• Title/Summary/Keyword: Chest tube

Search Result 498, Processing Time 0.03 seconds

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Clinical Analysis of Spontaneous Pneumothorax (자연기흉의 임상적 고찰)

  • Son, Ji-Woong;Park, Jae-Yong;Kim, Kwan-Young;Chae, Sang-Chul;Kang, Tae-Kyong;Park, Ki-Su;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.374-382
    • /
    • 1999
  • Background: The aim of this study was to investigate etiologic factor, treatment, prognosis of spontaneous pneumothorax (SP). Material and Methods: The medical records of 225 cases of SP experienced at Kyungpook University Hospital from Jan. 1996 to Dec. 1997 were retrospectively analyzed. Results: The patients were 128 primary SP and 97 secondary SP. The mean age was $30{\pm}15.5$ years in primary SP and $51{\pm}7.4$ years in secondary SP. The ratio of male to female was 8:1 in primary SP and 5.5:1 in secondary SP. Smoker was more common in seconday SP (71.1 %) than primary SP (34.4%). About 70% of patients with primary and secondary SP was underweighted. The previous history of SP was present in 28.9% and 25.8% of primary and secondary SP, respectively. The main underlying lung diseases in secondary SP were inactive tuberculosis (68%), active tuberculosis (12.4%) and COPD (11.3%). Tube thoracostomy was performed in 96.8% and 97.9% of primary and secondary SP, respectively. The duration of chest tube insertion was longer in seconday SP ($18.2{\pm}19.59$ days) than primary SP ($7.5{\pm}6.57$ days). The open thoracotomy were performed in 22.7% and 10.3% of primary and secondary SP, respectively. The most com- mon indication of open thoracotomy was recurrence in primary SP and persistent air leak in secondary SP. During following-up of $17{\pm}7.8$ months, the recurrence rate in patients with conservative treatment was 16.5% and 11.8% of primary and secondary SP, respectively. The recurrence was most common within 1 month after discharge. Conclusion: Greater attention and research about SP are necessary for more efficient patient care.

  • PDF

Facters Affecting Recurrence after Video-assisted Thoracic Surgery for the Treatment of Spontaneous Pneumothotax (자연기흉에 대한 비디오흉강경수술후 재발에 영향을 미치는 요인들)

  • 이송암;김광택;이일현;백만종;최영호;이인성;김형묵;김학제
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.448-455
    • /
    • 1999
  • Background: Recent developments in techniques of video-assisted thoracic surgery(VATS) and endoscopic equipment has expanded the application of video-assisted surgical procedures in the field of thoracic surgery. Especially, it will probably become the treatment of choice of spontaneous pneumothorax(SP). There is, however, a high recurrence rate, high cost, and paucity of long-term results. We report the results of postoperative follow-up and analyze perioperative parameters affected to recurrence, retrospectively. Material and Method: From march 1992 to march 1997, 276 patients with spontaneous pneumothorax underwent 292 VATS procedures. Conversion to open thoracotomy was necessitated in eight patients, and this patients excluded from the study. Result: The sex distribution was 249 males and 31 females. The mean age was 28.1 12.2 years(range, 15 to 69 years). Primary SP was 237cases(83.5%) and secondary SP was 47cases(16.5%). The major underlying lung diseases associated with secondary SP were tuberculosis 27cases(57.4%) and emphysema 8cases (38.3%). Operative indications included Ipsilateral recurrence 123(43.9%), persistent air-leak 53(18.9%), x-ray visible bleb 40(14.3%), tension 30(10.7%), contralateral recurrence 21(7.5%), uncomplicated first episode 8(2.9%), bilateral 3(1.1%), complicated episode 2(0.7%). Blebs were visualized in 247cases(87%) and 244cases(85.9%) performed stapled blebectomy. Early postoperative complications occurred in 33 cases(11.6%): 16 prolonged air-leak more than 5 days(four of them were required a second operation and found missed blebs); 5 bleeding; 5 empyema; 2 atelectasis; 1 wound infection. No deaths occured. The mean operative time was 52.8 23.1 minutes(range, 20 to 165 minutes). The mean d ration of chest tube drainage was 5.0 4.5 days(range, 2 to 37 days). The mean duration ofhospital stay was 8.2 5.5 days (range, 3 to 43days). At a mean follow-up 22.3 18.4 months(range, 1 to 65 months), 12 patients(4.2%) were lost to follow-up. There were 24 recurrences and seven patients underwent second operation and 6 patients(85.7%) were found the missed blebs. 12 perioperative parameters(age, sex, site, underlying disease, extent of collapse, operative indication, size of bleb, number of bleb, location of bleb, bleb management, pleural procedure, prolonged postoperative air-leak) were analyzed statistically to identify significant predictors of recurrence. The significant predictors of recurrence was the underlying disease[17.0%(8/47): 6.8%(16/237), p=0.038], prolonged postoperative air-leakage[37.5%(6/16): 6.7%(18/268), p=0.001], and pleural procedure [11.4%(19/167): 4.3%(5/117), p=0.034]. Blebectomy has less recurrence rate then non-blebectomy [8.2%(20/244) : 10.0%(4/40), p>0. 5]. However, this difference was not statistically significant(p=0.758). Conclusion: We conclude that it is important that we shoud careful finding of bleb during VATS due to reducing of recurrnece, and cases of no bleb identified and secondary spontaneous pneumothorax were indicated of pleurodectomy. VATS is a valid alternative to open procedure for the treatment of spontaneous pneumothorax with less pain, shorter hospital stay, more rapid return to work, high patient acceptance, less scar and exellent cosmetics. But, there is high recurrence rate and high cost, and than it is necessary to evaluate of long-term results for recurrence and to observate carefully during VATS.

