• Title/Summary/Keyword: Chemical Lasers

Search Result 46, Processing Time 0.025 seconds

A Spectroscopic Study on Singlet Oxygen Production from Different Reaction Paths Using Solid Inorganic Peroxides as Starting Materials

  • Li, Qingwei;Chen, Fang;Zhao, Weili;Xu, Mingxiu;Fang, Benjie;Zhang, Yuelong;Duo, Liping;Jin, Yuqi;Sang, Fengting
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1656-1660
    • /
    • 2007
  • Using solid inorganic peroxides (including Li2O2, Na2O2, SrO2 and BaO2) as starting materials, three reaction paths for singlet oxygen (1O2) production were developed and studied. Their 1O2 emission spectra in the near- IR region and visible region from these reaction paths were simultaneously recorded by a near-IR sensitive Optical Multichannel Analyzer and a visible sensitive Optical Spectrum Analyzer, respectively. The comparison of their 1O2 emission spectra indicated that: (1) in term of the efficiency for 1O2 production, the gasliquid- solid reaction path (in which Cl2 or HCl and H2O reacted with the solid inorganic peroxides suspension in CCl4) was prior to the gas-solid reaction path (in which Cl2 or HCl reacted with the solid inorganic peroxides suspension in CCl4), but was inferior to the gas-liquid reaction path (in which Cl2 or HCl reacted with the solid inorganic peroxides solution in H2O or D2O); (2) the alkali metal peroxides (such as Li2O2 and Na2O2) was prior to the alkaline earth metal peroxides (such as SrO2 and BaO2) as the solid reactants, and Cl2 was favorable than HCl as the gas reactant in efficiency for 1O2 production in these reaction paths.

Development of Ejector System for Chemical Lasers Operating (I) - Design Parameter Study of Supersonic Ejector for Chemical Lasers Operating - (화학레이저 구동용 이젝터 시스템 개발 (I) - 화학레이저 구동용 초음속 이젝터 설계 변수 연구 -)

  • Kim, Se-Hoon;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1673-1680
    • /
    • 2003
  • It is essential to operate chemical lasers with supersonic ejector system as the laser output power goes up. In this research, ejector design parameter study was carried out for optimal ejector design through understanding the ejector characteristics and design requirements for chemical lasers operating. Designed ejector was 3D annular type with 2$^{nd}$ -throat geometry and pressurized air was used for primary flow. Ejector design was carried out with two steps, quasi-1D gas dynamics was used for first design and commercial code was used to verify the first design. In this study, to get the effect of ejector geometry on its performance, three cases of primary nozzle area ratio and 2$^{nd}$ -throat cross sectional area and two cases of 2$^{nd}$ -throat L/D ratio experiments were carried out. Primary and secondary pressures were measured to get the mass flow rate ratio, minimum secondary pressure, ejector starting pressure and unstarting pressure at every case. In the result, better performance than design level was shown and optimal ejector design method for chemical lasers was obtained.

Medical Laser (의료용 Laser)

  • 김덕원
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.107-113
    • /
    • 1990
  • Characteristics and applications of three major types of lasers are discussed. They are chemical-metabolic, thermal destructive, and nonthermal mechanical lasers. The thermal destructive lasers ($CO_2$, Argon, and Nd:YAG) are especially explained in detail with regard to energy density, wavelength, fluence, stage of thermal destruction, and advantages of laser surgery. Excimer and Q-swiched lasers are discussed as nonthermal mechanical ones. Delivery system, optical fiber and articulated arm, is also discussed. Finally, recent advancements of medical laser are included in the conclusion.

  • PDF

Study of Ejector System for cw High Power Chemical Lasers Operating (연속발진 고출력 화학레이저 구동용 이젝터 시스템 연구)

  • Kim, Se-Hoon;Jin, Jung-Kun;Kwon, Se-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1715-1719
    • /
    • 2004
  • An in-house supersonic ejector was designed to ensure low pressure and high speed scavenging of resonating cavity of chemical lasers. For given primary flow condition, 100g/s secondary mass flow rate was observed at the design pressure. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of diffuser at the secondary inlet further reduced diffuser upstream pressure to 1/4-1/5 relieving the local to the primary supply unit. In order to increase the secondary flow, we put two ejectors capable of removing 50g/s each of secondary flows together to deal with higher mass flow. Test of the parallel unit demonstrated the secondary flow rate was proportional to the numbers of individual units that were brought together. Additionally, flow calculations with a commercial code were carried out in every case of experiment and compared with results.

