• Title/Summary/Keyword: Channel Number

Search Result 2,729, Processing Time 0.032 seconds

Conjugate Heat Transfer Characteristics in a Ribbed Channel:Effect of Reynolds Number and Heat Capacity Ratio (요철이 설치된 채널 내에서 레이놀즈수와 열용량비에 따른 복합열전달 특성)

  • Song, Jeong-Chul;Ahn, Joon;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2297-2302
    • /
    • 2007
  • Numerical simulations are conducted to analyze conjugate heat transfer characteristics in a ribbed channel. In this simulation, the effects of Reynolds number and heat capacity of the solid channel wall on convective heat transfer are observed in the turbulent flow regime. In the case of the conducting wall against isothermal wall, the relative ratio of the thermal resistance between the solid wall and the flow field varies with Reynolds number. Thus the characteristics of the conjugate heat transfer are changed with the Reynolds number. Heat capacity ratio affects the temperature fluctuation inside solid wall. The temperature fluctuation inside the solid wall decreases with increasing the heat capacity of the solid wall so that the convective heat transfer increases. When the thermal conductivity ratio is smaller than 10, the effects of flow characteristics on heat transfer are changed.

  • PDF

Applying the Nash Equilibrium to Constructing Covert Channel in IoT

  • Ho, Jun-Won
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.243-248
    • /
    • 2021
  • Although many different types of covert channels have been suggested in the literature, there are little work in directly applying game theory to building up covert channel. This is because researchers have mainly focused on tailoring game theory for covert channel analysis, identification, and covert channel problem solving. Unlike typical adaptation of game theory to covert channel, we show that game theory can be utilized to establish a new type of covert channel in IoT devices. More specifically, we propose a covert channel that can be constructed by utilizing the Nash Equilibrium with sensor data collected from IoT devices. For covert channel construction, we set random seed to the value of sensor data and make payoff from random number created by running pseudo random number generator with the configured random seed. We generate I × J (I ≥ 2, J ≥ 2) matrix game with these generated payoffs and attempt to obtain the Nash Equilibrium. Covert channel construction method is distinctly determined in accordance with whether or not to acquire the Nash Equilibrium.

Study on the Gi Boo Lon of Su Wen (《소문ㆍ기부론》에 대한 연구)

  • Oh Yi Soo;Kim Bo Hun;Roh Seung Jo;Cheon Sang Muk;Kim Jong Ho;Jeong Hyun Jong;Lee Jong Soon;Jeong Heon Young;Keum Kyung Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.5
    • /
    • pp.1275-1284
    • /
    • 2004
  • This paper discuss the acupoints and flowing of channel. The Acupoints issued from the Foot Taiyin channel's energy are seventy three. The acupoints issued from the Foot Shaoyang channel's energy are sixty two. The acupoints issued from the Foot Yangming channel's energy are sixty eight. The acupoints issued from the Hand Taiyang channel's energy are thirty six. The acupoints issued from the Hand Yangming channel's energy are twenty two. The acupoints issued from the Hand Shaoyang channel's energy are thirty two. The acupoints issued from the Du channel's energy are twenty eight. The acupoints issued from the Ren channel's energy are twenty eight. The acupoints issued from the Chong channel's energy are twenty two. The acupoints issued from the Foot Shaoyin channel are the Lianquan points of kidney channel on each side under the tongue. The total points above amount of three hundred and sixty five. Urinary Bladder Channel of Foot-Taiyang: The number of acupoints is 67. Gall Bladder Channel of Foot-Shaoyang: The number of acupoints is 44. Stomach Channel of Foot-Yangming: The number of acupoints is 45.

Convective Heat Transfer in a Channel with Isothermal Rectangular Beams (등온사각빔이 부착된 채널에서의 대류열전달)

  • Ree, J.S.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.63-72
    • /
    • 1995
  • Convective heat transfer in a two-dimensional horizontal and vertical channel with isothermal rectangular beams attached to one adiabatic wall is investigated from the numerical solution of Navier-Stokes and energy equations. The solutions have been obtained for dimensionless beam spacings, S/L=1~4, aspect ratios of beam, H/B=0.25~4, Reynolds numbers, Re=50~1000 and Grashof numbers, $Gr=0{\sim}5{\times}10^4$. The total mean Nusselt number, Nu_T for horizontal and vertical channels shows same value at Gr=0. As Gr increases, Nu_T for horizontal channel increases, but Nu_T for vertical channel shows similar value at S/L=2, H/B=0.25, Re=100. The total mean Nusselt number for horizontal channel is higher than that for vertical channel. As H/B increases, $Nu_T$ for both channel decrease at $Gr=10^4$, Re=100.

  • PDF

Three-Dimensional Numerical Study on the Vortex Flow in a Horizontal Channels with High Viscous Fluid(2) (수평채널 내 고 점성유체의 볼텍스 유동에 관한 3차원 수치해석(2))

  • Piao, Ri-Long;Kim, Jeong-Soo;Bae, Dae-Seok
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.36-42
    • /
    • 2015
  • TMixed convective flow in a bottom heated and top cooled rectangular channel can be significantly affected by the channel aspect ratio, Prandtl number, Reynolds number, Rayleigh number and angle of inclination. In such a mixed convection, the flow pattern plays an important role in various technological processes. In this study, a numerical investigation is carried out to explore mixed convection in a three-dimensional rectangular channel with bottom heated and top cooled uniformly. The three-dimensional governing equations are discretized using the finite volume method. In the range of low Reynolds number($0{\leq}Re{\leq}9.6{\times}10^{-2}$), the effects of the aspect ratio($2{\leq}AR{\leq}12$) and Gr/Re are presented and discussed. The longitudinal roll number in the channel is increased with increasing aspect ratio, and the roll number induced, regardless of the aspect ratio number, is even in the range of aspect ratios between 2 and 12, New vortex flow structure containing inclined longitudinal rolls is found, which is affected by aspect ratio and Reynolds number. The ratio Gr/Re is used to check the relative magnitudes of forced and natural convection in the mixed convective flow of high viscous fluid.

