• Title/Summary/Keyword: Chemical Detection

Search Result 1,716, Processing Time 0.027 seconds

Leaching Characteristics and Potential Impact Assessment of Pollutants from Field Test Cells with Coal Bottom Ash as Fill Materials for Recycling (석탄 바닥재 메움재 재활용을 위한 Field Test Cells로부터 오염물질 배출 특성 및 잠재적 영향 평가)

  • Jang, Yong-Chul;Lee, Sungwoo;Kang, Heeseok;Lee, Seunghun
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.2
    • /
    • pp.135-145
    • /
    • 2013
  • The recycling of coal bottom ash generated from coal power plants in Korea has been limited due to heterogenous characteristics of the materials. The most common management option for the ash is disposal in landfills (i.e. ash pond) near ocean. The presence of large coarse and fine materials in the ash has prompted the desire to beneficially use it in an application such as fill materials. Prior to reuse application as fill materials, the potential risks to the environment must be assessed with regard to the impacts. In this study, a total of nine test cells with bottom ash samples collected from pretreated bottom ash piles and coal ash pond in a coal-fired power plant were constructed and operated under the field conditions to evaluate the leachability over a period of 210 days. Leachate samples from the test cells were analyzed for a number of chemical parameters (e.g., pH, salinity, electrical conductance, anions, and metals). The concentrations of chemicals detected in the leachate were compared to appropriate standards (drinking water standard) with dilution attenuation factor, if possible, to assess potential leaching risks to the surrounding area. Based on the leachate analysis, most of the samples showed slightly high pH values for the coal ash contained test cells, and contained several ions such as sodium, potassium, calcium, magnesium, chloride, sulfate, and nitrate in relatively large quantities. Three elements (aluminum, boron, and barium) were commonly detected above their respective detection limits in a number of leachate samples, especially in the early leaching period of time. The results of the test cell study indicate that the pollutants in the leachate from the coal ash test cells were not of a major concern in terms of leaching risk to surface water and groundwater under field conditions as fill materials. However, care must be taken in extending these results to actual applications because the results presented in this study are based on the limited field test settings and time frame. Structural characteristics and analysis for coal bottom ash may be warranted to apply the materials to actual field conditions.

Method comparison for analyzing formaldehyde in marker pen ink (마킹펜 잉크 내 폼알데하이드 분석법 비교)

  • Park, Kwang Seo;Kim, Yong Shin;Choe, Eun Kyung
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.115-124
    • /
    • 2020
  • Marker pens belong to school things that are controlled by the regulation system called safety confirmation under special act on the safety of products for children with the formaldehyde criteria of 20 mg/kg. With nine marker pens available commercially, formaldehyde in marker pen ink was analyzed by present test standard where marking on a fabric swatch with a pen and extracting the swatch in water and derivatization with Nash reagent followed by UV/Vis spectrophotometeric measurement (Nash-UV/Vis method), giving not detected results or a false positive result in case of a colored water extract. However, the contents of formaldehyde in ink of nine marker pens were determinded to range between 3.2 ~ 93.2 mg/kg with three results above the safety criteria of 20 mg/kg by HPLC/DAD measurements on DNPH derivatives of formaldehyde (DNPH-HPLC/DAD method) in ink dissolved directly in water using an ultrasonic bath. Therefore, the DNPH-HPLC/DAD method with the extraction of ultrasonic dissolving ink in water is proposed as a proper method for analyzing formaldehyde in ink. The proposed method has advantages of lower detection limit and accuracy with colored extracts as well as a simple and fast extraction. The accuracy and precision of this method was estimated to be 90.1 ~ 105.4 % and 0.6 ~ 3.3 %, respectively by spiking tests in the ranges of 20 mg/kg and 40 mg/kg using matrixes such as highlighter pen ink, board marker ink, chalk marker pen ink and painter marker ink.

