• Title/Summary/Keyword: Characteristics

Search Result 174,907, Processing Time 0.159 seconds

Behaviors of Arsenic in Paddy Soils and Effects of Absorbed Arsenic on Physiological and Ecological Characteristics of Rice Plant lll. Effect of Water Management on As Uptake and the Growth of Rice Plant at As Added Soil (토양중(土壤中) 비소(砒素)의 행동(行動)과 수도(水稻)의 비소흡수(砒素吸收)에 의(依)한 피해생리(被害生理) 생태(生態)에 관(關)한 연구(硏究);Ⅲ.물관리(管理)가 수도의 비소흡수(砒素吸收) 및 생육(生育)에 미치는 영향(影響))

  • Lee, Min-Hyo;Lim, Soo-Kill-H
    • Korean Journal of Environmental Agriculture
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 1987
  • A pot experiment was conducted to find out the effect of water management on the growth and uptake of arsenic and inorganic nutrients of rice plant at As added soil. The arsenic were added to soil at the levels of As 0, 10, 50, 100 and 150 ppm, respectively. Water management was done with two ways: intermittent irrigation from ten days after transplanting, and continuous submersion until harvest. Higher soil As levels increased As content in plant but reduced growth rate. Aresenic content in plant was considerably reduced with intermittent irrigation compared to continuous submersion. Rice growth showed also same trend. With increasing As levels in soil, N content in plant was increased but P, K, Ca, Mg, $SiO_2$, Fe and Mn content in plant were tend to be decreased. These inorganic nutrients in plant were also much absorbed in continuous submersion compared to intermittent irrigation. Soil pH was slightly increased with increasing As levels in soil while soil Eh has no relationship with soil As levels. On the other hand, soil pH was higher in the treatment of continuous submersion than that of intermittent irrigation but soil Eh showed reverse trend. With increasing As levels in soil, water soluble-As and Ca-As fractions in soil tend to be increased with continuous submersion, but these fractions has no tendency with intermittant irrigation.

  • PDF

A Study on Differentiation of Pedestrian space -Focused on a Comparison of the structure of Pedestrian space in the Street- (보행공간디자인의 차별화에 관한 연구 -가로의 보행공간구조의 비교분석을 중심으로-)

  • Kim, Jin-Woo;Rhee, Jae-Won
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.223-232
    • /
    • 2004
  • The pedestrian space on the roads shows virtually different images, depending on the local uniqueness that exists in the roadsides, to the one walking. This sort of characteristics of the region originated from the physical special structures of the roadside building the form of the place. Thus, because of the structural difference of the roadside, Pedestrian sense the difference of regions through other images. Research focused on issues of the local roadside sidewalk spaces as what roadside structure is the type that brings out the unique images of the region, and what facets are pursued additionally here, is needed. A roadside of a prosperous region filled with many Pedestrians is selected as the range for the experiment in order to analyze the structure and image of the pedestrian space. Among the roads of the selected region, the structure of the pedestrian space on the roads with more than four lanes was evaluated. As result of the analysis, the images of 10 pedestrian space could be classified into two groups by the difference in proportions of the Df/H(the width of the sidewalk and the height of the roadside building) and the D/H(the width of the road and the height of the roadside building). In order to observe the images of the pedestrian space classified into two groups, the adjectives used to describe the image of scenery were researched, enabling one to induce the images of the two groups form them. One of the images is the image of prosperities, and the other is the image of pleasantness. In addition, as result to the evaluation focused on the characteristic of the roadside buildings in the selected area, it could be divided into two groups, i.e., the commercial region and the business region. The image of prosperities was sensed on the sidewalks of the commercial region, while the image of pleasantness was seen on that of the business region. This study enabled the acknowledgment that in a pedestrian space on a road structure with more than four lanes, the Pedestrian sense different images, depending on the proportional difference in the width of the sidewalk & the height of the roadside building, and the width of the road & the height of the roadside building. This result is expected to be a good reference when a road structure reflecting the uniqueness of its region is to be designed, and especially when the structure of a pedestrian space is to be created.

