• Title/Summary/Keyword: Channel experiment

Search Result 912, Processing Time 0.029 seconds

Studies on the Utilization of Persimmons -(Part 1) Effect of Carton Dioxide Treatment on the Removal of Astringency- (감의 이용(利用)에 관(關)한 연구(硏究) -제1보(第一報) 탄산(炭酸)가스처리(處理)가 탈삽(脫澁)에 미치는 영향(影響)-)

  • Seu, Ohn-Soo;Sohn, Tae-Hwa
    • Applied Biological Chemistry
    • /
    • v.19 no.2
    • /
    • pp.93-98
    • /
    • 1976
  • The experiment was made to investigate concentrations of $CO_2\;and\;O_2$ in the removal of astringency of persimmon fruits and to study the changes of total, reducing sugar and hardness during the removal of astringency. 1. During the removal of astringency of persimmon fruits, channel of tannin content showed the rapid decrease in high concentration of $CO_2$ and the gradual decrease in low concentration of $CO_2$. 2. Concentration of oxygen did not show effect on the removal of astringency at high concentration of $CO_2$ but at low concentration of $CO_2$ in Chungdo-Bansi. 3. Optimal concentration of the removal of astringency was $60{\sim}70%,\;CO_2$ and $6{\sim}8%\;O_2$ in Chungdo-Bansi and Sagoksi 4. In changes of sugar content total sugar was decreased and reducing sugar was increased.

  • PDF

Epicenter Estimation Using Real-Time Event Packet of Quanterra digitizer (Quanterra 기록계의 실시간 이벤트 패킷을 이용한 진앙 추정)

  • Lim, In-Seub;Sheen, Dong-Hoon;Shin, Jin-Soo;Jung, Soon-Key
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.4
    • /
    • pp.316-327
    • /
    • 2009
  • A standard for national seismological observatory was proposed on 1999. Since then, Quanterra digitizer has been installed and is operating on almost all of seismic stations which belong to major seismic monitoring organizations. Quanterra digitizer produce and transmit real-time event packet and data packet. Characteristics of event packet and arrival time of each channel's data packet on data center were investigated. Packet selection criteria using signal to noise ratio (hereafter SNR) and signal period from real-time event packet based on 100 samples per second (hereafter sps) velocity data were developed. Estimation of epicenter using time information of the selected event packet were performed and tested. A series of experiment show that event packets were received approximately 3~4 second earlier than data packets and the number of event packet was only 0.3% compare to data packets. Just about 5% against all of event packets were selected as event packet were related P wave of real earthquake. Using the selected event packets we can estimate an epicenter with misfit less than 10 km within 20 sec for local earthquake over magnitude 2.5.

Color Image Rendering using A Modified Image Formation Model (변형된 영상 생성 모델을 이용한 칼라 영상 보정)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.71-79
    • /
    • 2011
  • The objective of the imaging pipeline is to transform the original scene into a display image that appear similar, Generally, gamma adjustment or histogram-based method is modified to improve the contrast and detail. However, this is insufficient as the intensity and the chromaticity of illumination vary with geometric position. Thus, MSR (Multi-Scale Retinex) has been proposed. the MSR is based on a channel-independent logarithm, and it is dependent on the scale of the Gaussian filter, which varies according to input image. Therefore, after correcting the color, image quality degradations, such as halo, graying-out, and dominated color, may occur. Accordingly, this paper presents a novel color correction method using a modified image formation model in which the image is divided into three components such as global illumination, local illumination, and reflectance. The global illumination is obtained through Gaussian filtering of the original image, and the local illumination is estimated by using JND-based adaptive filter. Thereafter, the reflectance is estimated by dividing the original image by the estimated global and the local illumination to remove the influence of the illumination effects. The output image is obtained based on sRGB color representation. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.

