• Title/Summary/Keyword: Chemical Detection

Search Result 1,720, Processing Time 0.029 seconds

Effect of Doxycycline on the Acute Lung Injury Induced by Gut Ischemia/Reperfusion (장의 재관류로 유도된 급성폐손상에서의 Doxycyclin의 효과)

  • Lee, Young Man;Kwon, Sung Chul;Lee, Sang Chae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.5
    • /
    • pp.532-541
    • /
    • 2003
  • Background : Phospholipase $A_2$ ($PLA_2$) has been known to be involved in the pathogenesis of acute lung injury (ALI) including ARDS. Since doxycycline has the property of inhibiting secretory group II $PLA_2$, the therapeutic effect of doxycycline hyclate was investigated for gut ischemia/reperfusion (I/R)-induced ALI in Sprague-Dawley rats. Methods : ALI was induced in Sprague-Dawley rats by clamping of the superior mesenteric artery for 60 min, followed by 120 min of reperfusion. To confirm the pathogenetic mechanisms of this ALI associated with neutrophilic oxidative stress, we measured bronchoalveolar lavage (BAL) protein content and lung MPO, and performed cyto-chemical electron microscopy for detection of free radicals, assay of $PLA_2$ activity and cytochrome-c reduction assay. Results : In gut I/R-induced ALI rats, protein leakage, pulmonary neutrophil accumulation, free radical production and lung $PLA_2$ activity were all increased. These effects were reversed by doxycycline hyclate. Conclusion : Doxycycline appears to be effective in ameliorating the gut I/R-induced ALI by inhibiting $PLA_2$, thereby decreasing the production of free radicals from neutrophils.

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

Characteristics of Constructed SPR (Surface Plasmon Resonance) Sensor System for the Detection of Salmonella and hIgG Antigen-Antibody Reaction. (살모넬라와 면역글로블린(hIgG)의 항원-항체반응 감지를 위한 표면 플라즈몬 공명형 센서시스템의 특성)

  • Um, N.S.;Koh, K.N.;Hahm, S.H.;Kim, J.H.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.263-270
    • /
    • 1998
  • Surface Plasmon Resonance (SPR) sensor system, has rapid response and high sensitivity, can be applicable for detecting reaction times of many biospecific interactions. A SPR sensor system was constructed to detect the antigen-antibody reactions of salmonella and hIgG (human immunoglobulin G). Sensor chips made of gold thin film were used for detecting biological bindings of antigen and antibody reactions. The antigen and antibody reactions for salmonella and hIgG were carried out with various time intervals to observed characteristics of these reactions using SPR sensor system. The resonance angle shift changes were clearly observed at the time of salmonella or hIgG antibody injection into sample cell since each antibody was self-assembled on gold chip surface of the sensor. It was found that the antibodies of salmonella and hIgG reacted with its sensor chip surface in 10 minutes and 60 minutes respectively. And the antigens of both salmonella and hIgG were bound to its antibody within 1 minute.

  • PDF

HPLC-based Analysis of Biogenic Amines in Aging-Cheese (HPLC를 이용한 숙성치즈로부터 바이오제닉 아민 분석법 개발)

  • Park, Jong-Hyuk;Lee, Sang-Cheon;Moon, Hye-Jung;Oh, Jeon-Hui;Song, Gi-Bong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.3
    • /
    • pp.187-191
    • /
    • 2016
  • Biogenic amines have been used as chemical indicators of fermented foods. So far, several chromatography methods have been developed to detect biogenic amines in foods. However, few methods have identified these compound in domestic cheese. We analyzed the biogenic amines (histamine dihydrochloride, tyramine hydrochloride, ${\beta}$-phenylethylamine hydrochloride, putrescine dihydrochloride, cadaverine, spermidine, tryptamine hydrochloride, ethanolamine hydrochloride and butylamine) in cheese by using HPLC. The calibration curves of the biogenic amines were found to be linear over the concentration range of 10-50 ppm with a correlation coefficient of above 0.99. The limit of detection (LOD) and limit of quantitation (LOQ) of the biogenic amines in the given order were 3.7 and 11.3 ppm, 3.4 and 10.4ppm, 3.4 and 10.3 ppm, 4.0 and 12.2 ppm, 3.4 and 10.4 ppm, 3.4 and 10.5 ppm, 3.5 and 10.7 ppm, 4.1 and 12.5 ppm, and 3.4 and 10.4 ppm, respectively. Recovery rates of the biogenic amines in the given order were 112, 104, 93, 108, 91, 102, 101, and 92%, respectively. The findings of this study suggest that HPLC is a suitable method for the determination of biogenic amines, thereby indicating its potential application in the quality control of aging cheese.

