• Title/Summary/Keyword: Chemical substance

Search Result 643, Processing Time 0.023 seconds

The Measurement and Prediction of Combustible Properties of Dimethylacetamide (DMAc) (디메틸아세트아미드(DMAc)의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.553-556
    • /
    • 2015
  • The usage of the correct combustion characteristic of the treated substance for the safety of the process is critical. For the safe handling of dimethylacetamide (DMAc) being used in various ways in the chemical industry, the flash point and the autoignition temperature (AIT) of DMAc was experimented. And, the lower explosion limit of DMAc was calculated by using the lower flash point obtained in the experiment. The flash points of DMAc by using the Setaflash and Pensky-Martens closed-cup testers measured $61^{\circ}C$ and $65^{\circ}C$, respectively. The flash points of DMAc by using the Tag and Cleveland automatic open cup testers are measured $68^{\circ}C$ and $71^{\circ}C$. The AIT of DMAc by ASTM 659E tester was measured as $347^{\circ}C$. The lower explosion limit by the measured flash point $61^{\circ}C$ was calculated as 1.52 vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

Construction of Antibacterial Electrospun Nanofiber from Poly(styrene-co-sulfadiazine) via Electrospinning (폴리(스티렌-설파디아진) 공중합체를 이용한 항균 나노섬유 제조)

  • Hwang, Seok-Ho;Ahn, Kyung-Hwan;Cha, Heechul;Kim, Jeong-Yeol;Hwang, Hong-Gu;Huh, Wansoo;Lee, Sangwon
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.386-390
    • /
    • 2009
  • In this study, sulfadiazine acrylamide monomer was synthesized by the reaction of sulfadiazine, known as an antibiotic substance, with acryloyl chloride. The monomer was characterized by $^1H-NMR$, and $^{13}C-NMR$. Using the synthesized sulfadiazine acrylamide monomer and styrene monomer, a copolymer, poly(styrene-co-sulfadiazine), was obtained by the free radical copolymerization and characterized by $^1H-NMR$, GPC, DSC and TGA. The copolymer nanofibers web has been successfully prepared by electrospinning technique under DMF solution. The diameter of the nanofibers was in the range between 500 and 800 nm. Antibacterial activity of the nanofiber web was evaluated utilizing the colony counting method against Staphylococcus aureus and Escherichia coli.

Diseases of Aquaculture Animals and Prevention of Drug Residues (양식어류의 질병과 수산동물용 의약품의 잔류방지 대책)

  • Heo, Gang-Joon;Shin, Kwang-Soon;Lee, Mun-Han
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 1992.07a
    • /
    • pp.7-19
    • /
    • 1992
  • Fish pathology is one of the main scientific bases upon which this expansion in aquaculture has been dependent and requires a wide knowledge of the environmental constraints, the physiology and characteristics of the various pathogens, the responses of the host and the methods by which they may be controlled. The primary disease and parasite problems in aquaculture animals relate to viral, bacterial, fungal and protozoan epizootics. Parasitic nematodes, trematodes and cestodes are commonly found in aquaculture animals, but seldom are they present in concentrations sufficinet to cause significant problems. When an epizootic does occur and chemical treatment is indicated, the appropriate chemical must be selected and properly applied. We have antibiotics, sulfa, nitrofuran and other chemicals for treatment of fish diseases. Some may be mixed with the fred during formulation, added to the pellets of feed as a surface coating, given in the dorm of an injection or used as a bath. Even though a drug or chemical has been officially approved for use in aquaculture, the substance should never be used unless there is a clear need. Some of the reasions for this view are as follows: (1) the constant use of antibiotics can lead to the development of resistant strains of bacteria, (2) biofilter efficiency may be impaired or destroyed by chemicals added to closed recirculating water systems, and (3) the injudicious use of chemicals can have a damaging effect on the environment as well as on human.

  • PDF

Quantitative Exposure Assessment of Various Chemical Substances in a Wafer Fabrication Industry Facility

