• 제목/요약/키워드: Check-Valve

검색결과 210건 처리시간 0.03초

SEOUL-10 모드에서 바이오디젤유 (5%) 적용시 커먼레일 디젤기관의 배기배출물 및 내구 특성 (Characteristics of Durability and Emission with Biodiesel Fuel (5%) in a Common Rail Direct Injection Diesel Engine at SEOUL-10 Mode)

  • 최승훈;오영택;김건회
    • Journal of Biosystems Engineering
    • /
    • 제32권2호
    • /
    • pp.97-101
    • /
    • 2007
  • A CRDI diesel engine used to commercial vehicle was fueled with diesel fuel and 5% biodiesel blended fuel (BDF 5%) and tested at the Seoul-10 mode for 150 hours. Engine dynamometer testing was completed at regularly scheduled intervals to monitor the engine performance and exhaust emissions. To check the engine parts (valve, injector), the engine was inspected after 150 hours running test. It was concluded that there was no unusual deterioration of the engine, or the changes in engine power (below 2.6%), smoke (below 6.2%), NOx (below 2%) and durability characteristics in spite of operation of 150 hours run with BDF 5%. The difference of kinetic viscosity for engine oil (before and after durability testing) was below 0.36%

LP가스연료 액상공급시스템 특성연구 (An investigation of LPG fuel supply method for Liquid phase LPG injection system)

  • 김창업;오승묵;최수진;강건용
    • 한국분무공학회지
    • /
    • 제9권2호
    • /
    • pp.18-23
    • /
    • 2004
  • An experimental studies of conventional gasoline fuel pump were carried out to obtain fundamental data fur liquid phase LPG injection(LPLi) system. A regenerative type and a roller-vane type of pumps were investigated in various operational condition. The experiments were performed to obtain flow rate of LPG fuel as a function of pressure differences and temperatures. The regenerative pump had too low flow rate at some experimental conditions to use this pump system for LPLi fuel supply system. On the other hand, the roller-vane type pump can be applied to the system only if its check valve is modified. Cavitation might occur in this system which can result in system noise, flow rate variation, and pump durability problem. To solve these problems the system is needed to increase $NPSH_{re}$(required net positive suction head).

  • PDF

원자로 비상 냉각재 누설에 의한 열성층의 비정상 특성에 관한 연구 (Study of Thermal Stratification into Leaking Flow in the Nuclear Power Plant, Emergency Core Coolant System)

  • 한성민;최영돈;박민수
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.202-210
    • /
    • 2006
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can be occurred due to coolant leaking in the check valve. The thermal stratification produces excessive thormal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, when the turbulence penetration occurs in the branch pipe, the maximum temperature differences of fluid at the pipe cross-sections of the T-branch with thermal stratification are examine.

차량 안정성 제어 시스템의 모듈레이터 성능개선 및 단순화에 관한 연구 (A Study on the Performance Improvement and Simplification of the Modulator for Vehicle Stability Control System)

  • 이종찬;송창섭
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.84-93
    • /
    • 2004
  • This study carries out the performance improvement and simplification of hydraulic modulator that plays an important role in vehicle stability control systems. The mathematical models for each component of a modulator, such as pump, wheel cylinder, check and solenoid valve, accumulator, damper are derived in detail. All the mathematical models are combined to form a modulator system and implemented through a computer program, which can be controlled by a user friendly GUI. To verity the simulation, comparison between simulation and experiments has been made. After the verification of the validity of the simulation, the effects of the design parameters of the modulator on the wheel cylinder pressure is investigated. The results show that the modulator without MPA has advantage in early time pressure rise rate, and it can be simplified.

공압 실린더 액츄에이터 위치제어 (Position Control of a Pneumatic Cylinder Actuator using PLC and Proximity Sensors)

  • 권순홍;최원식;정성원;박종민;권순구;서정덕
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.50-55
    • /
    • 2011
  • The fluid power products are widely used in current industrial area such as automation of products and equipment assembly, high-tech machine tool, aircraft, train, and etc. As the development of industry is in progress, the development of the fluid power products is demanding and it is required in every industrial area. This research proposed a pneumatic system to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the valve system. The pneumatic system consisted of a combination of pneumatic actuator, four two-port valves, two three-port valves, two pressure valve, a check valve, two proximity sensors, and a program logic controller (PLC). The position controller is based on the PLC connected with the proximity sensors. The maximum air pressure applied for tests was $49.05N/cm^2$ and the displacement accuracy of a stroke was measured using a dial gauge. The supply- and discharge-side of air pressure and the length of the stroke of the pneumatic cylinder were varied The test of the position control of the pneumatic cylinder was carried out 50 times at each supply- and discharge-side air pressure of 24.53/34.34, 29.43/39.24, 34.34/44.15, and $39.24/49.05N/cm^2$ and replicated three times. The accuracy of the displacement of the pneumatic cylinder stroke increased as the supply- and discharge-side of air pressure increased with the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with the fixed supply- and discharge-side of air pressure of the pneumatic cylinder as 34.34 and $44.15N/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder was obtained at the supplyand discharge-side of air pressure of 39.24 and $49.05N/cm^2$, respectively, and strokes of 170 and 190mm.

