• 제목/요약/키워드: Chromium

검색결과 1,440건 처리시간 0.033초

크롬계 이중도금층 제조 및 특성평가 (Fabrication of Chromium-based Double Layered Deposit)

  • 박상언;김동수;김만;장도연;권식철
    • 연구논문집
    • /
    • 통권31호
    • /
    • pp.127-133
    • /
    • 2001
  • In chromium electrodeposition, crack is inevitably accompanied by chromium layer. Behavior of crack formation and crack density were different from the plating conditions such as current density, temperature, waveform of applied current and so on. And cracks have an influence on the corrosion resistance of chromium deposit, because corrosion occurs through the network of cracks between deposit and substrate. Therefore, many researches have been achieved in order to remove the cracks in chromium deposit. Formation of double layers, Cr/Cr and Ni/Cr were investigated to increase corrosion resistance of chromium deposit in this study. As pretreatment prior to outer chromium coating, acid pickling and current control method were examined. Cracks in cross-section of each sample were observed with SEM and CASS(Copper modified acetic acid salt spray) test was performed to evaluate corrosion resistance. It was found that corrosion resistance of Cr/Cr and Ni/Cr double layers were superior to Cr or Ni single layer from the results of CASS test.

  • PDF

8-Hydroxyquinoline을 이용한 크롬 3가 및 6가의 분리 및 분석 (Separation and analysis of Cr(III) and Cr(VI) using 8-hydroxyquinoline complexation of Cr(III))

  • 임헌성;이석근
    • 분석과학
    • /
    • 제20권3호
    • /
    • pp.246-250
    • /
    • 2007
  • The quantitative determination of chromium(VI) by separation from chromium(III) complex of 8-hydroxyquinoline using solvent extraction has been studied. The reaction conditions for chromium(III) complex of 8-hydroxyquinoline and the solvent extraction of complex were investigated in detail. The chromium(III) complex was extracted with organic solvent (n-hexane) and residual chromium(VI) was determined by ICP-AES in aqueous layer. This technique is quantitative in the pH range of 8-9 and the limitations such as interfering ions were discussed.

3가크롬 도금욕에서 펄스도금조건이 전류효율에 미치는 영향 (The Effect of Pulse Plating on the Current Efficiency in Trivalent Chromium Bath)

  • 황경진;안종관;이만승;오영주
    • 한국표면공학회지
    • /
    • 제36권2호
    • /
    • pp.161-167
    • /
    • 2003
  • In order to investigate the effects of pulse plating conditions on the electrodeposition of trivalent chromium, electroplating experiments from bath with low concentration of trivalent chromium were performed. The variation of current efficiency of chromium electroplating with the electroplating conditions was explained. The maximum current efficiency of pulse plating is 6.4 times as high as that of direct plating at the same mean current density The nodular size increased with pulse plating time and the pulse frequency.

THE ASSESSMENT OF GENOTOXICITY AND LIPID PEROXIDATION IN CHROMIUM EXPOSED WORKERS

  • Maeng, Seung-Hee;Yu, Il-Je;Lee, Byung-Moo;Chung, Ho-Keun;Chung, Hai-Won
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2002년도 Current Trends in Toxicological Sciences
    • /
    • pp.67-67
    • /
    • 2002
  • According to the epidemiological studies in chromium workers, hexavalent chromium is associated with the risk of lung cancer. Genotoxicity such as chromosome aberration, and cellular oxidative damages by reactive oxygen species produced by hexavalent chromium exposure may play an important role in the carcinogenesis process.(omitted)

  • PDF

크롬도금의 틈부식 거동에 관한 연구 (A Study on the Crevice Corrosion Behavior of Chromium Plating)

  • 곽남인;임우조
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.324-328
    • /
    • 2003
  • This study was made on the crevice corrosion behavior of chromium plating in fresh water. Under the various crevice, the electrochemical polarization test of chromium plating was carried out. Results are discussed In terms of corrosion potential, polarization resistance, corrosion current density and cathodic control of chromium plating.