Dynamic Channel Assignment Scheme Based on the Number of Success and Collision of Random Channel in HIPERLAN/2 (HIPERLAN/2에서 랜덤채널의 성공수와 충돌수에 기반한 동적 채널할당 방안)

  • Lim, Seog-Ku
    • Journal of Digital Contents Society
    • /
    • v.12 no.3
    • /
    • pp.347-353
    • /
    • 2011
  • In HIPERLAN/2, the radio channels are assigned by AP(Access Point) that is centrally operated and the MAC protocol is based on TDMA/TDD. Mobile terminal that data transmission is necessary to uplink requests radio resource to AP through RCH channel. The changing number of RCHs in each MAC frame is important because too many RCHs may result in a waste of radio resources and too few RCHs may result in many access collisions and prolong time that connect to AP. Hence the number of RCH should be allocated properly according to traffic. From these point, this paper proposes an scheme that dynamically assigned the number of RCH which is based on the number of success and collision of message in previous MAC frame. To prove efficiency of proposed scheme, lots of simulations are conducted and analyzed.

Design of a Voltage Synthesizer Using.Microprocessor for Television Channel Selection (마이크로프로세서를 이용한 전압합성방식의 텔리비젼 채널 선국회로 설계)

  • 조진호;이건일
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.2
    • /
    • pp.1-9
    • /
    • 1980
  • A voltage synthesizing channel selection circuit was designed to improve on the conventional vol tape synthesizer which has been memorized each charnel's tuning vol cage itself. In the course of this study, tuning voltage was calculated by channel number entered from 10 keys. Then this circuit has tie function of direct access channel selection and rear display of channel number for the whole range of UHF and VHF, Attention was also given to realize the fine tuning by searching each commended channel, and the sequential selection by using 2keys, and the flash of channel indicator in case of inactive station.

  • PDF

An Efficient Channel Estimation for Amplify and Forward Cooperative Diversity with Relay Selection

  • Jeong, Hyun-Doo;Lee, Jae-Hong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.94-98
    • /
    • 2009
  • In this paper, we propose a new channel estimation scheme for amplify and forward cooperative diversity with relay selection. In order to select best relay, it is necessary to know channel state information (CSI) at the destination. Most of the previous works, however, assume that perfect CSI is available at the destination. In addition, when the number of relay is increased it is difficult to estimate CSI through all relays within coherence time of a channel because of the large amount of frame overhead for channel estimation. In a proposed channel estimation scheme, each terminal has distinct pilot signal which is orthogonal each other. By using orthogonal property of pilot signals, CSI is estimated over two pilot signal transmission phases so that frame overhead is reduced significantly. Due to the orthogonal property among pilot signals, estimation error does not depend on the number of relays. Simulation result shows that the proposed channel estimation scheme provides accurate CSI at the destination.

  • PDF

Heat Transfer and Friction Factors in the Channel with an Inclined Square Diamond Type Perforated Baffle (정 다이아몬드 형 구멍이 있는 배플을 가진 채널에서의 열전달과 마찰계수)

  • Oh, S.K.;Putra, A.B.K.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.26-31
    • /
    • 2008
  • This experimental study investigates the local heat transfer enhancement characteristics and the associated frictional head loss in the rectangular channel with a single inclined baffle. Four different types of the baffle are used. The inclined baffles have the width of 19.8 cm, the square diamond of $2.55cm{\times}2.55cm$, and the inclination angle of 5o, and number of holes of up to 9. Reynolds number is varied between 23,000 and 57,000. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle. It is found that the heat transfer performance of baffle type II(3 hole baffle) has the best values.

  • PDF

Characteristics of the Mixed Convection Flow and Heat Transfer in a Channel with Open Cavity (개방된 캐비티를 가진 채널 내에서의 혼합대류 유동과 열전달 특성)

  • Ko, Y.C.;Bae, D.S.;Kim, N.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.56-64
    • /
    • 2007
  • A numerical simulation is carried out mixed convection in horizontal channel with a heat source from below of rectangular cavity. Finite volume method was employed for the discretization and PISO algorithm was used for calculating pressure term. The parameters governing the problem are the Reynolds number ($10^{-2}{\leq}Re{\leq}50$), the Rayleigh number ($10^3{\leq}Ra{\leq}2.06{\times}10^5$), the Prandtl number ($0.72{\leq}Pr{\leq}909$), the aspect ratio ($0.5{\leq}AR=W/H{\leq}2$) and the angle of inclination ($0^{\circ}{\theta}60^{\circ}$). Mean Nusselt number distributions were obtained and effect of Reynolds number, Rayleigh number and Prandtl number on mixed convection in the horizontal channel with rectangular cavity were investigated.

  • PDF