• 제목/요약/키워드: Chromium-hexavalent

검색결과 167건 처리시간 0.03초

도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구 (Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation)

  • 이병규;신용철
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

용해도에 따라 노출기준이 다른 금속화합물의 정량방법 고찰 (Review of the Determination Methods for Metal Compounds with Different Occupational Exposure Limits Depending on Solubility)

  • 박승현;노지원;장미연
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.87-98
    • /
    • 2020
  • Objective: The purpose of this study was to propose a sequential procedure for the simultaneous analysis of soluble and insoluble metal compounds. Methods: Methods for sampling and analyzing metal compounds such as ISO standards, NIOSH methods, HSE methods, and OSHA methods were reviewed. Results: Some metals have different OELs depending on the solubility of the compound. Therefore, we should take into account these characteristics and perform an exposure assessment. Soluble metal compounds are first extracted from the filter, and then the filter is digested by acids to analyze residual insoluble components. The extraction of soluble compounds can be completed by agitation for about 60 minutes with a leach solution (water) in a water bath at 37℃. For the analysis of insoluble compounds, the sample filter and the filtration filter remaining after the extraction of the soluble compounds are analyzed. This allows simultaneous determination of soluble and insoluble metal compounds. For hexavalent chromium compounds, soluble hexavalent chromium can first be extracted from the filter by using sulfate buffer. The insoluble hexavalent chromium remaining in the filter can then be extracted using carbonate buffer. Conclusion: Workers are often exposed to many hazardous substances with different exposure limits at industrial sites. The OELs for compounds of the same metal can be set differently depending on solubility. This study can help evaluate a worker's exposure to metal compounds by suggesting methods for the simultaneous determination of soluble and insoluble metal compounds.

Characteristics of a Novel Acinetobacter sp. and Its Kinetics in Hexavalent Chromium Bioreduction

  • M., Narayani;K., Vidya Shetty
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권5호
    • /
    • pp.690-698
    • /
    • 2012
  • Cr-B2, a Gram-negative hexavalent chromium [Cr(VI)] reducing bacteria, was isolated from the aerator water of an activated sludge process in the wastewater treatment facility of a dye and pigment based chemical industry. Cr-B2 exhibited a resistance for 1,100 mg/l Cr(VI) and, similarly, resistance against other heavy metal ions such as $Ni^{2+}$ (800 mg/l), $Cu^{2+}$ (600 mg/l), $Pb^{2+}$ (1,100 mg/l), $Cd^{2+}$ (350 mg/l), $ZN^{2+}$ (700 mg/l), and $Fe^{3+}$ (1,000 mg/l), and against selected antibiotics. Cr-B2 was observed to efficiently reduce 200 mg/l Cr(VI) completely in both nutrient and LB media, and could convert Cr(VI) to Cr(III) aerobically. Cr(VI) reduction kinetics followed allosteric enzyme kinetics. The $K_m$ values were found to be 43.11 mg/l for nutrient media and 38.05 mg/l for LB media. $V_{max}$ values of 13.17 mg/l/h and 12.53 mg/l/h were obtained for nutrient media and LB media, respectively, and the cooperativity coefficients (n) were found to be 8.47 and 3.49, respectively, indicating positive cooperativity in both cases. SEM analysis showed the formation of wrinkles and depressions in the cells when exposed to 800 mg/l Cr(VI) concentration. The organism was seen to exhibit pleomorphic behavior. Cr-B2 was identified on the basis of morphological, biochemical, and partial 16S rRNA gene sequencing chracterizations and found to be Acinetobacter sp.

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권4호
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

Effect of the Chemical Reduction by Ferrous ions on Chromate Toxicity to Daphnia magna

  • Park, Kyeong S.;Man B. Gu;Kim, Sang D.
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2001년도 춘계심포지움 및 학술발표회
    • /
    • pp.122-122
    • /
    • 2001
  • The reaction kinetics of hexavalent chromium with ferrous ions were studied to determine the influence of reduction on the toxicity of chromium to aquatic organisms. The changes in chemical forms of the chromate in the presence of ferrous ions were examined in a bioassay system using Dphnia magna as a test organism. (omitted)

  • PDF

모 조선업체 아크 용접 작업자의 공기중 6가 크롬 및 니켈 노출에 관한 연구 (Welder's Exposure to Airborne Hexavalent Chromium and Nickel during Arc Welding in a Shipyard)

