• Title/Summary/Keyword: Characteristic of deterioration

Search Result 194, Processing Time 0.027 seconds

Reliance Analysis for Mechanical Characteristics of ACSR Transmission Line due to a Flame (화염에 의한 ACSR 송전선의 기계적 특성에 관한 신뢰성 분석)

  • 김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.138-146
    • /
    • 2003
  • This paper deals with the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include tension load, extension rate and torsion number for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR 480$\textrm{mm}^2$ which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

A Study on Surface Characteristics of ACSR Transmission Line due to a Flame (화염에 의한 ACSR 송전선의 표면 특성에 관한 연구)

  • 김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.173-180
    • /
    • 2003
  • This paper deals with the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include surface characteristics for a conductor. In addition, there's been an experiment and analysis about the surface characteristics of the wire of ACSR 480$\textrm{mm}^2$ which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

Mechanical Deterioration Characteristics of ACSR due to a Flame (화염으로 인한 ACSR의 기계적 열화 특성)

  • 박창기;이광식;강지원;김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.160-168
    • /
    • 2003
  • In Korea, a large portion of aerial power-transmission cables is installed in the mountains. In the case of a fire in the mountains, steel wires coated with zinc and aluminum wires of those power cables exposed to the fire or near around will be deteriorated by the blaze and the high temperature. Deterioration proceeds by interactions of a variety of factors like quality, manufacturing process, the condition of installation and exposure environment of a wire, and so on. Generally, the characteristic of a conductor affect by a forest fire can not be analyzed without the effect through simulating a forest fire. However, there are little research accomplishments of that kind of simulation about it, and there's been no analysis of a sample exposed to an actual forest fire. This thesis shows the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include the intensity of extension and wrench for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR 480[$\textrm{mm}^2$] which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

Fuzzy Techniques to Establish Improvement Priorities of Water Pipes (상수관로 개량 우선순위 수립을 위한 퍼지 기법)

  • Park, Su-Wan;Kim, Tae-Young;Lim, Ki-Young;Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.11
    • /
    • pp.903-913
    • /
    • 2011
  • In this paper important factors in determining improvement priorities for water pipes were categorized into the effects of a pipe failure to entire pipe network and the characteristics of individual pipe. Subsequently, mathematical models that can quantify these factors were developed using the Fuzzy techniques. The effects of a pipe failure to entire pipe network and the characteristics of individual pipe that were estimated byFuzzy techniques were coined as Fuzzy Importance Index and Fuzzy Characteristic Index, respectively. The Fuzzy Characteristic Index was further categorized into Fuzzy Deterioration Index and Fuzzy Difficulty Index. Considerations were given to applying weights to specific factors in the developed model depending on the circumstances of model applications. To provide an example of the methodology an example pipe network, Net3, of the EPANET program was used. The Fuzzy Importance Index (FII) and Fuzzy Deterioration Index (FDI) were calculated for the Net3 network by considering the hydraulic effects of a pipe failure on the entire pipe network and the pipe deterioration as one of the individual pipe characteristics. Subsequently, the improvement priorities of the pipes in the Net3 pipe network were established based on the FII and FDI.

Material and Deterioration Characteristic Analysis for Stone Sculptures in Gyeongbokgung Royal Palace, Seoul (경복궁 석조조형물의 재질 및 손상특성 분석)

  • Kim, Jiyoung;Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.407-420
    • /
    • 2013
  • The stone sculptures in Gyeongbokgung Royal Palace are mainly composed of granite (884 sculptures, 96.7%) and marble (25 sculptures, 2.7%) that originated in several different quarries. Main deterioration forms are crack (24%), break-out (21%), exfoliation (36%), granular disintegration (9%) and blackening (20%). Crack and break-out are dominant contributors to high physical deterioration degree, and blackening is major weathering form of intensive discoloration. The Gyeonghoeru, Geunjeongjeon and Pumgyeseok areas require urgent and high conservation maintenance with short-term periodic monitoring since proportions of 3-grade deterioration were calculated higher than others as 55% for Gyeonghoeru, 29% for Geunjeongjeon, 11% for Pumgyeseok area. The Pumgyeseok (officials' rank stone), especially, needs intervention for protective facility due to its material vulnerability to weathering in outdoor environment.

Degradation of SOFC Cell/Stack Performance in Relation to Materials Deterioration

  • Yokokawa, Harumi;Horita, Teruhisa;Yamaji, Katsuhiko;Kishimoto, Haruo;Brito, M.E.
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • The characteristic features of solid oxide fuel cells are reviewed from the viewpoint of the thermodynamic variables to be developed inside cells/stacks particularly in terms of gradients of chemical potential, electrical potential and temperature and corresponding flows of air, fuel, electricity and heat. Examples of abrupt destruction of SOFC systems were collected from failures in controlling their steady flows, while continuous degradation was caused by materials behaviors under gradients of chemical potentials during a long operation. The local equilibrium approximation has been adopted in NEDO project on the durability/reliability of SOFC stacks/systems; this makes it possible to examine the thermodynamic stability/reactivity as well as mass transfer under the thermodynamic variable gradients. Major results of the NEDO project are described with a focus on degradation/deterioration of electrolyte and electrode materials.

