• 제목/요약/키워드: Choi Buk

검색결과 225건 처리시간 0.03초

가공송전선로 애자 적용실태와 향후 전망 (Insulator application and prospect)

  • 김우겸;민병욱;김태영;위화복;최진성;이북창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.327_328
    • /
    • 2009
  • The insulator being used for transmission line is to mount the charged conductor on the tower or other supports. The insulators are classified according to its material: porcelain, glass and polymer. Polymer insulators are also called as composite insulator or non ceramic insulator (NCI). Insulators are a major element of a power transmission system. Since a faulty insulator can lead to a wide spreading blackout, it must have sufficient mechanical and electrical strength. It must be durable, have high electrical insulation and be able to withstand a leakage current. It must also be able to withstand the toughest weather conditions. In Korea, porcelain insulators have been used widely. However, to make compact equipment and keep up with global trends, we have enhanced domestic production of polymer insulator and are encouraging its applications. Accordingly, this thesis will look at types of insulators, use and trends, and prospects of insulators application in the field.

  • PDF

토목섬유를 활용한 철도 연약노반에서의 보강효과 (A Study on Reinforcement Effectiveness for Railway Soft Roadbed by Using Geotextiles)

  • 이진욱;최찬용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1546-1553
    • /
    • 2005
  • In this study, geotextiles was applied on the selected track-bed, which is relatively economical and efficient way to prevent the problem of mud-pumping and settlement. Field testing sections from Mock-haeng to Dong-ryang in the Chung-buk lines in Korea were selected to investigate the state of track and roadbed. And three places were chosen among 1,700 spots where mud-pumping was frequently occurred and maintenance required. At the curved section with radius of 500m between Mock-haeng and Dong-ryang, we divided this testing site into 5 section and 4 different types of geotextile were installed and left the last section with no reinforcement. Total length of the test site was 200m and individual length of each site was 40 m. In order to understand the state and the strength of prepared roadbed, stiffness and physical properties of the roadbed soil were evaluated and analyzed. Also, after the installation, mud-pumping, settlement of elastic or plastic sleeper, failure of track, wheel-loads, lateral force and earth pressures were investigated.

  • PDF

안전관리 평가 시스템 구축에 관한 연구 (A Study on Developing a Safety Management Evaluation Program)

  • 김윤화;임동연;임차순;고재욱;임동호;최수형
    • 한국가스학회지
    • /
    • 제2권3호
    • /
    • pp.96-100
    • /
    • 1998
  • Chemical plants with high-technological equipments and complex processes are continually increasing potential hazards that may result in huge industrial accidents. If an incident breaks out, it will have a hazardous effect on in-plant workers, neighboring inhabitants or the surrounding environment. Therefore, it is necessary to develop a safety management system that can pre-evaluate the safety and reduce the risk of a chemical plants. The safety management evaluation program developed in this study can implement an effective loss control management in chemical plants. It integrates important lists in safety management lists and legal measures to analyze elements systematically. It also includes incident case analysis and the required components in domestic laws.

  • PDF

대학 캠퍼스 방범용 CCTV 설치 지점의 적절성 평가 : 경북대학교를 사례로 (Evaluating locational validity of anti-crime CCTV installation point in university campus : A KNU case study)

  • 최진호;김준현;류택형
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2010년도 춘계학술대회
    • /
    • pp.175-179
    • /
    • 2010
  • 본 연구의 목적은 캠퍼스 내 설치된 CCTV의 현황과 설치환경을 파악하고, CCTV의 설치위치 주변 환경 기계적 성능 동을 고려하지 않을 때 발생하는 방범용 CCTV의 설치 및 운용에 문제점을 평가하는데 있다. CCTV의 설치 위치 평가를 위해 네트워크 분석을 활용 했으며, CCTV의 설치환경 분석을 위해서 기계적재원의 확인과 가로등 및 보안등의 조도측정이 이루어졌다. 그 결과 경북대학교 CCTV의 문제점은 크게 학생들의 보행패턴과 무관한 곳에 설치된 지역, 야간 촬영 시 요구되는 조도가 부족한 지역에 설치되어 있음이 확인 되었고, 44대의 CCTV 중 25대만이 범죄 예방이라는 소기의 목적을 위해 활용될 수 있음이 확인되었다.

  • PDF

154kV 송전선로 피뢰기 설치용 아킹혼 개발 (Development of Arc-horn to be mounted on 154kV Transmission Line Arrester)

  • 민병욱;김우겸;이북창;최한열;박재웅;금의연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.335-336
    • /
    • 2008
  • Overhead transmission lines are mainly crossing mountainous area. They are easily affected in weathers like typhoon, strong wind, lightning, heavy rain, or heavy snow. Sometimes these weathers cause transmission line faults. A lightning flashover is most often fault. Nowadays lightning density in KOREA is growing high and lightning flashovers occur more often. A lightning flashover on transmission line is mostly cleared by momentary operation of a circuit breaker, so power failure happens rarely. However, when both circuits trip simultaneously due to the lightning flashovers on double circuit transmission line, short time power failure and voltage drop happen. KEPCO has used transmission line arresters to avoid double circuit simultaneous trip out since 2003. And transmission line arresters cannot be installed with KEPCO's present metal fittings, so various fittings have been used for each transmission line arrester manufacturer. This paper introduces development and standardization of arc-horn and metal fittings for transmission line arrester which can be used for both existing lines and new lines in KEPCO.

