• Title/Summary/Keyword: Chlorine ion

검색결과 160건 처리시간 0.024초

플라즈마 화학증착한 알루미늄 산화박막의 $CCl_4$ 플라즈마에서의 반응성 이온식각 특성 (Reactive Ion Etching Characteristics of Aluminum Oxide Films Prepared by PECVD in $CCl_4$ Dry Etch Plasma)

  • 김재환;김형석;이원종
    • 한국세라믹학회지
    • /
    • 제31권5호
    • /
    • pp.485-490
    • /
    • 1994
  • The reactive ion etching characteristics of aluminum oxide films, prepared by PECVD, were investigated in the CCl4 plasma. The atomic chlorine concentration and the DC self bias were determined at various etching conditions, and their effects on the etch rate of aluminum oxide film were studied. The bombarding energy of incident particles was found to play the more important role in determining the etch rate of aluminum oxide rather than the atomic chlorine concentration. It is considered to be because the bombardment of ions or neutral atoms breaks the strong Al-O bonds of aluminum oxide to help activate the formation reaction of AlCl3 which is the volatile etch product.

  • PDF

이상적인 음료수 공급을 위한 수질관리에 관한 연구 (Study on the Water Management to get High Quality of Drinking Water)

  • 김형석;신현덕;박경석
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

초고층 건축물 매트 기초용 고성능 콘크리트 내구성 평가 (Durability Evaluation of High-Performance, Low-Heat Self-Compacting Concrete for Foundation of Tall Buildings)

  • 김영봉;박동천
    • 한국건축시공학회지
    • /
    • 제22권5호
    • /
    • pp.425-430
    • /
    • 2022
  • 초고층 건축물용 매트기초에 사용되는 콘크리트는 시공성 및 품질확보를 위하여 일체타설로 진행되는 경우가 많다. 하지만 일체타설의 경우 수화반응 과정에서 온도균열이 발행할 우려가 높으며 혼화재 치환을 통해 고성능 고내구성 콘크리트 최적배합을 도출할 필요가 있다. 본 연구에서는 저자의 기존연구에서 도출한 최적 고성능 저발열 콘크리트 배합으로 제작된 시험체를 대상으로 염해 및 탄산화, 내황산염에 대한 실험을 실시하고 염소이온 확산계수와 탄산화계수, 황산염에 대한 시멘트 매트릭스의 저항을 정량적으로 평가하였다. 혼화재의 혼입에 의한 잠재수경성 및 포졸란 반응에 의한 높은 저항성을 확인할 수 있었다.

콘크리트내로 침투하는 염소이온 반응형 부식센서의 응답특성에 미치는 센서 세선 수의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete)

  • 이현석;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.143-152
    • /
    • 2014
  • 본 연구에서는 콘크리트내로 침투하는 염소이온을 모니터링하기 위하여, 스크린프리트 기법으로 염소이온 반응형 부식센서를 개발하고, 센서의 세선 수가 부식반응도 및 민감도에 미치는 영향을 실험을 통하여 정량적으로 분석하였다. 개발된 부식센서를 이용하여 염소이온량에 따라 부식 반응도을 확인하였으며, 센서의 파괴정도에 따른 저항변화에서는 단선형 센서보다 다선형 센서에서 큰 저항 변화를 나타내었다. 또한, 부식센서는 NaCl 수용액의 농도가 높은 만큼 센서의 저항변화가 크고, 콘크리트 내에서 센서 종류에 따른 부식저항은 단선형보다 다선형에서 민감도가 높게 나타났으며, 센서의 매설깊이가 클수록 저항변화 사이클 (cycle)은 증가하였다. 이상의 결과로, 본 연구에서 개발된 부식센서는 염분에 대한 부식반응과 민감도, 저항의 변화를 감지할 수 있었으며, 특히 7세선이 우수한 결과를 나타내어, 염분의 침투정도를 모니터링 하는데 가장 적합하다고 판단된다.

반응성 이온 식각후 AlCu막의 부식현상 (The corrosion phenomena of AlCu films after reactive ion etching)

  • 김창일;권광호;김상기;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.252-255
    • /
    • 1996
  • Cl-based gas chemistry is generally used to etching for Al alloy metallization. After the etching of Al alloy with Cl-based gas plasma, residual chlorine on Al alloy reacts with $H_2O$ due to air exposure and results in Al corrosion. In this study, the corrosion Phenomena of Al were examined with XPS(X-ray photoelectron spectroscopy) and SEF(Scanning electron microscopy). It was confirmed that chlorine mainly existed at the grain boundary of Al alloy after plasma etching of Al alloy with Cl-based gas chemistry and Al corrosion was largely generated at the grain boundary of Al a1loy. And residual chlorine was passivated by sulfur and fluorine which were generated by SF$_{6}$ plasma. These effects of passivation reduced the Al corrosion due to air exposure.e.

  • PDF

경화된 하이드로탈사이트 혼입 포틀랜드 시멘트 페이스트의 염소이온 고정능력 평가 (Evaluation of Chloride Ion Binding Capacity of Hardened Portland Cement Paste Containing Hydrotalcite)

  • 한재도;이윤수;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.27-28
    • /
    • 2018
  • Deterioration of reinforced concrete structures due to salt corrosion is a phenomenon that can be easily seen, and the main reason for deterioration is chloride ion. Therefore, researches are actively conducted to control chlorine ion penetration worldwide. The purpose of this study is to evaluate the chloride ion fixation capacity of Portland cement paste containing Hydrotalcite. For this purpose, cement paste containing 0%, 2.5%, and 5% of Hydrotalcite was sealed and cured for 28 days, and the cured cement paste was crushed. Chloride ion solution was prepared at a concentration of 0.5M using NaCl, and the powdered cement paste was reacted for a specific time in aqueous chloride ion solution. After the reaction, the concentration of the chloride ion aqueous solution was measured using a silver nitrate potentiometric titrator, and the reacted cement paste was analyzed using XRD and FT-IR.