Relationship between threatened vascular plants and the human population in Japan

  • Hayashi, Naoki;Watanabe, Eriko;Matsuda, Hiroyuki
    • Journal of Ecology and Environment
    • /
    • v.35 no.4
    • /
    • pp.331-341
    • /
    • 2012
  • Using data sets for Japan as a whole, as arranged with approximately $10{\times}10$ km squares (a secondary grid), we investigated the relationship between population density and the habitats of threatened vascular plants listed in the Japanese Red Data Book; depopulated areas in the present and future, areas where under-use may be serious, and those with a predominance of elderly people; and the present state of the habitats in terms of a characteristic land use pattern. Regarding the habitats of threatened vascular plants, the progress of deterioration [$(N_{CR}+N_{EN})/(N_{CR}+N_{EN}+N_{VU})$] in depopulated areas has been confirmed, where $N_{CR}$, $N_{EN}$, and $N_{VU}$ are the numbers of species classified as critically endangered, endangered, and vulnerable, respectively. Moreover, in grid squares used by a human such as farmland, the progress of the deterioration simply increases when population density becomes low. However, for many vascular plants, they are particularly endangered in populous areas. Local populations will decrease throughout Japan with the rate of depopulation in and around large cities being relatively slow. We also propose some issues that need further study. The deterioration by human activity may be reduced. On the other hand, some vascular plants may be adversely influenced by depopulation. Additionally, we should keep a close watch on grasslands and water areas in large cities to preserve vascular plants.

Characteristic Changes of ZnO Arrester Blocks by Multiple-lightning Impuse Currents (다중 뇌충격전류에 의한 산화아연형 피뢰기 소자의 특성 변화)

  • Gil, Gyeong-Seok;Han, Ju-Seop
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.685-690
    • /
    • 2000
  • Multiple-lightning impulse currents are a general feature of the lightning ground f=flash. It is therefore necessary for lightning arresters used in power systems to be estimated by applying not only a single-lightning impulse current but also a multiple-lightning impulse currents. This paper presents the effects of multiple-lightning impulse currents on deterioration of ZnO arrester blocks. The multiple-lightning impulse generator which can produce quadruple 8/20$[\mus]$ 5[kA] with separation time of 30~120[ms] is designed and fabricated. The total energy applied to the arrester block at each impulse is about 1,200[J]. In experiment, various parameters such as leakage current component, reference voltage, and temperature are measured with the number of applied impulse current. Also, micro-structure changes of the ZnO blocks after applying the single and the multiple-lightning impulse currents of 200 times are compared. The experimental results indicate that the types of arrester blocks are more vulnerable to deterioration or damage by multiple-lightning impulse currents.

  • PDF

Structural Characteristic Analysis of an Ultra-Precision Machine for Machining Large-Surface Micro-Features (초정밀 대면적 미세 형상 가공기의 구조 특성 해석)

  • Kim, Seok-Il;Lee, Won-Jae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1469-1474
    • /
    • 2007
  • In recent years, research to machine large-surface micro-features has become important because of the light guide panel of a large-scale liquid crystal display and the bipolar plate of a high-capacity proton exchange membrane fuel cell. In this study, in order to realize the systematic design technology and performance improvements of an ultra-precision machine for machining the large-surface micro-features, a structural characteristic analysis was performed using its virtual prototype. The prototype consisted of gantry-type frame, hydrostatic feed mechanisms, linear motors, brushless DC servo motor, counterbalance mechanism, and so on. The loop stiffness was estimated from the relative displacement between the tool post and C-axis table, which was caused by a cutting force. Especially, the causes of structural stiffness deterioration were identified through the structural deformation analysis of sub-models.

  • PDF

Theoretical Characteristics of the Probe with Respect to the Engine Oil States (엔진오일 상태에 대한 프로브의 이론 특성)

  • Kim, Young-Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.22-24
    • /
    • 2012
  • Depending on the status of the engine oil, the dielectric constant is changed. Dielectric constant of oil is related to the characteristic impedance of the probe and the characteristic impedance of the probe determines the reflected signal. In this paper, we derive an equivalent circuit of the probe and using the dielectric constant obtained by measuring the capacitance, the theoretical reflection coefficient of the probe was calculated. In the results, if the engine oil is deteriorated, we can see that the reflection coefficient is increased.