• Title/Summary/Keyword: Chlorofluorocarbons

Search Result 21, Processing Time 0.027 seconds

Evaluation of Ground-Water Sampling Techniques for Analysis of Chlorofluorocarbons (지하수의 CFCs(Chlorofluorocarbons) 조사를 위한 시료 채취 방법의 평가)

  • 고동찬;이대하
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2003
  • Two types of ground-water sampling techniques for CFCs (chlorofluorocarbons) analysis, the cold-welded copper tube method and flame-sealed borosilicate glass ampule method, were compared and evaluated. CFCs concentrations by the copper tube method showed a poor reproducibility among triplicates whereas those by the glass ampule method showed a good agreement and relative standard deviations of triplicates were less than 5%. The poor reproducibility of the copper tube method appears to be attributed to the incomplete sealing in connection between faucets of wellhead and the sampling apparatus. The copper tube method also showed higher CFCs concentrations than the glass ampule method, which is more pronounced for CFC-11 than for CFC-12. The plastic tubings and rubber gasket of faucets in case of the copper tube method possibly contaminated the samples with CFC-11 and CFC-12. The potential of CFCs contamination for the glass ampule method was eliminated by using stainless steel and Nylon only and by connecting the sampling equipment directly to the main discharge pipe of wellhead. The validity of the glass ampule method were also verified by detecting very low level of CFCs for the ground-water sample which is old enough to have negligible CFCs.

Potential Application of Environmental Tracer in Hydrogeochemistry Using Sorption Properties (환경 추적자의 흡착 특성을 이용한 수리지화학적 활용 가능성 고찰)

  • Choung, Sungwook;Chang, Seeun;Kim, Minkyung;Kim, Sungpyo;Um, Wooyong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.59-68
    • /
    • 2012
  • This study provided sorption properties of chlorofluorocarbons (CFCs), and elucidated potential application of CFC sorption data in hydrogeochemistry. Prior sorption studies were reviewed for hydrophobic organic compounds similar to the CFCs, because there were only few CFC sorption studies. The CFCs are regarded as relatively conservative chemicals in groundwater environments based on their moderate hydrophobicity. However, thermally altered carbonaceous matter (TACM) can significantly increase sorption capacity and nonlinearity for hydrophobic organic compounds such as CFCs, compared to general soil organic matter. CFC sorption behavior are close to the sorption for reviewed organic chemicals. Therefore, the CFC sorption data can be used for determining hydrogeochemical properties and predicting transport of organic contaminants in TACM-containing aquifer environments.

Experimental Evaluation of an Analytical Method for Chlorofluorocarbons (CFSs) in Air and Water Using Gas Chromatography (가스 크로마토그래피를 이용한 대기와 물시료의 CFCs(chlorofluorocarbons) 분석법의 실험적 평가)

  • Koh, Dong-Chan;Choi, Beom-Kyu;Kim, Yong-Je
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.129-140
    • /
    • 2007
  • CFC(CFC-12, CFC-11 and CFC-113) analytical system for air and water was constructed using a customized purge and trap extraction device and a gas chromatograph with an electron capture detector. Sampling methods of air and water for CFCs were also established. The analytical system was experimentally optimized to result in reproducibilities of triplicates less than 2% for current air samples and less than 5% for groundwater samples with CFC-12 concentration of 160 to 180 pg/kg, and verified with respect to the CFC system in USGS, which showed analytical results were in agreement within 10%. CFCs in air were monitored at three sites over 19-month period in the central part of South Korea, and the result indicates no significant local sources of CFCs in those areas. For groundwater in Jeju Island, CFCs were measured over a year with a two-month interval. The time-series data showed seasonal fluctuations which could be interpreted by the effect of recharge pulse derived from large amount of rainfall during monsoon period with a few month delay, which indicates high permeability of basaltic rocks in Jeju Island.

An Integrated Emission Model of Greenhouse Gases to Assess Regional Climate Change

  • Moon, Yun-Seob;Oh, Sung-Nam;Hyun, Myung-Suk
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.421-422
    • /
    • 2003
  • Greenhouse gases (GHGs) such as carbon dioxide ($CO_2$), methane (CH$_4$), nitrous oxide ($N_2$O), chlorofluorocarbons (CFCs), sulphur hexafluoride (SF$_{6}$), together with water vapour ($H_2O$) and ozone play an important role in determining the earth's climate. The primary cause of the enhancement of GHGs is the global use of fossil fuels to generate heat, power, and electricity for a growing world population, as well as the changes in the land use, especially for agriculture. In addition, biomass buring and biofuel emissions play major roles in the GHG emissions in the Asian region because they produce large amounts of carbon monoxide (CO), nonmethane volatile organic compounds(NMVOC), black carbon(BC) and other gases. (omitted)d)

  • PDF

CFCs 조사를 위한 지하수 시료채취방법 비교 및 평가

  • 고동찬;이대하;성현정;강철희;고경석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.21-23
    • /
    • 2002
  • Two sampling methods for chlorofluorocarbons(CFCs) in groundwater were compared and assessed with groundwater samples in Jeju Island. CFCs concentrations from copper tube method were widely variable among triplicates and higher than those from flame-sealed glass ampule method. For the copper tube method, this is aggravated by rubber packings in the faucet of discharge line of wells, which was removed for the glass ampule method. The poor reproducibility and apparent contamination of results by copper tube method is due to the improper sealing of copper tubes and materials in water discharge line. This suggests that it is more difficult to achieve complete isolation from the atmosphere in the copper tube method and that materials that could release CFCs should be avoided along the sampling flow lines. It seems that the flame-sealed glass ampule method is more relevant for groundwater sampling for CFCs though it requires more complicated equipments and procedures.