  • PDF

클링커 염소 함량이 조강형 시멘트의 응결 및 압축강도에 미치는 영향 (Effect of Chlorine Content in Clinker on Setting and Compressive Strength of Early Strength Cement)

  • 최재원;유병노;서동균;김경석;한민철
    • 한국건설순환자원학회논문집
    • /
    • 제11권3호
    • /
    • pp.218-225
    • /
    • 2023
  • 본 연구에서는 염소 성분의 시멘트 수화반응 촉진 효과를 이용하여 염소 함량을 증가시킨 클링커의 조강형 시멘트로서의 활용 가능성을 평가하였다. 실제 시멘트 제조설비를 이용해 염소 성분 200-1,000 ppm 수준의 클링커를 제조하고, 여기에 석고 및 혼합재를 첨가하여 46개의 시멘트 시료를 제조하여 이의 표준주도 및 응결, 압축강도를 측정해 통계 분석하였다. 시험 결과, 염소 함량 증가에 따라 응결이 단축되고, 1일 압축강도가 향상되었지만, 28일 압축강도는 하락하였다. 특히 염소 함량을 230에서 965 ppm으로 증가시킬 경우 1일 압축강도가 4.6 MPa 향상되어 3,400-3,970 cm2/g 범위에서 Blaine을 증가시키는 것보다 향상 효과가 뛰어난 것으로 분석되었다.

Adsorption Characteristics of U ranium (VI) Ion on Cryptand Synthetic Resin Adsorbent

  • Kim, Hae-Jin
    • 통합자연과학논문집
    • /
    • 제10권4호
    • /
    • pp.225-231
    • /
    • 2017
  • Cryptand resins were synthesized by mixing 1-aza-18-crown-6 macrocyclic ligand with styrene divinylbenzene copolymer having 1%, 2%, 5%, and 10% crosslink by a substitution reaction. These synthetic resins were confirmed by chlorine content, elementary analysis, SEM, surface area, and IR-spectrum. As the results of the effects of pH, crosslink of synthetic resin, and dielectric constant of a solvent on uranium ion adsorption for resin adsorbent, the uranium ion showed high adsorption at pH 3 or over. Adsorption selectivity for the resin in methanol solvent was the order of uranium ($UO_2{^{2+}}$) > calcium ($Ca^{2+}$) > neodymium ($Nd^{3+}$) ion, adsorbability of the uranium ion was the crosslink in order of 1%, 2%, 5%, and 10% and it was increased with the lower dielectric constant.

Adsorption of Uranium (VI) Ion on 1-Aza-12-Crown-4 Synthetic Resin with Styrene Hazardous Material

  • Kim, Joon-Tae
    • 통합자연과학논문집
    • /
    • 제6권2호
    • /
    • pp.104-110
    • /
    • 2013
  • 1-Aza-12-crown-4 macrocyclic ligand was combined with styrene (2th petroleum in 4th class hazardous materials) divinylbenzene copolymer having 1%, 2%, 3%, and 6% crosslinks by a substitution reaction, in order to synthesize resin. These synthetic resins were confirmed by chlorine content, elementary analysis and IR-spectrum. As the results of the effects of pH, equilibrium arrival time, crosslink of synthetic resin, and dielectric constant of a solvent on uranium ion adsorption for resin adsorbent, the uranium ion showed high adsorption at pH 3 or over and adsorption equilibrium of uranium ion was about 2 hours. In addition, adsorption selectivity for the resin in methanol solvent was the order of uranium ($UO_2{^{2+}}$) > iron ($Fe^{3+}$) > lutetium ($Lu^{3+}$) ions, adsorbability of the uranium ion was in the crosslinks order of 1%, 2%, 3%, and 6% was increased with the lower dielectric constant.

The research on static and dynamic mechanical properties of concrete under the environment of sulfate ion and chlorine ion

  • Nie, Liangxue;Xu, Jinyu;Bai, Erlei
    • Computers and Concrete
    • /
    • 제20권2호
    • /
    • pp.205-214
    • /
    • 2017
  • The Hydraulically driven test system and ${\Phi}100mm$ split Hopkinson pressure bar(SHPB) test device were employed to research the quasi-static and dynamic mechanical properties of concrete specimens which has been immersed for 60 days in sodium sulfate (group S1) and sodium chloride (group S2) solution, the evolution of their mass during corrosive period was explored at the same time, and the mechanism of performances lost was analyzed from the microscopic level by using scanning electron microscope. Results of the experimental indicated that: their law of mass both presents the trend of continuous rising during corrosive period, and it increases rapidly on the early days, the mass growth of group S1 and group S2 in first 7 days are 76.78% and 82.82% of their total increment respectively; during the corrosive period, the quasi-static compressive strength of specimens in two groups are significantly decreased, both of which present the trend of increase first and then decrease, the maximum growth rate of group S1 and group S2 are 7.52% and 12.71% respectively, but they are only 76.23% and 82.84% of specimens which under normal environment (group N) on day 60; after immersed for 60 days, there were different decrease to dynamic compressive strength and specific energy absorption, and so as their strain rate sensitivities. So the high salinity environment has a significant effect of weaken the quasi-static and dynamic mechanical performance of concrete.