Real-time Control of Biological Animal Wastewater Treatment Process and Stability of Control Parameters (생물학적 축산폐수 처리공정의 자동제어 방법 및 제어 인자의 안정성)

  • Kim, W.Y.;Jung, J.H.;Ra, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.251-260
    • /
    • 2004
  • The feasibility and stability of ORP, pH(mV) and DO as a real-time control parameter for SBR process were evaluated in this study. During operation, NBP(nitrogen break point) and NKP(nitrate knee point), which reveal the biological and chemical changes of pollutants, were clearly observed on ORP and pH(mV)-time profiles, and those control points were easily detected by tracking the moving slope changes(MSC). However, when balance of aeration rate to loading rate, or to OUR(oxygen uptake rate), was not optimally maintained, either false NBP was occurred on ORP and DO curves before the appearance of real NBP or specific NBP feature was disappeared on ORP curve. Under that condition, however, very distinct NBP was found on pH(mV)-time profile, and stable detection of that point was feasible by tracking MSC. These results might mean that pH(mV) is superior real-time control parameter for aerobic process than ORP and DO. Meanwhile, as a real-time control parameter for anoxic process, ORP was very stable and more useful parameter than others. Based on these results, a stable real-time control of process can be achieved by using the ORP and pH(mv) parameters in combination rather than using separately. A complete removal of pollutants could be always ensured with this real-time control technology, despite the variations of wastewater and operation condition, as well as an optimization of treatment time and capacity could be feasible.

Development of Rapid Analysis Method for Pesticide Residues by GC-MS/MS (GC-MS/MS를 이용한 잔류농약 신속검사법 개발)

  • Choi, Yong-Hoon;Nam, Hye-Seon;Hong, Hye-Mi;Lee, Jin-Ha;Chae, Kab-Ryong;Lee, Jong-Ok;Kim, Hee-Yun;Yoon, Sang-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.292-302
    • /
    • 2005
  • Condition of Ion-Trap gas chromatography-mass spectrometry (GC-MS) for rapid screening of 206-pesticides residues in agricultural foodstuffs was optimized. As applying a wide-bore column (10 m${\times}$0.53 mm, DF 0.25 um) connected with a fused silica restrictor (0.6 m${\times}$0.1 mm), a significant retention time reduction was obtained. Additionally, the shape of peaks was sharper and higher than classical GC's and GC-MS's, which allowed lower detection limits. To easily manage many spectral data, both of Electron Ionization(EI) and Chemical Ionization(CI) techniques were adopted in screening procedure. At the following steps, MS-MS technique were used to confirm screened analytes in complicated matrices.

Development of Methane Gas Leak Detector Using Mid-infrared Ray Sensors with $3.2\;{\mu}m$ ($3.2\;{\mu}m$ 중적외선 센서를 이용한 메탄가스누출검지기의 개발)

  • Park, Gyou-Tae;Lyu, Keun-Jun;Han, Sang-In;Oh, Jeong-Seok;Kim, Ji-Yoon;Ahn, Sang-Guk;Yoon, Myung-Seop;Kwon, Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.48-52
    • /
    • 2008
  • According to extremely industrial growth, gas facilities, equipments and chemical plants are gradually increased due to incremental demands of annual amount of gases. The safety management of gases, however, is still far from their requirements. Methane, the principal ingredient of natural gas, is inflammable and explosive and is much used in factories and houses. Therefore, these gas safety management is essential. So, we, with a program of the gas safety management, hope to develop the detection system of methane gas leak using mid-infrared ray LED and PD with $3.2\;{\mu}m$. The cryogenic cooling device is indispensible at laser but needless at LED driven on the room temperature if manufacturing optical sensor with $3.2\;{\mu}m$. It, consequently, is not only possible to implement for subminiature and portable type but also able to speedily detect methane of extremely small quantities because the $CH_4$ absorption intensity at $3.2\;{\mu}m$ is stronger than that at $1.67\;{\mu}m$. Our objective of research is to prevent gas leak accidents from occurring previously and to minimize the extent of damage from them.

