• Title/Summary/Keyword: Chemical imaging

Search Result 365, Processing Time 0.027 seconds

Improving the Productivity of Single-Chain Fv Antibody Against c-Met by Rearranging the Order of its Variable Domains

  • Kim, Yu-Jin;Neelamegam, Rameshkumar;Heo, Mi-Ae;Edwardraja, Selvakumar;Paik, Hyun-Jong;Lee, Sun-Gu
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1186-1190
    • /
    • 2008
  • Single-chain Fv (scFv) antibody against c-Met is expected to be employed in clinical treatment or imaging of cancer cells owing to the important biological roles of c-Met in the proliferation of malignancies. Here, we show that the productivity of scFv against c-Met in Escherichia coli is significantly influenced by the orientation of its variable domains. We generated anti-c-Met scFv antibodies with two different domain orders (i.e., $V_L$-linker-$V_H$ and $V_H$-linker-$V_L$), expressed them in the cytoplasm of E. coli trx/gor deleted mutant, and compared their specific activities as well as their productivities. Productivity of total and functional anti-c-Met scFv with $V_H/V_L$ orientation was more than five times higher than that with $V_L/V_H$ format. Coexpression of DsbC enhanced the yield of soluble amounts of anti-c-Met scFv protein for both constructs. The purified scFv antibodies of the two different formats exhibited almost the same antigen-binding activities. We also compared the productivities and specific activities of anti-c-Met diabodies with $V_H/V_L$ or $V_L/V_H$ formats and obtained similar results to the case of scFv antibodies.

Energy Band Structure and Photocatalytic Property of Fe-doped Zn2TiO4 Material

  • Jang, Jum-Suk;Borse, Pramod H.;Lee, Jae-Sung;Lim, Kwon-Taek;Jung, Ok-Sang;Jeong, Euh-Duck;Bae, Jong-Seong;Won, Mi-Sook;Kim, Hyun-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.3021-3024
    • /
    • 2009
  • $Zn_2Ti_{1-x}Fe_xO_4\;(0\;{\leq}\;x\;{\leq}\;0.7)$ photocatalysts were synthesized by polymerized complex (PC) method and investigated for its physico-chemical as well as optical properties. $Zn_2Ti_{1-x}Fe_xO_4$ can absorb not only UV light but also visible light region due to doping of Fe in the Ti site of $Zn_2TiO_4$ lattice because of the band transition from Fe 3d to the Fe 3d + Ti3d hybrid orbital. The photocatalytic activity of Fe doped $Zn_2TiO_4$ samples for hydrogen production under UV light irradiation decreased with an increase in Fe concentration in $Zn_2TiO_4$. Consequently, there exists an optimized concentration of iron for improved photocatalytic activity under visible light (${\lambda}{\leq}$420 nm)

Nanoscale quantitative mechanical mapping of poly dimethylsiloxane in a time dependent fashion

  • Zhang, Shuting;Ji, Yu;Ma, Chunhua
    • Advances in nano research
    • /
    • v.10 no.3
    • /
    • pp.253-261
    • /
    • 2021
  • Polydimethylsiloxane (PDMS) is one of the most widely adopted silicon-based organic polymeric elastomers. Elastomeric nanostructures are normally required to accomplish an explicit mechanical role and correspondingly their mechanical properties are crucial to affect device and material performance. Despite its wide application, the mechanical properties of PDMS are yet fully understood. In particular, the time dependent mechanical response of PDMS has not been fully elucidated. Here, utilizing state-of-the-art PeakForce Quantitative Nanomechanical Mapping (PFQNM) together with Force Volume (FV) and Fast Force Volume (FFV), the elastic moduli of PDMS samples were assessed in a time-dependent fashion. Specifically, the acquisition frequency was discretely changed four orders of magnitude from 0.1 Hz up to 2 kHz. Careful calibrations were done. Force data were fitted with a linearized DMT contact mechanics model considering surface adhesion force. Increased Young's modulus was discovered with increasing acquisition frequency. It was measured 878 ± 274 kPa at 0.1 Hz and increased to 4586 ± 758 kPa at 2 kHz. The robust local probing of mechanical measurement as well as unprecedented high-resolution topography imaging open new avenues for quantitative nanomechanical mapping of soft polymers, and can be extended to soft biological systems.

