• 제목/요약/키워드: Charged particle therapy

검색결과 18건 처리시간 0.03초

A Scheduling System for the Patient Treatment on a Heavy-ion Radiotherapy

  • Toyama, Hinako;Shibayama, Kouichi;Kanatsu, Syusuke;Kuroiwa, Toshitaka;Watanabe, Hideo;Wakaisami, Mitsuji;Tsuji, Hiroshi;Endo, Masahiro;Tsujii, Hirohiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.177-179
    • /
    • 2002
  • We have developed a scheduling system for heavy ion radiotherapy considering the condition of three treatment rooms and treatment planning for each patient. This system consists of a database (patient information, treatment method and machine schedule), a schedule for radiotherapy and WEB server. All operation of this system, such as data input, to change and to view the schedule, are performed by using a WEB browser. In order to protect personal information for the patients, access privilege to each information are limited by according to the occupational category. This system is connected with a hospital central information management system (AMIDAS) and an irradiation-managing computer for the heavy ion radiotherapy. A basic information for the patient is got from AMIDAS and the daily schedule sends to the treatment control computer at each treatment room through the irradiation-managing computer every morning. The daily, weekly, monthly schedules in the treatment room and the treatment condition of each patient are shared on the WEB browser with the all participants of the heavy ion therapy. This system could be useful to save a time to generate a treatment schedule and to inform us the most up-to-date treatment schedule and the related information at the same time.

  • PDF

Profile and Dose Distribution for Therapeutic Heavy Ion Beams

  • Sasaki, Hitomi;Komori, Masataka;Kohno, Toshiyuki;Kanai, Tatsuaki;Hirai, Masaaki;Urakabe, Eriko;Nishio, Teiji
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.211-213
    • /
    • 2002
  • The purpose of this work is acquiring some parameters of therapeutic heavy ion beams after penetrating a thick target. The experiments were performed using a pencil-like $\^$12/C beam of about 3 mm in diameter from NIRS-HIMAC, and the data were taken at several points of the target thickness for $\^$12/C beam of 290 MeV/u and 400 MeV/u. By the simultaneous measurements using some detectors, the atomic number of each fragment particle was identified, and the beam profile, the dose distribution and the LET spectrum for each element were derived.

  • PDF

An Analysis on Treatment Schedule of Carbon Ion Therapy to Early Stage Lung Cancer

  • Sakata, Suoh;Miyamoto, Tadaaki;Tujii, Hirohiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.174-176
    • /
    • 2002
  • A total of 134 patients with stage 1 of non-small cell lung cancer treated by carbon ion beam of HIMAC NIRS were investigated for control rate and delivered dose. The delivered dose of every patient was converted to biological effective dose (BED) of LQ model using fraction number, dose per fraction and alpha beta ratio which shows the maximum correlation between BED and tumor control. The BED of every patient was classified to establish a BED response curve for control. Assuming fraction numbers, dose response curves were introduced from BED response curve. The total doses to realize several control rates were obtained for the treatment of small fraction number.

  • PDF

Basics of particle therapy I: physics

  • Park, Seo-Hyun;Kang, Jin-Oh
    • Radiation Oncology Journal
    • /
    • 제29권3호
    • /
    • pp.135-146
    • /
    • 2011
  • With the advance of modern radiation therapy technique, radiation dose conformation and dose distribution have improved dramatically. However, the progress does not completely fulfi ll the goal of cancer treatment such as improved local control or survival. The discordances with the clinical results are from the biophysical nature of photon, which is the main source of radiation therapy in current field, with the lower linear energy transfer to the target. As part of a natural progression, there recently has been a resurgence of interest in particle therapy, specifically using heavy charged particles, because these kinds of radiations serve theoretical advantages in both biological and physical aspects. The Korean government is to set up a heavy charged particle facility in Korea Institute of Radiological & Medical Sciences. This review introduces some of the elementary physics of the various particles for the sake of Korean radiation oncologists' interest.