  • PDF

Modified Thoracoscopic Bullectomy (흉강경하 기낭절제술의 변형 술식)

  • Park, Chan-Beom;Cho, Min-Seob;Sa, Young-Jo;Lee, Jong-Ho;Jin, Ung;Kwon, Jong-Bum;Cho, Deog-Gon;Park, Kuhn;Cho, Kyu-Do;Kim, Chi-Kyeong
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.937-942
    • /
    • 2003
  • Morbidity, the use of analgesics, the amount of postoperative drainage and the postoperative hospital stay were reduced in VATS for pneumothorax. However, some authors preferred minithoracotomy to VATS because the rate of recurrence after VATS were between 5% and 10%. Therefore, we present a modified thoracoscopic bullectomy (MTB) which we believe has the advantages of conventional VATS and minithoracotomy. Material and Method: Sixty-six patients who received the operation from January 2002 to December 2002 were divided into 3 groups. Twenty-six patients were treated by axillary minithoracotomy and thirteen by conventional VATS and 18 by modified thoracoscopic bullectomy, The mean age was 21.9 years (range, 16∼35 years) for minithoracotomy group, 20.6 years (range, 17∼28 years) for conventional VATS group and 22.6 years (range, 16∼39 years) for MTB group. The mean follow-ups were 11.4 months for minithoracotomy group, 9.5 months for conventional VATS group and 4.7 months for MTB group. Result: The mean duration of operation was 55.79$\pm$23.35 minutes in MTB and 44.23$\pm$19.24 minutes in conventional VATS (p=0.333). The number of staplers being used was 1.63 $\pm$0.76 in MTB, 1.41$\pm$0.64 in minithoracotomy (p=0.663), and 2.92$\pm$1.19 in conventional VATS (p<0.001). The duration of indwelling chest tube was 1.63$\pm$0.76 day in MTB, 4.07$\pm$ 1.41 day in minithoracotomy (p<0.001) and 4.46$\pm$2.33day in conventional VATS (p<0.001). Hospital length of stay was 3.26$\pm$0.81 day in MTB, 6.04$\pm$2.21 day in minithoracotomy (p<0.001) and 6.69$\pm$3.33 day in conventional VATS (p<0.001). The number of postoperative complication and recurrence were 2 in minithoracotomy (7.4%), 5 in conventional VATS (38.5%) and 1 in MTB (5.6%). Conclusion: Modified thoracoscopic bullectomy is an effective procedure in the treatment of spontaneous pneumothorax.