  • PDF

Induction of cytochrome P450 2E1 by 1-bromopropane in male ICR mice (ICR 마우스 수컷에서 1-bromopropane에 의한 cytochrome P450 2E1의 유도)

  • Lee, Sang-Kyu;Jeong, Tae-Cheon
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.213-218
    • /
    • 2009
  • 1-bromopropane (1-BP) has been used in numerous purposes such as an intermediate in the synthesis of pharmaceuticals, a solvent for fats, waxes, or resins and a substitute for chlorofluorocarbons that destroy the ozone layer. However, the studies related to the modulation of activities of hepatic cytochrome P450s (CYPs) are not reported yet. This study was the first study to investigate the potential effect for the activities of hepatic CYPs by the treatment of 1-BP in vivo. When 1-BP was treated to male ICR mice by dose-dependently at the dose levels of 200, 500 and 1,000 mg/kg of body weight once, the activity of CYP2E1 was selectively increased for 24 h. The inductive potency for the activity of CYP2E1 by 1-BP was equal to induction by acetone a well-known selective CYP2E1 inducer. The present results indicated that 1-BP would affect the metabolism of 1-BP itself and/or other xenobiotics.

Decomposition of HFCs using Steam Plasma (스팀 플라즈마를 이용한 HFCs 분해특성)

  • Kim, Kwan-Tae;Kang, Hee Seok;Lee, Dae Hoon;Lee, Sung Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.27-37
    • /
    • 2013
  • CFCs (Chlorofluorocarbons) and HCFCs (Hydrochlorofluorocarbons) that are chemically stable were proven to be a greenhouse gases that can destroy ozone layer. On the other hand, HFCs (Hydrofluorocarbons) was developed as an alternative refrigerant for them, but HFCs still have a relatively higher radiative forcing, resulting in a large Global Warming Potential (GWP) of 1,300. Current regulations prohibit production and use of these chemicals. In addition, obligatory removal of existing material is in progress. Methods for the decomposition of these material can be listed as thermal cracking, catalytic decomposition and plasma process. This study reports the development of low cost and high efficiency plasma scrubber. Stability of steam plasma generation and effect of plasma parameters such as frequency of power supply and reactor geometry have been investigated in the course of the development. Method for effective removal of by-product also has been investigated. In this study, elongated rotating arc was proven to be efficient in decomposition of HFCs above 99% and to be able to generate stable steam plasma with steam contents of about 20%.

The Flow Characteristics of Pressure Control Valves for Natural Refrigerants (천연 냉매용 압력제어밸브의 유동특성 평가)

  • Kang, Hyo-Lim;Park, Hyung-Joon;Kim, Ga-Eun;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.3
    • /
    • pp.51-56
    • /
    • 2020
  • Research into natural refrigerants that use CO2, instead of chlorofluorocarbons and hydrofluorocarbons, has increased due to the environmental problems caused by ozone depletion. CO2 refrigerants are more environmentally friendly than conventional refrigerants because they have better latent heat of evaporation and heat transfer efficiency properties. However, they have very low critical temperatures and require high design pressures; therefore, pressure control valves, which reduce the pressure of the CO2 refrigerant to a safe level and apply it to the refrigerant air conditioning system, are necessary to secure stability against high pressure. In the present study, we evaluated the flow characteristics and valve performance of the pressure control valve using a CO2 refrigerant by measuring the pressure, velocity, and flow coefficient. In addition, we examined the applied forces caused by the internal pressure from the highly pressurized CO2 refrigerant and required thrust characteristics.

지하수 조사에서 환경추적자로서의 $SF_6$의 적용

  • ;Niel Plummer;Eurybiades Busenberg
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.73-76
    • /
    • 2003
  • SF$_{6}$ (Sulfur Hexafluoride) is a gaseous compound whose use is being greatly increased recently. The compound has a negligible background concentration from natural sources and is stable in most of groundwater environments. Therefore, SF$_{6}$ has potential for a dating tool for young groundwater. It has many advantages over chlorofluorocarbons (CFCs) for groundwater investigation that sampling procedure is much simpler than CFCs and its growth is continued up to at least near future in the atmosphere. However, solubility of SF$^{6}$ is so low that excess air causes large uncertainties in recharge date of groundwater. To compensate the limitation, $N_2$/Ar method can be employed to estimate excess air content. A groundwater study is currently carrying out in Jeju Island using SF$_{6}$ as an environmental tracer, Well waters and spring waters were sampled for SF$_{6}$ and $N_2$/Ar. To establish SF$_{6}$ input history in the study area, air sampling is being conducted in the area near the center of the island on a monthly and weekly basis. Based on the present data, the level of SF$_{6}$ concentration in the atmosphere of the Island is corresponding to the trend of the Northern Hemisphere.

  • PDF

Numerical Study on the HCFC-123 Leak in Turbo Chiller by using CFD (터보냉동기의 HCFC-123 누출에 대한 수치해석 연구)

  • Seo, Hoekyeong;Song, Sewook;Hwang, Yangin;Ha, Hyunchul
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.85-90
    • /
    • 2014
  • Turbo chiller is widely used for the air conditioner and uses hydrochlorofluorocarbon 123 (HCFC-123) as a refrigerant. HCFC-123 is one of the chemicals being considered as a replacement for the chlorofluorocarbons. High concentrations of HCFC-123 cause a deficiency of oxygen with the risk of unconsciousness or death, the vapour is heavier than air and may accumulate in low ceiling spaces causing deficiency of oxygen. In this study, the concentration distribution of oxygen indoor was investigated by using computational fluid dynamics(CFD) as four workers were killed in HCFC-123 gas leaks at machine room of hypermarket in 2011.