• 제목/요약/키워드: Chemical antigen

검색결과 125건 처리시간 0.024초

Latex 응집반응과 간접형광항체법을 이용한 개 톡소플라즈마병의 혈청학적 진단 (Serodiagnosis of canine toxoplasmosis by latex agglutination and indirect fluorescent antibody test)

  • 이병훈;이응구;서명득
    • 대한수의학회지
    • /
    • 제32권4호
    • /
    • pp.641-647
    • /
    • 1992
  • This study was conducted to determine the serum antibodies against toxoplasma in the artificially infected dogs, pet and street dogs by latex agglutination (LA) and indirect fluorescent antibody (IFA) test. LA test was carried out with commercial Toxo-MT kit (Eiken chemical Co.) and IFA test was carried out with rabbit-anti-dog IgG labelled with FITC (Cappel Co.) and toxo-antigen slides prepared in laboratory. The results obtained were as follows ; 1. Antibodies to Toxoplasma gondii in the artificially infected dogs were detected firstly at the Day 8 in IFA and Day 9 in LA test after inoculation. Positive antibody reactions by these tests were declined gradually afterward but maintained up to 12 weeks. 2. In LA test serum antibody titers in 310 test sera were shown as 10 cases(32%) in 1 : 32.5(1.0%) in 1 : 64, 4(1.3%) in 1 : 128 and 2(0.7%) in 1 : 256. In IFA test serum antibody titers 310 test sera were shown as 17 cases(5.5%) in 1 : 64, 8(2.6%) in 1 : 128 and 5(1.6%) in 1 : 256. 3. In the total of 310 sera from pet and street dogs toxoplasma antibody positive rates were 21 cases (6.8%) by LA and 30 cases (9.7%) by IFA test and the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 4. In the total of 115 sera from pet dogs toxoplasma antibody positive rates were 12 cases(10.4%) by LA and 15(13.0%) by IFA test. And in the 195 street dogs the positive rates were 9 cases(4.6%) by LA and 15(7.7%) by IFA test. Also, the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 5. Agreement of reactivity between LA and IFA test for 310 sera was 91.3% in total of 283 cases consisting of 12 cases(3.9%) of both LA and IFA positive and 271 cases(87.4%) of LA and IFA negative. 6. LA test was almostly equivalent to the IFA test in producibility and proved to be a simple tool for the screening of toxoplasma antibody in laboratory.

  • PDF

매독진단(梅毒診斷)을 위(爲)한 신속(迅速)한 혈장항체검사법(血漿抗體檢査法)에 관(關)한 연구(硏究) (Studies on the Rapid Plasma Reagin(RPR) Card Test for the Diagnosis of Syphilis)

  • 김주덕;유준;김현주
    • 대한미생물학회지
    • /
    • 제3권1호
    • /
    • pp.15-23
    • /
    • 1968
  • For the effective control of Syphilis, many investigators have developed a more rapid, simple and economical screening serological test which is adequately sensitive and specific. To fulfill the requirements of a more rapid serologic test for syphlis, a substitute for the conventional serum specimen was needed since considerable time and labor are involved in the processing of blood to serum. Burdon suggested the use of plasma in the serologic tests for syphilis as a substitute for serum. He noticed that plasma was more sensitive than serum in the Kline and Kahn tests, and attributed this to the presence of more antibody-like substance, "reagin" in plasma than in serum. However, to make plasma sufficiently sensitive, it was necessary to inactivate plasma by heating at a temperature of $56^{\circ}C$ for about 30 minutes. Heating of plasma resulted in the precipitation of fibrinogen which made centrifugation necessary to obtain dear plasma. Since the chief disadvantage to the use of unheated plasma(or serum) was a reduction in sensitivity of results-which probably was due to a labile factor such as complement-Portnoy et al began to consider rapid chemical methods of inactivation of plasma(or serum). They experienced that choline chloirde was shown to be anticomplementary which suggested its use as an inactivating agent for unheated plasma(or serum). In 1959 Portnoy et al reported the Rapid Plasma Reagin(RPR) Test for syphilis which is a more rapid, economical and simple. But still this test has many disadvantages as a rapid performing, field and office procedure, because it requires the usual laboratory equipments such as centrifuge, rotating machine, microscope etc. To substitute these disadvantages of the RPR test, in 1962, Portnoy et al developed the Rapid Plasma Reagin(RPR) card test for syphilis, which has the following advantages: a) Simplicity and rapidity of performance, b) Requires no laboratory equipments, c) Stable antigen suspension, d) Adequate sensitivity and specificity. This RPR card test can be used as a rapidly performing and screening test in field investigation, outpatient clinics, small laboratories and hospitals doing limited syphilis serology, and predonor in blood bank. Private clinic which has limited laboratory equipment and technic for syphilis serology can also use this RPR card test as a tool in the rapid diagnosis of syphilis. It was thought that this RPR card test is a useful tool in Korea for private physician and mass survey for syphilis diagnosis. But Portnoy patented the reagents needed for the performing the RPR card test. Therefore authors developed newly the reagents and according to Portnoy's method evaluated the newly developed. RPR card test compared with the VDRL, Kolmer CF, and RPCF tests. The RPR card and VDRL tests were performed plasma and serum from the total 1,132 cases. Among these 1,131 cases, 521 were syphilis suspected laboratory specimens, and 611 were syphilis unsuspected healthy young men. After screening with these two tests, the RPR card and VDRL tests, reactive specimens to the above one or both tests were retested by the Kolmer CF and RPCF tests.

