• 제목/요약/키워드: Chloride threshold

검색결과 66건 처리시간 0.026초

수용액내에서의 방청제 부식성능 평가연구 (A Study on the anti-Corrosion Properties of Inhibitor in Aqueous Solution)

  • 류화성;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.221-223
    • /
    • 2011
  • In this study, in order to comprehend performance of corrosion inhibitor, the experiment study was conducted about corrosion characteristic of 3 steps(0.0, norm 1/2, norm) compared to organic corrosion inhibitor standard use of liquid and molar 3 steps(0.0, 0.3, 0.6%) of Chloride by added amount of inorganic corrosion inhibitor by the corrosion inhibitor types about 2.4kg/㎥, 4.8kg/㎥ based on Chloride ion content 1.2kg/㎥ for service life prediction of concrete structure by using Poteniostat.

  • PDF

해양콘크리트 구조물의 염해 예측 및 유지보수 시뮬레이션시스템 개발 (Development of Maintenance Simulation System and Prediction of Chloride Ion Permeation for Marine Concrete Structures)

  • 이창수;김명원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.64-75
    • /
    • 2013
  • 실내촉진실험과 동시에 현장폭로실험을 병행하였기 때문에 연차별 실험계획에 따라 최근 5년차의 현장실험체 분석을 수행하고 모델을 업그레이드하는 과정에서 모델 검증을 위해 준공된 지 30년 가량된 방조제의 배수갑문콘크리트의 염화물 침투프로파일을 분석하였다. Zhang의 연구결과에서 언급된 표면에 가까운 콘크리트내부 염화물 농도를 기본모델의 표면염화물농도 대신으로 적용하였다. 장기간 노출되는 실험체의 염화물 측정자료 분석에서 확산계수의 변화분석을 통하여 Maage의 제안식을 기본모델에 적용하였다. 이렇게 보완된 수정모델을 통하여 예측된 자료와 현장자료를 비교하고, 임계시점, 즉 보수시점을 도출함으로서 본 연구의 제안모델과 유지보수 시스템이 간만대 염화물 침투프로파일 추정과 적정보수 시점 및 비용 예측에 사용될 수 있음을 보였다.

Distribution of Calcium Hydroxide at the ITZ between Steel and Concrete

  • Ann Ki-Yong;Kim Hong-Sam;Kim Yang-Bae;Moon Han-Young
    • 콘크리트학회논문집
    • /
    • 제17권3호
    • /
    • pp.481-485
    • /
    • 2005
  • The present study examines the distribution of calcium hydroxide, unhydrated cement grain and porosity at the steel-concrete interface. The formation of calcium hydroxide has been confirmed by microscopic analysis using BSE images containing the ITZ between the steel and concrete. It was found that calcium hydroxide does not form a layer on the steel surface, different from the hypothesis that has been available in investigating the corrosion of steel in concrete, ranging from 5 to $10\%$ within the steel surface. Moreover, the high level of porosity at the ITZ was observed, accounting for $30\%$, which may reduce the buffering capacity of cement hydration products against a local fall in the pH. These findings may imply that the mole of ($Cl^-$) :($OH^-$) in pore solution as chloride threshold level lead to wrong judgement or to a wide range of values.

Correlation between chloride-induced corrosion initiation and time to cover cracking in RC Structures

  • Hosseini, Seyed Abbas;Shabakhty, Naser;Mahini, Seyed Saeed
    • Structural Engineering and Mechanics
    • /
    • 제56권2호
    • /
    • pp.257-273
    • /
    • 2015
  • Numerical value of correlation between effective parameters in the strength of a structure is as important as its stochastic properties in determining the safety of the structure. In this article investigation is made about the variation of coefficient of correlation between effective parameters in corrosion initiation time of reinforcement and the time of concrete cover cracking in reinforced concrete (RC) structures. Presence of many parameters and also error in measurement of these parameters results in uncertainty in determination of corrosion initiation and the time to crack initiation. In this paper, assuming diffusion process as chloride ingress mechanism in RC structures and considering random properties of effective parameters in this model, correlation between input parameters and predicted time to corrosion is calculated using the Monte Carlo (MC) random sampling. Results show the linear correlation between corrosion initiation time and effective input parameters increases with increasing uncertainty in the input parameters. Diffusion coefficient, concrete cover, surface chloride concentration and threshold chloride concentration have the highest correlation coefficient respectively. Also the uncertainty in the concrete cover has the greatest impact on the coefficient of correlation of corrosion initiation time and the time of crack initiation due to the corrosion phenomenon.