  • PDF

Antioxidant Activities of Seasoning Sauces Prepared with Geranium thunbergii sieb. et Zucc. and Crataegi fructus and the Quality Changes of Seasoned Pork during Storage (산사와 현초를 이용한 돈육불고기양념의 항산화 활성과 이로 제조한 양념돈육의 품질특성)

  • Lee, Shin-Ho;Jeong, Eun-Ju;Jung, Tae-Sung;Park, La-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.57-63
    • /
    • 2009
  • In this study, seasoning sauces were prepared with Geranium thunbergii sieb. et Zucc. (1%, PGT), Crataegi fructus (1%, PCF) and their combination (0.5% PGT + 0.5% PCF, bPMGC) and then the quality characteristics of the sauces and seasoned pork were investigated. The lightness, redness and 1,1-diphenyl-2-picrylhydrazyl radical scavenging activity of the sauces were increased by the addition of Crataegi fructus. Sensory qualities such as taste, color and overall acceptability were scored higher in the sauce prepared with Crataegi fructus than the control. The viable cell counts of pork seasoned with the various sauces were 5.04 CFU/g (control), 4.59 CFU/g (PGT), 3.88 CFU/g (PCF) and 4.38 CFU/g (PMGC) after storage for 15 days at $4^{\circ}C$, respectively. The coliform count of the control pork was below 1.0 CFU/g after storage for 25 days and coliform were not detected in PGT, PCF and PMGC after storage for 10 days at $4^{\circ}C$. The thiobarbitunc acid reaotive substance values of PGT, PCF and PMGC were significantly lower than that of control, but volatile basic nitrogen contents were not significantly different between the treated and untreated pork samples during storage. Cooking loss increased in all treatments during storage for 25 days and their water holding capacity increased during storage for 10 days and decreased thereafter. The lightness, redness and yellowness values of PCF were higher than those of the control. The sensory qualities of PCF, including taste, color and overall acceptability, were significantly improved compared to the control. Finally, the pork seasoned with the sauce containing 1% Crataegi fructus extract had significantly improved shelflife, water holding capacity, inhibition of rancidity, color and sensory quality.

Quality Evaluation of Juanbyeo as Aseptic-packaged Cooked Rice (무균포장밥 가공 적합품종 주안벼의 식미특성)

  • Oh, Sea-Kwan;Kim, Dae-Jung;Cheun, A-Reum;Yoon, Mi-Ra;Hong, Ha-Cheol;Choi, Im-Soo;Oh, Yea-Jin;Oh, Ki-Back;Kim, Yeon-Kyu
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.721-726
    • /
    • 2010
  • The objective of this study was to evaluate several varieties of aseptic-packaged cooked rice including Juanbyeo. Quality evaluations, such as by amylose, setback, toyo values and amylograms, were significantly higher in the Juanbyeo as compared to other samples. In addition, the Juanbyeo aseptic-packeged cooked rice showed significantly higher palatability characteristics and had a greater water absorption ratio than the other samples. For cold cooked rice, the relationship between palatability and texture was significantly high (p<0.01). Ilpumbyeo showed high scores for taste as a hot cooked rice, but as a cold cooked rice taste scores were lower than other samples. In the case of Juanbyeo cold cooked rice flavor was improved. When the Juanbyeo aseptic-packaged cooked rice was reheated in a microwave oven, it had better palatability than other varieties. Thus, the results of this study suggested that Juanbyeo can be effectively utilized as aseptic-packaged cooked rice.

Policy suggestions to educate and produce outstanding paramedics in Korea (우수한 1급 응급구조사 인력 양성 및 배출을 위한 정책 제안)

  • Choi, Eun-Sook;Koh, Bong-Yeun;Park, Hee-Jin;Kim, Hyo-Sik;Kwon, Hay-Rran;Choi, Hea-Kyung;Lee, Kyoung-Youl;Yun, Jong-Geun;Hong, Sung-Gi;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.7-19
    • /
    • 2018
  • Purpose: With the purpose of educating and producing outstanding paramedics by enhancing their competencies, this study aimed to make policy suggestions to re-establish the education system and improve the national examination and the certification scheme. Methods: This study used focus group interviews and questionnaires to collect data. Totally, there were 277 subjects, including experts from the education and field. Data were collected from September 9 to 20, 2016, and analyzed using SPSS 22.0. Results: To strengthen the curriculum of paramedics, this study suggested 27 courses with 94 credits as the standardized curriculum and derived 9 core competencies of paramedics. For the national examination, this study suggested consolidating written test subjects, adding scenario questions to practical tests, and applying critical criteria to simple practical tests that performs a procedure, grading these tests on a pass/fail basis. In addition, this study suggested converting certification into license, reflecting paramedics' healthcare job characteristics. Conclusion: The quality of emergency medical services in Korea will improve when those with core competencies that originated from the standardized curriculum based on the results of this study acquire their certification through the national test scheme, and the certification management system creates a virtuous cycle to further enhance paramedics' professionalism.

DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination (HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가)

  • Kwon, Ik-Soo;Hwang, Jae-Sang;Koo, Jae-Hong;Sakamoto, Kuniaki;Lee, Bang-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.

Development of a TBM Advance Rate Model and Its Field Application Based on Full-Scale Shield TBM Tunneling Tests in 70 MPa of Artificial Rock Mass (70 MPa급 인공암반 내 실대형 쉴드TBM 굴진실험을 통한 굴진율 모델 및 활용방안 제안)

  • Kim, Jungjoo;Kim, Kyoungyul;Ryu, Heehwan;Hwan, Jung Ju;Hong, Sungyun;Jo, Seonah;Bae, Dusan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.305-313
    • /
    • 2020
  • The use of cable tunnels for electric power transmission as well as their construction in difficult conditions such as in subsea terrains and large overburden areas has increased. So, in order to efficiently operate the small diameter shield TBM (Tunnel Boring Machine), the estimation of advance rate and development of a design model is necessary. However, due to limited scope of survey and face mapping, it is very difficult to match the rock mass characteristics and TBM operational data in order to achieve their mutual relationships and to develop an advance rate model. Also, the working mechanism of previously utilized linear cutting machine is slightly different than the real excavation mechanism owing to the penetration of a number of disc cutters taking place at the same time in the rock mass in conjunction with rotation of the cutterhead. So, in order to suggest the advance rate and machine design models for small diameter TBMs, an EPB (Earth Pressure Balance) shield TBM having 3.54 m diameter cutterhead was manufactured and 19 cases of full-scale tunneling tests were performed each in 87.5 ㎥ volume of artificial rock mass. The relationships between advance rate and machine data were effectively analyzed by performing the tests in homogeneous rock mass with 70 MPa uniaxial compressive strength according to the TBM operational parameters such as thrust force and RPM of cutterhead. The utilization of the recorded penetration depth and torque values in the development of models is more accurate and realistic since they were derived through real excavation mechanism. The relationships between normal force on single disc cutter and penetration depth as well as between normal force and rolling force were suggested in this study. The prediction of advance rate and design of TBM can be performed in rock mass having 70 MPa strength using these relationships. An effort was made to improve the application of the developed model by applying the FPI (Field Penetration Index) concept which can overcome the limitation of 100% RQD (Rock Quality Designation) in artificial rock mass.

Clinical Significance of Methacholine Bronchial Challenge Test in Differentiating Asthma From COPD (만성폐쇄성폐질환과 천식의 감별진단에서 메타콜린 기관지유발검사의 의의)

  • Hong, Yun Kyung;Chung, Chi Ryang;Paeck, Kyung Hyun;Kim, So Ri;Min, Kyung Hoon;Park, Seoung Ju;Lee, Heung Bum;Lee, Yong Chul;Rhee, Yang Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.5
    • /
    • pp.433-439
    • /
    • 2006
  • Background: Although airway hyper-responsiveness is one of the characteristics of asthma. bronchial hyper-responsiveness has also been observed to some degree in patients with chronic obstructive pulmonary disease (COPD). Moreover, several reports have demonstrated that a number of patients have both COPD and asthma. The methacholine bronchial challenge test (MCT) is a widely used method for the detecting and quantifying the airway hyper- responsiveness, and is one of the diagnostic tools in asthma. However, the significance of MCT in differentiating asthma or COPD combined with asthma from pure COPD has not been defined. The aim of this study was to determine the role of MCT in differentiating asthma from pure COPD. Method: This study was performed prospectively and was composed of one hundred eleven patients who had undergone MCT at Chonbuk National University Hospital. Sixty-five asthma patients and 23 COPD patients were enrolled and their MCT data were analyzed and compared with the results of a control group. Result: The positive rates of MCT were 65%, 30%, and 9% in the asthma, COPD, and control groups, respectively. The mean $PC_{20}$ values of the asthma, COPD, and control groups were $8.1{\pm}1.16mg/mL$, $16.9{\pm}2.21mg/mL$, and $22.0{\pm}1.47mg/mL$, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of MCT for diagnosing asthma were 65%, 84%, 81%, and 69%, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of MCT (ed note: please check this as I believe that these values correspond to the one $PC_{20}$ value. Please check my changes.) at the new cut-off points of$PC_{20}{\leq}16mg/ml$, were 80%, 75%, 78%, and 78%, respectively. Conclusion: MCT using the new cut-off point can be used as a more precise and useful diagnostic tool for distinguishing asthma from pure COPD.

