• Title/Summary/Keyword: Circuit analysis

Search Result 3,952, Processing Time 0.038 seconds

A Study on the ZVS-SEPP Type High Frequency Resonant Inverter with induction Heating Jar(I) (IH-Jar용 ZVS-SEPP 고주파 공진 인버터에 관한 연구(I))

  • Kim, Jong-Hae;Kim, Dong-Hee;No, Chae-Gyan;Bae, Young-Ho;Baek, Seung-Myun;Moon, Chang-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.2
    • /
    • pp.69-74
    • /
    • 1999
  • This paper presents about a example of circuit design and characteristics of proposed circuit in the case of adopted the high frequency resonant Inverter of SEPP type using ZVS(Zero-Voltage-Switching) to the Induction heating load. The soft switching technology known as ZVS is used to reduce turn on and off loss at switching. Also, this paper realizes quantitative circuit analysis which has change the equivalent of Induction heating load to the electric circuit. According to the calculated characteristics value, a method of the circuit designs and operation characteristics of the Inverter is proposed. In addition, this paper proves the propriety of theoretical analysis through the experiment. The proposed inverter shows it can be practically used as power source system for induction heating Jar etc.

  • PDF

New DC/AC Soft Switched PWM Converter Having a DC-Link Commutation Circuit (직류측에 Commutation 회로를 갖는 영전압 스위칭 PWM 인버터)

  • Chung, J.H.;Park, S.S.;Goo, T.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1158-1160
    • /
    • 1992
  • A new dc/ac soft switched PWM convert having a dc-link commutation circuit is proposed. The commutation circuit implemented by utilizing a series resonant circuit while preparing for zero voltage switching of primary inverter. The converter provides both variable pulse width and position which is fundamentally different than converters. In this paper, the operating principles, design and control considerations analysis of a such a soft switched converter is analyzed.

  • PDF

Computer Generation of Equivalent Circuit for Unit Cell of LCD-TV

  • Yoon, Suk-In;Jung, Chan-Yong;Won, Tae-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.739-742
    • /
    • 2006
  • In this paper, we propose a method for automatic generation of equivalent circuit for unit cell of LCDTV. In order to extract a circuit model, computer program generates electrical connectivity of resistors and capacitors from the layout through pattern analysis with electrode and port information. For combining two types of independent equivalent circuits, we propose a node insertion algorithm. As a consequence, we can generate an equivalent RC circuit without increasing the capacitive elements.

  • PDF

Analysis of the 74LS381 ALU and Design of an Equivalent Circuit to the 74L (74LS381 ALU의 분석 및 등가회로의 설계)

  • Lee, Jae-Seok;Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.153-156
    • /
    • 2001
  • This paper analyzes the 74LS381 ALU and designs its equivalent circuit. The 74LS381 ALU is arithmetic logic units(ALUs)/function generators that perform eight binary arithmetic/logic operations on two 4-bit words. However there are only little information to understand and design this circuit. Thus, we not only analyzed it but also designed an equivalent circuit to the 74LS381.

  • PDF

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

Analysis of Characteristics in Transformer by using Coupling Coefficient Type Equivalent Circuit (결합계수형 등가회로에 의한 변압기의 특성해석)

  • 이광직;김주홍
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.86-92
    • /
    • 1995
  • In the analysis of characteristic behaviors of a real transformer with coupling coefficient K is less than 1, this paper presents the more accurate and practical profits than the traditional analysis of the transformer treated as K∼1. This results from the use of the coupling coefficient type equivalent circuit of the transformer which includes K as positive parameter. Furthermore, a leakage transformer is analyzed in a unified method and the results of analysis are consistent with the practical measurements of the transformer. By using the above equivalent circuit, the characteristics referred to the load side are expressed as Thevenin voltage source and the leakage inductor (1-K2)L2. Therefore, these analysis about the output voltage and the damping factor in the transient state which are affected by the leakage inductor are confirmed to be an effective method.

  • PDF

A Study on the Induction Heating Analysis of Round bar for TR forging (TR단조를 위한 환봉의 유도가열 해석에 관한 연구)

  • Song, M.C.;Park, D.S.;Lee, M.G.;Lee, K.B.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.194-197
    • /
    • 2009
  • The TR forging is a kind of continuous grain flow forging. The preform of crank shaft for TR forging process was a round bar with a ring groove. In the first stage, the preform was partly heated by induction heating and then forged by vertical and horizontal force in sequence. In this study, the simulation process of induction heating was proposed to evaluate the temperature distribution of preform for TR forging. The equivalent circuit method was adopted to find coil current of the preform with a various dimensions and power levels. With these results, the coupled electromagnetic and transient thermal analysis for induction heating was performed to evaluate the temperature distribution at the preform of crank shaft during induction heating process. This FE analysis technique with equivalent circuit method was verified by comparing the analysis results with the experimental results.

  • PDF

Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters (단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석)

  • 강규홍;홍정표
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.

Analysis of Hot Gas Flew Considering Arc-Flow Interaction (아크플라즈마와 유동간의 상호작용을 고려한 열가스 유동 해석)

  • Kim, Hong-Gyu;Park, Gyeong-Yeop;Bae, Chae-Yun;Jo, Gyeong-Yeon;Jeong, Hyeon-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.3
    • /
    • pp.107-115
    • /
    • 2002
  • This parer presents the analysis of hot gas flow in puffer-type circuit breakers using FVFLIC method. For the analysis of arc-flow interaction, the flow field is analyzed from the equations of conservation for mass, momentum and energy with the assumption of local thermodynamic equilibrium state. The arc is represented as the energy source term composed of ohmic heating and radiation term in the energy conservation equation. Ohmic heating is computed by the electric field analysis only within the conducting plasma region. An approximate radiation transport model is employed for the evaluation of emission and absorption of the radiation. The analysis method was applied to the real circuit breaker model and simulation results such as pressure rise and arc voltage were compared with the experimental ones.

The Permeance Estimation and Characteristic Analysis of the Hybrid Stepping Motors Considering the Saturation (Hybrid Stepping Motor의 포화를 고려한 퍼미언스 산정 및 특성해석)

  • Woo, Joon-Keun;Lim, Ki-Chae;Hong, Jung-Pyo;Kim, Kyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.885-887
    • /
    • 2000
  • The paper proposes the characteristic analysis method to consider the saturation of teeth and poles in the hybrid stepping motors. The proposed method is based on the equivalent magnetic circuit coupling with the finite element analysis. The equivalent magnetic circuit is used to analysis the characteristics of the hybrid stepping motors. And the FE analysis is used to compute the non-linear parameters included the equivalent magnetic circuit in the hybrid stepping motors. Simulation and experiment results show that the proposed technique is compared with the classical method.

  • PDF