Operative Treatment of Congenitally Corrected Transposition of the Great Arteries(CCTGA) (교정형 대혈관 전위증의 수술적 치료)

  • 이정렬;조광리;김용진;노준량;서결필
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.621-627
    • /
    • 1999
  • Background: Sixty five cases with congenitally corrected transposition of the great arteries (CCTGA) indicated for biventricular repair were operated on between 1984 and september 1998. Comparison between the results of the conventional(classic) connection(LV-PA) and the anatomic repair was done. Material and Method: Retrospective review was carried out based on the medical records of the patients. Operative procedures, complications and the long-term results accoding to the combining anomalies were analysed. Result: Mean age was 5.5$\pm$4.8 years(range, 2 months to 18years). Thirty nine were male and 26 were female. Situs solitus {S,L,L} was in 53 and situs inversus{I,D,D} in 12. There was no left ventricular outflow tract obstruction(LVOTO) in 13(20%) cases. The LVOTO was resulted from pulmonary stenosis(PS) in 26(40%)patients and from pulmonary atresia(PA) in 26(40%) patients. Twenty-five(38.5%) patients had tricuspid valve regurgitation(TR) greater than the mild degree that was present preoperatively. Twenty two patients previously underwent 24 systemic- pulmonary shunts previously. In the 13 patients without LVOTO, 7 simple closure of VSD or ASD, 3 tricuspid valve replacements(TVR), and 3 anatomic corrections(3 double switch operations: 1 Senning+ Rastelli, 1 Senning+REV-type, and 1 Senning+Arterial switch opera tion) were performed. As to the 26 patients with CCTGA+VSD or ASD+LVOTO(PS), 24 classic repairs and 2 double switch operations(1 Senning+Rastelli, 1 Mustard+REV-type) were done. In the 26 cases with CCTGA+VSD+LVOTO(PA), 19 classic repairs(18 Rastelli, 1 REV-type), and 7 double switch operations(7 Senning+Rastelli) were done. The degree of tricuspid regurgitation increased during the follow-up periods from 1.3$\pm$1.4 to 2.2$\pm$1.0 in the classic repair group(p<0.05), but not in the double switch group. Two patients had complete AV block preoperatively, and additional 7(10.8%) had newly developed complete AV block after the operation. Other complications were recurrent LVOTO(10), thromboembolism(4), persistent chest tube drainage over 2 weeks(4), chylothorax(3), bleeding(3), acute renal failure(2), and mediastinitis(2). Mean follow-up was 54$\pm$49 months(0-177 months). Thirteen patients died after the operation(operative mortality rate: 20.0%(13/65)), and there were 3 additional deaths during the follow up period(overall mortality: 24.6%(16/65)). The operative mortality in patients underwent anatomic repair was 33.3%(4/12). The actuarial survival rates at 1, 5, and 10 years were 75.0$\pm$5.6%, 75.0$\pm$5.6%, and 69.2$\pm$7.6%. Common causes of death were low cardiac output syndrome(8) and heart failure from TR(5). Conclusion: Although our study could not demonstrate the superiority of each classic or anatomic repair, we found that the anatomic repair has a merit of preventing the deterioration of tricuspid valve regurgitations. Meticulous selection of the patients and longer follow-up terms are mandatory to establish the selective advantages of both strategies.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

Dorsal Mini-thoracotomy for PDA Closure in Premature Neonates (후방 소개흉술을 통한 미숙아 동맥관 개존증의 수술요법)

  • Lee, Hyang-Lim;Choi, Chang-Hyu;Son, Dong-Woo;Shim, So-Yeon;Park, Kook-Yang;Park, Chul-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.434-440
    • /
    • 2009
  • Background: Surgical closure of a patent ductus arteriosus (PDA) can be considered when conservative medical treatment is ineffective or contraindicated. Low weight and earlier gestational age neonates who are treated with conservative medical therapy generally showed a higher failure rate. The morbidity of surgical PDA closure in such extremely low birth weight (ELBW) neonates is also high. Here we present the early results of a new technique for approaching the PDA through a dorsal minithoracotomy. Material and Method: From March 2006 to November 2008, 24 premature neonates underwent surgical PDA closure. The procedures were performed in the newborn intensive care unit via a 2 cm long dorsal minithoracotomy with the baby in the prone position with the left hemithorax elevated 30$^{\circ}$. Bimanual cotton swab blunt dissection completed the extrapleural accesstothe PDA and then two clips were applied. Tube thoracostomy was avoided if there was no meaningful pleural laceration. Result: The infants mean gestational age was 26.5$\pm$2.1 weeks (range: 23 to 30 weeks) and the average age at operation was 11$\pm$11 days. The mean body weight at operation was 933$\pm$271 grams (range: 570 to 1,700 grams). Eight patients expired, but there was no procedure-related death. Postoperative echocardiography revealed two cases of residual shunt but none of these shunts were detected on the follow up echocardiogram that was performed on the post operative 5 and 59 days. Conclusion: We concluded that the technique described here is an effective procedure in view of the satisfactory operative exposure and the low rate of complications.