도금폐수의 전해처리 (Electrolysis of Plating Waste Water)

  • 신석재;김동화
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.95-99
    • /
    • 1994
  • Recently, there has been considerable concern about waste water discharges of chromium. The Chromium(IV) is of particular concern because this form has been demonstrated to be public health hazard. Chromium(IV) could be removed by the method of electrolysis from plating waste water. It was found that almost all of chromium(IV) present could be treated by electrolysis at current, 3A and pH 8.

  • PDF

3가 크롬의 보조제로서의 역할 (The Role of Trivalent Chromium as a Supplement)

  • 박형숙;강영희
    • 한국식품영양과학회지
    • /
    • 제33권4호
    • /
    • pp.762-768
    • /
    • 2004
  • 인슐린 작용을 강화시키는 LMWCr의 발견과 크롬 결핍과 관련 있는 포도당 불내성(glucose intolerance)이 크롬 투여 시 반응을 보여준 임상적 증명 이후, 크롬은 확실한 필수 영양소로 인식되고 보조제로 사용되고 있다. 시험관 실험에서 고농도의 3가 크롬을 배양 세포에 노출 시, 일부 연구 결과에서 염색체이상 유발과 변이원성 효과가 발견되긴 하였으나 이는 비타민 A, D, 니코틴산, 셀레늄 등과 같은 많은 다른 영양소의 과잉 섭취 시 독성 효과를 나타내는 정도로 해석되며, 시험관 실험 결과들이 발암성의 증거로 해석되지는 않는다. 3가 크롬을 경구 보조제로 투여된 임상 치료에서 환자들은 독성효과를 보이지 않았으며, 혈장 내 크롬 수치가 비 투여된 사람들에 비하여 조금 높았다. 크롬을 TPN 형태로 투여받은 환자들에게서도 우려했던 신체ㆍ정신적 효과와의 상관 관계가 없었으며 신기능부전을 나타낸 경우는 신장 독성을 주는 약들을 함께 복용한 경우로서, 우려되는 부작용은 없는 것으로 인정된다. 임상학적, 실험적으로 사용된 3가 크롬의 용량은 ESADDI 규정된 범위 50∼200 $\mu$g/day에서 전혀 독성을 나타내지 않았으며, 일반적인 사용에 기준이 될 것이다. EPA는 모든 관련 자료들을 검토한 후에 크롬의 참고용량 (RfD) 수치를 70 mg/day로 결론지었으며, 다른 영양소들의 용량과 비교했을 때 대단히 넓은 수치이다. 3가 크롬은 당뇨병, 임신성 당뇨병, 인슐린 내성, 비정상적 지방대사를 개선시키기 위한 영양소로서 가능성을 가진다. 또한 크롬의 보충은 제II형 당뇨병과 다양한 심혈관계 질환을 예방하거나 치료하는데 가장 유용한 것으로 밝혀졌다. 앞으로는 크롬 보조제 사용 시, 일부 연구자들이 3가 크롬 1000 $\mu$g/day의 안전성을 입증한 것과 같이 용량을 늘려 임상실험을 시도한 후 안전과 효능을 증명하는 것이 필요하다.

EFFECTS OF CHROMIUM PICOLINATE ON GROWTH PERFORMANCE, CARCASS COMPOSITION AND SERUM TRAITS OF BROILERS FED DIETARY DIFFERENT LEVELS OF CRUDE PROTEIN

