• Title/Summary/Keyword: Cie

Search Result 953, Processing Time 0.026 seconds

Cr-doped Tialite Pigments (크롬을 사용한 Tialite계 안료)

  • Kim, Yeon-Ju;Lee, Byung-Ha
    • Korean Journal of Materials Research
    • /
    • v.21 no.9
    • /
    • pp.515-519
    • /
    • 2011
  • The purpose of this study was to determine the optimal firing condition and composition for $Al_2TiO_5$ crystal, which is suitable for stable coloration in glazes at high temperatures, using $Cr_2O_3$ as chromophore for the synthesis of $Al_2TiO_5$ system pigments. $Al_2TiO_5$ has a high refractive index and good solubility of chromophore in the $Al_2TiO_5$ lattice, making this structure a good candidate for the development of new ceramic pigments. Pigments were synthesized by using $Al_2O_3$ and $TiO_2$ mainly. Various amounts of $Cr_2O_3$ such as 0.01, 0.02, 0.03, 0.04 and 0.05 mole were also added. Each compound was synthesized at $1300^{\circ}C$, $1400^{\circ}C$, and $1500^{\circ}C$ for 2 hours and cooled naturally. The crystal structure, solubility limit, and color of the synthesized pigments were analyzed by XRD, SEM, Raman spectroscopy, UV and UV-vis. The changes in color as the result of applying 6 wt% of the synthesized pigments to lime barium glaze were expressed as CIE-L*a*b* values. A $Cr_2O_3$ 0.03 mole doped $Al_2TiO_5$ brown pigment was successfully synthesize at $1400^{\circ}C$, and the values of CIE-L*a*b* parameters were L* = 44.62, a* = 3.10, and b* = 17.25. In the case of the pigment synthesized at $1500^{\circ}C$, the brown color was obtained at 0.01 mole and 0.02 mole $Cr_2O_3$, and the CIE-L*a*b* values were 55.34, 1.73, 28.64, and 49.39, 0.51, 21.33, respectively. At $1500^{\circ}C$, the maximum limit of solid solution was 0.03 mole $Cr_2O_3$. The glazed sample showed green color, and the values of the CIEL* a*b* parameters were L* = 45.69, a* = -0.98, and b* = 20.38.

Supplementary Feeding of Economas E® Improves Storage Life of Hanwoo Beef

  • Mbiriri, David Tinotenda;Lee, Do-Hyeong;Oh, Seong-Jin;Kim, Young-Hoon;Cho, Sangbuem;Choi, Nag-Jin
    • Journal of Animal Science and Technology
    • /
    • v.55 no.6
    • /
    • pp.531-537
    • /
    • 2013
  • Vitamin E has been applied as a dietary supplement or post mortem to meat cuts to preserve meat quality and extend shelf life. This study was conducted to determine the effects of supplementation of the diet of Hanwoo steers with Economas $E^{(R)}$, a less expensive alternative to vitamin E, on meat quality preservation. To accomplish this, 36 Hanwoo steers were randomly allotted into three treatment groups ; no additive (control), Economas $E^{(R)}$(T1) and vitamin E (T2). Vitamin E and Economas $E^{(R)}$ were included in the diets at 500 mg/head and 200 mg/head, respectively, for 5 months. Evaluation of carcass performance parameters immediately after slaughter revealed no treatment effects (P>0.05). Samples collected from the loin area and stored at $4^{\circ}C$ for up to 9 days showed that T1 and T2 preserved pigment and lipid stability as indicated by significantly (P<0.05) higher CIE $L^*$ and lower CIE $a^*$ and CIE $b^*$ values and a less rapid increase in thiobarbituric acid reactive substance (TBARS) relative to the control. However, treatments had no effect (P>0.05) on cholesterol and fatty acid content in meat. Based on these findings, Economas $E^{(R)}$ provided at 200 mg/head is as effective as vitamin E applied at 500 mg/head at preserving Hanwoo meat quality over a 9 day storage period at $4^{\circ}C$.

Comparative Study of Tongue Color in Common Cold Patients and Controls (감기 환자와 건강대조군 간의 설 특성 비교연구)

  • Kim, Ji Hye;Joo, Jong Cheon;Park, Soo Jung;Kim, Keun Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.5
    • /
    • pp.320-326
    • /
    • 2016
  • Tongue diagnosis is convenient and non-invasive method to examine the body's functional condition, and it has been frequently used in traditional Korean Medicine (KM). The aim of this study was to investigate the difference of the tongue color assessed by computerized tongue image analysis system (CTIS) between the common cold (CC) patients and healthy subjects. A total of 85 participants, including 45 CC patients without organic diseases and 40 healthy subjects, were asked to complete the CC symptom questionnaire. A tongue image was acquired by using CTIS. Color differences in Commission Internationale de l'Eclairage (CIE) L*, a* and b* between the CC patient group and the control group were analyzes by using paired t-test analysis. The variable CIE b* of the tongue body was significantly lower in CC than that in controls (P=0.019). The variable CIE L* of the tongue coating was significantly higher in CC than that in controls (P=0.032). In CC, the color of the tongue body seems to be changed to intense red color. The color of the tongue coating seems to be changed to thick fur. The present study demonstrated that the CTIS can be used as a diagnostic and monitoring tool for the objective and standardized evaluation of common cold in clinics.

