Determination of Ratios of Natural Ingredients for Loess(Hwangtoh) as Environmental-Friendly materials (친환경 건축자재로서 황토마감재 개발을 위한 천연혼화재 비율설정에 관한 연구)

  • Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.51-57
    • /
    • 2006
  • With people's awareness of environment-friendly buildings recently increasing, there is a need to develop environment-friendly construction materials to reduce indoorair pollution levels. Thus, efforts to develop loess finishing materials that can replace the finishing materials currently being used (e.g., gypsum boards and chemical products) are underway. An analysis of the characteristics of domestic loess products,however, revealed that the cracks on loess products can be lessened and their strength can be improved by adding chemical ingredients to them. Thus, this research sought to use 100% natural materials and to develop loess finishing materials. In the experiments that were conducted in this study, appropriate mixture ratios of loess and sand/silica sand were found, and cracks and contraction ratio changes in samples were analyzed by differentiating the ratios of natural ingredients, such as lime, fine jute threads, gypsum, and jute cuttings. Loess'particle size distribution was found to have a high correlation with loess decoration, and it was discovered that the mixture of lime and fine chute threads could improve the contraction ratio. Through this study, which made use of natural ingredients, environment-friendly construction materials that can exercise the original function of loess were developed.

Numerical research for Gate Type Waste Incinerators In Environment energy facilities (환경에너지시설내 화격자식 소각로 수치해석 연구)

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.149-155
    • /
    • 2017
  • This study is analyzed combustion phenomena based on the environmental energy facility incinerator. It is assumed that combustible components of waste are composed of carbon and hydrogen, and the combustion process of fuel is by setting as multi-component / multistage reaction. As the combustion chamber is burned, the high temperature environment is achieved, also the heat transfer accompanied by the turbulent flow and the generation of NOx, a pollutant, are interpreted to predict the thermal and fluid characteristics and pollution emissions of the grate incinerator. As the result of internal flow analysis, the slow flow around the ash chute and the mixing effect due to the complicated turbulence around the combustion chamber were predicted to show excellent performance. It is shown to the internal average temperature was about $1024^{\circ}C$, around the about $1000^{\circ}C$ homogeneous temperature distribution. Due to the sudden temperature decrease in the boiler, the flue gas temperature at the outlet was estimated to be about $220^{\circ}C$.

Establishment of Condition Assessment Criteria in Agricultural Reservoirs by AHP (AHP 기법에 의한 농업용 저수지의 상태평가 기준 설정)

  • Shim, Jae-Woong;Lee, Young-Hak;Lee, Dal-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.5
    • /
    • pp.17-26
    • /
    • 2022
  • In this study, in order to establish the criteria for evaluation of importance by the type of facility specialized for agricultural reservoirs, an expert group consisting of a total of 167 members who were in management, or specialized in the fields of design, research, and diagnosis were organized, and the importance for facilities was set with application of the AHP technique. The importance of dam body, spillway, and intake structure composing a reservoir were set at 59%, 24%, and 17%, and the importance of dam crest, upstream slope, and downstream slope constituting a dam body was set at 32%, 31%, and 37%, respectively. In addition, the importance of approach channel, regulated channel, chute channel, and stilling basin consisting a spillway was set at 15%, 44%, 26%, and 15%, and the importance of inclined conduit and outlet conduit consisting an intake structure was set at 35% and 65%, respectively. The safety grade of the reservoirs evaluated by applying the newly presented importance values in this study showed the rearrangement of the grades with a change of 11% compared to the previous grades. In this way, the newly established criteria are expected to be utilized as basic data with strategic importance in reservoir safety management and disaster prevention as well as the operation of systems in the future.

A Study on Imposing Exact Solutions as Internal Boundary Conditions in Simulating Shallow-water Flows over a Step (계단을 지나는 천수 흐름의 모의에서 내부 경계조건으로서 정확해의 부여에 관한 연구)

  • Hwang, Seung-Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.479-492
    • /
    • 2014
  • In this study, was proposed a numerical scheme imposing exact solutions as the internal boundary conditions for the shallow-water flows over a discontinuous transverse structure such as a step. The HLLL approximate Riemann solver with the MUSCL was used for the test of the proposed scheme. Very good agreement was obtained between simulations and exact solutions for various problems of the shallow-water flows over a step. In addition, results by the numerical model showed good agreement with those of dam-break experiments over a step and stepped chute one. Developed model can simulate the shallow-water flows over discontinuous bottom such as a drop structure without additional rating curve or topography smoothing. Given the proper evaluations for the flow resistance by a step and the energy loss by the nappe flow in the future, could be simulated flooding and drying of the shallow-water flows over discontinuous topography such as a weir or the river road with retaining wall.