Proton Beam Dosimetry Intercomparison

  • Fukumura, Akifumi;Kanai, Tatsuaki;Kanematsu, Nobuyuki;Yusa, Ken;Maruhashi, Akira;Nohtomi, Akihiro;Nishio, Teiji;Shimbo, Munefumi;Akagi, Takashi;Yanou, Toshihiro;Fukuda, Shigekazu;Hasegawa, Takashi;Kusano, Yohsuke;Masuda, Yasutaka
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.252-254
    • /
    • 2002
  • A new protocol for dosimetry in external beam radiotherapy is published by the Japan Society of Medical Physics (JSMP) in 2002. The protocol deals with proton and heavy ion beams as well as photon and electron beams, in accordance with IAEA Technical Report Series No. 398. To establish inter-institutional uniformity in proton beam dosimetry, an intercomparison program was carried out with the new protocol. The absorbed doses are measured with different cylindrical ionization chambers in a water phantom at a position of 30-mm residual range for a proton beam, that had range of 155 mm and a spread out Bragg peak (SOBP) of 60-mm width. As a result, the intercomparison showed that the use of the new protocol would improve the +/- 1.0 % (one standard deviation) and 2.7 % (maximum discrepancy) differences in absorbed doses stated by the participating institutions to +/- 0.3% and 0.9 %, respectively. The new protocol will be adopted by all of the participants.

  • PDF

중하전입자 치료의 이론적 배경과 양성자에 대한 몬테칼로 시뮬레이션 (Theoretical Background on Heavy Charged Particle Therapy and Proton Monte Carlo Simulation)

  • 이정옥;이상공;김종일;정동혁;문성록;강정구
    • 한국의학물리학회지:의학물리
    • /
    • 제8권1호
    • /
    • pp.47-52
    • /
    • 1997
  • 양성자나 알파입자와 같은 무거운 하전입자가 매질 속을 진행하는 경우에 매질과 상호작용 하여 일어날 수 있는 물리적인 현상을 알아보기 위하여 몬테칼로 기법을 이용하여 시뮬레이션 하였다. 양성자선의 Bragg peak가 에너지의 증가에 따라 물 속에서 깊어짐을 확인하였다. 이러한 Bragg peak 현상을 방사선치료에 이용할 경우에 표적 조직의 흡수선량이 광자와 전자선에 비하여 국소화 되고 주변조직의 보호효과가 탁월함을 알 수 있었다.

  • PDF

Precise Measurement of Beam Energy and Range with TOF and Counter Telescope System

  • Nanbu, Shuya;Kanai, Tatsuaki;Kohno, Toshiyuki;Ohno, Yumiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.225-227
    • /
    • 2002
  • In order to improve the accuracy of charged-particle radiation therapy, the beam energy was measured precisely using a TOF-system, and the range using a counter telescope system. A Si detector and a Ge detector were used to estimate the range straggling as a $\Delta$E and an E detector, respectively, because they have good energy resolution and the output pulse heights don't depend on the atomic number of detected particles. The results were compared with the theoretical values by a calculation code.

  • PDF

Feasibility study of using triple-energy CT images for improving stopping power estimation

  • Yejin Kim;Jin Sung Kim ;Seungryong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1342-1349
    • /
    • 2023
  • The planning accuracy of charged particle therapy (CPT) is subject to the accuracy of stopping power (SP) estimation. In this study, we propose a method of deriving a pseudo-triple-energy CT (pTECT) that can be achievable in the existing dual-energy CT (DECT) systems for better SP estimation. In order to remove the direct effect of errors in CT values, relative CT values according to three scanning voltage settings were used. CT values of each tissue substitute phantom were measured to show the non-linearity of the values thereby suggesting the absolute difference and ratio of CT values as parameters for SP estimation. Electron density, effective atomic number (EAN), mean excitation energy and SP were calculated based on these parameters. Two of conventional methods were implemented and compared to the proposed pTECT method in terms of residuals, absolute error and root-mean-square-error (RMSE). The proposed method outperformed the comparison methods in every evaluation metrics. Especially, the estimation error for EAN and mean excitation using pTECT were converging to zero. In this proof-of-concept study, we showed the feasibility of using three CT values for accurate SP estimation. Our suggested pTECT method indicates potential clinical utility of spectral CT imaging for CPT planning.