Characteristics of Flexible Transparent Capacitive Pressure Sensor Using Silver Nanowire/PEDOT:PSS Hybrid Film (은나노와이어·전도성고분자 하이브리드 필름을 이용한 유연 투명 정전용량형 압력 센서의 특성)

  • Ahn, Young Seok;Kim, Wonhyo;Oh, Haekwan;Park, Kwangbum;Kim, Kunnyun;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.21-29
    • /
    • 2016
  • In this paper, we developed a flexible transparent capacitive pressure sensor which can recognize X and Y coordinates and the size of force simultaneously by sensing a change in electrical capacitance. The flexible transparent capacitive pressure sensor was composed of 3 layers which were top electrode, pressure sensing layer, and bottom electrode. Silver nanowire(Ag NW)/poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) hybrid film was used for top and bottom flexible transparent electrode. The fabricated capacitive pressure sensor had a total size of 5 inch, and was composed of 11 driving line and 19 sensing line channels. The electrical, optical properties of the Ag NW/PEDOT:PSS and capacitive pressure sensor were investigated respectively. The mechanical flexibility was also investigated by bending tests. Ag NW/PEDOT:PSS exhibited the sheet resistance of $44.1{\Omega}/square$, transmittance of 91.1%, and haze of 1.35%. Notably, the Ag NW/PEDOT:PSS hybrid electrode had a constant resistance change within a bending radius of 3 mm. The bending fatigue tests showed that the Ag NW/PEDOT:PSS could withstand 200,000 bending cycles which indicated the superior flexibility and durability of the hybrid electrode. The flexible transparent capacitive pressure sensor showed the transmittance of 84.1%, and haze of 3.56%. When the capacitive pressure sensor was pressed with the multiple 2 mm-diameter tips, it can well detect the force depending on the applied pressure. This indicated that the capacitive pressure sensor is a promising scheme for next generation flexible transparent touch screens which can provide multi-tasking capabilities through simultaneous multi-touch and multi-force sensing.

Study on Production Performance of Shale Gas Reservoir using Production Data Analysis (생산자료 분석기법을 이용한 셰일가스정 생산거동 연구)

  • Lee, Sun-Min;Jung, Ji-Hun;Sin, Chang-Hoon;Kwon, Sun-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.58-69
    • /
    • 2013
  • This paper presents production data analysis for two production wells located in the shale gas field, Canada, with the proper analysis method according to each production performance characteristics. In the case A production well, the analysis was performed by applying both time and superposition time because the production history has high variation. Firstly, the flow regimes were classified with a log-log plot, and as a result, only the transient flow was appeared. Then the area of simulated reservoir volume (SRV) analyzed based on flowing material balance plot was calculated to 180 acres of time, and 240 acres of superposition time. And the original gas in place (OGIP) also was estimated to 15, 20 Bscf, respectively. However, as the area of SRV was not analyzed with the boundary dominated flow data, it was regarded as the minimum one. Therefore, the production forecasting was conducted according to variation of b exponent and the area of SRV. As a result, estimated ultimate recovery (EUR) increased 1.2 and 1.4 times respectively depending on b exponent, which was 0.5 and 1. In addition, as the area of SRV increased from 240 to 360 acres, EUR increased 1.3 times. In the case B production well, the formation compressibility and permeability depending on the overburden were applied to the analysis of the overpressured reservoir. In comparison of the case that applied geomechanical factors and the case that did not, the area of SRV was increased 1.4 times, OGIP was increased 1.5 times respectively. As a result of analysis, the prediction of future productivity including OGIP and EUR may be quite different depending on the analysis method. Thus, it was found that proper analysis methods, such as pseudo-time, superposition time, geomechanical factors, need to be applied depending on the production data to gain accurate results.