• Title/Summary/Keyword: Chemical agent detection

Search Result 62, Processing Time 0.023 seconds

A Study on the Development of a Control and Monitoring System for Impressed Current Corrosion Protection (선박용 차세대 외부전원방식 제어 및 감시 시스템 UNIT 개발)

  • Kim, Y.B.;Kim, B.Y.;Suh, J.H.;Kim, J.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.104-110
    • /
    • 2006
  • Corrosion has been around for all of recorded history. Cathodic protection is the electrical solution to the corrosion problem. Corrosion is not exactly a new topic. It has been around since the beginning of time. Corrosion is simply the loss of material resulting from current leaving a metal, following through a medium, and returning to the metal at a different point. Corrosion takes many forms and has various names, such as oxidation, rust, chemical, and bacteria action. Regardless of the agent, all corrosion is the result of electrical current flow. Various methods are used to treat corrosion or to try to prevent ti. Some of these include chemical treatment. coatings, and electrical current. Especially, proper impressed current can stop corrosive action on the protected surface. In this article, we introduce the Impressed Current Cathodic Protection (ICCP) Control and monitoring system developed by ourselves. The ICCP system is composed of a power supply, anode, reference electrode and controller. The main issue is to control the current flow on the desired value such that it is possible to force a metal to be more negative(cathodic) than the natural state. From the this process, we can achieve the cathodic protection. Of course, in the developed system, the necessary functions are possessed, such as remote control, monitoring of system fault detection etc. Some experimental results show the system performance and usefulness.

  • PDF

Analysis of Phoxim Residue in Animal Food Production (Cattle and Pig) by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 식육(소, 돼지)중 잔류 phoxim 분석)

  • Park, Mi-Sun;Lee, Jin-Joo;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.626-632
    • /
    • 2011
  • Phoxim, which is one of veterinary drugs, is a well-known antiparasitic agent in wide use. In this paper, phoxim was extracted from cattle and pig tissue using solid-phase extraction (SPE) employing a silica cartridge with acetonitrile. Liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for the analysis of phoxim from animal tissue was presented. Phoxim was detected on a $C_{18}$ column ($2.1{\times}100\;mm$, $3.5\;{\mu}m$) using a mobile phase of 0.1% formic acid in water and acetonitrile. A linear correlation observed in the calibration curves for cattle (0.0048~2.0 mg/kg) and pig (0.0055~2.0 mg/kg) showed above $r^2$=0.995. Accuracy measured at concentrations ranging from 0.0048 to 0.2 mg/kg was the range of 68.2~106.9%. Limit of detection (LOD) and limit of quantitation (LOQ) were the range of 0.0014~0.0017 mg/kg and 0.0048~0.0055 mg/kg, respectively. The precision (RSD%) was below 11.2%.

Determination of Boron by Ion Pair Liquid Chromatography with Chromotropic Acid (Chromotropic Acid를 착화제로 이용한 이온쌍 액체 크로마토그래피에 의한 붕소의 분리와 정량)

  • Yun, Young Ja;Yu, Gu Yong
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.288-293
    • /
    • 1995
  • The separation and determination of boron with chromotropic acid (1,8-Dihydroxynaphthalene-3,6-disulfonic acid) as a complex agent has been studied using ion pair liquid chromatography. The use of tetrabutylammonium bromide added as an ion pair reagent to mobile phase (MeOH 61%, phosphate buffer 39% pH=8.5) allowed good separation of boron-chromotrophic acid complex anion and chromotrophic acid on poly(styrene-divinylbenzene) based reversed phase column (PRP-1, 15 $cm{\times}4.6$ mm i.d.). The complex formation between boric acid and chromotrophic acid was enhanced in the presence of 0.1 M tetrabutylammonium bromide, resulting in high sensitivity. The linear calibration was achieved over the boron concentration range of 0.5∼1000 ${\mu}g/L.$ The detection limit was 0.5 ${\mu}g/L$ (S/N=2). The proposed method was applied to the determination of boron in commercially available chemicals, $Na_2SO_4$, NaOH, KCl.