Evaluation of the Genetic Toxicity of Synthetic Chemicals (XI) - a Synthetic Sulfonylurea Herbicide, Pyrazosulfuron-ethyl-

  • Ryu, Jae-Chun;Kim, Eun-Young;Kim, Young-Seok;Yun, Hye-Jung
    • Environmental Mutagens and Carcinogens
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • To validate and to estimate the chemical hazard playa very important role to environment and human health. The detection of many synthetic chemicals including agrochemicals that may pose a genetic hazard in our environment is of great concern at present. Since these substances are not limited to the original products, and enter the environment, they have become widespread environmental pollutants, thus leading to a variety of chemicals that possibly threaten the public health. Pyrazosulfuron-ethyl [Ethyl-5-(4,6-dimethoxypyrimidin-2-ylcarbamoylsulfamoyl)-1-methylpyrazole-4-carboxylate, $C_{14}H_{18}N{6}O_{7}S,$ M.W. =414.39, CAS No. 93697-74-6], is one of well known rice herbicide belong in the sulfonyl urea group. To clarify the genotoxicity of this agrochemical, Ames bacterial reversion assay, in vitro chromosomal aberration assay with Chinese hamster lung (CHL) fibroblast and bone marrow micronucleus assay in mice were subjected. In Ames assay, although pyrazosulfuron-ethyl revealed cytotoxic at 5,000-140 $\mug/plate$ in Salmonella typhimurium TA100, no dose-dependent mutagenic potential in 4.4~70 $\mug/plate$ of S. typhimurium TA 98, TA 100, TA1535 and TA 1537 both in the absence and presence of S-9 metabolic activation system was observed. Using CHL fibroblasts, the 50% cell growth inhibition concentration $(IC_{50})$ of pyrazosulfuron-ethyl was determined as 1,243 $\mug/mL,$ and no chromosomal aberration was observed both in the absence and presence of S-9 mixture in the concentration range of 311-1,243 $\mug/mL.$ And also, in vivo micronucleus assay using mouse bone marrow, pyrazosulfuron-ethyl revealed no remarkable induction of MNPCE (micronucleated polychromatic erythrocytes/1000 polychromatic erythrocytes) in the dose range of 625-2,500 mg/kg body weight when administered orally. Consequently, Ames bacterial gene mutation with Salmonella typhimurium, in vitro chromosome aberration with mammalian cells and in vivo bone marrow micronucleus assay revealed no clastogenic potential of pyrazosulfuron-ethyl in this study.

  • PDF

The Study of Near-field Scanning Microwave Microscope for the Nondestructive Detection System (비파괴 측정을 위한 근접장 마이크로파 현미경 연구)

  • Kim, Joo-Young;Kim, Song-Hui;Yoo, Hyun-Jun;Yang, Jong-Il;Yoo, Hyung-Keun;Yu, Kyong-Son;Kim, Seung-Wan;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.508-517
    • /
    • 2004
  • We described a near-field scanning microwave microscope which uses a high-quality dielectric resonator with a tunable screw. The operating frequency is f=4.5 5GHz. The probe tip is mounted in a cylindrical resonant cavity coupled to a dielectric resonator We developed a hybrid tip combining a reduced length of the tapered part with a small apex. In order to understand the function of the probe, we fabricated three different tips using a conventional chemical etching technique and observed three different NSMM images for patterened Cr films on glass substrates. We measured the reflection coefficient of different metal thin film samples with the same thickness of 300m and compared with theoretical impedance respectly. By tuning the tunable screw coming through the top cover, we could improve sensitivity, signal-to-noise ratio, and spatial resolution to better than $1{\mu}m$. To demonstrate the ability of local microwave characterization, the surface resistance of metallic thin films has been mapped.

A Study on Occupational Hydrofluoric Acid Burns in a Hydrofluoric Acid Manufacturing Factory (불산제조업체에서 발생한 불산화상에 관한 조사연구)

  • Lim, Hyun-Sul;Cheong, Hae-Kwan;Kim, Ji-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.4 s.44
    • /
    • pp.587-598
    • /
    • 1993
  • Hydrofluoric acid is one of the strongest irritating, corrosive and poisonous inorganic chemicals. Hydrofluoric acid burns are occurring with ever-increasing frequency due to the wide use of this acid in industries. Hydrofluoric acid burns are characterized by severe progressive tissue destruction and excruciating pain due to the unique properties of the freely dissolvable fluoride ion. The authors reviewed medical records of 32 cases (36 spells) of hydrofluoric acid burns which occurred in a hydrofluoric acid manufacturing factory from Sep. 1, 1990 to June 30, 1993. The results are as follows; 1. Eleven measurements of air concentrations of hydrofluoric acid by detection tube method from 1990 to 1992 were all below TLV (Department of Labor, R.O. K). 2. There were 19 cases (22 spells) of hydrofluoric acid burns which occurred during the study period among regular employees. The overall incidence density of hydrofluoric acid was 17.8 cases (20.6 spells) per 100 person-year. Incidence density was 19.0 cases (22.0 spells) per 100 person-year among male workers and there were no female cases. Incidence density was 32.9 cases (38.3 spells) per 100 person-year among production workers and 1.9 cases (1.9 spells) per 100 person-years among management workers with the difference being statistically significant (P<0.01). 3. Of 32 cases (36 spells) of hydrofluoric acid burns among workers who were regularly employed or temporarily employed, 26 spells (81.2%) were between age 20 to 39. In 15 spells(41.7%) burns occurred between 12:00 and 17:59 with 16 spells(44.3%) having arrived at hospital within 2 hours after the accident. 4. Of 36 spells, the main cause of hydrofluoric acid burns were by splashes (8 spells, 22.2 %). The most frequent site of burns were fingers and pain was the most frequent symptom. Thirty spells (83.3%) of the hydrofluoric acid burns were treated with local injection of antidote (calcium gluconate). Complete recovery without scarring were observed in most of the cases (34 out of 36 cases, 94.4%). The study results suggest that to prevent hydrofluoric acid burns, environmental control and the wearing of hydrofluoric acid resistant protective clothes and gloves are important. It is also stressed that establishment of an emergency management and a transfer system for hydrofluoric acid burn victims is necessary.