Value of Pulmonary Function Test as a Predicting Factor of Pneumothorax in CT-guided Needle Aspiration of the Lung (전산화단층촬영 유도하 경피적 폐침생검시 기흉발생 예측인자로써의 폐기능검사의 가치)

  • Kim, Yeon-Jae;Kim, Chang-Ho;Lee, Yeung-Suk;Park, Jae-Yong;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.259-266
    • /
    • 1993
  • Background: To evaluate the risk factor of pneumothorax (PNX) which is the most common complication of CT-guided needle aspiration of the lung, we have examined the frequency of PNX according to the presence of obstructive ventilatory impairment determined by pulmonary function tests. Methods: A comparative study of analysis of forecd expiratory volume and folw-volume curves, and determinations of diffusing capacity taken before procedure were made between each 16 cases with PNX and controls with no PNX. Each of the control group was matched for sex, age, height, and size and depth of lesion with the former. Results: 1) In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups, VC and FVC were not significantly different, whereas $FEV_1$, $FEV_1$/FVC%, and FEF25-75% showed a significant decrease in the PNX gorup. Also, in the PNX group, all the observed values of parameters analyzed from flow-volune curve were siginificantly reduced in the PNX group compared with those in the control group. 2) The diffusing capacity tended to decrease along with varying individual differences in the PNX group. 3) Patients who had obstructive ventilatory impairment according to the results of pulmonary function tests experienced a twofold increase in the frequency of PNX and a sixfold increase in the frequency of chest tube drainage for treatment of PNX compared with those whose results were normal. Conclusion: These findings suggest that the exact evaluation of obstructive lung disease determined by pulmonary function test be considered assessing a pastient's risk for PNX in the patients who will take the CT-guided needle aspiration of the lung.

  • PDF

Bilateral Sequential Lung Transplantation in Dogs (황견에서 동종 순차적 양측 폐이식 수술에 관한 연구)

  • 이두연;김해균;문동석;윤용한;홍윤주;이성수
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.108-112
    • /
    • 1998
  • Experimental trials of unilateral lung transplantation in dogs have been attempted and satisfactory results were obtained without any noticeable difficulty in surgical techniques. Fourteen dogs with the body weight of around 25 kg were anesthesized by 20~30 mg/kg of intravenous Entobar,; one was sacrificed to make available blood for use during transplantation for the recipient dog. A mid-sternotomy incision was performed and 20 mg/kg of Prostaglandin E1 was infused through the pulmonary artery and Euro-Collin's(E-C) preservation solution, cooled down to 4$^{\circ}C$, was perfused at the rate of 70cc/kg by a pressure of 30 cmH2O. The heart-lung block was then resected out and promptly immersed in the prepared preservation solution at 4$^{\circ}C$. One lung preserved in the EC solution at 4$^{\circ}C$ was anastomosed to the recipient dog in the order of the pulmonary vein, bronchus then pulmomary artery and the thoracotomy incision was closed after the bleeding control and tube thoracostomy. Then the pneumonectomy in the opposite side was perfomed in the same manner and the tailored lung was transplanted in the order of the pulmonary vein, bronchus, then pulmonary artery. We conclude that in the bilateral sequential lung transplantation, the right lung transplantation should precede to better expose the operative field and to prevent reperfusion injury; also, the cardiopulmonary bypass should be consider for certain appropriate cases.

  • PDF