  • Park, Hyun-Hee;Jang, Jae-Kil;Shin, Jung-Ah
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.39-51
    • /
    • 2011
  • Objectives: This study was designed to evaluate exposure levels of various chemicals used in wafer fabrication product lines in the semiconductor industry where work-related leukemia has occurred. Methods: The research focused on 9 representative wafer fabrication bays among a total of 25 bays in a semiconductor product line. We monitored the chemical substances categorized as human carcinogens with respect to leukemia as well as harmful chemicals used in the bays and substances with hematologic and reproductive toxicities to evaluate the overall health effect for semiconductor industry workers. With respect to monitoring, active and passive sampling techniques were introduced. Eight-hour long-term and 15-minute short-term sampling was conducted for the area as well as on personal samples. Results: The results of the measurements for each substance showed that benzene, toluene, xylene, n-butyl acetate, 2-methoxy-ethanol, 2-heptanone, ethylene glycol, sulfuric acid, and phosphoric acid were non-detectable (ND) in all samples. Arsine was either "ND" or it existed only in trace form in the bay air. The maximum exposure concentration of fluorides was approximately 0.17% of the Korea occupational exposure limits, with hydrofluoric acid at about 0.2%, hydrochloric acid 0.06%, nitric acid 0.05%, isopropyl alcohol 0.4%, and phosphine at about 2%. The maximum exposure concentration of propylene glycol monomethyl ether acetate (PGMEA) was 0.0870 ppm, representing only 0.1% or less than the American Industrial Hygiene Association recommended standard (100 ppm). Conclusion: Benzene, a known human carcinogen for leukemia, and arsine, a hematologic toxin, were not detected in wafer fabrication sites in this study. Among reproductive toxic substances, n-butyl acetate was not detected, but fluorides and PGMEA existed in small amounts in the air. This investigation was focused on the air-borne chemical concentrations only in regular working conditions. Unconditional exposures during spills and/or maintenance tasks and by-product chemicals were not included. Supplementary studies might be required.

Evaluation of membrane fouling characteristics due to manganese and chemical cleaning efficiency in microfiltration membrane process (막여과 정수처리공정에서 망간에 의한 막오염 특성 및 화학세정효율 평가)

  • Kang, Joon-Seok;Park, Seogyeong;Song, Jiyoung;Jeong, Ahyoung;Lee, Jeong-Jun;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.539-549
    • /
    • 2017
  • In water treatment process using microfiltration membranes, manganese is a substance that causes inorganic membrane fouling. As a result of analysis on the operation data taken from I WTP(Water Treatment Plant), it was confirmed that the increase of TMP was very severe during the period of manganese inflow. The membrane fouling fastened the increase of TMP and shortened the service time of filtration or the cleaning cycle. The TMP of the membrane increased to the maximum of $2.13kgf/cm^2$, but it was recovered to the initial level ($0.17kgf/cm^2$) by the 1st acid cleaning step. It was obvious that the main membrane fouling contaminants are due to inorganic substances. As a result of the analysis on the chemical waste, the concentrations of aluminum(146-164 mg/L) and manganese(110-126 mg/L) were very high. It is considered that aluminum was due to the residual unreacted during coagulation step as a pretreatment process. And manganese is thought to be due to the adsorption on the membrane surface as an adsorbate in feed water component during filtration step. For the efficient maintenance of the membrane filtration facilities, optimization of chemical concentration and CIP conditions is very important when finding the abnormal level of influent including foulants such as manganese.

A study on the Recognition of Material Safety Data Sheets and Safety of Handling Harmful Chemicals in Dental Hygienists (치과위생사의 물질안전보건자료 인식도와 유해화학물질 취급 시 안전 실태에 관한 연구)

  • Kim, Eun-Kyoung;Chung, Kyung-Yi
    • Journal of Digital Convergence
    • /
    • v.16 no.4
    • /
    • pp.185-194
    • /
    • 2018
  • The purpose of this study was to understand the dental hygienist's perception of dental materials and to understand the safety status of harmful chemicals. The study was conducted from January to February 2015 for 250 dental hygienists working in Gwangju Metropolitan City. as a result, the degree of recognition of MSDS for dental materials was higher with age (P <0.05) and higher in dental hygienist (P <0.001) working at dental hospital. (P <0.001), and the factors affecting the perception of first aid treatment were positively correlated with experience of hazard education (P <0.001). Therefore, by understanding the MSDS awareness of dental materials by dental hygienists and the safety situation in the handling of hazardous chemical substances, we provide basic data for establishing proper recognition of safety in the handling of harmful chemical substances and developing educational programs to prevent accidents.

Removal of Ammonia in Water using Acid-impregnated Activated Carbon and Dynamic Membrane System (산 첨착활성탄과 동적막 공정을 이용한 수중 암모니아 제거)

  • Choi, Won Kyung;Shin, Dong-Ho;Lee, Yong Taek
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.310-316
    • /
    • 2006
  • In this study, activated carbon in a powder form was used to remove dissolved ammonia which causes a fouling smell in water. Since the adsorption capacity of common powder activated carbon is not high enough, we prepared powder activated carbon deposited on an acid solution to enhance the adsorption capacity. The acid-impregnated activated carbon was applied on the surface of porous fibril support ($10{\sim}50{\mu}m$) by which adsorption and separation processes take place simultaneously by varying effective pressure. As the result, the ammonia removal efficiency is above 60% in the mixing process which is 10~15% higher than general powder activated carbon. From the result of an experiment on the pure permeable test of a dynamic membrane, its transmittance is 400~700 LMH (liter per hour), indicating that the prepared membrane works as a microfiltration membrane. Therefore, it is expected that the membrane prepared in this way would improve the efficiency of water treatment than conventional membranes.