  • PDF

ECR-PECVD 방법으로 제작된 DLC 박막의 기판 Bias 전압 효과

  • 손영호;정우철;강종석;정재인;황도원;김인수;배인호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.188-188
    • /
    • 2000
  • DLC (Diamond-Like Carbon) 박막은 높은 경도와 가시광선 및 적외선 영역에서의 광 투과도, 전기적 절연성, 화학적 안정성 및 저마찰.내마모 특성 등의 우수한 물리.화학적인 물성을 갖고 있기 때문에 여러 분야의 응용연구가 이루어지고 있다. 이러한 DLC 박막을 제작하는 과정에는 여러 가지가 있으나, 본 연구에서는 ECR-PECVD electron cyclotron resonance plasma enhanced chemical vapor deposition) 방법을 사용하였다. 이것은 최근에 많이 이용되고 있는 방법으로, 이온화률이 높을뿐만 아니라 상온에서도 성막이 가능하고 넓은 진공도 영역에서 플라즈마 공정이 가능한 장점이 있다. 기판으로는 4" 크기의 S(100)를 사용하였고, 박막을 제작하기 전에 진공 중에서 플라즈마 전처리를 하였다. 플라즈마 전처리는 Ar 가스를 150SCCM 주입시켜 5$\times$10-1 torr 의 진공도를 유지시키면서, ECR power를 700W로 고정하고, 기판 bias 전압을 -300 V로 하여 5분 동안 기판을 청정하였다. DLC 박막은 ECR power를 700W. 가스혼합비와 유량을 CH4/H2 : 10/100 SCCM, 증착시간을 2시간으로 고정하고, 기판 bias 전압을 0, -50, -75, -100, -150, -200V로 변화시켜가면서 제작하였다. 이때 ECR 소스로부터 기판까지의 거리는 150mm로 하였고, 진공도는 2$\times$10-2torr 였으며, 기판 bias 전압은 기판에 13.56 MHz의 RF power를 연결하여 RF power에 의해서 유도되는 negative DC self bias 전압을 이용하였다. 제작된 박막을 Auger electron spectroscopy, elastic recoil detection, Rutherford backscattering spectroscopy, X-ray diffraction, secondary electron microscopy, atomic force microscoy, $\alpha$-step, Raman scattering spectroscopu, Fourier transform infrared spectroscopy 및 micro hardness tester를 이용하여 기판 bias 전압이 DLC 박막의 특성에 미치는 영향을 조사하였다. 분석결과 본 연구에서 제작된 DLC 박막은 탄소와 수소만으로 구성되어 있으며, 비정질 상태임을 알 수 있었다. 기판 bias 전압의 증가에 따라 박막의 두께가 감소됨을 알 수 있었고, -150V에서는 박막이 거의 만들어지지 않았으며, -200V에서는 기판 표면이 식각되었다. 이것은 기판 bias 전압과 ECR 플라즈마에 의한 이온충돌 효과 때문으로 판단되며, 150V 이하에서는 증착되는 양보다 re-sputtering 되는 양이 더 많을 것으로 생각된다. 기판 bias 전압을 증가시킬수록 플라즈마에 의한 이온충돌 현상이 두드러져 탄소와 결합하고 있던 수소원자들이 떨어져 나가는 탈수소화 (dehydrogenation) 현상을 확인할 수 있었으며, 이것은 C-H 결합에너지가 C-C 결합이나 C=C 결합보다 약하여 수소 원자가 비교적 해리가 잘되므로 이러한 현상이 일어난다고 판단된다. 결합이 끊어진 탄소 원자들은 다른 탄소원자들과 결합하여 3차원적 cross-link를 형성시켜 나가면서 내부 압축응력을 증가시키는 것으로 알려져 있으며, hardness 시험 결과로 이것을 확인할 수 있었다. 그리고 표면거칠기는 기판 bias 전압을 증가시킬수록 더 smooth 해짐을 확인하였다.인하였다.

