• Title/Summary/Keyword: Cine

Search Result 99, Processing Time 0.029 seconds

Anesthetic efficacy in vital asymptomatic teeth using different local anesthetics: a systematic review with network meta-analysis

  • Amy Kia Cheen Liew;Yi-Chun Yeh ;Dalia Abdullah ;Yu-Kang Tu
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.41.1-41.23
    • /
    • 2021
  • Objectives: This study aimed to evaluate the efficacy of various local anesthesia (LA) in vital asymptomatic teeth. Materials and Methods: Randomized controlled trials comparing pulpal anesthesia of various LA on vital asymptomatic teeth were included in this review. Searches were conducted in the Cochrane CENTRAL, MEDLINE (via PubMed), EMBASE, ClinicalTrials.gov, Google Scholar and 3 field-specific journals from inception to May 3, 2019. Study selection, data extraction, and risk of bias assessment using Cochrane Risk of Bias Tool were done by 2 independent reviewers in duplicate. Network meta-analysis (NMA) was performed within the frequentist setting using STATA 15.0. The LA was ranked, and the surface under the cumulative ranking (SUCRA) line was plotted. The confidence of the NMA estimates was assessed using the CINeMA web application. Results: The literature search yielded 1,678 potentially eligible reports, but only 42 were included in this review. For maxillary buccal infiltration, articaine 4% with epinephrine 1:100,000 was more efficacious than lidocaine 2% with epinephrine 1:100,000 (odds ratio, 2.11; 95% confidence interval, 1.14-3.89). For mandibular buccal infiltration, articaine 4% with epinephrine 1:100,000 was more efficacious than various lidocaine solutions. The SUCRA ranking was highest for articaine 4% with epinephrine when used as maxillary and mandibular buccal infiltrations, and lidocaine 2% with epinephrine 1:80,000 when used as inferior alveolar nerve block. Inconsistency and imprecision were detected in some of the NMA estimates. Conclusions: Articaine 4% with epinephrine is superior when maxillary or mandibular infiltration is required in vital asymptomatic teeth.

Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols (장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교)

  • Ko, Jeong Min;Jung, Jung Im;Lee, Bae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.83-90
    • /
    • 2013
  • Purpose : To report our clinical experience with cardiac 3.0 T MRI in patients compared with 1.5 T using individually optimized imaging protocols. Materials and Methods: We retrospectively reviewed 30 consecutive patients and 20 consecutive patients who underwent 1.5 T and 3 T cardiac MRI within 10 months. A comparison study was performed by measuring the signal-to-noise ratio (SNR), the contrast-to-noise ratio (CNR) and the image quality (by grading each sequence on a 5-point scale, regarding the presence of artifacts). Results: In morphologic and viability studies, the use of 3.0 T provided increase of the baseline SNRs and CNRs, respectively (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p = 0.068, CNR 18%, p = 0.059; viability imaging: SNR 45%, p = 0.017, CNR 37%, p = 0.135) without significant impairment of the image quality (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p = 0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p = 0.744; viability imaging: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p = 0.254). Although the image qualities of 3.0 T functional cine images were slightly lower than those of 1.5 T images ($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001), the mean SNR and CNR at 3.0 T were significantly improved (SNR 143% increase, CNR 108% increase, p < 0.001). With our imaging protocol for 3.0 T perfusion imaging, there was an insignificant decrease in the SNR (11% decrease, p = 0.172) and CNR (7% decrease, p = 0.638). However, the overall image quality was significantly improved ($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p = 0.006). Conclusion: With our experience, 3.0 T MRI was shown to be feasible for the routine assessment of cardiac imaging.

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

First-pass Stress Perfusion MR Imaging Findings of Apical Hypertrophic Cardiomyopathy: with Relation to LV Wall Thickness and Late Gadolinium-enhancement (심첨형 비후성 심근병증에서의 스트레스 부하 관류 자기공명영상 소견: 좌심실 벽 비후 정도와 지연 조영 증강 간의 관련성)

  • Yoo, Jin Young;Chun, Eun Ju;Kim, Yeo-Koon;Choi, Sang Il;Choi, Dong-Ju
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.7-16
    • /
    • 2014
  • Purpose : To evaluate the prevalence and pattern of perfusion defect (PD) on first-pass stress perfusion MR imaging in relation with the degree of left ventricular hypertrophy (LVH) and late gadolinium-enhancement (LGE) in patients with apical hypertrophic cardiomyopathy (APH). Materials and Methods: Cardiac MR imaging with first-pass stress perfusion, cine, and LGE sequence was performed in 26 patients with APH from January 2008 to December 2012. We analyzed a total of 416 segments for LV wall thickness on end-diastolic phase of cine images, and evaluated the number of hypertrophied segment and number of consecutive hypertrophied segment (NCH). We assessed the presence or absence of PD and LGE from all patients. If there was PD, we subdivided the pattern into sporadic (sporadic-PD) or ring (ring-PD). Using univariate logistic method, we obtained the independent predictor for presence of overall PD and ring-PD. Results: PD on stress perfusion MRI was observed in 20 patients (76.9%), 12 of them (60%) showed ring-PD. Maximal LV wall thickness and number of hypertrophied segment were independent predictors for overall PD (all, p < 0.05). NCH with more than 3 segments was an additional independent factor for ring-PD. However, LGE was not statistically related with PD in patients with APH. Conclusion: About three quarters of the patients with APH showed PD, most of them represented as ring-PD. LVH degree or distribution was related with pattern of PD, however, LGE was not related with PD. Therefore, the clinical significance of PD in the patients with APH seems to be different from those with non-APH, and further comparison study between the two groups should be carried out.