  • PDF

기후변화의 생물학적 평가를 위한 한국온수생물지수(KTI)의 개발 및 적용 (Development and Application of Korean Thermality Index (KTI) for Biological Assessment on Climate Change)

  • 공동수;김진영;손세환;오민우;최아름;변명섭
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.114-126
    • /
    • 2013
  • The purpose of this study was to develop a Korean thermality index (KTI) based on the distribution patterns of benthic macroinvertebrates according to altitude and latitude. Analyzing seasonal data (4,853 sampling units) surveyed and collected during 2007 ~ 2011 at 846 sites in South Korea, we estimated thermal valency, thermal value and indicator weight value of 208 species. Among them, 40 species in 6 orders (Decapoda 1 species, Collembola 1 species, Ephemeroptera 5 species, Plecoptera 17 species, Diptera 3 species, Trichoptera 13 species) were selected as the candidate indicator species sensitive and vulnerable to warmth along with climate change. KTI and Benthic macroinvertebrate index (BMI) were tested at three clean streams (Hangye stream, Buk stream and Bangtae stream). KTI showed significant differences according to altitude and water temperature whereas the saprobity index BMI showed little differences. This result means that KTI can be applicable to assess the impact of water temperature independently of organic pollutants.

국산과 중국산 형개의 Pulegone함량분석 (Quantitative Analysis of Pulegone in Schizonepeta tenuifolia Briq.)

  • 김호경;이아영;이혜원;천진미;최지현;신자원;고병섭
    • Applied Biological Chemistry
    • /
    • 제49권2호
    • /
    • pp.125-128
    • /
    • 2006
  • Schizonepeta tenuifolia Briq. are used in folk medicine as common cold, sore throat, headache and skin infection in Korea, China and Japan. To compare the contents of domestic and Chinese Schizonepeta tenuifolia quantitative HPLC analysis was performed using a Luna $C_{18}$ column $(4.6{\times}250\;mm,\;5{\mu}m)$, with 1 ml/min of flow rate of 0.01% formic acid in water : acetonitrile = 50 : 50 under UV 254 nm of detector. Pulegone was detected at retention time of about 17.14 min.

Short-term Toxicity Assay Based on Daphnid Feeding on the Microalga Scenedesmus subspicatus

  • Lee Sang-Ill;Park Jong-Ho;Lee Won-Ho;Yeon Ik-Jun;Lee Byoung-Chan;Cho Kyu-Seok;Choi Hyun-Ill
    • Fisheries and Aquatic Sciences
    • /
    • 제9권1호
    • /
    • pp.38-43
    • /
    • 2006
  • We developed and evaluated a method of short-term acute toxicity testing based on the feeding behavior of Ceriodaphnia dubia. In prior toxicity tests, neonates of C. dubia were hatched and cultivated with the addition of yeast only for the preparation of the transparent daphnid's gut. Scenedesmus subspicatus was supplied as food after 1 to 6 h of exposure to toxicants. The effects of 1-h and 6-h exposure time on test sensitivity did not significantly differ. A comparison of the short-term l-h acute toxicity test developed in this study to the standard 48-h acute toxicity test using heavy metals, cyanide, and pentachlorophenol indicated that the 1-h test provided an acceptable sensitivity level in toxicity testing of C. dubia..

구상흑연주철의 내마모성에 미치는 Sb 및 Sn 의 영향에 관한 연구 (The Effects of Antimony and Tin Addition on the wear resistance properties of ductile cast iron)

  • 권영훈;김창규;김복석;김성한;천병욱;최창옥
    • 한국주조공학회지
    • /
    • 제11권6호
    • /
    • pp.463-474
    • /
    • 1991
  • The effect of $0.01{\sim}0.10%$ Sb and Sn on the wear resistance of ductile cast iron was investigated. The hardness was increased with Sb to 0.10%, but the elongation and the impact value were decreased. The tensile strength was increased with up to 0.05% Sb, however decreased with $0.05{\sim}0.10%$ Sb. The hardness and the tensile strength were increased and the elongation was decreased with up to 0.10% Sn. The nodularity of graphite was decreased with above 0.08% Sb however Sn had no effect on that. When the maximum compressive stress was low ($42kg.f/mm^2$), the weigth loss was decreased with increased hardness and when that was high ($54kg.f/mm^2$ and $65kg.f/mm^2$), the weight loss did not depend upon the hardness. The pearlite stabilization with Sb and Sn increased with the wear resistance of ductile cast iron.

  • PDF

운행선상의 연약노반 시험부설구간에서의 장기계측을 통한 거동 특성 (Characteristics of Behavior of the Soft Roadbed through Long-Term Instrumentation on the Field Test)

  • 이진욱;최찬용;이성혁;이창열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1058-1064
    • /
    • 2004
  • As one of reinforcing methods for soft roadbed, the problems that mud-pumping and settlement occurred by soft roadbed, were investigated, evaluated and analyzed through installing relatively economical and efficient geosynthetics on the selected track-bed for testing. Mock-heang to Dong-ryang on the filed resting sections in the Chung-buk lines were selected as investigating the state of track and prepared field after selecting three of 1,700 spots which often make mud-pumping and requiting maintenance for that. Long curved line radiuses(R) of Mock-heang to Dong-ryang are 500m that were installed with 4 types of geosynthetics layers and one ballast layer. Installed testing cross-section is 200m totally with 40 m between places. Strength or prepared roadbed was measured to investigate the state of roadbed and track with constructing(installing) field testing sections and physical properties of roadbed soils were evaluated and analyzed. Also, mud-pumping, settlement of elastic or plastic sleeper, failure or track, wheel-loads, transverse and earth pressures were measured after installing field testing sections.

  • PDF