, the minimum 0.96, and the maximum 4.65. It was confirmed that, on average, the probability of movement predictability was about 2.90% better even though the weighted scenario had movement restrictions due to large resistance values. It is expected that the identification of the movement route through the movement connectivity analysis of wild boars can be suggested as an alternative to prevent damage by predicting the point of appearance. In the future, when analyzing the connectivity of species including wild boar, it is judged that it will be effective to use movement data on actual species.