  • 신용철;이광용;이나루;오세민;강성규;문영한;이기라
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.209-223
    • /
    • 1998
  • The aim of this study was to evaluate welders' exposure to hexavalent chromium (Cr(VI)) and nickel (Ni) during welding operations in a Korean shipyard. The airborne Cr(VI) and Ni concentrations were measured during metal inert gas (MIG) welding on mild and stainless steel, and manual metal arc (MMA) welding on mild steel. The geometric mean (GM) of Cr(VI) concentrations inside the welding helmet during MIG welding on mild steel were $0.0018mg/m^3$ inside a ship section, and $0.0015-0.0026mg/m^3$ at the welding shops. All of the personal breathing zone air samples were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$) of $0.01mg/m^3$. Conversely, eighty-eight percent(21 of 24) of the personal breathing zone air samples exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit of $0.001mg/m^3$. Ni was not detected on 20 of 23 air samples collected during MIG welding on mild steel. The three Ni samples above the limit of detection ranged from 0.015 to $0.044mg/m^3$. The GM of Cr(VI) concentrations during MMA welding on mild steel were $0.0013mg/m^3$, but Ni was not detected in the air samples during this operation. It is assumed that the airborne Cr(VI) and Ni during mild steel welding were derived from the base metals which contained about 0.03% Cr and 0.03% Ni. The GM of airborne total Cr, Cr(VI) and Ni concentrations during MIG welding on stainless steel were 4.02, 0.13 and $0.86mg/m^3$, respectively, and the levels of Cr(VI) and Ni were above the ACGIH-$TLV^{(R)}$. Cr(VI) comprised about 35.5% of the total chromium(Cr) from MIG welding on mild steel, and about 8.4% of total Cr from MIG welding on stainless steel. The ratios of Cr(VI) to total Cr were significantly different among welding shops. It was concluded that welders were exposed to high levels of Cr(VI) and Ni during welding on stainless steel, and were exposed to low levels of Cr(VI) even during welding on mild steel.

  • PDF

A Study of the Potential Interference of ArC+ on the Direct Determination of Trivalent Chromium and Hexavalent Chromium Using Ion Chromatography Coupled with ICP-MS

  • Nam, Sang-Ho;Park, Young-Il;Kim, Jae-Jin;Han, Sun-Ho;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권4호
    • /
    • pp.447-451
    • /
    • 2004
  • Low and high resolution inductively coupled plasma mass spectrometry (ICP-MS) coupled with ion chromatography (IC) has been investigated for speciation of Cr(III) and Cr(VI). In particular, the interference of ArC^+formed by the carbon in a sample on the simultaneous determination of Cr(III) and Cr(VI) has been studied. In chemical speciation, this study shows that quadrupole type ICP-MS with low resolution has a limitation of simultaneous determination fo chromium species if the sample contains the carbon elements. The interference problems can be solved by high resolution ICP-MS.

Redox Kinetics of Chromium(Ⅵ) in the Presence of Aquifer Materials Amended with Ferrous Iron

  • Hwang, Inseong;Batchelor, Bill
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.118-121
    • /
    • 2002
  • The kinetics and stoichiometry of the reduction of hexavalent chromium (Cr(Ⅵ)) with ferrous iron (Fe(II)) were examined in systems with and without aquifer solids. Cr(Ⅵ) reduction was rapid in the absence of solids, but demonstrated slower and more complex kinetics in the presence of aquifer solids. The aquifer solids removed Fe(II) from solution and a portion of the reducing capacity of Fe(II) was transferred to the aquifer solids. The solid phases were then able to continue to remove Cr(Ⅵ). This suggests in-situ treatment of Cr(Ⅵ) by Fe(II) injection would be feasible in the aquifer environment. In general, re-oxidation of reduced chromium by molecular oxygen was not observed in our systems over time periods of nearly one year.

  • PDF

6가크롬 노출에 따른 넙치, Paralichthys olivaceus의 혈액학적 성상 및 혈장성분의 변화 (Effects of Exposure to Hexavalent Chromium on Hematological Parameters and Plasma Components in Flatfish, Paralichthys olivaceus)

  • 김진영;성기현;임록지;서승아;조영록;김준환
    • 환경생물
    • /
    • 제36권2호
    • /
    • pp.124-130
    • /
    • 2018
  • 본 연구는 넙치 치어(평균 체장 $13.3{\pm}1.6cm$, 평균 체중 $25.6{\pm}3.7g$)를 수중 6가크롬에 10일간 0, 0.5,1.0, $2.0mg\;L^{-1}$의 농도로 노출시켜 독성영향 판단하기 위해 수행되었다. 넙치 hemoglobin과 hematocrit와 같은 혈액학적 성상은 수중 크롬노출에 의해 유의적으로 감소하였다. 혈장 무기성분인 calcium과 magnesium은 크롬노출에 의해 유의적인 변화는 나타나지 않았다. 혈장 무기성분인 glucose와 cholesterol과 같은 $1.0mg\;L^{-1}$ 이상의 크롬노출에 의해 유의적으로 증가하였지만, total protein은 유의적인 변화는 나타나지 않았다. 혈장 효소성분인 AST, ALT, ALP는 크롬노출에 의해 유의적인 증가가 나타났다. 본 실험의 결과는 수중 크롬노출은 넙치의 혈액 및 혈장성분에 유의적인 변화를 유발하며, 이러한 지표의 변화는 수중 크롬노출의 독성영향을 판단하는 주요한 지표가 될 것이다.