  • PDF

Ionic liquid coated magnetic core/shell CoFe2O4@SiO2 nanoparticles for the separation/analysis of trace gold in water sample

  • Zeng, Yanxia;Zhu, Xiashi;Xie, Jiliang;Chen, Li
    • Advances in nano research
    • /
    • v.10 no.3
    • /
    • pp.295-312
    • /
    • 2021
  • A new ionic liquid functionalized magnetic silica nanoparticle was synthesized and characterized and tested as an adsorbent. The adsorbent was used for magnetic solid phase extraction on ICP-MS method. Simultaneous determination of precious metal Au has been addressed. The method is simple and fast and has been applied to standard water and surface water analysis. A new method for separation/analysis of trace precious metal Au by Magnetron Solid Phase Extraction (MSPE) combined with ICP-MS. The element to be tested is rapidly adsorbed on CoFe2O4@SiO2@[BMIM]PF6 composite nano-adsorbent and eluted with thiourea. The method has a preconcentration factor of 9.5-fold. This method has been successfully applied to the determination of gold in actual water samples. Hydrophobic Ionic Liquids (ILs) 1-butyl-3-methylimidazole hexafluorophosphate ([BMIM]PF6) coated CoFe2O4@SiO2 nanoparticles with core-shell structure to prepare magnetic solid phase extraction agent (CoFe2O4@SiO2@ILs) and establish a new method of MSPE coupled with inductively coupled plasma mass spectrometry for separation/analysis of trace gold. The results showed that trace gold was adsorbed rapidly by CoFe2O4@SiO2@[BMIM]PF6 and eluanted by thiourea. Under the optimal conditions, preconcentration factor of the proposed method was 9.5-fold. The linear range, detection limit, correlation coefficient (R) and relative standard deviation (RSD) were found to be 0.01~1000.00 ng·mL-1, 0.001 ng·mL-1, 0.9990 and 3.4% (n = 11, c = 4.5 ng·mL-1). The CoFe2O4@SiO2 nanoparticles could be used repeatedly for 8 times. This proposed method has been successfully applied to the determination of trace gold in water samples.

Pharmacokinetic analysis for the development of new potent anti-HIV-1 agents, the KR-V series (새로운 항HIV-1제, KR-V series의 개발을 위한 약물동태연구)

  • Lee, Young-mi;Kim, Jin-suk;Han, Sang-seop;Shin, Ho-chul
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.3
    • /
    • pp.471-478
    • /
    • 2000
  • The pharmacokinetic properties of KR-V compounds, recently developed as new anti-HIV agents, were studied after i.v. and p.o. administration in rats. The concentrations of the KR-V series were determined in rat plasma using an high-performance liquid chromatography (HPLC)-UV detection system. Of the 19 KR-V compounds investigated in the present study, only KR-V 3, 10, 14, 16 and 18-1 showed oral bioavailability. The plasma concentration-time data could be adequately described by an one-compartment open model. In the i.v. kinetic study (10mg/kg), the CLt of KR-V 3, 10, 14 and 16 (>4L/hr/kg) were significantly higher than that of KR-V 18-1 (1.1 L/hr/kg). The AUC of KR-V 18-1 was greater ($8.97{\mu}g{\cdot}hr/ml$) than that of the other compounds, but the Vd (0.58 L/kg) was lower. In the p.o. kinetic study (50mg/kg), although the t-1/2 of KR-V 18-1 was shorter than that of the other compounds, the AUC ($3.659{\mu}g{\cdot}hr/ml)$ and $C_{max}(1.891{\mu}g/ml$) were markedly higher. In a seperated in vitro experiment, only KR-V 18-1, of the 5 compounds with bioavailibility, exhibits potent activity against HIV-1 mutant strains. Therefore, KR-V 18-1 is expected to become a new potent anti-AIDS drug candidate/lead compound.