  • Kim, S.W.;Han, I.K.;Choi, Y.J.;Kim, Y.H.;Shin, I.S.;Chae, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제8권5호
    • /
    • pp.463-470
    • /
    • 1995
  • An experiment was conducted to evaluate the effects of chromium picolinate on growth performance, nutrient utilizability, carcass composition, serum traits and in vitro protein synthesis of 3 day old Arbor Acres broiler chickens when dietary crude protein levels were varying in diets. Six replicates of eight chicks each (average initial weitht = 59.4 g) were randomly assigned to three levels (low, medium, high) of dietary crude protein at two levels of chromium (0, 200 ppb Cr/kg diet) as chromium picolinate. Six chicks/treatment were randomly chosen for analyses of carcass composition, six additional chicks/treatment were randomly chosen for analyses of serum components, and a chick/treatment was chosen for in vitro culture of liver tissue. Chromium picolinate did not affect feed intake, protein and fat utilizability, regradless of dietary crude protein level. But feed/gain ratio were more improved in groups fed the low protein diets added with chromium picolinate compared with groups fed the medium and high protein diets with chromium picolinate. Carcass fat tended to decrease whereas carcass protein tended to increase when added with chromium picolinate. Broilers fed diets with chromium picolinate exhibited lower serum triglyceride and nonesterified fatty acid concentrations than those fed without chromium picolinate (p < 0.05). Both secreted and retained proteins in cultured acinar cell were higher in groups fed diets with chromium picolinate than those fed diets without chromium picolinate (p < 0.05). It could be suggested that chromium picolinate was effective in improving weight gain and nutrient utilizability when dietary crude protein was low (p < 0.05), and also effective in manipulating carcass fat when dietary crude protein level was high (p < 0.05).

THE MORPHOLOGY OF CHROMIUM AND LIF MEASUREMENT OF ATOMIC ARSENIC IN LAMINAR DIFFUSION FLAMES

  • Yoon, Young-Bin
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.61-68
    • /
    • 1997
  • The morphology and size distribution of chromium oxides and the concentration measurement of atomic arsenic have been studied in laminar diffusion flames. Nitrogen was added to vary flame temperatures in hydrogen flames. Ethene flames were used in order to investigate the potential for interaction between the soot aerosol that is formed in these flames and the chromium aerosol. Two sources of chromium compounds were introduced: chromium nitrate and chromium hexacarbonyl. A detailed investigation of the morphology was carried out by scanning electron microscopy (SEM). The amounts of Cr(VI) and total Cr were determined by a spectrophotometric method and by X-ray fluorescence spectrometry, respectively. Also, LIF was used for the measurement of atomic arsenic, which was excited at 197.2 nm and was detected at 249.6 nm. Results showed that the morphology of the particles varied with the flame temperature and with the chromium source. The particles were characterized by porous structures, cenospheres and agglomerated dense particles when chromium nitrate solution was added to the flames. At low to moderate temperatures, porous sintered cenospheric structures were formed, in some cases with a blow hole. At higher temperatures, an agglomerated cluster which was composed of loosely sintered submicron particles was observed. It was also found that the emission of Cr(VI) from the undiluted $H_2$ flame was more than 10 times larger than in the 50% $H_2$ / 50% $N_2$ flame on a mass basis. Single point LIF measurement of atomic arsenic indicated that arsenic exist only in the low temperature, fuel rich region.

  • PDF

탄소강의 유동가속부식에 미치는 크롬의 영향 (Effect of Cr on Flow Accelerated Corrosion of Carbon Steel)

  • 이은희;김경모;김홍표;김동진
    • Corrosion Science and Technology
    • /
    • 제14권1호
    • /
    • pp.25-32
    • /
    • 2015
  • The alloy content of structural materials of nuclear power plants has been recognized an important factor in predicting flow accelerated corrosion (FAC). In particular, many literature data reported that chromium content is one of the most important alloying element and even a small amount of chromium is effective to suppress FAC. This report reviewed and compared chromium models of Ducreux, Bouchacourt, and Kastner which were used in predicting FAC rates. The plant data indicate that Ducreux model may be conservative for the specimen containing 0.15 wt% chromium. The related articles were reviewed as follows. Combined effects of chromium content, pH, temperature, dissolved oxygen (DO), flow velocity, test time, and kinds of amine on the FAC rate were described. 0.1 wt% chromium in steel did not affect the FAC rate with changes in pH. The FAC rates pronounced with higher flow rate and increased with increasing test duration(600 d) for 0.013 wt% chromium. The FAC rates in mixed amine chemistry were higher than in ammonia chemistry, which may be lessened by the addition of chromium to the steel.