• Title/Summary/Keyword: Chemical mechanical polishing

Search Result 500, Processing Time 0.032 seconds

Optimization of chemical mechanical polishing for bulk AlN single crystal surface (화학적 기계적 연마 공정을 통한 bulk AlN 단결정의 표면 가공)

  • Lee, Jung Hun;Park, Cheol Woo;Park, Jae Hwa;Kang, Hyo Sang;Kang, Suk Hyun;Lee, Hee Ae;Lee, Joo Hyung;In, Jun Hyeong;Kang, Seung Min;Shim, Kwang Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.1
    • /
    • pp.51-56
    • /
    • 2018
  • To evaluate surface characteristics of AlN single crystal grown by physical vapor transport (PVT) method, chemical mechanical polishing (CMP) were performed with diamond slurry and $SiO_2$ slurry after mechanical polishing (MP), then the surface morphology and analysis of polishing characteristics of the slurry types were analyzed. To estimate how pH of slurry effects polishing process, pH of $SiO_2$ slurry was controlled, the results from estimating the effect of zeta potential and MRR (material removal rate) were compared in accordance with each pH via zeta potential analyzer. Eventually, surface roughness RMS (0.2 nm) could be derived with atomic force microscope (AFM).

Pad Surface Characteristics and their Effect on Within Wafer Non-Uniformity in Chemical Mechanical Polishing (화학 기계적 연마에서 패드표면 특성이 웨이퍼 불균일도에 미치는 영향)

  • Jeong, Suk-Hoon;Lee, Hyun-Seop;Jeong, Moon-Ki;Shin, Woon-Ki;Lee, Sang-Jik;Park, Boum-Young;Kim, Hyoung-Jae;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.58-58
    • /
    • 2009
  • Uniformity related issues in chemical mechanical polishing (CMP) are within wafer non-uniformity (WIWNU), wafer to wafer non-uniformity (WTWNU), planarity and dishing/erosion. Here, the WIWNU that originates from spatial distribution of independent variables such as temperature, sliding distance, down force and material removal rate (MRR) during CMP, relies to spatial dependency. Among various sources of spatial irregularity, hardness and modulus of pad and surface roughness in sources for pad uniformity are great, especially. So, we investigated the spatial variation of pad surface characteristics using pad measuring system (PMS) and roughness measuring system. Reduced peak height ($R_{pk}$) of roughness parameter shows a strong correlation with the removal rate, and the distribution of relative sliding distance onwafer during polishing has an effect on the variation of $R_{pk}$ and WIWNU. Also, the results of pad wear profile thorough developed pad profiler well coincides with the kinematical simulation of conditioning, and it can contribute for the enhancement of WIWNU in CMP process.

  • PDF

A Study on Stick-slip Friction and Scratch in Cu CMP (Cu CMP에서 스틱-슬립 마찰과 스크래치에 관한 연구)

  • Lee, Hyun-Seop;Park, Boum-Young;Jeong, Suk-Hoon;Jeong, Jae-Woo;Seo, Heon-Deok;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.653-654
    • /
    • 2005
  • Stick-slip friction is one of the material removal mechanisms in tribology. This stick-slip friction occurs when the static friction force is larger than the dynamic friction force, and make the friction curve fluctuated. In the friction force monitoring system for chemical mechanical polishing(CMP), the friction force also vibrates just as stick-slip friction. It seems that the stick-slip friction causes scratches on the surface of moving parts. In this paper, A study on the scratches which occur during copper CMP was conducted in a view of stick-slip friction.

  • PDF

Development of the Magnetic Abrasive Using Sr-Ferrite and GC (Sr-Ferrite와 GC를 이용한 자기연마재 개발)