Isobaric Vapor-Liquid Equilibrium of 1-propanol and Benzene System at Subatmospheric Pressures (일정압력하에서 1-propanol/benzene 계의 기-액 상평형)

  • Rho, Seon-Gyun;Kang, Choon-Hyoung
    • Korean Chemical Engineering Research
    • /
    • v.56 no.2
    • /
    • pp.222-228
    • /
    • 2018
  • Benzene is one of the most widely used basic materials in the petrochemical industry. Generally, benzene exists as a mixture with alcohols rather than as a pure substance. Further, the alcohols-added mixtures usually exhibit an azeotropic composition. In this context, knowledge of the phase equilibrium behavior of the mixture is essential for its separation and purification. In this study, the vapor-liquid equilibrium data were measured in favor of a recirculating VLE apparatus under constant pressure for the 1 - propanol / benzene system. The measured vapor - liquid equilibrium data were also correlated by using the UNIQUAC and WILSON models and the thermodynamic consistency test based on the Gibbs/Duhem equation was followed. The results of the phase equilibrium experiment revealed RMSEs (Root Mean Square Error) and AADs (Average Absolute Deviation) of less than 0.05 for both models, indicating a good agreement between the experimental value and the calculated value. The results of the thermodynamic consistency test also confirmed through the residual term within ${\pm}0.2$.

A Study on the Fabrication of Multi-Walled Nanotubes (MWCNT) Based Thin Film and Chemical Sensor Operation Characteristics (Multi-Walled Carbon Nanotubes (MWCNT) 인쇄박막의 제작과 화학센서 동작 특성에 관한 연구)

  • Noh, Jae Ha;Choi, Junseck;Ko, Dongwan;Seo, Joonyoung;Lee, Sangtae;Jung, Jung-Yeul;Chang, Jiho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.181-185
    • /
    • 2020
  • Hazardous and noxious substance (HNS) detection sensors were fabricated using multi-walled carbon nanotubes (MWCNTs) and various binder materials for ion batteries. To obtain uniformly printed films, the printing precision according to the substrate cleaning method was monitored, and the printing paste mixing ratio was investigated. Binders were prepared using styrene butadiene rubber + carboxymethyl cellulose (SBR+CMC), polyvinylidene fluoride + n-methyl-2-pyrrolidene (PVDF+NMP), and mixed with MWCNTs. The surface morphology of the printed films was examined using an optical microscope and a scanning electron microscope, and their electrical properties are investigated using an I-V sourcemeter. Finally, sensing properties of MWCNT printed films were measured according to changes in the concentration of the chemical under the various applied voltages. In conclusion, the MWCNT printed films made of (SBR+CMC) were found to be feasible for application to the detection of hazardous and noxious chemicals spilled in seawater.

Damage Effects Modeling by Chlorine Leaks of Chemical Plants (화학공장의 염소 누출에 의한 피해 영향 모델링)

  • Jeong, Gyeong-Sam;Baik, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.76-87
    • /
    • 2018
  • This study describes the damage effects modeling for a quantitative prediction about the hazardous distances from pressurized chlorine saturated liquid tank, which has two-phase leakage. The heavy gas, chlorine is an accidental substance that is used as a raw material and intermediate in chemical plants. Based on the evaluation method for damage prediction and accident effects assessment models, the operating conditions were set as the standard conditions to reveal the optimal variables on an accident due to the leakage of a liquid chlorine storage vessel. A model of the atmospheric diffusion model, ALOHA (V5.4.4) developed by USEPA and NOAA, which is used for a risk assessment of Off-site Risk Assessment (ORA), was used. The Yeosu National Industrial Complex is designated as a model site, which manufactures and handles large quantities of chemical substances. Weather-related variables and process variables for each scenario need to be modelled to derive the characteristics of leakage accidents. The estimated levels of concern (LOC) were calculated based on the Gaussian diffusion model. As a result of ALOHA modeling, the hazardous distance due to chlorine diffusion increased with increasing air temperature and the wind speed decreased and the atmospheric stability was stabilized.