  • PDF

Altered Gene Profiles using KISTCHIP-400 in MCF-7 cells after Exposure to Di(2-ethylhexyl) Phthalate (DEHP) and Dibutyl Phthalate (DBP)

  • Yun, Hye-Jung;Kim, Youn-Jung;Kim, Eun-Young;Ryu, Jae-Chun
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.174-174
    • /
    • 2003
  • There are many synthetic chemicals, such as di(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP), used in chemical reaction processes in industry. The establishment of toxicity and detection of synthetic chemicals that may pose a genetic hazard in our enviornment is subjects of great concern at present DEHP, a ubiquitous phthalate plasticizer, induces a wide range of developmental and reproductive toxicities in mammals. DEHP belongs to the large diverse class of peroxisome proliferator compounds, which include herbicides, hypolipidemic drugs. DBP is a plasticizer used to products containing nitrocellulose, polyvinyl acetate, and polyvinyl chloride such as food wraps and blood bags. DBP is also used in cosmetics as a solvent and fixative for perfumes, a suspension agent for solids, an antifoamer, a skin emollient, and hair spray The present study was performed to examine patterns of gene expression in MCF-7 cells following DEHP and DBP exposure. Changes in gene expression were determined by microarray analysis using KISTCHIP-400 including 401 endocrine related genes based on public database and research papers. Of the genes analysis, we determined that genes detected by array showed a 2-fold or greater change in their expression level(increase or decrease). The results of this study demonstrate that a number of genes were differentially expressed in MCF-7 cells but these changes were not significant. Therefore, we keep going this study using microarray analysis and future studies will examine changes of gene expression on time-course and does treatment in variable cell lines.

  • PDF

Establishment of Measurement of Human Cytomegalovirus with in situ ELISA (in situ ELISA를 이용한 사람세포거대바이러스의 측정법 개발)

  • Hwang, Eung-Soo;Kim, Jin-Hee;Park, Chung-Gyu;Cha, Chang-Yong
    • The Journal of Korean Society of Virology
    • /
    • v.30 no.2
    • /
    • pp.125-130
    • /
    • 2000
  • Infection with human cytomegalovirus (HCMV) is of considerable clinical relevance after placental transmission and in immunosuppressed patients such as transplant recipients or patients with AIDS. The rapid detection method of HCMV has been required to overcome the time-consuming methods such as classical plaque assay or other immunological methods. This study was performed to establish the in situ ELISA, in which human lung fibroblasts infected with HCMV were fixed and used directly as antigen in 96 well culture plate. Expressed HCMV antigens were detected with HCMV-specific monoclonal antibodies. This method could detect HCMV dose-dependently upto $3{\times}10^2\;pfu/ml$. Antiviral activity of ganciclovir could be assayed within the known range of effective dose. This result showed that HCMV could be quantitated by in situ ELISA. The chemical, which was selected on the basis of component analysis in natural product, was tested to have the anti-HCMV activity by in situ ELISA, and three among five samples were found to have anti-HCMV activity with the dose-dependent manner. Conclusively in situ ELISA could be useful method for quantitation of HCMV and screening antiviral activity of samples to HCMV.

  • PDF

Highly sensitive and selective detection of cyanide in aqueous solutions using a surface acoustic wave chemical sensor (표면음향파 화학센서를 이용한 수용액 중 시안화이온의 선택적인 고감도 검출)

  • Lee, Soo Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.473-479
    • /
    • 2016
  • We report a highly selective and sensitive 200 MHz Surface Acoustic Wave (SAW) sensor that can detect cyanide ion in aqueous solution using surface immobilized thioester molecules in combination with gold nanoparticles (AuNPs). To construct the sensor device, a monolayer of thioester compound was immobilized on the SAW sensor surface. At the sensor surface, hydrolysis of thioester group by nucleophilic addition of cyanide occurred and the resulting free thiol unit bound to AuNP to form thiol-AuNP conjugate. For the signal enhancement, gold staining signal amplification process was introduced subsequently with gold (III) chloride trihydrate and reducing agent, hydroxylamine hydrochloride. The SAW sensor showed a detection ability of $17.7{\mu}M$ for cyanide in aqueous solution and demonstrated a saturation behavior between the frequency shift and the concentration of cyanide ion. On the other hand, our SAW sensor had no activities for other anions such as fluoride ion, acetate ion and sulfate ion, moreover, no significant interference observed by other anions. Finally, all the experiments were carried out in-house developed sensor and fluidics modules to obtain highly reproducible results.