Presentation of Target Color with Extraction Variables in Natural Dyes Extraction (천연색소 추출공정에서 추출특성에 따른 목표색의 재현)

  • Tak, Eun-Soo;Bae, Min-Woo;Kang, Seung-Hyeon;Bae, You-Jin;Kang, Su-Yeon;Jung, Soo-Kyung;Hong, In-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.559-563
    • /
    • 2010
  • The representation of color with natural dyes is closely related with the modern well-being life. This study is focused on the representation of target color of the blue, yellow, and red color system, these color sources were originated from the green tea, gardenia, and black rice respectively. The quantitative numerical value of brightness (L), color coordinates (a, b) were designated for the target color, the optimum color nearest to the target value was extracted with the solvent pH, temperature, and extraction time. The longer the extraction time had more thickening color in case of the gardenia. The L-a-b coordinate of extracted color were analyzed with the color difference meter and compared with the target color. The experimental variables were optimized to extract the color of the smallest ${\Delta}E$ with the target color. As a result, the CIE standard value was proposed and the color was represented.

Selection of Beef Quality Factors Represented by Time-Temperature Integrator (TTI)

  • Kim, Eun-Ji;Kim, Kee-Hyuk;Jung, Seung-Won;Chung, Ku-Young;Lee, Seung-Ju
    • Food Science of Animal Resources
    • /
    • v.32 no.5
    • /
    • pp.598-603
    • /
    • 2012
  • Beef qualities which can be properly predicted by time-temperature integrator (TTI), a chromatic indicator, were selected in terms of its similarity of temperature dependence between beef qualities and TTI, denoted by Arrhenius activation energy ($E_a$). The high similarity is required to afford accurate prediction. A devised enzymatic TTI based on laccase (an oxidase), which catalyses the oxidation on 2,2'-azino-bis-(3-ethylbenzothiazoline-6-sulphonic acid) producing color development, was applied. The factors of beef quality, such as volatile basic nitrogen (VBN), pH, color (CIE $L^*$, $a^*$), Warner-Bratzler shear force (WBSF), Pseudomonas spp. count, and lactic acid bacteria (LAB) count were considered for the selection. $E_a$ (55.48 kJ/mol) of the TTI was found to be similar to those of the beef qualities (all referred) in the order of LAB count (53.54 kJ/mol), CIE $a^*$ value (61.86 kJ/mol), pH (65.51 kJ/mol), Pseudomonas spp. Count (44.54 kJ/mol), VBN (67.98 kJ/mol), WBSF (40.67 kJ/mol), and CIE $L^*$ value (33.72 kJ/mol). The beef qualities with more similar $E_a$ to that of the TTI showed less difference between real and TTI predicted levels. In conclusion, it was found out that when applying TTI to food packages, their $E_a$ similarity should be checked to assure accurate estimation of food quality levels from TTI response.

Fabrication and Characterization of Yellow OLED using GDI602:Rubrene(10%) Material (GDI 602/Rubrene을 이용한 황색 OLED의 제작과 특성 분석)

  • Jang, Ji-Geun;Kim, Hee-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.4
    • /
    • pp.71-75
    • /
    • 2006
  • The yellow emitting OLED using GDI602:Rubrene(10%) material has been fabricated and characterized. In the device fabrication, 2-TNATA [4,4',4'-tris(2-naphthylphenyl-phenylamino)-triphenyl-amine] as a hole injection material and NPB[N,N'-bis(1-naphthyl)-N,N'-diphenyl-1,1'-biphenyl -4,4'-diamine] as a hole transport material were deposited on the ITO(indium thin oxide)/glass substrate by vacuum evaporation. And then, yellow emission material was deposited using GDI602 as a host material and Rubrene(10%) as a dopant. Finally, small molecular OLED with the structure of $ITO/2-TNATA/NPB/GDI602:Rubrene(10%)/Alq_{3}/LiF/Al$ was obtained by in-situ successive deposition of $Alq_{3}$, LiF and Al as the electron transport material, electron injection material and cathode. The yellow OLED fabricated in our experiments showed the color coordinate of CIE(0.50, 0.49), the luminance of $2300\;Cd/m^{2}$ and the power efficiency of 0.7 lm/W at 10 V with the peak emission wavelength of 562 nm.