  • PDF

Determination of Free 4-hydroxyproline with Dansylchloride by HPLC in Human Urine (소변 중 4-hydroxyproline 분석에 관한 연구)

  • Lee, Keou-Weon;Cho, Young-Bong;Lee, Kyung-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.4
    • /
    • pp.282-286
    • /
    • 2002
  • Objectives : The level of 4-hydroxyproline (4-Hyp) in human urine was measured using high performance liquid chromatography (HPLC) with a fluorescence detector. This method is useful for medical examinations and investigating the radicals induced by physical, chemical, mental stresses. This method is superior to many published several methods in terms of its low cost and ability to analyze many samples. Methods : The urine from workers in a tire manufacturing company (22 male pre- and post-shift workers) and 18 office-workers as controls were analyzed. Data concerning age, the cumulative drinking amount and the cumulative smoking amount was collected with a questionnaire. The optimum applied amount of dansyl-Cl, the optimum reaction temperature and time, the recoveries and the optimum pH of the eluent and buffer were determined.4-Hyp from human urine was derivatized with dansyl-Cl (dimethylamino-naphthalene-1-sulfonyl chloride) after removing the a-amino acid by a treatment with phthalic dicarboxaldehyde (OPA) and cleaned with Bond Elut C18 column. The 4-Hyp derivatives were separated on a reversed phase column by gradient elution with a phosphate buffer (5 mmol, pH 8.0) and acetonitrile, and detected by fluorescence measurements at 340 nm (excitation) and 538 nm (emission). Results : The detection limit for the urinary free 4-Hyp was $0.364{\mu}mol/l$. The recovery rate of 4-Hyp was 99.7%, and the effective pH of the phosphate buffer and borate buffer were 3.0 and 8.0, respectively. From statistical analysis, age, drinking and smoking did not affect the urinary free 4-Hyp in both the controls and workers. The range of urinary 4-Hyp in the controls, pre-shift, and post-shift workers were 0.33-16.44, N.D-49.06, and $0.32-56.27{\mu}mol/l$. From the pared-sample t-test, the urinary 4-Hyp levels in post-shift workers ($11.82{\pm}6.73\;nmmol/mg\;Cre$) were 2-fold higher than in pre-shift workers ($5.36{\pm}5.53\;nmol;/mg\;Cre$) and controls ($4.91{\pm}4.89\;nmol;/mg\;Cre$). Conclusions : This method was developed with high sensitivity, accuracy, and precision. The present method was effectively applied to analyze the urinary free 4-Hyp in both controls and workers.

Effect of SPR Chip with Nano-structured Surface on Sensitivity in SPR Sensor (나노형상을 가진 표면플라즈몬공명 센서칩의 감도 개선 효과)

  • Cho, Yong-Jin;Kim, Chul-Jin;Kim, Namsoo;Kim, Chong-Tai;Kim, Tae-Eun;Kim, Hyo-Sop;Kim, Jae-Ho
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.49-53
    • /
    • 2010
  • Surface plasmon resonance (SPR) which is utilized in thin film refractometry-based sensors has been concerned on measurement of physical, chemical and biological quantities because of its high sensitivity and label-free feature. In this paper, an application of SPR to detection of alcohol content in wine and liquor was investigated. The result showed that SPR sensor had high potential to evaluate alcohol content. Nevertheless, food industry may need SPR sensor with higher sensitivity. Herein, we introduced a nano-technique into fabrication of SPR chip to enhance SPR sensitivity. Using Langmuir-Blodgett (LB) method, gold film with nano-structured surface was devised. In order to make a new SPR chip, firstly, a single layer of nano-scaled silica particles adhered to plain surface of gold film. Thereafter, gold was deposited on the template by an e-beam evaporator. Finally, the nano-structured surface with basin-like shape was obtained after removing the silica particles by sonication. In this study, two types of silica particles, or 130 nm and 300 nm, were used as template beads and sensitivity of the new SPR chip was tested with ethanol solution, respectively. Applying the new developed SPR sensor to a model food of alcoholic beverage, the sensitivity showed improvement of 95% over the conventional one.