  • Yun, Yeo-Kwon;Kim, Sang-Baek;Kim, Hee-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.13-19
    • /
    • 2011
  • The magnetic polishing is the useful method to finish using magnetic power of magnet. That method is one of precision polishing techniques and has an aim of the clean technology using for the pure of gas and inside of the clean pipe. The magnetic abrasive polishing method is not so common for machine that it is not spreaded widely. There are rarely researcher in this field because of non-effectiveness of magnetic abrasive. Therefore, in this paper deals with development of the magnetic abrasive using Sr-Ferrite. In this development, abrasive grain GC used to resin bond fabricated low temperature. And Sr-Ferrite of magnetic abrasive powder fabricated that Sr-Ferrite was crused into 200 mesh. The XRD analysis result show that only GC abrasive and Sr-Ferrite crystal peaks detected which explains resin bond was not any more chemical reaction. From SEM analysis it is found that GC abrasive and Sr-Ferrite were strong bonding with each other by bond. The magnetic polishing is performed by polishing the surface of pipe by attracting magnetic abrasives with magnetic fields. This can be widely applied for finishing machinery fabrications such as various pipes and for other safety processes. In this paper, we could have investigated in to the changes of the movement of magnetic abrasive grain. In reference to this result, we could have made the experiment which is set under the condition of the magnetic flux density, polishing velocity according to the form of magnetic brush.

Effects of Citric Acid as a Complexing Agent on Material Removal in Cu CMP (Cu CMP에서 Citric Acid가 재료 제거에 미치는 영향)

  • Jung Won-Duck;Park Boum-Young;Lee Hyun-Seop;Jeong Hea-Do
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.889-893
    • /
    • 2006
  • Chemical mechanical polishing (CMP) achieves surface planrity through combined mechanical and chemical means. The role of slurry is very important in metal CMP. Slurry used in metal CMP normally consists of oxidizers, complexing agents, corrosion inhibitors and abrasives. This paper investigates the effects of citric acid as a complexing agent for Cu CMP with $H_2O_2$. In order to study chemical effects of citric acid, X-ray photoelectron spectroscopy (XPS) was peformed on Cu sample after etching test. XPS results reveal that CuO, $Cu(OH)_2$ layer decrease but $CU/CU_2O$ layer increase on Cu sample surface. To investigate nanomechanical properties of Cu sample surface, nanoindentation was performed on Cu sample. Results of nanoindentation indicate wear resistance of Cu surface decrease. According to decrease of wear resistance on Cu surface removal rate increases from $285\;{\AA}/min\;to\;8645\;{\AA}/min$ in Cu CMP.

The Effect of Pad Groove Density on CMP Characteristics (패드 그루브의 밀도변화가 연마특성에 미치는 영향)

  • Park Kihyun;Jung Jaewoo;Lee Hyunseop;Seo Heondeok;Jeong Seokhun;Lee Sangjik;Jeong Haedo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.27-33
    • /
    • 2005
  • Polishing pads play an important role in chemical mechanical polishing(CMP) which has recently been recognized at the most effective method to achieve global planarization. In this paper, we have investigated CMP characteristics as a change of groove density of polishing pads. The parameter $(K_n)$ is proposed to estimate groove density of pad. The $K_n$ is defined as groove area divided by pitch area. As the groove density value increased, removal rate increased to some point and then gradually saturated in case of increasing the groove density excessively. In addition Within wafer non-uniformity(WIWNU) worse as groove density increased excessively, although WIWNU improved as groove density increased. Also the uniformity of temperature of pad surface decreased as the groove density increased. It was because that the cooling effect increased as groove density increased. In other words, increasing the groove density which means the apparent contact area of pad has influence on amount of discharge of slurry during polishing process.

Characteristic of the Wear and Lubrication using the Friction Froce Measurement in CMP Process (CMP 공정에서 마찰력 측정을 통한 마멸 및 윤활 특성에 관한 연구)

  • Park, Boum-Young;Kim, Hyoung-Jae;Seo, Heon-Deok;Kim, Goo-Youn;Lee, Hyun-Seop;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.231-234
    • /
    • 2004
  • Chemical mechanical polishing(CMP) process was studied in terms of tribology in this paper. CMP performed by the down force and the relative motion of pad and wafer with the slurry is typically tribological system composed of friction, wear and lubrication. The piezoelectric quartz sensor for friction force measurement was installed and the friction force was detected during CMP process. Various coefficient of friction was attained and analyzed with the kind of pad, abrasive and the abrasive concentration. The lubrication regime is also classified with ${\eta}v/p(\eta,\;v\;and\;p;$ the viscosity, relative velocity and pressure). Especially, the co-relation not only between the friction force and the removal per unit distance but also between the coefficient of friction and within-wafer-nonuniformity was estimated.