Comparison of Operator Radiation Exposure Dose undergoing Cardiac Angiography and Cardiac Intervention (심장혈관 중재적 시술의 시술자 피폭 선량에 관한 연구)

  • Kim, Jungsu;Kwon, Soonmu;Jung, Haekyoung;Lee, Bongki;Ryu, Dongryeol;Kwon, Hoseok;Cho, Byungryul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.181-186
    • /
    • 2016
  • Cardiac angiography(CA) or cardiac intervention(CI) is one of the major examination methods applied to the detection of cardiovascular diseases using X-rays. These CA and CI procedures require radiation exposure to patients and physicians. We evaluated the radiation dose to cardiac operator during the each case of CA and CI procedures. The number of patients is 113 patients in CA and 34 patients in CI. Mean fluoroscopy time, mean cine time, and mean total cumulative dose area product(DAP) in patients during CA and CI was 165.9 sec vs. 1200.0 sec, 30.31 sec vs 107.5 sec, and $37130.3mGy.cm^2$ vs $213312.6mGy.cm^2$, respectively. Mean dose of thyroid, over chest apron and under chest apron in operator during CA and CI was 15.84 uSv vs 89.81 uSv, 20.16 uSv vs 123.20 uSv, and 0.30 uSv vs 2.40 uSv, respectively. Mean effective dose of operator during CI was about 6 times greater than during CA. Also there was significant inter-relationship between fluoroscopy or cine time and effective dose in operator during CA and CI(p=0.001 and p=0.001, respectively).

Playing Trauma -A Study on the Representation of History in Taiwan Horror Game Detention (플레잉 트라우마 -대만 호러게임 <반교>의 역사 재현 연구)

  • Bae, Ju-Yeon
    • Journal of Popular Narrative
    • /
    • v.26 no.2
    • /
    • pp.87-122
    • /
    • 2020
  • This study explores the method of representation of traumatic history in 2D horror game Detention developed by Taiwan game production company Red Candle through an analysis of its method of storytelling. Unlike conventional public media, video/digital games are based on interactivity, in which game players engage in the narratives. Thus, the relationship between players and the history in the game world may also change. This research investigates how the players build their way of remembering and recognizing the past in a different relationship. Detention, which was well received, not only in Taiwan but also around the world upon its launch in 2017, is set in a middle school during the martial law era in Taiwan in the 1960s. In the game, the main character encounters her lost memories in the process of following clues and game rules, and finally realizes she is implicated in the 1960s' event. Detention was cinematized after the success of the game. The film achieved enormous popularity both in terms of box office success and criticism. In this paper, the strategy of the game's storytelling is introduced in comparison to the film's approach in the representation of historical events. In particular, the paper explores elements such as the interactivity of the game medium, narrative fragmentation, quests, hints and cues, and the horror genre, that asks users to understand history beyond the game world differently from the point of view of other media. Though this study, it can be considered that the digital game is a medium exploring history in a serious manner. In particular, Detention invokes the matter of game-mnemonics as well as cine-mnemonics. Compared to plentiful research in cine-mnemonics, game-mnemonics has not been extensively studied to date. Therefore, through the analysis of Detention, this paper explores the relationship between digital games, history and memory.

Diffusion Tensor Imaging and Cerebrospinal Fluid Flow Study of Cine Phase Contrast in Normal Cervical Spinal Cords (정상인 경수에 대한 확산텐서영상과 PC기법을 이용한 뇌척수액 속도 측정에 관한 연구)

  • Son, B.K.;Kwak, S.Y.;Han, Y.H.;Yoo, J.S.;Kim, O.H.;Ko, H.Y.;Mun, C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.123-132
    • /
    • 2013
  • Purpose : We report the results of the various parameters of diffusion tensor imaging (DTI) and CSF flow study of the cervical spinal cord using magnetic resonance (MR) imaging techniques. Materials and Methods: Intramedullary FA and MD were measured in the gray matter and posterior cord of the white matter and both lateral cords of the white matter at the C2-3, C4-5, C5-6 spinal levels. For the CSF flow study, velocity encoding was obtained at the C2-3, C4-5, C5-6 spinal levels. Results: There was a significant difference of the FA and MD between the white matter and gray matter (p < 0.05). The FA of the gray matter was significantly different according to the cervical spinal cord levels (p < 0.05). Otherwise, the FA and MD parameters were not significantly different (p > 0.05). The mean peak systolic velocity and mean peak diastolic velocity were $5.18{\pm}2.00cm/sec$ and $-7.32{\pm}3.18cm/sec$, respectively from C2 to C6 spinal cords. There was no significant difference in these velocities among the cervical spinal cord (p > 0.05). Conclusion: This basic information about DTI and CSF dynamics of the cervical spinal cord may be useful for assessing cervical spinal cord abnormalities using MR imaging.

High Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS (k-t FOCUSS 알고리듬을 이용한 고분해능 4-D MR 혈관 조영 영상 기법)

  • Jung, Hong;Kim, Eung-Yeop;Ye, Jong-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.10-20
    • /
    • 2010
  • Purpose : Recently, the Recon Challenge at the 2009 ISMRM workshop on Data Sampling and Image Reconstruction at Sedona, Arizona was held to evaluate feasibility of highly accelerated acquisition of time resolved contrast enhanced MR angiography. This paper provides the step-by-step description of the winning results of k-t FOCUSS in this competition. Materials and Methods : In previous works, we proved that k-t FOCUSS algorithm successfully solves the compressed sensing problem even for less sparse cardiac cine applications. Therefore, using k-t FOCUSS, very accurate time resolved contrast enhanced MR angiography can be reconstructed. Accelerated radial trajectory data were synthetized from X-ray cerebral angiography images and provided by the organizing committee, and radiologists double blindly evaluated each reconstruction result with respect to the ground-truth data. Results : The reconstructed results at various acceleration factors demonstrate that each components of compressed sensing, such as sparsifying transform and incoherent sampling patterns, etc can have profound effects on the final reconstruction results. Conclusion : From reconstructed results, we see that the compressed sensing dynamic MR imaging algorithm, k-t FOCUSS enables high resolution time resolved contrast enhanced MR angiography.

An Semiotic analysis on Spirited Away (애니메이션(센과 치히로의 행방불명)에 대한 기호학적분석)

  • Lee Yun-Hui
    • Broadcasting and Media Magazine
    • /
    • v.10 no.1
    • /
    • pp.99-112
    • /
    • 2005
  • Christian Metz, the precursor of cine-semiology, considered cinema as a language in the sense that it is a set of messages grounded in a given matter of expression, and a signifying practice characterized by specific codifications. According to Metz, film forms a structured network produced by the interweaving of cinematic codes, within which cinematic subcodes represent specific usages of the particular code. For Metz, cinematic language is a totality of cinematic codes and subcodes, and history of the cinema is the trace of the competition, incorporations and exclusions of the subcodes. He also suggested a filmic text is not just a list of codes in effect, but a process of constant displacement and deformation of codes. Following Metz' textual analysis methodology, I investigated the formal configuration of Hayao Miyazaki‘s animation, Spirited Away. It is interesting to trace the interweaving of cinematic codes in Spirited Away, i.e. codes of lighting, color, movement, and auteurism, across the animation. I focused on the first scene at the bridge to Yubaba's bathhouse, analyzing each cinematic code and its subcode applied. The first bridge scene is carefully constructed to stand out the confrontation of Chihiro (with Haku) and the bathhouse. The bathhouse is not just a building, it represents the powerful witch, Yubaba, yet to appear on the scene, and functions as an antipode to Chihiro. In each shot, every subcode within the codes of framing, direction, angle, color, lighting and movement is used to maximize the contrast between the dominant bathhouse and the feeble 10-year-old girl. In Spirited Away, the subcodes within each cinematic ode are constantly competing and displacing each other to augment the antithesis between the characters and develop the narrative. As Metz's argument that film constitutes a quasi-linguistic practice as a pluricodic medium, Spirited Away communicates with the spectators with the combination and displacement of these cinematic codes and subcodes.

Proteolytic Conditions for the Hydrolysate of Flounder Skin Gelatin (효소에 의한 가자미피 젤라틴 가수분해물의 제조 조건)

  • 강태중;양현필;김세권;송대진
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.21 no.4
    • /
    • pp.398-406
    • /
    • 1992
  • In order to develop a new flavourant using the fish skin gelatin, the proteolytic renditions for the gelatin hydrolysate of the alkali (B-type) and Alcalase (E-type) pretreated flounder (Limanda aspera) skin gelatin were investigated, and some physical properties, molecular weight and amino acid compositions of the hydrolysates were, also, compared with each other. The proteolytic conditions of the gelatins (B-type and E-type) by trypsin were as follows : reaction temperature, 55$^{\circ}C$ : pH, 9.0 : enzyme concentration, 0.1% : re-action time, 4hrs for B-type and 1 hr for E-type. The degrees of hydrolysis of the B-type and E-type gelatin un-der the renditions stated above were 63% and 82%, respectively. The rnajor molecular weights of the hydrolysates were 15,000 dalton for B-type and 12,400 dalton for E-type. Among the amino acids in the hydrolysates, glycine, alanine, proline, hydroxyproline and serine having a sweet taste were responsible for 57% of the total amino acid. But valine, leucine, phenylalanine, tyrosine, methionine, arginine and histidine having a bitter taste were only 18%.

  • PDF