문턱값과 추세분석을 이용한 지하수 수질관리체계 구축을 위한 연구 (Suggestion of a Groundwater Quality Management Framework Using Threshold Values and Trend Analysis)

  • 안현실;진성욱;이수재;현윤정;윤희성;김락현
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권7호
    • /
    • pp.112-120
    • /
    • 2015
  • Statistical trend analysis using the data from the National Groundwater Quality Monitoring Network (NGQMN) of Korea was conducted to establish a new groundwater quality management framework. Sen’s test, a non-parametric statistical method for trend analysis, was used to determine the linear trend of the groundwater quality data. The analysis was conducted at different confidence levels (i.e., at 70, 80, 90, 95, and 99% confidence levels) for three of groundwater quality parameters, i.e., nitrate-nitrogen, chloride, and pH, which have sufficient time series of the NGQMN data between 2007 and 2013. The results showed that different trends can be determined for different depths even for the same monitoring site and the numbers of wells having significant trends vary with different confidence levels. The wells with increasing or decreasing trends were far less than the wells with no trend. Chloride had more wells with increasing trend than other parameters. On the other hand, nitrate-nitrogen had the most wells with increasing trend and concentration exceeding 75% of the threshold values (TVs). Based on the methodology used for this study, we suggest including groundwater TVs and trend analysis to evaluate groundwater quality and to establish an advanced groundwater quality management framework.

분극저항 측정기법을 이용한 혼합 시멘트 모르타르의 임계 염화물 농도에 대한 연구 (A Study on Chloride Threshold Level of Blended Cement Mortar Using Polarization Resistance Method)

  • 송하원;이창홍;이근주;안기용
    • 콘크리트학회논문집
    • /
    • 제21권3호
    • /
    • pp.245-253
    • /
    • 2009
  • 콘크리트 내 철근부식상에 있어 염화물이온의 중요성은 임계염화물농도 (CTL)로서 나타내어진다. CTL은 철근을 둘러싼 부동태피막의 파괴를 유지하게끔 하는데 필요한 염화물량으로 정의되며 염화물량이 CTL에 도달할 경우 철근의 부식은 시작된다. CTL의 중요성에도 불구하고 기존의 콘크리트 구조물의 내구수명 예측을 위한 염화물량은 1 $m^3$의 단위체적당 1.2 kg 혹은 시멘트 중량당 0.4%로서 제시되고 있으며 이는 염해부식환경하의 다양한 환경 인자에 따른 한계치 설정에 대한 불확실성을 고려하지 않은 값이라 할 수 있다. 본 논문에서는 부식개시의 지표로서 결합재의 특성에 따른 부식저항성 및 부식진전에 따른 비율에 대하여 실험연구를 수행하였다. 실험시편으로는 직경 10 mm의 원형 철근을 모르타르 내 몰드에 삽입하여 OPC와 40%OPC+60%GGBS, 70%OPC+30%PFA 및 90%OPC+10%의 SF을 치환한 시편에 대하여 W/C=0.4의 조건으로서 실험을 수행하였다. 각 시편에는 다시 10단계 (0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder)의 내재염분 농도조건을 부여하여 부식전류를 측정하였다. 시편은 28일 양생을 하였으며 수분손실 및 염분손실을 방지하고자 폴리에틸렌 필름을 이용한 도포양생을 수행하였다. 선형분극저항 측정법에 의한 실험결과로서 각 결합재 치환률에 따른 부식임계치가 결정되었다. 또한 OPC, 60%GGBS, 30%PFA 및 10%SF의 혼입치환률을 적용한 시멘트 모르타르의 CTL 값은 시멘트 중량당 1.6%, 0.45%, 0.8% 및 2.15%의 총염화물 농도로 나타나고 있음을 확인하였다.

콘크리트의 염소이온 확산특성에 미치는 물-시멘트비 및 양생조건의 영향 (Influence of Water-Cement Ratios and Curing Conditions on the Diffusion Characteristics of Chloride Ion in Concrete)

  • 배수호;이광명;김지상;정상화
    • 대한토목학회논문집
    • /
    • 제26권4A호
    • /
    • pp.753-759
    • /
    • 2006
  • 염해환경 하에 있는 콘크리트 구조물의 내구수명을 예측하기 위하여 콘크리트의 표면 염소이온 농도, 염소이온 확산계수 및 임계 염화물량 등이 주요 인자로 사용된다. 이들 중 염소이온 확산계수는 콘크리트 품질 및 주변 환경조건 등에 많은 영향을 받으며, 이에 따라 콘크리트 구조물의 내구수명이 크게 달라지기 때문에 내구수명을 예측하는 데 가장 중요한 인자로 평가되고 있다. 콘크리트 내의 염소이온 침투 확산에 영향을 미치는 정성적인 주요 인자로는 물-시멘트비, 재령, 양생조건, 주위 환경의 염소이온 농도 및 건습조건 등을 들 수 있는데, 본 연구에서는 염소이온 확산실험을 통해 물-시멘트비와 양생조건이 콘크리트의 염소이온 확산특성에 미치는 영향을 조사하였다. 전위차를 이용한 촉진시험법에 의하여 확산셀을 통과한 전위차를 측정한 후, Andrade의 모델에 의하여 전압강하량을 고려하여 3종류의 물-시멘트비를 갖는 콘크리트의 염소이온 확산계수를 구하였다. 또한, 양생조건별로 물-시멘트비 및 재령 효과를 고려한 회귀분석을 통하여 염소이온 확산계수 추정식을 제안하였다.