  • PDF

Luminescence Characteristics of Blue and Yellow Phosphor for Near-Ultraviolet (자외선 여기용 청색 및 황색 형광체의 발광특성)

  • Choi, Kyoung-Jae;Park, Joung-Kyu;Kim, Kyung-Nam;Kim, Chang-Hae;Kim, Ho-Kun
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.5 s.288
    • /
    • pp.304-308
    • /
    • 2006
  • We have synthesized a $Eu^{2+}-activated\;Sr_3MgSi_2O_8$ blue phosphor and $(Sr,Ba)_2SiO_4$ yellow phosphor and prepared white LEDs by combining these phosphors with a InGaN UV LED chip. Three distinct emission bands from the InGaN-based LED and the two phosphors are clearly observed at 405 nm, 460 nm and at around 560 nm, respectively. The 405 nm emission band is due to a radiative recombination from a InGaN active layer. This blue emission was used as an optical transition of the $Sr_3MgSi_2O_8:Eu$ blue phosphor and $(Sr,Ba)_2SiO_4:Eu$ yellow phosphor. The 460 nm and 560 nm emission band is ascribed to a radiative recombination of $Eu^{2+}$ impurity ions in the $Sr_3MgSi_2O_8:Eu$ and $(Sr,Ba)_2SiO_4$ host matrix. As a consequence of a preparation of UV White LED lamp using the $Sr_3MgSi_2O_8:Eu$ blue phosphor and $(Sr,Ba)_2SiO_4:Eu$ yellow phosphor, the highest luminescence efficiency was obtained at the ration of epoxy/two phosphor (1/0.2361). At this time, the CIE chromaticity was CIE x = 0.3140, CIE y = 0.3201 and CCT (6500 K).

Color Look-Up Table Design for Gamut Mapping and Color Space Conversion (색역 사상과 색공간 변환을 위한 칼라 참조표 설계)

  • 김윤태;조양호;이호근;하영호
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.2
    • /
    • pp.1-10
    • /
    • 2004
  • This paper proposes the method that design CLUT(color look-up table) simultaneously processing gamut mapping and color space conversion using only CLUT without complex computation. After CLUT is constructed using scanner gamut and printer gamut, the scanner gamut is extended to include original scanner gamut. This extended scanner gamut is used as input CIE $L^{*}$ $a^{*}$ $b^{*}$ values for CLUT. Then CMY values are computed by using gamut mapping. Input RGB image of scanner is converted into CIE $L^{*}$ $a^{*}$ $b^{*}$ by using regression function. CIE $L^{*}$ $a^{*}$ $b^{*}$ values of scanner are converted into CMY values without computation of additional gamut mapping using the proposed CLUT. In the experiments, the proposed method resulted in the similar color difference, but reduced the complexity computation than the direct computing method to process gamut mapping and color space conversion respectively.espectively.ively.

Effect of the amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics

  • Kim, Hee-Kyung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.37-42
    • /
    • 2016
  • PURPOSE. This study investigated the effect of amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics. MATERIALS AND METHODS. One-hundred sixty-five monolithic zirconia specimens ($16.3mm{\times}16.3mm{\times}2.0mm$) were divided into 5 groups (Group I to V) according to the number of A2-coloring liquid applications. Each group was then divided into 11 subgroups by reducing the thickness up to 1.0 mm in 0.1-mm increments (Subgroup 0 to 10, n=3). Colors and spectral distributions were measured according to CIELAB on a reflection spectrophotometer. All measurements were performed on five different areas of each specimen. Color difference (${\Delta}E^*{^_{ab}}$) and translucency parameter (TP) were calculated. Data were analyzed using one-way ANOVA and multiple comparison $Scheff{\acute{e}}$ test (${\alpha}=.05$). RESULTS. There were significant differences in CIE $L^*$ between Subgroup 0 and other subgroups in all groups. CIE $a^*$ increased (0.52<$R^2$<0.73), while CIE $b^*$ decreased (0.00<$R^2$<0.74) in all groups with increasing thickness reduction. Perceptible color differences (${\Delta}E^*{^_{ab}}$>3.7) were obtained between Subgroup 0 and other subgroups. TP values generally increased as the thickness reduction increased in all groups ($R^2$>0.89, P<.001). CONCLUSION. Increasing thickness reduction reduces lightness and increases a reddish, bluish appearance, and translucency of monolithic zirconia ceramics.

A Correction of Color Temperature and Consistency for 3D Stereoscopic Images (3D 입체영상을 위한 색온도와 색 일치 보정)

  • Kim, Jeong-Yeop;Kim, Sang-Hyun
    • The KIPS Transactions:PartB
    • /
    • v.18B no.3
    • /
    • pp.139-146
    • /
    • 2011
  • The color correction is the important process of influencing on the picture quality of the 3D stereoscopic images. Existing colorcorrecting methods handle the processing intensifying a correspondence among a left and right image using a histogram based on any one side. In case of color correction based on a histogram, it is difficult to correct tone of image, because the color temperature is not converted enough. And in this paper, the color temperature correction and color consistency correction is proposed without using histogram. The proposed color correction method by color temperature gives 3 in CIE-${\Delta}E$ for each pixel on the images captured with same illuminants and the conventional gives similar results. For color consistency, the proposed gives 9 in CIE-${\Delta}E$ on the images captured with different illuminants while the conventional gives 18. The proposed method shows better results than the conventional in color consistency processing.