Reconstruction of Magnetic Resonance Phase Images using the Compressed Sensing Technique (압축 센싱 기법을 이용한 MRI 위상 영상의 재구성)

  • Lee, J.E.;Cho, M.H.;Lee, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.464-471
    • /
    • 2010
  • Compressed sensing can be used to reduce scan time or to enhance spatial resolution in MRI. It is now recognized that compressed sensing works well in reconstructing magnitude images if the sampling mask and the sparsifying transform are well chosen. Phase images also play important roles in MRI particularly in chemical shift imaging and magnetic resonance electrical impedance tomography (MREIT). We reconstruct MRI phase images using the compressed sensing technique. Through computer simulation and real MRI experiments, we reconstructed phase images using the compressed sensing technique and we compared them with the ones reconstructed by conventional Fourier reconstruction technique. As compared to conventional Fourier reconstruction with the same number of phase encoding steps, compressed sensing shows better performance in terms of mean squared phase error and edge preservation. We expect compressed sensing can be used to reduce the scan time or to enhance spatial resolution of MREIT.

Clinical Application of $^{18}F-FDG$ PET and PET-CT in Adrenal Tumor (부신종양에서 $^{18}F-FDG$ PET 및 PET-CT의 임상 이용)

  • Hwang, Kyung-Hoon;Choi, Duck-Joo;Lee, Min-Kyung;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.130-133
    • /
    • 2008
  • Adrenal tumors are increasingly detected by widespread use of anatomical imaging such as a, MRI, etc. For these adrenal tumors, differentiation between malignancy and benignancy is very important. In diagnostic assessment of adrenal tumor, $^{18}F-FDG$ PET and PET-CT have been reported to have high diagnostic performance, especially, very excellent performance in evaluation of adrenal metastasis in the oncologic patient. In cases of adrenal incidentalomas, $^{18}F-FDG$ PET or PET-CT is helpful if a or chemical-shift MRI is inconclusive. $^{18}F-FDG$ PET and PET-CT may be applied to the patients with MIBG-negative pheochromocytomas. In summary, $^{18}F-FDG$ PET and PET-CT are expected to be effective diagnostic tools in the management of adrenal tumor.

Flocculation of microalgae using extracellular polymeric substances (EPS) extracted from activated sludge

  • Dong, Dandan;Seo, Dongmin;Seo, Sungkyu;Lee, Jae Woo
    • Membrane and Water Treatment
    • /
    • v.9 no.3
    • /
    • pp.147-153
    • /
    • 2018
  • This study investigates the role of microbial extracellular polymeric substances (EPSs) as bioflocculants to harvest microalgae (water-microalgae separation). The EPS extracted from waste activated sludge (WAS) by heat extraction were fractionated into soluble EPS (S-EPS), loosely-bound EPS (LB-EPS) and tightly-bound EPS (TB-EPS) forms. All the EPSs facilitated the flocculation of microalgal cells from stable growth medium. Of those EPSs, the TB-EPS showed the highest flocculating activity (FA) resulting in the substantial decrease in the amount of EPS added in terms of total organic carbon (TOC) during flocculation. The FA of microalgae was improved with the increase in TB-EPS dose, however, excessive dose of TB-EPS adversely affected it due to destabilization. Both LB- and TB-EPS could be utilized for flocculating microalgae as a sustainable option to the existing chemical-based flocculants. In addition to the conventional assessments, the effectiveness of the two bioflocculants for floc forming was also confirmed using a novel assessment of lens-free shadow imaging technique (LSIT), which was firstly applied for the rapid and quantitative assessment of microalgal flocculation.

A Design of Fire Detection System based on Infrared Thermal Imaging & CCD Camera (적외선 열영상 및 CCD 카메라 기반 화재감지 시스템 설계)

  • Kim, Tae Wan;Choi, Chang Yong;Lee, Dong Myung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.597-598
    • /
    • 2013
  • A lot of fire and crime accidents are caused to a significant national loss. For example, the network and power facilities in national industry facilities, the fire risk region in large scale factories such as nuclear and thermal power plants, large-sized buildings, cultural properties, metal and steel mills, chemical plants, oil refineries. The development of a fire detection system that can detects the temperature and movement of objects as high-level quality is essential to prevent these incidents and accidents fundamentally. In this paper, the fire detection system based on infrared thermal imaging & CCD camera id designed to solve these problems.