Numerical Modeling of Free Surface at the Fish Migration Spillways (어류 이동용 여수로의 자유수면 수치해석)

  • Lee, Hae-Gyun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.426-432
    • /
    • 2010
  • A level-set finite-element method is employed to investigate the free surface flow of two conceptual fish passage designs. While one design has a right-angled entrance from the reservoir to the fish passage chute, the other has a curved-shaped entrance. The numerical results are validated with hydraulic experiments through comparison of the free surface location and the pressure distribution in the spillway. It is observed that the right-angled design yields a curved free surface and pressure distribution in the vicinity of the entrance due to large strains, whereas the curved-shaped design yields a smooth flow transition with small strains. The subatmospheirc pressure distributions near the spillway ogee crest for both designs exhibit similar flow patterns. It is concluded that the curved-shaped design is more favorable for fish passage because of the feature of a smooth flow transition with small strains.

Durability and Performance Requirements in Canadian Cement and Concrete Standards (캐나다 시멘트 및 콘크리트의 내구성 및 제성능에 대한 규준)

  • Hooton, R.D.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.5-21
    • /
    • 2006
  • Traditional standards and specifications for concrete have largely been prescriptive, (or prescription-based), and can sometimes hinder innovation and in particular the use of more environmentally friendly concretes by requiring minimum cement contents and SCM replacement levels. In December 2004, the Canadian CSA A23.1-04 standard was issued which made provisions (a) for high-volume SCM concretes, (b) added new performance requirements for concrete, and (c) clearly outlined the requirements and responsibilities for use in performance-based concrete specifications. Also, in December 2003, the CSA A3000 Hydraulic Cement standard was revised. It (a) reclassified the types of cements based on performance requirements, with both Portland and blended cements meeting the same physical requirements, (b) allows the use of performance testing for assessing sulphate resistance of cementitious materials combinations, (c) includes an Annex D, which allows performance testing of new or non-traditional supplementary cementing materials. From a review of international concrete standards, it was found that one of the main concerns with performance specifications has been the lack of tests, or lack of confidence in existing tests, for judging all relevant performance concerns. Of currently used or available test methods for both fresh, hardened physical, and durability properties, it was found that although there may be no ideal testing solutions, there are a number of practical and useful tests available. Some of these were adopted in CSA A23.1-04, and it is likely that new performance tests will be added in future revisions. Other concerns with performance standards are the different perspectives on the point of testing for performance. Some concrete suppliers may prefer processes for both pre-qualifying the plant, and specific mixtures, followed only with testing only 'end-of-chute' fresh properties on-site. However, owners want to know the in-place performance of the concrete, especially with high-volume SCM concretes where placing and curing are important. Also, the contractor must be aware of, and share the responsibility for handling, constructability, curing, and scheduling issues that influence the in-place concrete properties.

  • PDF

Development of a Low-cost and High-efficiency Post-harvest Bulk Handling Machinery System of Onion - Performance Evaluation and Control

  • Park, Jongmin;Kim, Jongsoon;Jung, Hyunmo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.2
    • /
    • pp.61-69
    • /
    • 2020
  • As post-harvest processes of onions are carried by a 20 kg-net package which results in high-cost and low-efficiency, especially, the insufficient drying and physical damage of onions after harvesting leads to a huge second loss in storage, we had developed a low-cost, high-efficiency post-harvest bulk handling machinery system by collecting onions on a farm using ton-bags, drying with forced air circulation, and sorting/packaging. The post-harvest bulk handling machinery system consisted of 6 devices, and this study designed an automatic feed hopper with a feeding rate control device, an inclined belt conveyor with a two-step chute, and an automatic pallet unloading device for feeding onions into the sorting/packing line. This study also analyzed the performance and control of the total system. The device had 1-ton handling capacity, but the operational condition was set to increase the capacity. The three-step filling method of pallet by the velocity control of the inclined belt conveyor was applied in the post-harvest bulk handling machinery system for the prevention of physical damage. If one worker was set to operate the total system, the time required to complete one palletized load was approximately 5 minutes and 5 seconds. The calculated daily handling capacity was approximately 94 tons, when the daily actual working time was 8 hours. When the developed system was applied to the managerial size of 2,000 ton, the processing cost per ton of the system was decreased by 19.5%, compared with the existing 20 kg-net package-based handling. The developed post-harvest bulk handling machinery system would be a good substitute for the rapid decline and aging of rural labor.