  • PDF

Surface Treatments of Bronze Mirrors Excavated from Korean Peninsula (한반도 출토 청동거울의 표면처리 기법에 관한 연구)

  • Jeon, Ik-Hwan;Lee, Jae-Sung;Baek, Ji-Hye;Park, Jang-Sik
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.87-98
    • /
    • 2008
  • Microstructures and chemical compositions of 24 bronze mirrors recovered from the Korean peninsula were examined using the scanning electron microscope equipped with the energy dispersive spectrometer in an effort to characterize the treatments applied on their surface. Their provenance and chronology are mostly unspecified except for two objects from a Koryo burial site. In antiquity the surface of bronze mirrors was frequently finished by mere polishing when their tin content was high enough to guarantee the required reflectivity. In many cases, however, their surface was given a special treatment. The most typical treatment was to coat the surface with tin in two different processes referred to as wipe-tinning and amalgam-tinning. In wipe-tinning only tin was used, but in amalgam-tinning tin and mercury were used together. The surface was often coated with mercury in a process known as mercury-polishing. The present mirrors showed that all these techniques were in fact practiced, not only on the reflective surface but, in some cases, on the decorative surface. The detection of mercury played a crucial role in the assessment of a specific technique applied in each mirror. Mercury often remained in the substrate in the form of sulfide and thereby allowed the method of surface treatment to be estimated even when the coated layer was completely lost. The future study is expected to uncover the regional and temporal variation of the surface treatments to the better understanding of bronze mirrors with respect to provenance and chronology.

  • PDF

Comparison of In-Phase and Opposed-Phase FMPSPGR Images in Breath-hold T1-weighted MR IMaging of Liver (호흡정지 T1 강조 간 자기공명영상에서 동위상 역위상 FMPSPGR 영상의 비교)

  • 김명진;김만득;정재준;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.142-147
    • /
    • 1997
  • Purpose: To compare the effectiveness of the in-phase (IP) sequence and the opposed-phase (Op) sequence in the detection of focal hepatic lesions in the single breath-hold hepatic MR imaging with fast gradient T1-weighted pulse sequences. Materials and Methods: IP and OP T1-weighted breath-hold imaging was performed using fast gradient echo sequences in 45 patients referred for known focal hepatic lesions, in which 78 lesions were detected. Three blind readers independently reviewed the images for lesion detectability. The signal-to-noise ratio (SNR) of the liver, the lesion-to-liver contrast-to-noise ratio (CNR) and the liver-to-spleen CNR were also compared. A consensus was reached by three readers to determine which sequence is better in image quality. Results: On OP images, 61(78%), 61(78%), and 63(89%) lesions were correctly identified for reader 1, 2 and 3, respectively. On IP images, 66(85%), 65(83%), and 65(93%) lesions were detected for each reader, respectively. When two image sets were combined, 71(91 %), 69(88 %), and 76(97%) lesions respectively were detected for each reader. In cases of hepatocellular carcinoma, liver-to-Iesion CNR was greater on the OP images(p (0.05), but in other lesions significant difference was not demonstrated. Liver-to-spleen CNR was higher on OP images(p ( 0.1), but the SNR of the liver was higher on the IP images. Conclusion: Use of both IP and OP imaging can be helpful to avoid erroneous missing of some focal hepatic lesions.