초고압 용적형 펌프의 체절운전시스템 개발에 관한 연구 (A Study on Development of Shutoff Operating System of Ultra-High Pressure Positive Displacement Pump)

  • 민세홍;김호철;성기찬
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.106-113
    • /
    • 2016
  • 초고압 용적형 펌프는 로터의 회전에 의한 주기적인 용적의 변화를 이용하는 펌프로 고압, 고유량을 동시에 만족하며 로터의 저속 및 고속 회전에 따라 변화 없이 일정하게 상대적으로 높은 펌프 효율을 유지할 수 있는 장점을 가진다. 많이 사용되고 있는 원심펌프와는 달리 별도의 진공펌프가 없이도 자흡 성능을 가지고 있으며, 비교적 단순한 구조로 인하여 경량화, 소형화가 가능한 특성을 자기고 있다. 유체를 높은 압력으로 이송할 수 있으며, 압력의 변동에 따라 유량의 변동이 적은 정량 토출이 가능하다. 이러한 용적형 펌프를 사용하는 이유는 흡입된 유체가 유량의 변화 없이 토출되는 장점이 있기 때문이다. 본 연구에서는 유량의 변화가 없다는 장점이 있는 용적형 펌프의 체절시스템을 개발하여 펌프의 고압 운전시의 안전성을 확보하고자 하였다. 체절시스템은 컨트롤러 프로그램, 전자클러치, 릴리프밸브의 3가지로 이루어져, 한 가지 시스템이 작동하지 않아도 다른 시스템이 작동하는 시스템으로 이루어져 있다. 컨트롤러 프로그램과 전자 클러치의 작동을 확인하기 위한 과속도 시험과 릴리프 밸브의 유체유동해석, venting 실험을 통해 현재 개발한 초고압 용적형 펌프의 체절시스템이 작동됨을 확인하였다.

양계 급수용 구면 피스톤 니플의 성능 평가 (Evaluation of Sphere Faced Type Piston Nipple for Water Feed of Poultry)

  • 김기선
    • 한국산학기술학회논문지
    • /
    • 제8권5호
    • /
    • pp.961-967
    • /
    • 2007
  • 양계 농장의 자동화 시설 중 닭에 물을 공급하는 자동 급수 장치는 닭 사육을 위한 가장 중요한 시설중의 하나이다. 이 장치 부품 중 급수 니플은 닭이 직접 물을 먹는 장치이며 그 내부에 체크 밸브가 있어 물 공급 시에는 열리고 물을 먹지 않을 경우는 닫히게 된다. 니플의 종류는 피스톤 니플과 볼 니플로 나누워지며 볼 니플은 니플 스틱의 운동이 자유롭게 되어 낙수의 차단이 잘되는 장점이 있으나 복잡한 구조를 갔고 있는 단점이 있다. 이에 반하여 피스톤 니플은 구조가 간단한 장점이 있는 반면에 대부분 상하운동만 가능한 단점이 있다 최근에 이를 보완하기 위하여 피스톤 니플에 밸브 시트면을 구 형태로 제작하여 피스톤 형식이면서 자유로운 운동이 가능 하도록 한 구조(이하 : 구면 피스톤 니플)가 개발 되었다. 본 실험에서는 최근 관심을 갖게된 구면 피스톤 니플에 대한 성능 평가를 수행하였으며 그 결과를 국내외 기존 제품인 볼 니플 및 피스톤 니플과 성능을 실험적으로 비교 분석하였다. 그 결과 구면 피스톤 니플의 성능은 기존 피스톤 니플 보다는 좋은 결과를 얻었으며 볼 니플과는 유사한 성능임을 확인하였다.

