에너지 회수가 가능한 2차전지 충방전시스템용 3상 양방향 AC-DC 컨버터 (Energy Regenerative 3-Phase Bidirectional AC-DC Converter for the Secondary Battery Charge/Discharge System)

  • 임승범;원화영;채수용;서영민;이준영;고종선;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.259-261
    • /
    • 2008
  • The electronic products such as laptop PC, cellular phone, robots and etc. need the DC power source. Recently, the secondary battery is frequently used as the portable DC power source and it needs forming process. In this paper, we proposed the bidirectional converter that the battery can be charged with high power factor and the discharged energy is regenerated into AC power source. In the charging mode, the converter acts as the boost rectifier. And the AC input current is controlled in phase with the AC input voltage. As a result, the power factor is improved nearly to unity. In the discharging mode, the DC power of battery wasted in resistor is regenerated to the AC bus line. Finally, the validity of the proposed bidirectional converter is verified by computer simulations and experimentation.

  • PDF

수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어 (Power Control of a Hoist System Using Supercapacitor)

  • 김상민;유현재;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권11호
    • /
    • pp.561-568
    • /
    • 2005
  • This paper proposes a method that distributes the load power and stores the regenerated energy for a hoist-load system using the supercapacitor, an energy storage device. The crane, which is a representative hoist-load system, operates in two modes. The first is the hoist-up mode in which the load container is lifted up: the maximum power is required at the end of acceleration. The second is the hoist-down mode in which the load container is lifted down; the regenerated energy is wasted by the resistor In this paper, the supercapacitor stores the regenerated energy in the hoist-down operation and supplies the peak power demand in the hoist-up operation. The same structure as the commercially available three-phase inverter is proposed as a bidirectional do-dc converter to charge and discharge the supercapacitor. A power control algorithm is proposed to optimize the load sharing between the generator and the supercapacitor. Using the proposed method, it is effected that the generator size can be cut down to one third of the original one; it leads to the reduction of the fuel consumption, noise and air pollution. Simulation and experimental results verify the effectiveness of the Proposed method.

배터리 충·방전기 시스템에 적용되는 3상 양방향 절연형 인터리브드 DC-DC 컨버터의 병렬운전 (Parallel Operation of Three-Phase Bi-Directional Isolated Interleaved DC-DC Converters for The Battery Charge/Discharge System)

  • 조현식;이재도;차한주
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Recently, parallel operation of dc-dc converters has been widely used in distributed power systems. In this paper, a control method to achieve parallel operation of three-phase bi-directional isolated interleaved dc-dc converters is discussed for the battery charging and discharging system which consists of the 32 battery charger/dischargers and two three-phase bi-directional isolated interleaved dc-dc converters. In the boost mode, the battery energy is delivered to the grid, whereas the grid energy is transferred to the battery in the buck mode operation. The average current sharing control method is employed to obtain an equal conducting of each phase current in the three-phase dc-dc converter. By using the proposed method, the imbalance factor is gratefully reduced from 8 percent to 1 percent. Two 2.5kW three-phase bi-directional dc-dc converter prototype have been built and the proposed method has been verified through experiments.

리튬 배터리를 연계한 100kVA UPQC 개발 및 성능시험 (The Development and Experimental Evaluation of 100kVA Unified Power Quality Conditioner interconnected to the Li-Battery System)

  • 이학주;채우규;박중성;손진만;최은식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.102-110
    • /
    • 2012
  • This paper propose the advanced topology of UPQC, its DC link is connected with Lithium battery, to compensate the momentary interruptions. The proposed system can be operated as UPS mode using the parallel inverter, which control the charge or discharge of battery, in case of the interruption. We dvelop 100kVA UPQC using the proposed topology to rise the power quality and the reliability of Microgrid. We verify its usefulness through voltage compensation test, UPS operation test and etc. using Microgrid test facility.

Regulated Peak Power Tracking (RPPT) System Using Parallel Converter Topologies

  • Ali, Muhammad Saqib;Bae, Hyun-Su;Lee, Seong-Jun;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.870-879
    • /
    • 2011
  • Regulated peak power tracking (RPPT) systems such as the series structure and the series-parallel structures are commonly used in satellite space power systems. However, these structures process the solar array power or the battery power to the load through two cascaded regulators during one orbit cycle, which reduces the energy transfer efficiency. Also the battery charging time is increased due to placement of converter between the battery and the solar array. In this paper a parallel structure has been proposed which can improve the energy transfer efficiency and the battery charging time for satellite space power RPPT systems. An analogue controller is used to control all of the required functions, such as load voltage regulation and solar array stabilization with maximum power point tracking (MPPT). In order to compare the system efficiency and the battery charging efficiency of the proposed structure with those of a series (conventional) structure and a simplified series-parallel structure, simulations are performed and the results are analyzed using a loss analysis model. The proposed structure charges the battery more quickly when compared to the other two structures. Also the efficiency of the proposed structure has been improved under different modes of solar array operation when compared with the other two structures. To verify the system, experiments are carried out under different modes of solar array operation, including PPT charge, battery discharge, and eclipse and trickle charge.