  • PDF

Isolation and Characterization of Actinomycete Strain BK185 Possessing Antifungal Activity against Ginseng Root Rot Pathogens (인삼 뿌리썩음병균에 항균활성이 있는 방선균 BK185의 분리 및 특성)

  • Kim, Byung-Yong;Bae, Mun-Hyung;Ahn, Jae-Hyung;Weon, Hang-Yeon;Kim, Sung-Il;Kim, Wan-Kyu;Oh, Dong-Chan;Song, Jaekyeong
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.396-403
    • /
    • 2014
  • Ginseng (Panax ginseng C. A. Meyer) is an economically valuable pharmaceutical crop in Korea. In order to find promising biocontrol agents for soil-borne fungal pathogens which infect ginseng roots, we have isolated actinomycete, BK185 from soil. The isolate was investigated for the antifungal activity against to ginseng rot pathogens prior to testing genetic and chemical properties. The strain was identified as Streptomyces sp. using phylogenetic analysis based on 16S rRNA gene sequence. The most closely related species was S. sporoclivatus and S. geldanamycininus with high similarities (>99%). The isolate, BK185 showed positive reaction for PCR detection targeting biosynthetic gene clusters of PKS (Type-I polyketide synthase) and NRPS (Non-ribosomal polypeptide synthetase) genes. Major metabolite from the BK185 was analyzed by The LC/MS and identified to geldamycin, which was known to contained broad antibacterial, antifungal or anticancer activities. The results provide evidences that the strain, BK185 can be promising biocontrol agent for ginseng organic farming.

Succession of Bacterial Populations in Cattle Manure Compost as Determined by Fluorescent In Situ Hybridization (우분 퇴비화에서의 Fluorescent In Situ Hybridization법에 의한 세균군집의 천이)

  • Lee, Young-Ok;Jo, Ik-Hwan;Kim, Kil-Woong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.146-153
    • /
    • 2000
  • To elucidate succession of bacterial populations, especially nitrifying bacteria during the composting of cattle manure with apple pomace, fluorescent in situ hybridization(FISH) using rRNA targeted oligonucleotide probes were applied. The density of ammonia-oxidizing bacteria was ranged from $3,3{\times}10^6cells/g$ dw to $13,4{\times}10^6cells/g$ dw with the peak value after 26 composting days whereas that of nitrite-oxidizing bacteria varied between $6.0{\times}10^6cells/g$ dw and $17.2{\times}10^6cells/g$ dw with the peak value after 7 composting days. And the tendency that the numbers of nitrite-oxidizing bacteria were higher than those of ammonia-oxidizing bacteria, and the peak-time of their densities were the same as that of data determined by the ratio of ammonia-oxidizing bacteria and nitrite-oxidizing bacteria to eubacteria. The peak of ammonia-oxidizing bacteria followed the peak of nitrite-oxidizing bacteria, at the late phase of composting process could be probably caused by the depletion of volatile ammonia of composting materials. Besides these results indicate that FISH method is a useful tool for detection of slow growing nitrifying bacteria.

  • PDF

Determination of Eu(III) by Fluorescence Spectrometry using Fiber Optic Sensor (광섬유센서를 이용한 Eu(III)의 형광분광법적 정량)

  • Lee, Sang Hak;Lee, Yoon Hee;Yang, Seung Tae;Choi, Sang Seob
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.409-412
    • /
    • 1998
  • The analytical method to determine europium(III) ion in aqueous solution by fluorescence spectroscopy based upon the conformational change of calmodulin in the presence of the analyte has been studied. The fiber optic chemical sensor used in this study was constructed by entrapping a fluorescein-labeled calmodulin solution, EGTA, buffer solution at the common end of a bifurcated fiber optic bundle by means of a dialysis membrane. The calibration curve to determine europium(III) ion was obtained when concentration of calmodulin, concentration of EGTA, Tris-HCl buffer solution, pH, excitation wavelength and fluorescence wavelength were $5.0{\times}10^{-5}M$, 0.50 mM, 5.0 mM, 7.0, 495 nm and 520 nm, respectively. The detection limit was $1.0{\times}10^{-11}M$ and the working range of the calibration curve for the sensor was $1.0{\times}10^{-11}M{\sim}1.0{\times}10^{-9}M$. The response time was 15 minutes. For the determination of europium(III) ion by the present method, $Na^+$ and $K^+$ ions did not interfere but $Ca^{2+}$ ion seriously interfered.

  • PDF