  • PDF

Dry cleaning for metallic contaminants removal after the chemical mechanical polishing (CMP) process (Chemical Mechnical Polishing(CMP) 공정후의 금속오염의 제거를 위한 건식세정)

  • 전부용;이종무
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.2
    • /
    • pp.102-109
    • /
    • 2000
  • It is difficult to meet the cleanliness requirement of $10^{10}/\textrm{cm}^2$ for the giga level device fabrication with mechanical cleaning techniques like scrubbing which is widely used to remove the particles generated during Chemical Mechanical Polishing (CMP) processes. Therefore, the second cleaning process is needed to remove metallic contaminants which were not completely removed during the mechanical cleaning process. In this paper the experimental results for the removal of the metallic contaminants existing on the wafer surface using remote plasma $H_2$ cleaning and UV/$O_3$ cleaning techniques are reported. In the remote plasma $H_2$ cleaning the efficiency of contaminants removal increases with decreasing the plasma exposure time and increasing the rf-power. Also the optimum process conditions for the removal of K, Fe and Cu impurities which are easily found on the wafer surface after CMP processes are the plasma exposure time of 1min and the rf-power of 100 W. The surface roughness decreased by 30-50 % after remote plasma $H_2$ cleaning. On the other hand, the highest efficiency of K, Fe and Cu impurities removal was achieved for the UV exposure time of 30 sec. The removal mechanism of the metallic contaminants like K, Fe and Cu in the remote plasma $H_2$ and the UV/$O_3$ cleaning processes is as follows: the metal atoms are lifted off by $SiO^*$ when the $SiO^*$is evaporated after the chemical $SiO_2$ formed under the metal atoms reacts with $H^+ \; and\; e^-$ to form $SiO^*$.

  • PDF

Planarization of Cu intereonnect using ECMP process (전기화학 기계적 연마를 이용한 Cu 배선의 평탄화)

  • Jeong, Suk-Hoon;Seo, Heon-Deok;Park, Boum-Young;Park, Jae-Hong;Lee, Ho-Jun;Oh, Ji-Heon;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.79-80
    • /
    • 2007
  • Copper has been used as an interconnect material in the fabrication of semiconductor devices, because of its higher electrical conductivity and superior electro-migration resistance. Chemical mechanical polishing (CMP) technique is required to planarize the overburden Cu film in an interconnect process. Various problems such as dishing, erosion, and delamination are caused by the high pressure and chemical effects in the Cu CMP process. But these problems have to be solved for the fabrication of the next generation semiconductor devices. Therefore, new process which is electro-chemical mechanical planarization/polishing (ECMP) or electro-chemical mechanical planarization was introduced to solve the. technical difficulties and problems in CMP process. In the ECMP process, Cu ions are dissolved electrochemically by the applying an anodic potential energy on the Cu surface in an electrolyte. And then, Cu complex layer are mechanically removed by the mechanical effects between pad and abrasive. This paper focuses on the manufacturing of ECMP system and its process. ECMP equipment which has better performance and stability was manufactured for the planarization process.

  • PDF

A Numerical Analysis Using CFD for Effective Process at CMP Equipment (CFD를 이용한 CMP장비의 효과적인 공정을 위한 수치해석적 연구)

  • Lee, Sue-Yeon;Kim, Kwang-Sun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.139-144
    • /
    • 2011
  • CMP process is an essential element in the semiconductor product processes in Chemical Mechanical Polishing. Taken as a whole, CMP is one process, but concretely, it is a detail process which consists of polishing, cleaning, and so on. Especially, the polishing and cleaning are key points in the whole process. Polishing rate is the most important factor and is related with deposition of slurry in the polishing process. Each outlet velocities is the most important factors in cleaning process. And when the velocities are more uniform, the cleaning becomes more effective. In this research, based on these factors, we performed a numerical analysis for effective polishing and cleaning which can be applied to industrial field. Consequently, we figured out that more than one opened nozzle is more effective than one opened nozzle at the polishing pad in case of this research. And we confirmed that the revised models have the uniform velocity distribution more than the previous model of the cleaning nozzle.