• Title/Summary/Keyword: Chlorine ion

Search Result 160, Processing Time 0.028 seconds

Adsorption of uranium(VI), calcium(II), and samarium(III) ions on synthetic resin adsorbent with styrene hazardous materials (스타이렌 위험물을 포함한 합성수지 흡착제에 의한 U(VI), Ca(II), Sm(III) 이온들의 흡착)

  • Kim, Joon-Tae
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.92-100
    • /
    • 2009
  • Azacrown resins were synthesized by mixing 1-aza-12-crown-4 macrocyclic ligand into styrene (2th petroleum in 4th class hazardous materials) divinylbenzene (DVB) copolymer with crosslinkage of 1%, 2%, 5% and 10% by substitution reaction. The synthesis of these resins was confirmed by content of chlorine, element analysis, thermogravimetric analysis (TGA), surface area (BET), and IR-spectroscopy. The effects of pH, time, crosslinkage of resins and dielectric constant of solvent on adsorption of metal ions by resin adsorbent were investigated. Metal ions showed a great adsorption over pH 3 and adsorption equilibrium of metal ions was about two hours. In addition, adsorptive selectivity of metals on the resin in ethanol solvent was increased in the order of ${UO_2}^{2+}$ > $Ca^{2+}$ > $Sm^{3+}$ ion and adsorption of uranium ion was decreased with increase of crosslinkage such as 1%, 2%, 5% and 10% and was inversely proportional to the order of dielectric constant of solvents.

Substitutions of coloring ions and their effects on wagnerite pigments for cetamic glazes (도자기 유약용 wagnerite의 합성 및 발색원소의 영향)

  • 정용선;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.1
    • /
    • pp.160-168
    • /
    • 1998
  • In order to investigate the color variation and the solubility limit in wagnerites by metal ion substitution, wagnerite ($A_2XO_4Z$) was synthesized and then, substituted by coloring metal ions, especially $CO^{2+},Ni^{2+}$ and $Cu^{2+}$ ions. When calcium was replaced with Mg, Co, Ni and Cu divalent ions, solid solutions were formed with a limited solubility. Single phase wagnerites were synthesized by the substitution of Ca with Mg and Co, and their colors were white and purple, respectively. Substitutions with $Li^+$ were succeeded in the specific composition and the substitution of vanadium for $X^{5+}$ were attempted, resulting in the wagnerites of dark purple, dark gold and light yellow colors. The substitution of chlorine was, also, attmepted for the fluorine site.

  • PDF

The Adsorption Characteristics of Heavy Metals by Acrylic Fibers Treated with Hydroxylamine (II) - Properties of Cu(II) Adsorption and its Chelates - (하이드록실 아민으로 처리한 아크릴 섬유의 중금속 흡착특성 (II) -구리 (II)흡착과 그 키일레이트의 성질-)

  • Chin Young-gil;Choi Suk-chul
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.2 s.30
    • /
    • pp.128-136
    • /
    • 1989
  • In order to investigate a practical application of fibrous adsorbents to heavy metal ions, amidoxime fibers, as a particular class of solid chelate agents, were prepared by hydroxylamine treatment for acrylic fibers in a recipe of neutralization. Among the important problems from plant effluents are toxic concentrations of heavy metals such as copper. Accordingly, the properties of Cu (II) adsorption and its chelates were studied. The results obtained are as follows; The fibrous adsorbents have the property of increasing the swelling volumes by amidoximation. The adsorption of Cu (II) ion is characterized by an endothermic reaction, which is estimated as the plus values in the enthalpy change ($\delta$H=1.30 Kcal/mol. and 3.14 Kcal/mol.). The Cu (II) ions are adsorbed in the range of pH $3\~8$ and the maximum adsorptions are occurred about pH 8. Owing to the anions $(NO_3^-,\;Cl^-)$ of copper salts, amidoxime fibers form 1:1 and 2:1 (ligand: metal) chelating complexes with Cu (II). The nitrate anion chelates to amide I (NH) of amidoxime groups and the chlorine anion does to nitrosyl (NO). These effects relate to the crystallization of the complex and the thermal property.