EEG 16 channel variations between the non-stimulation and the moxibustion stimulated subjects for CV4, CV8, and CV12 acupuncture points (중완, 신궐 및 관원 경혈의 뜸 자극과 무 자극 대상군의 16채널 뇌파 변화에 관한 연구)

  • Yoon, Dong-Eop;Song, Hong-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2755-2760
    • /
    • 2010
  • The moxibustion therapy of orient medical is well known. Moxibustion method is used to burning moxibustion. The variation factors of the moxibustion stimulation for body can be applied to the electronic moxibustion method. This study is to analyze and examine the electroencephalogram(EEG) variations for moxibustion stimulation. In experiment, we divided six healthy male subjects into two same sized groups : with and without stimuli. The given stimuli are the moxibustion for CV4(Kwan-Won), CV8(Shin-Guel), and CV12(Jung-wan) acupuncture points. We have analyzed the power spectrum for ${\alpha}$, ${\beta}$, ${\delta}$, ${\Theta}$ waves and the average EEG variation level and each channels variation level of EEG. The result was that the moxibustion stimulation decreased the EEG levels of parietal lobe(ch 2, 3, 6, 7) according to the somatosensory system. And the apparent different points are that mild-heat($42{\sim}44^{\circ}C$) stimulation generating ${\alpha}$-wave is increased and ${\beta}$-wave is decreased, also slight-hot($45{\sim}48^{\circ}C$) stimulation made ${\alpha}$-wave decrease and ${\beta}$-wave increase for occipital lobe(ch 4,8) on the simulation group.

Performance of CWDM Fabricated by the PLC-AWG Technology (평판형 AWG 기술을 이용한 광대역 파장다중화/역다중화 소자의 제작 및 특성)

  • Moon, H.M.;Kwak, S.C.;Hong, J.Y.;Lee, K.H.;Kim, D.H.;Kim, J.J.;Choi, S.Y.;Lee, J.G.;Lee, J.H.;Lim, K.G.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.3
    • /
    • pp.185-189
    • /
    • 2007
  • A novel technology for CWDM (Coarse Wavelength Division Multiplexer) utilizing a PLC (Planar Lightwave Circuit)-AWG (Arrayed Waveguide Grating) fabrication process is proposed. BPM (Beam Propagation Method) Simulation results on the employed parabolic-horn-type input slab waveguide of AWG and the performance of the 20 nm-channel spacing CWDM with flattened passband are presented. Waveguides of $0.75{\triangle}%$ have been used in this experiment and the insertion loss at the peak wavelength is 3.5 dB for a Gaussian spectrum and is 4.8 dB for a flat-top spectrum. The bandwidth at 3 dB is better than 10 nm and 13 nm for Gaussian and flat-top spectra, respectively.

A Novel Runner Design for Flow Balance of Cavities in Multi-Cavity Injection Molding (다수 빼기 사출성형에서 캐비티간 충전균형을 위한 새로운 런너의 설계)

  • Park, Seo-Ri;Kim, Ji-Hyun;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.561-568
    • /
    • 2009
  • Small injection molded articles are generally molded by multi-cavity injection molding. The most important thing in multi-cavity molding is flow imbalance among the cavities because it affects the physical property and the quality of products. The cavity filling balance can be achieved by flow balance in the runner through the thermal balance. In this study, novel screw type runner or helical type runner has been developed for the flow balance in the runner and performed experiment and computer simulation. Flow balance has been observed using various screw type runners for several resins such as amorphous and crystalline polymers including low and high viscosities grades. Flow balance experiments have been performed for various injection speeds since the flow balance can be affected by injection speed among the injection conditions. Experimental results have been compared with computational results and they showed good agreement. The cavity filling balance can be achieved by the screw runner where the temperature distribution is uniform through the circulation flow along the screw channel in the screw runner. It has been verified that the novel screw runner is very effective device in flow balance in the multi-cavity injection molding. cavity filling imbalance, multi-cavity injection molding, runner design, screw runner, thermal balance.

Evaluation for Optimal HUD Location on a Train Using EEG (뇌파를 이용한 열차 최적의 HUD위치 평가)

  • Wang, Chang-Won;Kim, Yong-Kyu;Min, Se-Dong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.11
    • /
    • pp.985-993
    • /
    • 2014
  • This paper suggested a new evaluation method for optimal HUD position through a correlation based on between biological signal as and statistical analysis which using (Electroencephalogram, EEG) and ANOVA. This experiment was conducted two kinds of method to evaluate the optimal HUD position. At first, visual stimulus suggested from six different positions(the top and the bottom of the left, the top and the bottom of the center and the top and the bottom of the right on the screen) in laboratory and an object image was shown for 30 seconds in a screen which has $235{\times}197cm2$ size. And second, HUD image was configured from three different positions and an object image was shown for 30 seconds in a screen. EEG, which used ${\alpha}$-wave and ${\beta}$-wave for evaluate an emotional stability, were measured from Fp1, Fp2, F7 and F8 channel based on ten to twenty electrode system. From the result in laboratory, F7 ${\beta}$-wave was shown statistically significant to significance probability of 0.006 and between ${\alpha}$-wave and ${\beta}$-wave were showed a negative correlation(r=-0.190). Also, Both the top of left and the bottom of center were showed lower ${\beta}$-wave than the bottom of right. From the result in railway simulator, Fp1 ${\beta}$-wave was appeared statistically significant as significance probability of 0.033 and it was showed lower ${\beta}$-wave than center. The outcome of this study will be helpful about evaluation of optimal HUD position through correlation between alpha wave and beta wave.