  • PDF

생분해성 고분자, 폴리하이드록시알카노에이트를 이용한 바이오센서 칩 연구와 그 응용 (A Research and Application of Polyhydroxyalkanoates in Biosensor Chip)

  • 박태정;이상엽
    • KSBB Journal
    • /
    • 제22권6호
    • /
    • pp.371-377
    • /
    • 2007
  • 나노기술과 바이오기술의 융합연구에 의해 나노바이오기술이 발전되고 있다. 나노바이오기술의 중요한 응용연구 중의 하나로서, 진단이나 바이오센서 분야에서 단백질-단백질 및 단백질-바이오물질간의 상호작용을 연구하기 위한 단백질 센서 칩이 개발되어 왔다. 본 논문에서는 단백질의 선택적 고정화를 위한 새로운 생체고분자 기질로 PHA를 이용하는 첫 번째 예로서, 단백질-단백질 및 항원-항체 반응의 구현을 나타내고자 하였다. 본 시스템은 PHA 표면 위에서 PHA depolymerase의 SBD와의 선택적 결합에 기반한 것으로, PHA depolymerase의 SBD와 융합된 단백질이 PHA가 코팅된 표면 위에 spotting 될 수 있고 미세접촉인쇄방법에 의해 PHA 위에 미세패턴이 제조되어지는 것을 알 수 있었다(52, 53). 이러한 새로운 전략이 PHA depolymerase의 SBD와 다른 단백질을 융합함으로서 미세 spotting과 미세패터닝이 가능하게 되었고 항원-항체의 생물학적 반응을 통해 많은 바이오센서 칩 연구에 응용될 수 있음을 확인하였다. 또한, PHA 마이크로 비드에도 PHA depolymerase의 SBD와 융합된 단백질을 고정시킴으로서 항원-항체 반응을 유도할 수 있음을 확인하였다(54). PHA의 구조를 변경하여 PHA 기판, PHA 필름, PHA 미세패턴, PHA 마이크로 비드 등을 이용할 수 있으며 multiplex assay를 동시에 진행할 수 있는 다양한 융합 단백질을 사용할 수 있을 것이다. 생분해성 플라스틱으로서 성공적으로 개발된 PHA를 이용한 새로운 플랫폼 기술이 PHA depolymerase의 SBD를 이용함으로서 특이적이고 선택적인 단백질의 고정화에 이용될 수 있음을 확인하였다. 본 전략이 다양한 단백질-단백질 및 단백질-바이오물질 반응을 이용한 바이오칩 및 바이오센서의 응용연구에 유용하게 사용될 것이다.

국소 표면 플라즈몬 공명 (LSPR) 기반 비표지 바이오칩 제작 및 바이오센서로의 응용 (Fabrication of Label-Free Biochips Based on Localized Surface Plasmon Resonance (LSPR) and Its Application to Biosensors)

  • 김도균;박태정;이상엽
    • KSBB Journal
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 2009
  • 현재까지 연구 개발된 바이오칩 및 센서의 경우에는 생체분자 상호작용의 분석을 수행하기 위해서 효소나 형광 물질 등과 같은 표지물질을 생체분자에 주입할 필요성이 있었다. 이러한 표지작업은 단백질 등과 같이 고차구조를 형성하는 생체분자에 있어서 그 분자인식능을 저하시키는 문제가 발생하게 된다. 그리고 표지작업은 일련의 조작이 필요하기 때문에 조작의 복잡성을 띄게 되고, 간편성을 저해하는 문제가 발생하게 되며, 분석 결과를 얻기 위해서는 장시간을 필요로 하게 된다. 또한, 생체분자 상호작용의 분석에 적용되는 측정장치도 대형화하게 되어 온사이트 모니터링에 이용하기 어렵다. 이러한 문제점들을 해결하기 위해서 비표지로 생체분자의 상호작용 분석이 가능한 SPR 광학특성, QCM 및 전기화학법 등을 이용한 비표지 바이오칩 및 센서가 개발되었다. 하지만 표지 바이오칩 및 센서와 마찬가지로 장치의 대형화 및 복잡화, 간편성 및 감도 등에 문제가 있었다. 따라서 지금까지 개발되어진 표지 및 비표지 바이오칩의 문제들을 해결하기 위해서 나노구조에서만 발현되는 새로운 광학특성인 LSPR을 기반으로 하는 새로운 형태의 코어-쉘 구조 나노입자 바이오칩이 제작되었다. 코어-쉘 나노입자 바이오칩의 표면에 수직방향으로부터 입사광을 조사하고 바이오칩 표면으로부터 반사된 반사광을 검출기로 검출하여 흡수 스펙트럼을 소형의 분광기로 해석함으로서 코어-쉘 나노입자 바이오칩 기반 비표지 광학 바이오센서를 완성하였다. 또한 단백질 항원-항체 반응에 대한 비표지 검출 및 정량특성을 평가한 결과, 감도, 간편성, 유연성, 폭넓은 응용성 등에 양호한 특성을 확인할 수 있었다. 이상에서 살펴본 바와 같이, 코어-쉘 나노입자 바이오칩 기반 비표지 광학 바이오센서는 생체분자 상호작용의 분석에 많이 이용되고 있는 단백질, DNA, 세포 등의 생체분자에 유연하게 대처할 수 있을 것으로 생각되어지며, 그 밖에 의료, 식품분석, 환경 및 공정 모니터링 등 분야에 폭넓게 이용될 것으로 기대되고 있다. 또한 본 코어-쉘 나노입자 바이오칩 기반 비표지 광학 바이오센서는 소형으로 저렴한 분광기를 이용하여 측정을 실시하고 있기 때문에 온사이트 모니터링에의 적용도 가능할 것으로 생각된다.