충전전압에 따른 겔형 VRLA전지 양극판의 파손방식 (Failure Mode of the Positive Plate on Charging Voltage in Gel Type Valve Regulated Lead Acid Batteries)

  • 오상협;김명수;이흥락
    • 전기화학회지
    • /
    • 제3권2호
    • /
    • pp.90-95
    • /
    • 2000
  • 겔형 VRLA전지의 파손방식을 조사하기 위하여 $100\%$ 방전심도에서 5시간율 전류로 충방전 수명시험을 하였다. 정전압 충전방식을 사용하여 충전전압을 2.40V와 2.50V로 하였을 때 1,000회 이상의 수명을 나타내었으며, 전지의 무게변화를 측정한 결과 각각 426.4g과 391.2g의 전해액이 감소하였다 2.50V로 충전한 전지가 우수한 수명특성을 나타내었으며, 전해액 손실량이 충전계수와 비례하는 것을 알 수 있었다 1,000회의 충방전 수명시험을 한 전지의 양극기판에는 약 $50{\mu}m$의 부식층이 관찰되었고, 활성물질의 미세구조는 크게 변하였다. 양극판의 파손방식은 활물질 탈락이며, 전해액 손실이 방전용량 감소의 원인인 것을 알 수 있었다.

A Novel Switched Capacitor High Step-up dc/dc Converter Using a Coupled Inductor with its Generalized Structure

  • Hamkari, Sajjad;Moradzadeh, Majid;Zamiri, Elyas;Nasir, Mehdi;Hosseini, Seyed Hossein
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.579-589
    • /
    • 2017
  • In this study a new high step-up dc-dc converter is presented. The operation of the proposed converter is based on the capacitor switching and coupled inductor with a single active power switch in its structure. A passive voltage clamp circuit with two capacitors and two diodes is used in the proposed converter for elevating the converter's voltage gain with the recovered energy of the leakage inductor, and for lowering the voltage stress on the power switch. A switch with a low $R_{DS}$ (on) can be adopted to reduce conduction losses. In the generalized mode of the proposed converter, to reach a desired voltage gain, capacitor stages with parallel charge and series discharge techniques are extended from both sides of secondary side of the coupled inductor. The proposed converter has the ability to alleviate the reverse recovery problem of diodes with circuit parameters. The operating principle and steady-states analyses are discussed in detail. A 40W prototype of the proposed converter is implemented in the laboratory to verify its operation.

플라이백방식의 충·방전 제어기법을 적용한 경두개 자기자극장치 (Transcranial Magnetic Stimulation with repetive charge-discharge ability flyback)

  • 김휘영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.325-328
    • /
    • 2009
  • 자기 자극장치 펄스트레인 기술이 비연속 전도모드에서 플라이백 컨버터로 응용되는 방식을 제안 하고자 한다. 전통적인 펄스폭 제어 방식과는 달리, 자기 자극 펄스 트레인의 주요한 방식은 저전력과 고전력에서 출력전압조절로 구할 수가 있다. 제안한 기술은 불연속 유도에 있는 어떤 변환기에도 적용 가능하다. 그러나, 본 연구에서는 Flyback 연구에 주로 초점을 맞추었다. 본 논문에서, 새로운 제어 연산 논리의 주요 수학 개념은 실험적인 결과가 산출되어 소개 하고자 한다.

  • PDF

휴대폰용 연료전지 전원공급 시스템 개발 및 충방전 특성 연구 (Development and Charge-Discharge Performance Analysis of Direct Methanol Fuel Cell Power Pack for Mobile Phones)

  • 한재성;김영솔;박은성
    • 전기화학회지
    • /
    • 제5권1호
    • /
    • pp.27-29
    • /
    • 2002
  • 본 연구는 메탄올과 공기를 이용하여 상온, 상압에서 전기를 발생시키는 휴대폰용 전원공급 장치의 개발에 관한 것이다. 이 장치는 직접 메탄을 연료전지(DMFC)와 Back-up전지가 병렬로 연결되어 있어, 통화시 소요 전력의 최대 $50\%$ DMFC가 공급하고 나머지 부분은 Back-up 전지가 공급한다. 또한 통화 대기시에는 DMFC가 $100\%$ 필요 전력을 공급하고, 잉여 전력으로 Back-up전지를 충전한다. 상기 DMFC는 유효면적이 $9cm^2$인 8개의 단위전지가 직렬로 연결되어 있으며, 휴대폰의 작동 전압 범위인 2.5-3.9V의 전압을 출력한다.

PMOS 트랜지스터의 ESD 손상 분석 (ESD Failure Analysis of PMOS Transistors)

  • 이경수;정고은;권기원;전정훈
    • 대한전자공학회논문지SD
    • /
    • 제47권2호
    • /
    • pp.40-50
    • /
    • 2010
  • 본 논문은 미세 CMOS 공정의 PMOS 트랜지스터에 높은 전류가 인가될 때 발생하는 기생 PNP 바이폴라 트랜지스터의 스냅백과 breakdown 동작에 초점을 맞춘다. $0.13\;{\mu}m$ CMOS 공정을 이용해 제작한 다양한 I/O 구조를 분석함으로써 PMOSFET의 ESD 손상 현상의 원인을 규명하였다. 즉, 인접한 다이오드로부터 PMOSFET의 바디로 전하가 주입됨으로써 PMOSFET의 기생 PNP 트랜지스터가 부분적으로 turn-on되는 현상이 발생하여 ESD에 대한 저항성을 저하시킨다. 2차원 소자 시뮬레이션을 통해 레이아웃의 기하학적 변수의 영향을 분석하였다. 이를 기반으로 새로운 PMOSFET ESD 손상을 방지하는 설계 방법을 제안한다.