• Title/Summary/Keyword: Chroma Meter

Search Result 30, Processing Time 0.031 seconds

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

The effect and stability of Retinyl Palmitate(RP) in W/O, W/S, O/W, MLV(Multilamellar Vesicles) cream (W/O, W/S, O/W, MLV(Multilamellar Vesicles) TYPE에서 Retinyl Palmitate(RP)의 열적 안정성과 효능, 효과에 관한 연구)

  • 지홍근;서봉석
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.1
    • /
    • pp.40-59
    • /
    • 1996
  • Retinyl Palmitate, the skin normalzer, is useful to promote greater skin elasticity, to diminish lipid peroxidation and skin roughness following UV exposure, and promote a youthfull general skin appearance. We knew that the reduction of retinyl palmitate in W/O, W/S, O/W, MLV cream was caused by variable compound factors. Among the retinoids, we chose retinyl palmitate and studied the stability behavior of retinyl palmitate is liposomed. Furthermore, HPLC, CHROMA METERS, LASER SIGHT SCATTERING SYSTEM and FREEZE FRACTURE SCANNING ELECTROM MICROSCOPY was used to analyzing the stability and efficacy of UV and heat.

  • PDF

STUDY OF STABILITY AND EFFECT OF COLLOIDAL SILVER IN VARIOUS EMULSIONS (Colloidal Silver Emulsion에서 안정성과 효능, 효과에 관한연구)

  • 지홍근;윤경로
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.24 no.1
    • /
    • pp.48-73
    • /
    • 1998
  • Colloid refers to dispersed particles of solid or liquid having diameters of $10^{-5}$ to $10^{-7}$cm, among which colloidal silver is produced by electrolysis. Colloidal silver of various concentrations according to charge and time were formed, antimicrobial activity of colloidal silver was measured. And, the optimum conditions for emulsion were determined by changing the concentration of coloidal silver. Also, the stability of the emulsion was measured by zeta potential and chroma meter by applying colloidal silver to creams(W/S, O/W, MLV)

  • PDF

The effects on the color change of dental porcelain due to repeated firing (도재 소성 횟수가 색조변화에 미치는 영향)

  • Kim, Wook-Tae;Park, Chang-Keun
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.33-39
    • /
    • 2008
  • Recently natural characteristics and esthetics have been interested increasing in clinical dentistry. Thus the evaluation of the shade of dental porcelain has become an important part in dental research. Noritake Super Porcelain EX-3 Vita shade A2 (Noritake, Japan) Vintage HaLo Vita shade A2 (Shofu, Japan), Vita omega 900 Vitapan 3D-master shade 2M2 (Vita, Germany) were conducted for six times for repeated firing in a way to observe the change of color with respect to the number of firing. The repeated firing was implemented with the vacuum firing and air firing, and by using Shade Eye-EX Chroma meter (Shofu, U.S.A.), the changes in values of shade, value and chroma were compared. With the above results, the change of color was not noticed only in Vita when repeated firing was applied.

  • PDF

An Experimental Study on the Estimation of Sol-air Temperature and Absorptance in Building Exterior Materials by Using the Infrared Image (적외선 열화상을 이용한 건축외장재의 일사표면온도와 흡수율 추정에 관한 실험적 연구)

  • Park, Sa-Keun;Jang, Gil-Soo;Song, Min-Jeong;Shin, Hoon
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.33-39
    • /
    • 2006
  • This study aims to investigate the method to reduce the surface temperature caused by insolation. To achieve this goal, surface temperature of building is measured and the effects of exterior material's color and brilliance were checked with infrared imaging. And also, exterior material's absorptances due to outdoor surface heat transfer coefficients were measured. After surface temperature measurement of 37 specimen of 5 categories, the temperature is the highest on wood($53.62^{\circ}C$) and panel($52.05^{\circ}C$). Dryvit, stone, brick is the rating of order. For exterior material's absorptances, panel(0.883) and wood(0.868) were high and Dryvit, stone, brick follows wood and panel.

Effect of Roughness on the Color Stability of Artificial Teeth according to the Surface Treatment (표면 처리에 따른 거칠기가 인공치의 색안정성에 미치는 영향)

  • Kwon, Soon Suk;Lee, Hye-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.267-275
    • /
    • 2015
  • This study has been implemented to check the effect of roughness on the color stability according to the surface treatment of artificial teeth. 20 units of 3 groups with the different surface treatment of artificial teeth have been precipitated in the soy sauce, the red pepper paste, the coffee and the cola, measure equipment was used for Shade-eye(Chroma Meter, Shofu, U.S.A). The value of L*, a*, b* using its average value after measuring 3 times per 1 point by selecting 3 points randomly out of central parts of teeth on a cycle of each 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks after precipitation in terms of precipitated specimens. As a result of Multiple regression analysis, the value of ${\Delta}E*$ of artificial teeth according to the surface treatment showed the significant negative(-) effect in the Group 2(p<0.001) and the red pepper paste had the biggest effect on the color change of artificial teeth out of pollution source.

THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY (수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가)

  • Kim Lee-Kyoung;Cho In-Ho;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

STUDY ON COLOR DIFFERENCE BETWEEN NATURAL TEETH AND COMPOSITE RESINS (자연치와 복합레진의 색분포에 관한 연구)

  • 김희선;이인복;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.180-187
    • /
    • 2001
  • The structure of current guides is largely illogical and without any rational use of color ordering. The shade guides are generally made of plastic (rather than the actual composite material) and do not accurately depict the true shade. translucency. or opacity of the composite resin after polymerization. To solve this problem, information based on evaluations of natural teeth and material that use the same method and experimental conditions is necessary. The present investigation measured the color of natural maxillary anterior teeth in vivo and compared the results with those of composite resins. 269 Korean subjects were selected for this study. Intact central incisor. lateral incisor. and canine were selected. The clinical crowns were free of caries or restorations. The middle site of the coronal portion on the labial surface of the tooth was measured by Chroma Meter. The five light activated. resin-based materials (Amelogen, Denfil, Elitefil, Spectrum, Z100) were used in this study. Resin composite was condensed into plastic mold with a diameter of 8mm and a thickness of 4mm. pressed between glass plates to flatten the surfaces. and polymerized using a Visilux II visible light activation unit. The surfaces were polished sequentially on wet sandpaper. Color measurements of each specimen were accomplished by Chroma Meter. A computer program that compares each tooth color with each composite resin color was written and the minimum CIELAB color difference ($\Delta$E$^*$) between tooth and each material was calculated. Under the conditions of this study: 1. Teeth tend to become darker with advancing age. 2. Canines were darker. more yellow. and less green than incisors. 3. The teeth from the women were lighter. more green. and less yellow than the male teeth. 4. In general. composite resins were lighter. more green. and less yellow than teeth. Deficiencies were noted in Hues in YR range. 5. Mean color differences between the five composite resin products and teeth were detectable to the naked eye($\Delta$E$^*$>1.0). 6. In comparing the mean $\Delta$E$^*$ values of materials. Spectrum showed the least followed by Z100, Elitefil, Amelogen, Denfil in increasing order.

  • PDF

Physical Measurement of Color Changes in Foods (식품(食品)의 색도변화(色度變化) 측정법(測定法))

  • Cho, Sung-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 1984
  • The tools and techniques for measuring the spectral distribution of light emitted by, transmitted by, or reflected from food surfaces are described for determining the extent to which original natural color is preserved in processing and subsequent storage of foods. Color differences may be evaluated indirectly in terms of some physical characteristic of the sample or extracted fraction thereof that is largely responsible for the color characteristics. For evaluation more directly in terms of what the observer actually seen, color differences are measured by reflectance spectrophotometry and photoelectric colorimetry and expressed as differences in psychophysical indexes such as luminous reflectance and chromaticity. The standard system, against which other systems could be compared, is the one recommended by the International Committee on illumination and which is based on the 'standard observer', which is a simulated standard eye, consisting of three primary color filters Z, with X being essentially amber in color, Y, green and Z, blue. Any spectrophotometric curve of reflectance obtained from the surface of an object can be integrated in terms of X, Y and Z. Psychophysical notation may be converted by standard methods to the colorimetrically more descriptive terms of Munsell hue, value and chroma.

  • PDF

The Color Arrangement of Working Clothes for Visibility in Machine Industrial Work Site

  • Park, Hyewon
    • Journal of Fashion Business
    • /
    • v.17 no.3
    • /
    • pp.1-14
    • /
    • 2013
  • This study is about the evaluation of the color arrangements of working clothes that are harmonized with working environment and assist in the protection of workers in industrial sites. This study attempted color arrangement design with the intention of giving order to the colors of working environment and working clothes so as to help improve the safety of work and the management aspects including human resource management, efficiency improvement, and the practice of business ethics. The study method consisted of literature research, empirical research, and evaluation research. The literature research performed theoretical examination about colors, industrial safety, and visibility. Three actual outdoor work sites in the machine industry were chosen and pictures were taken at 20-30 m from workers. The background colors of the work environment of each work site and the colors of the working clothes that were actually worn were analyzed through color values measured with a color-difference meter(CR-400). As a result, it was found that between value and chroma which affect visibility, color arrangement based on differences in chroma could be a greater influence than color arrangement based on differences in value. The results of this study could assist the integration of color schemes among working environment colors, people and working clothes by suggesting color arrangements with improved visibility that are applicable to the working clothes of domestic machine manufacturers that are playing a pivotal role in domestic industries and by presenting appropriate guidelines.