  • PDF

Development of an Ejector System for Operating of Chemical Lasers (III) - Development and Performance Validation of a Full-Scale Ejector System for High Power Chemical Lasers - (화학레이저 구동용 이젝터 시스템 개발 (III) - 고출력 화학레이저용 실물 크기의 이젝터 시스템 개발 및 성능 검증 -)

  • Kim, Se-Hoon;Jin, Jung-kun;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.9-15
    • /
    • 2005
  • From the geometric parameter study, an optimal ejector design procedure of pressure recovery system for chemical lasers was acquired. For given primary flow reservoir conditions, an up-scaled ejector was designed and manufactured. In the performance test, secondary mass flow rate of 100g/s air was entrained satisfying the design secondary pressure, $40{\sim}50torr$. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of the diffuser at the secondary inlet further reduced diffuser upstream pressure to 7torr. Lastly, the duplicate of apparatus (air 500g/s secondary mass flow rate each) was built and connected in parallel to assess proportionality behavior on a system to handle larger mass flow rate. Test and comparison of the parallel unit demonstrated the secondary mass flow rate was proportional to the number of individual units that were brought together maintaining the lasing pressure.

Optogalvanic Spectroscopy of U, Th and Rb using Diode Lasers (반도체 다이오드 레이저를 사용한 U, Th 및 Rb 의 Optogalvanic Spectroscopy 에 관한 연구)

  • Lee, Sang Cheon
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.1
    • /
    • pp.34-40
    • /
    • 1994
  • First observation of uranium using a diode laser was published recently. The experiment was performed by the optogalvanic spectroscopy using diode lasers. A laser source causes the current change in a hollow cathode discharge lamp when metal atoms in plasma absorb the diode laser light. The optogalvanic signal is collected by detecting the current change. This work is the extended investigation of our previous research, the uranium detection using a diode laser. New electronic transitions of uranium and thorium in 775∼850 nm were investigated using diode lasers. In addition, the Rb(Ⅰ) optogalvanic spectra at 780.02 nm and 794.76 nm were studied. The Rb(Ⅰ) spectrum at 780.02 nm showed the isotopic features and hyperfine splittings. This work provides a key idea that the diode lasers are useful in the specrochemical analysis of the radioactive actinides that have a rich spectrum with transitions which can be easily reached with AlGaAs diode lasers. Also, this study shows that the diode lasers can be an important tool to find the spectroscopic parameters of actinides and rare earth elements which have not known.

  • PDF

The treatment of peri-implantitis using various types of lasers (다양한 Laser를 이용한 Peri-Implantitis의 치료)

  • You, Jae-Seek;Kim, Su-Gwan;Ahn, Jong-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.12
    • /
    • pp.906-909
    • /
    • 2015
  • Peri-implantitis is the inflammatory process, such as edema, bleeding, pus, of the mucosa surrounding dental implants. As the symptoms become severe, the surrounding bone is absorbed causing the implant surface to be exposed. Clinicians treat periimplantitis in various ways since a gold standard for the treatment of peri-implantitis has not been established. Various treatment methods include mechanical, chemical surface treatment and surgical excision, and recently decontamination of the implant surface using various types of lasers has been proposed. Thus, this study reviews the types of lasers and its effects that can be used for the treatment of peri-implantitis.

Anomalous Emission Spectra Observed in InGaAs/AlGaAs Quantum-Wire Lasers (InGaAs/AlGaAs 양자선 래이저에서 관찰된 이상 방출 스펙트럼)

  • Kim, Kyoung-Chan;Kim, Tae-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2020-2021
    • /
    • 2004
  • Distributed optical feedback by gain coupling in V-groove quantum-wire lasers is investigated using InGaAs/AlGaAs active materials grown by metalorganic chemical vapor deposition (MOCVD). In order to avoid grating overgrowth during the fabrication of DFB structures, a newly developed constant MOCVD growth method is employed. Gain anisotropy in emission spectra near Bragg wavelength, resulting from optical feedback along the DFB direction, is clearly observed at room temperature.

  • PDF

Theoretical comparison of electron beam initiated HF/DF laser output characteristics

  • Lee, Young-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.374-376
    • /
    • 2007
  • The output characteristics of HF and DF lasers were compared theoretically. The simulation code shows the good agreement with the experimental results well. As results, the effect of chain termination reaction in $F_2$ rich mixture is larger than that of $SF_6$ rich mixture in HF and DF lasers.

The Studies on Treatment of Liver Disease Using Lasers and Acupuncture in Dogs (고양이에서 Lasers 및 침술을 이용한 신장질환 치료에 관한 연구)

  • 김명철;변흥섭;정종만;남윤이;김무강;정주영
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.325-330
    • /
    • 1998
  • The purpose of this study is to investigate the effect of acupuncture after the induction of acute kidney disease in dogs by ethylene glycol. Twenty four mixed breed, adult cats were used in the experiment. Ethylene glycol was administered orally at 1 ml/kg in 24 cats, and then 6 cats were treated by acupunchuture 6 cats were treated by electroacupuncture, 6 cats were treated by acupuncture and 6 cats were not treated as a control group. Treatment was done once daily far 4 dsys. The acupoint used were Gan-shu and Tai-xi. The effect of acnpuncture was evaluated by clinical symptom, blood chemical values, electrocardiogram (ECG) and histopathologkal findings. After treatement, acupuncture group revealed relatively fast recovery compared with other groups, in clinical symptoms, blood chemical values, ECG waves and histopathological findings. Laserpuncture group revealed secondly fast recovery compared with control group.

  • PDF