Medical Image Compression Using JPEG International Standard (JPEG 표준안을 이용한 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yoen
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.504-506
    • /
    • 1993
  • The Joint Photographic Experts Group (JPEG) standard was proposed by the International Standardization Organization (ISO/SC 29/WG 10) and the CCITT SG VIII as an international standard for digital continuous-tone still image compression. The JPEG standard has been widely accepted in electronic imaging, computer graphics, and multi-media applications, however, due to the lossy character of the JPEG compression its application in the field of medical imaging has been limited. In this paper, the JPEG standard was applied to a series of head sections of magnetic resonance (MR) images (256 gray levels, $256{\times}256$ size) and its performance was investigated. For this purpose, DCT-based sequential mode of the JPEG standard was implemented using the CL550 compression chip and progressive and lossless coding was implemented by software without additional hardware. From the experiment, it appears that the compression ratio of about 10 to 20 was obtained for the MR images without noticeable distortion. It is also noted that the error signal between the reconstructed image by the JPEG and the original image was nearly random noise without causing any special-pattern-related artifact. Although the coding efficiency of the progressive and hierarchical coding is identical to that of the sequential coding in compression ratio and SNR, it has useful features In fast search of patient Image from huge image data base and in remote diagnosis through slow public communication channel.

  • PDF

Experimental Investigation on the Droplet Entrainment in the Air-Water Horizontal Stratified Flow (물-공기 수평 성층류 유동조건에서 액적이탈 현상에 대한 실험연구)

  • Bae, Byeong Geon;Yun, Byong Jo;Kim, Kyoung Doo;Bae, Byoung Uhn
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.114-122
    • /
    • 2015
  • In the high convective gas flow condition, irregular shaped water waves from which droplet entrainment occurs are generated under horizontally stratified two-phase flow condition. KAERI proposed a new mechanistic droplet entrainment model based on the momentum balance equation consisting of the shear stress, surface tension, and gravity forces. However, this model requires correlation or experimental data of several physical parameters related to the wave characteristics. In the present study, we tried to measure the physical parameters such as wave slope, wave hypotenuse length, wave velocity, wave frequency, and wavelength experimentally. For this, an experiment was conducted in the horizontal rectangular channel of which width, height, and length are, respectively, 40 mm, 50 mm, and 4.2 m. In the present test, the working fluids are chosen as air and water. The PIV technique was applied not only to obtain images for phase interface waves but also to measure the velocity field of the water flow. Additionally, we developed the parallel wire conductance probe for the confirmation of wave height from PIV image. Finally, we measured the physical parameters to be used in the validation of new droplet entrainment model.

Study on Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Heating Operating Condition (난방운전 조건하에서 $CO_2$ 열펌프용 내부 열교환기의 열전달 특성에 대한 연구)

  • Kim, Dae-Hoon;Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.116-123
    • /
    • 2008
  • In order to study the heat transfer, effectiveness and pressure drop of an internal heat exchanger (IHX) for $CO_2$, heat pump under heating condition, the experiment and numerical analysis were performed. Four kinds of IHXs were used. The section-by-section method and Hardy-Cross method were used for the numerical analysis. The effects of IHX on the flow rate of refrigerant, the IHX length, the operating condition of a gas-cooler and an evaporator and the type of IHXs were investigated. With increasing the flow rate, the heat transfer rate increased about 25%. The heat transfer of the micro-channel tube was larger about 100% than that of the coaxial tube. With increasing the IHX length, the heat transfer rate decreased. The low-side pressure drop was larger compared with that of the high-side. And the pressure drop of the microchannel tube was larger about 100% than that of the coaxial tube. With increasing the high-side temperature and decreasing the low-side temperature, the heat transfer rate increased about 3%. From this study, we can see that new correlation on $CO_2$ heat transfer characteristics and tube type is necessary.