  • PDF

Microflow of dilute colloidal suspension in narrow channel of microfluidic-chip under Newtonian fluid slip condition

  • Chun Myung-Suk;Lee Tae Seok;Lee Kangtaek
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.4
    • /
    • pp.207-215
    • /
    • 2005
  • We present a finite difference solution for electrokinetic flow in rectangular microchannels encompassing Navier's fluid slip phenomena. The externally applied body force originated from between the nonlinear Poisson-Boltzmann field around the channel wall and the flow-induced electric field is employed in the equation of motion. The basic principle of net current conservation is applied in the ion transport. The effects of the slip length and the long-range repulsion upon the velocity profile are examined in conjunction with the friction factor. It is evident that the fluid slip counteracts the effect by the electric double layer and induces a larger flow rate. Particle streak imaging by fluorescent microscope and the data processing method developed ourselves are applied to straight channel designed to allow for flow visualization of dilute latex colloids underlying the condition of simple fluid. The reliability of the velocity profile determined by the flow imaging is justified by comparing with the finite difference solution. We recognized the behavior of fluid slip in velocity profiles at the hydrophobic surface of polydimethylsiloxane wall, from which the slip length was evaluated for different conditions.

Application of X-ray Computer Tomography (CT) in Cattle Production

  • Hollo, G.;Szucs, E.;Tozser, J.;Hollo, I.;Repa, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.12
    • /
    • pp.1901-1908
    • /
    • 2007
  • The aim of this series of experiments was to examine the opportunity for application of X-ray computer tomography (CT) in cattle production. Firstly, tissue composition of M. longissimus dorsi (LD) cuts between the $11-13^{th}$ ribs (in Exp 1. between the $9-11^{th}$ ribs), was determined by CT and correlated with tissue composition of intact half carcasses prior to dissection and tissue separation. Altogether, 207 animals of different breeds and genders were used in the study. In Exp. 2 and 3, samples were taken from LD cuts, dissected and chemical composition of muscle homogenates was analysed by conventional procedures. Correlation coefficients were calculated among slaughter records, tissues in whole carcasses and tissue composition of rib samples. Results indicated that tissue composition of rib samples determined by CT closely correlated with tissue composition results by dissection of whole carcasses. The findings revealed that figures obtained by CT correlate well with the dissection results of entire carcasses (meat, bone, fat). Close three-way coefficients of correlation (r = 0.80-0.97) were calculated among rib eye area, volume of cut, pixel-sum of adipose tissue determined by CT and intramuscular fat or adipose tissue in entire carcasses. Estimation of tissue composition of carcasses using equations including only CT-data as independent variables proved to be less reliable in prediction of lean meat and bone in carcass ($R^2 = 0.51-0.86$) than for fat (($R^2 = 0.83-0.89$). However, when cold half carcass weight was also included in the equation, the coefficient of determination exceeded $R^2 = 0.90$. In Exp. 3 tissue composition of rib samples by CT were compared to the results of EUROP carcass classification. Findings revealed that CT analysis has higher predictive value in estimation of actual tissue composition of cattle carcasses than EUROP carcass classification.

Use of magnetic resonance imaging for evaluation of therapeutic response in breast cancer-related lymphedema: A systematic review

  • Forte, Antonio Jorge;Boczar, Daniel;Kassis, Salam;Huayllani, Maria T.;McLaughlin, Sarah A.
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.305-309
    • /
    • 2020
  • Breast cancer treatment-related lymphedema (BCRL) is a common comorbidity in breast cancer survivors. Although magnetic resonance imaging (MRI) is widely used to evaluate therapeutic response of patients with various medical conditions, it is not routinely used to evaluate lymphedema patients. We conducted a systematic review of the literature to identify studies on the use of MRI to evaluate therapy for BCRL. We hypothesized that MRI could provide information otherwise not possible through other examinations. On October 21, 2019, we conducted a systematic review on the PubMed/MEDLINE and Scopus databases, without time frame or language limitations, to identify studies on the use of MRI to evaluate therapy for BCRL. We excluded studies that investigated other applications of MRI, such as lymphedema diagnosis and surgical planning. Of 63 potential articles identified with the search, three case series fulfilled the eligibility criteria. In total, 53 patients with BCRL were included and quantitatively evaluated with MRI before and after manual lymphatic drainage. Authors used MRI or MR lymphagiography to investigate factors such as lymphatic vessel cross-sectional area, tissue water relaxation time (T2), and chemical exchange saturation transfer. The only study that compared MRI measurement with standard examinations reported that MRI added information to the therapy evaluation. MRI seems to be a promising tool for quantitative measurement of therapeutic response in patients with BCRL. However, the identified studies focused on only manual lymphatic drainage and were limited by the small numbers of patients. More studies are necessary to shed light on the topic.