아질산칼슘 방청제를 사용한 시멘트 경화체 내의 염소이온 거동 특성 (Characteristics of Chloride Ion Behavior in an Cement Matrix Using Calcium Nitrite Inhibitor)

  • 신민철;안기용
    • 한국건설순환자원학회논문집
    • /
    • 제12권2호
    • /
    • pp.206-213
    • /
    • 2024
  • 본 연구는 염소이온이 침투한 시멘트 모르타르에서의 아질산칼슘(Ca(NO2)2) 방청제의 방청 효과에 대한 실험적 연구이다. 이를 위하여 아질산칼슘 방청제를 함유한 시멘트 모르타르에 대하여 내부식성과 염화물 이동에 대한 실험을 실시하였다. 그 결과 아질산칼슘 방청제의 사용량을 증가하면 할수록 철근부식에 대한 염화물 임계 농도값이 증가한 반면, 염소이온의 이동속도는 빨라지는 것을 확인하였다. 그러나 아질산칼슘 방청제를 사용한 시멘트 모르타르의 경우 염소이온의 이동속도가 빨라서 부식 발생시간을 단언하는 것은 어려움이 있었다. 그러나 철근부식에 영향을 미치지 않을 아질산칼슘의 사용량은 본 연구의 범위에서는 시멘트 중량 대비 2.0~3.0% 수준의 결과를 나타내었다.

수산화칼슘을 혼입한 폴리머 방청 코팅의 부식 임계치 향상에 대한 연구 (A Study on Chloride Threshold Level of Polymer Inhibitive Coating Containing Calcium Hydroxide)

  • 송하원;이창홍;이근주;안기용
    • 콘크리트학회논문집
    • /
    • 제20권6호
    • /
    • pp.713-719
    • /
    • 2008
  • 철근콘크리트내의 염분침투저항성을 향상시키기 위한 방안으로 다양한 철근 방청 코팅기법이 개발되어져왔다. 이와 관련된 가장 일반적인 방법으로서는 방청철근의 사용, 시멘트 슬러리 코팅 및 폴리머계 복합수지를 사용한 철근 코팅 및 에폭시 코팅등을 들 수 있다. 여기서 폴리머계 시멘트 코팅이 철근의 부동태 피막 및 장벽보호를 동시에 꾀함과는 달리 시멘트 슬러리 코팅의 경우는 철근의 부동태 보호에, 에폭시 코팅의 경우는 철근의 장벽보호에 주 목적을 두고 있다. 더욱이 에폭시코팅의 경우는 시공상의 오차로 인해 철근의 비부착 문제를 일으키게 되며 이는 국부부식의 위험을 증대시키게 된다. 본 연구에서는 철근-콘크리트 계면에서, 최대 20%의 수산화칼슘의 증가를 통한 방청기법이 적용되어졌다. 수산화칼슘의 경우 높은 pH저하저항성을 가지고 있어 염해부식환경에 대해 알칼리성 환경이 유지하도록 하는 역할을 한다. 본 논문은 철근/콘크리트 계면에서의 pH 저하 저항성의 향상 방안으로서, 수산화칼슘의 첨가에 따른 철근 방청코팅의 향상 효과를 시험하였다. 또한 수산화칼슘을 혼입한 폴리머 코팅의 염화물임계치 (CTL)에 관해서도 비교분석을 하였다.

Shear-induced microstructure and rheology of cetylpyridinium chloride/sodium salicylate micellar solutions

  • Park, Dae-Geun;Kim, Won-Jong;Yang, Seung-Man
    • Korea-Australia Rheology Journal
    • /
    • 제12권3_4호
    • /
    • pp.143-149
    • /
    • 2000
  • In this article, we considered shear-induced microstructure and rheological behavior of micellar solutions of cationic surfactant, cetylpyridinium chloride (CPC) in the presence of a structure-forming additive, sodium salicylate (NaSal). Shear viscosity, shear moduli and flow birefringence were measured as functions of the surfactant and additive concentrations. In the presence of NaSal, the micellar solution exhibited the non-linear rheological behavior due to the formation of supramolecular structures when the molar ratio of NaSal to CPC exceeded a certain threshold value. Flow birefringence probed the change in micelle alignment under shear flow. At low shear rates, the flow birefringence increased as the shear rate increased. On the other hand, fluctuation of flow birefringence appeared from the shear rate near the onset of shear thickening, which was caused by shear-induced coagulation or aggregation. These results were confirmed by the SEM images of in situ gelified micelle structure through sol-gel route.

  • PDF