Surgical Treatment for Granulosa Cell Tumor in a Thoroughbred Mare (말에서 Granulosa Cell Tumor에 의한 무발정 치료 예)

  • Seo, Jong-Pil;Son, Won-Gyun;Gang, Su-Jin;Kim, Hyung-Jin;Kim, Dae-Yong;Lee, Choung-Seop;Lee, In-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.26 no.5
    • /
    • pp.486-489
    • /
    • 2009
  • An 8-year-old Thoroughbred mare showing anestrus for longer than 6 months with left ovarian mass was referred to Veterinary Medical Teaching Hospital of Seoul National University. For 6 months, the mare had received 2 times hormonal therapies with $PGF_2{\alpha}$ and progesterone. The mare had not responded to these therapies and not shown estrous behavior. On rectal palpation, the left ovary was enlarged and contralateral ovary was small and inactive. Transrectal ultrasonographic examination of the left ovary revealed a mass composed of multiple, irregularly shaped follicles. Granulosa cell tumor (GCT) was suspected according to her history. Ovariectomy was performed through the left flank laparotomy with a standing position in a simple chute located outside of horse farm. The mass was diagnosed as GCT on histopathology. The mare was recovered without any problem and became pregnant next spring.

Spillway Design by Using Hydraulic and Numerical Model Experiment - Case Study of HwaBuk Multipurpose Dam (수리 및 수치모형실험을 이용한 여수로 설계 - 화북다목적댐)

  • Kim, Dae-Geun;Choi, Ji-Woong;Kim, Chang-Si;Lee, Ji-Won
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.179-188
    • /
    • 2005
  • This study on the HwaBuk Multipurpose Dam showed that two- and three- dimensional numerical model experiments, as well as hydraulic model experiments, can be useful analysis tools for engineers. A commercially available RMA2, which solves the shallow water equations, and FLOW-3D, which solves the Reynolds averaged Navier-Stokes equations, were used to simulate the hydraulic model setup. Numerical simulation results on the following were compared with the hydraulic model results: the flow in the reservoir basin and the approaching channel; the discharge in the overflow weir; the water surface profiles in the rollway, chute, and stilling basin; and the pressure distributions in the rollway. It was shown that there is a reasonably good agreement between the numerical model and the hydraulic model for the most of computations. There were, however, some differences between the numerical simulation results and hydraulic model results for the hydraulic jump in the stilling basin because of air entrainment effect.

Dorsal Track Control (DTC): A Modified Surgical Technique for Atraumatic Handling of the Distal Esophagus in Esophagojejunostomy

  • Lehwald-Tywuschik, Nadja;Steinfurth, Fabian;Kropil, Feride;Krieg, Andreas;Sarikaya, Hulya;Knoefel, Wolfram Trudo;Kruger, Martin;Benhidjeb, Tahar;Beshay, Morris;Esch, Jan Schulte am
    • Journal of Gastric Cancer
    • /
    • v.19 no.4
    • /
    • pp.473-483
    • /
    • 2019
  • Surgical therapy for adenocarcinoma of the esophagogastric junction II requires distal esophagectomy, in which a transhiatal management of the lower esophagus is critical. The 'dorsal track control' (DTC) maneuver presented here facilitates the atraumatic handling of the distal esophagus, in preparation for a circular-stapled esophagojejunostomy. It is based on a ventral semicircular incision in the distal esophagus, with an intact dorsal wall for traction control of the esophagus. The maneuver facilitates the proper placement of the purse-string suture, up to its tying (around the anvil), thus minimizing the manipulation of the remaining esophagus. Furthermore, the dorsally-exposed inner wall surface of the ventrally-opened esophagus serves as a guiding chute that eases anvil insertion into the esophageal lumen. We performed this novel technique in 21 cases, enabling a safe anastomosis up to 10 cm proximal to the Z-line. No anastomotic insufficiency was observed. The DTC technique improves high transhiatal esophagojejunostomy.