Taxol 방사면역측정을 위한 $^{125}I-Iodotyraminehemisuccinyltaxol\;(^{125}ITHT)$의 제조 (Preparation of $^{125}I-Iodotyraminehemisuccinyltaxol\;(^{125}ITHT)$ for Competitive Taxol Radioimmunoassay)

  • 이태섭;오옥두;최태현;김현석;홍준표;이은숙;최창운;임상무
    • 대한핵의학회지
    • /
    • 제36권2호
    • /
    • pp.121-132
    • /
    • 2002
  • 목적: Taxol(Paclitaxel)은 난소암과 유방암의 치료제로 사용되고 있으며, 치료시 적절한 체내 혈중농도를 유지함으로서 치료효과를 극대화하기 위해서는 taxol의 혈중농도를 측정하는 것이 필요하다. 본 실험에서는 taxol의 혈중농도를 측정할 수 있는 방사면역측정시스템에 표지항원으로 사용할 수 있는 taxol 유도체의 방사성표지화합물을 합성하고, 이를 이용하여 방사면역측정법을 시행할 수 있는지의 여부를 확인하고자 하였다. 대상 및 방법: Taxol과 succinic anhydride를 무수 pyridine을 용매로 하여 반응시켜 hemisuccinyltaxol을 합성하고, 합성된 hemisuccinyltaxol과 tyramine을 isobutylchloroformate를 coupling agent로 사용하여 tyraminehemisuccinyltaxol을 합성하고 HPLC로 분리 정제 하였다. 산화제인 Chloramine-T($5.25mg/ml,\;10{\mu}{\ell}$)를 사용하여 tyraminehemisuccinyltaxol($4mg/ml,\;30{\mu}{\ell}$)에 $^{125}I(1\;mCi)$를 방사성요오드화하고 HPLC를 이용하여 표지수율을 산정하였다. 정제된 tyraminehenisuccinyltaxol과 $^{125}I-iodotyraminehemisuccinyltaxol$을 80% acetonitrile 수용액에 녹여 $4^{\circ}C$$37^{\circ}C$로 보관하면서, 각 시간대별로 화학적 순도와 방사 화학적 순도를 결정하여 그 안정도를 HPLC를 이용하여 확인하였다. $[^{125}I]Iodotyraminehemisuccinyltaxol$를 방사성표지항원으로 사용하여 taxol에 대한 단클론항체(3G5A7)의 역가를 검정하였으며, $0{\sim}100nM$ 농도범위에서 taxol 농도의 증가에 따른 표준투여응답곡선을 작성하였다. 결과: Hemisuccinyltaxol은 79.9%의 수율로 합성되었으며, tyraminehemisuccinyltaxol의 합성수율은 19.5%였다. $^{125}I-iodotyraminehemisuccinyltaxol$의 표자수율은 93%이었다. tyraminehemisuccinyltaxol은 7일까지도 96.5% 이상의 순도를 보여 비교적 안정함을 확인하였으며, $^{125}I-iodotyraminehemisuccinyltaxol$은 3일까지는 93.4% 이상으로 안정하였고 또한 7일 경과시에는 86.1% 이상의 순도를 보였다. taxol에 대한 단클론항체(3G5A7)의 역가를 검정하여 1:256의 역가를 나타냄을 확인하였으며, taxol 농도에 따른 표준투여응답곡선은 taxol과 방사표지 taxol 유도체간에 경쟁적으로 사용되어 직선성 (R2=0.971)을 나타내었다. 결론: taxol의 경쟁적 방사면역측정법의 방사성 추적자로서 방사성표지 taxol 유도체인 $^{125}I-iodotyraminehemisuccinyltaxol$을 이용한 방법이 유용함을 확인하였다.