  • PDF

Ammonium Ion Removal and Regeneration for Zeolite Filtration in Drinking Water Treatment (정수처리에서 제올라이트 여과를 이용한 암모니아성질소의 제거와 재생)

  • Kim, U Hyang;Lee, Seung Hui
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.661-665
    • /
    • 2004
  • As the concentration of ammonium nitrogen could be reached 2~3 mg/L in the winter in the river. It was clear that the excessive concentration of chlorinated organics could be produced with the increase of chlorine addition to remove ammonium nitrogen. In the innovative ammonium nitrogen removal process, zeolite adsorption is very efficient as substitute for rapid sand filtration without other adverse quality change in the water. This study is conducted to evaluate the feasibility of ammonium nitrogen removal and regeneration by zeolite adsorption in drinking water treatment. Also, the reuse possibility of zeolite is evaluated to change the removal efficiency of ammonium nitrogen through several times of regeneration. The ammonium nitrogen was not removed in sand filter, but it was almost removed in zeolite filter during 7 days. The sand and zeolite filters have a similar result of turbidity removal. Therefore, zeolite filtration was confirmed the removal of turbidity and ammonium nitrogen as a media. When compared KCl with NaCl as a chemical for zeolite regeneration, it is demonstrated that KCl was more efficient than NaCl in the ability of zeolite regeneration. The adsorption rate of ammonium nitrogen was almost not decreased in the results of several times of regeneration. It is indicated that both zeolite and regeneration solution were possible to reuse without variation of regeneration rate through this study.

A Study on Chemical Cleaning of Electrolytic Facilities with Sea Water (해수전해설비의 화학세정 최적화 방안에 관한 연구)

  • 이한철;이창우;현성호
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.114-119
    • /
    • 1999
  • When NaOCl was generated and put into sea-water cooling machine in order to overcome the biological hindrances against sea-water cooling machine, it was converted into metallic ion, particularly Ca and Mg, as a hydrate in sea-water and is to stick to electrolyte as a side reaction. This phenomena make the distance between the electrolytes narrow to decrease the flow rate, which induces the local vortex flow which erodes the pole plate. Moreover, this increases the resistance of the electrolyte as well as voltage to decrease the electrolytic efficiency, which has curtailed a chlorine yield and caused a pole plate cut. We are able to overcome these problems by chemical cleaning and intend to extend the life-time of electrolyte and to increase output of the sea-water electrolysis facilities by studying optimal policy regarding chemical cleaning of electrolytic cell. Cleaning time of electrolytic facilities is determined when both increase in electrolytic efficiency and decrease in pole-plate voltage are 10%. At this time as operating current of electrolytic facilities is high, operating time is diminished. Whereas, parameter of end point determination according to cleaning is Mg ionic concentration in solution. When we use Cleaner as a 7wt% HCl, cleaning time is about 80min proper. We are able to maintain pole plate performance by protecting against pole plate cut by means of electrolytic by-product, improve operating rate of facilities, and cut down on maintenance expenditure after acidic cleaning.

  • PDF

Etching characteristics of BST thin films using $BCl_3/Cl_2$/Ar plasma ($BCl_3/Cl_2$/Ar 플라즈마를 이용한 BST 박막의 식각 특성)

  • Kim, Gwan-Ha;Kim, Dong-Pyo;Kim, Chang-Il;Lee, Chul-In;Kim, Tae-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.322-325
    • /
    • 2003
  • BST thin films were etched with inductively coupled plasmas. A chemically assisted physical etch of BST was experimentally confirmed by ICP under various gas mixtures. After a 20 % addition of $BCl_3$ to the $Cl_2/Ar$ mixture, resulting in an increased the chemical effect. As a increases of RF power, substrate power, and substrate temperature, and decrease of working pressure, the ion energy flux and chlorine atoms density increased. The maximum etch rate of the BST thin films was 90.1 nm/min at the RF power, substrate power, working pressure, and substrate temperature were 700 W, 300 W, 1.6 Pa, and 20 $^{\circ}C$, respectively. It was proposed that sputter etching is dominant etching mechanism while the contribution of chemical reaction is relatively low due to low volatility of etching product.

  • PDF

Conservation Laboratory of Keimyung University Museum (계명대학교 박물관 보존과학실 소개)

  • Kim, Byeong-Ju
    • 보존과학연구
    • /
    • s.6
    • /
    • pp.247-258
    • /
    • 1985
  • Conservation laboratory was attached to Keimyung University Museum inMarch 1980 and ever since it has been devoted mainly to the processing andconservation of metal objects. A number of objects have been processed inthis laboratory during the period, including those already in the collection ofthe Museum, those which were discovered during the three major excavationsof Kaya tombs conducted by the Museum, and those processed on commissionfrom other museums in the country,The activities of this laboratory include: (1) conserving the objects againstfurther erosion; (2) raising the archaeological value of the objects by revealingthe structure of such parts of the objects as concealed under rust; and (3)recovering the original shape of damaged objects.The methods adopted by the laboratory include: (1) removing from theobjects the ionized chlorine which usually are the major cause of erosion; (2)strengthening the objects by soaking them in acrylic resins; and (3) applyingresins to the surface of the objects to protect them from further erosion.Chemicals much employed by the laboratory includes the acrylic resin(Ruschot; developed jointly by the Cultural Property Research Institute ofKorea and Samwha Paint Company), the sodium sesquicarbonate, the sodiumhydroxide, the lithium hydroxide, and the benzotriazole.Major apparatus in the laboratory includes the vacuum immersion tank, theairbrasive, the ultrasonic cleaner, the pH-ion meter, the water bath, the zoomstereo microscope, the drying oven, and the drill.