Determination of Cd(II) after Preconcentration onto Microcrystalline p-Dichlorobenzene Loaded with 2-Mercaptobenzothiazole (2-Mercaptobenzothiazole이 내포된 p-Dichlorobenzene 미세결정으로 예비농축시킨 후 Cd(II) 정량)

  • Yoon, Ju-Im;Choi, Hee-Seon
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • A sensitive technique for the determination of trace Cd(II) in various real samples after preconcentration onto microcrystalline p-dichlorobenzene loaded with 2-mercaptobenzothiazole was developed. Several experimental conditions such as the pH of the sample solution, the amount of chelating agent 2-mercaptobenzothiazole, the amount of adsorbent p-dichlorobenzene-2-MBT, and the flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. Cu(II) interfered with more seriously than any other ions. However, the interference by Cu(II) could be overcome sufficiently by adjusting tartrate ion concentration to be 0.01M or by controlling the amount of 2-mercaptobenzothiazole contained in 0.20 g p-dichlorobenzene to be 0.12 g. The dynamic range, the correlation coefficient ($R^2$) and the detection limit obtained by this proposed technique were $0.5{\sim}30$ ng $mL^{-1}$, 0.9962, and 0.39 ng $mL^{-1}$, respectively. Thus, good results were obtained by the use of p-dichlorobenze as adsorbent matrix. For validating this proposed technique, the aqueous samples(wastewater, stream water, and reservoir water) and the plastic sample were used. Recovery yields of $93{\sim}104$ % were obtained. By F test, these measured data were not different from ICP-MS data at 95 % confidence level. Based on the results from the experiment, it was found that this proposed technique could be applied to the preconcentration and determination of Cd(II) in various real samples.

Preconcentration and Extraction of Copper on Activated Carbon Using 4-Amino-2, 3-dimethyl-1-phenyl-3-pyrazoline or 4-(4-methoxybenzylidenimin) thiophenole (4-Amino-2,3-dimethyl-1-phenyl-3-pyrazoline 또는 4-(4-Methoxybenzylidenimin)thiophenole을 이용한 활성탄에서의 구리의 예비 농축 및 추출)

  • Ghaedi, Mehrorang;Ahmadi, Farshid;Karimi, Hajir;Gharaghani, Shiva
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.23-31
    • /
    • 2006
  • carbon modified methods were used for the preconcentration and determination of copper in some real samples using the flame atomic absorption spectrometry. The copper ions was adsorbed quantitatively on the activated carbon due to their complexation with 4- amino-2, 3-dimethyl-1-phenyl-3-pyrazoline (ADMPP) or 4-(4- methoxybenzylidenimin) thiophenole (MBITP). The adsorbed copper on solid phase was eluted quantitatively using small amount of nitric acid. The influence of important parameters including pH, amount of carrier, flow rate, amount of activated carbon and type and concentration of eluting agent for obtaining maximum recovery were investigated. The methods based on ADMPP and MBITP at optimum conditions is linear over concentration range of 0.05-1.5 g mL-1 and 0.05-1.2 g mL-1 of copper with correlation coefficient of 0.9997 and 0.9994 and both detection limit of 1.4 ng mL-1, respectively. The preconcentration leads to enrichment factor of 310 and break through volume of 1550 mL for both ligands. The method has a good tolerance limit of interfering ion and a selectivity that has been successfully applied for the determination of copper content in real sample such as tap, spring, river and waste water.