  • PDF

주방 가스레인지 빌트인 방식에서 가스 누출검사를 위한 IoT 검사 시스템 개발에 관한 연구 (A Study on the Development of IoT Inspection System for Gas Leakage Inspection in Kitchen Gas Range Built-in Method)

  • 강대국;최영규
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권4호
    • /
    • pp.283-290
    • /
    • 2022
  • 본 연구에서는 가정 내의 가스 밸브에 장착되는 가스 타이머와 ESP-01 와이파이 모듈을 활용하여 서버와 연동되는 IoT 검사 시스템을 개발하였다. 가스 누출 IoT 검사 시스템의 서버 환경은 APM(Apache, PHP, MySQL)을 설치하여 세대별 가스 압력 데이터를 수집하여 누출 체크를 할 수 있도록 하였다. 가스 누출 IoT 검사 시스템 제어를 위해 앱 인벤터를 활용하여 가스 누출 체크 값을 실시간으로 관리를 할 수 있도록 하였다. 또한 모바일 앱으로 회원 관리 및 WiFi 설정, 누출 체크 값 등을 확인할 수 있도록 사용자의 편의성을 높였다. 지역별 가입자 관리를 하기 위해서 관리자 모드로 로그인하여 사용자 목록 확인을 하여 누출 검사 여부와 결과에 대한 안내를 할 수 있도록 하였다. 또한 사용자가 가스누출 체크 버튼을 누르면 자동으로 압력을 체크하여 서버에 측정값이 저장되고 가스 누출 발생 시에는 경보 및 수리 후 누출 체크를 하여 정상이면 사용할 수 있도록 하였다. 또한 회원의 중복 가입을 막기 위해 MAC 주소를 기반으로 회원 관리를 할 수 있도록 하였다.

자동차부품 벤처기업 스마트공장 및 모니터링 시스템 구현 사례연구 (A Case Study on Smart Plant and Monitoring System Implementation of Venture Company for Auto Parts)

  • 한재훈;이덕수;박노국
    • 벤처창업연구
    • /
    • 제12권5호
    • /
    • pp.29-37
    • /
    • 2017
  • 본 연구에서는 설비자동화를 통한 생산성 향상 및 제품품질, 공장 환경 개선, 설비 유지 관리 상태 및 제품 불량 유무 확인 등 제품품질관리를 위해 공장현장내에서 실시간 모니터링을 실시하고, 현장 작업시 발생하는 각종 분진을 제거하고, 작업자 개인 환경을 보호하기 위한 목적으로 스마트 공장을 구축하는 사례를 연구하여 제시하였다. 해당기업은 지방에 소재하고 있는 자동차부품기업이며 주요 연구내용은 스마트공장에 필요한 오일필터 클립핑 자동화 및 모니터링 시스템 개발이다. 스마트 공장 오일 필터 클립핑 자동화는 전기에어부품, 솔레노이드밸브 및 기타와 장비부품 가공 제작 과정으로 구분하여 구현하였으며, 스마트 공장 품질검사 모니터링 시스템은 서버PC 및 S/W, 클라이언트 S/W 및 현황 디스플레이 모니터, 운영자 PC, 운영프로그램, 입력단말기 어플리케이션 등으로 구분하여 실제적으로 구현하였다. 본 연구자료는 스마트공장을 추진하는 자동차부품 벤처기업에게 매우 유용한 자료가 될 것으로 보여진다.

  • PDF

화재폭발지수 개선에 대한 사례 연구 (Case Study on Advanced Fire and Explosion Index)

  • 나건문;서재민;이미정;백종배
    • 한국안전학회지
    • /
    • 제35권6호
    • /
    • pp.78-84
    • /
    • 2020
  • The F&EI technique is one of the risk assessments with many advantages. It can save time and effort compared to quantitative risk assessment (QRA). By using the evaluation result of this technique, it is possible to check the effectiveness of the investment cost. In addition, a relative risk ranking can be created and used to establish the facility management cycle and to prioritize investment. However, evaluating the target process can be evaluated more than the actual risk since the LCCF, a loss prevention measure, is too limited. In addition, calculating premiums via this method can result in excessive premiums, making it difficult to evaluate the risk precisely. Therefore, new safety guard was added to the LCCF of the F&EI risk assessment with reference to HAZOP and LOPA techniques. Newly added LCCFs are Deflagration arrester, Check valve, SIS, and Vacuum beaker, etc. As a case study, F&EI risk assessment was performed on Acetone storage tank of a API (Active pharmaceutical ingredient) plant to compare actual MPPD. The estimated loss amount was 592,558$ for the existing technique and 563,571$ for the improved technique, which was reduced by about 5% compared to the previous one.This proved that a more precise evaluation is possible and that the efforts for safety at the workplace are reflected in the evaluation results.