  • PDF

Desalinization Characteristics after Reclamation of Tidal Flat on the Western Coast of Korea (서해안 간척지 토양의 탈염특성)

  • 민병미;김준호
    • The Korean Journal of Ecology
    • /
    • v.20 no.4
    • /
    • pp.275-283
    • /
    • 1997
  • Vertical and temporal characteristics of desalinized reclaimed soil were analyzed from reclaimed coastal land on the western coast of Korea. Of the vertical changes during desalting, pH valuse were the lowest at the topsoil without regard to reclaimation time. The content of C1 were designated as the early period (the first 2-4 years) which decreased exponentially and the later period(the last 5-7 years) which was almost constant, from top to down. In temporal changes of the soil attributes, pH values increased for 5 years and decreased at 6 year after reclamation. Chlorine leaches more rapidly than Na does, K and Ca are constant but Mg increases as time elapsed after reclamation. Sometimes the content of Ca and K in the reclaimed soil are of higher concentration than that of the seawater after reclamation. During desallinization as exemplified by decreasing EC of the soil, Cl and Na are rapidly leached, but K, Ca and Mg are somewhat enhanced. The ration of Na/Cl in the soil equals 1 when the EC registers 5 mmho and then increases dramatically as the EC decreases. Rapid leaching of $Cl^{-}$ elicits an increasing pH valus. The electrostatic balance of the soil is achived by replacement of $Cl^{-}$ with $OH^{-}$ until stationary or until a decreasing pH value is reached again.

  • PDF

Corrosion Behaviour of Water Pipes (수도관의 부기거동에 관한 연구)

  • 김원만;박영식
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.1
    • /
    • pp.1-16
    • /
    • 1992
  • Corrosion of pipes Is one of the most serious problems in the maintenance of water worlds. Corrosion is promoted not only by physical factors such as temperature, but also by electrochemical factors including concentration of soluble metal ions, chlorine ion, pH, DO and microorganisms. Corrosion products also affect corrosion rate. In this research, study results are summarized as follows ; 1) Corrosion test was performed for 4 weeks at $70^{\circ}C$, pH 7.0 with specimens of 4 types of metal materials used as service pipes. Corrosion rate and S.E.M were analyzed. The results were showed that corrosion 1.ate of carbon steel pipe was 4.10~5.22 $mg/\textrm{cm}^2$ . week, galvanized steel pipe 0.98~1.34$mg/\textrm{cm}^2$. week, Copper pipe 0.02~0.04$mg/\textrm{cm}^2$. week, stainless steel pipe 0.05~ 0.10$mg/\textrm{cm}^2$ . week. 2) When corrosion rate was tested for tile types of pipes at pH 7 and both $25^{\circ}C$ and $75^{\circ}C$, avaerage corrosion rate for 6 weeks at $25^{\circ}C$ Ivas 2.26$mg/\textrm{cm}^2$ . week in carbon steel pipe, 1.99$mg/\textrm{cm}^2$. week in galvanized steel pipe, 0.26 $mg/\textrm{cm}^2$. week in stainless steel pipe. At $87^{\circ}C$, average corrosion rate for 4 weeks u.3s 4.56 $mg/\textrm{cm}^2$. week in carbon steel pipe,

  • PDF

Detection of chlorine in tap water using a metal gold electrode (금속 Au 전극을 이용한 먹는 물 속 염소 이온 검출)

  • Ly, Suw-Young;Choa, Sung-Hoon
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.219-224
    • /
    • 2011
  • Voltammetric analysis of Cl(I) ion was performed using a metal gold (Au) electrode (AE) and a carbon nanotube electrode (CNTE). After the examination, the AE was found to have more sensitively detected Cl(I) than CNTE. The optimum analytical conditions for the cyclic voltammetry (CV) and the square wave (SW) stripping voltammetry were performed using AE. The detection limit of $6.5\;{\mu}g/L$ Cl(I) was attained. The developed techniques were compared with the common Cl meter and applied to water systems.