• Title/Summary/Keyword: Change of Use

Search Result 8,103, Processing Time 0.048 seconds

Changes of Brain Natriuretic Peptide Levels according to Right Ventricular HemodynaMics after a Pulmonary Resection (폐절제술 후 우심실의 혈역학적 변화에 따른 BNP의 변화)

  • Na, Myung-Hoon;Han, Jong-Hee;Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Choi, Jae-Sung;Yoon, Seok-Hwa;Choi, Si-Wan
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.593-599
    • /
    • 2007
  • Background: The correlation between levels of brain natriuretic peptide (BNP) and the effect of pulmonary resection on the right ventricle of the heart is not yet widely known. This study aims to assess the relationship between the change in hemodynamic values of the right ventricle and increased BNP levels as a compensatory mechanism for right heart failure following pulmonary resection and to evaluate the role of the BNP level as an index of right heart failure after pulmonary resection. Material and Method: In 12 non small cell lung cancer patients that had received a lobectomy or pnemonectomy, the level of NT-proBNP was measured using the immunochemical method (Elecsys $1010^{(R)}$, Roche, Germany) which was compared with hemodynamic variables determined through the use of a Swan-Garz catheter prior to and following the surgery. Echocardiography was performed prior to and following the surgery, to measure changes in right ventricular and left ventricular pressures. For statistical analysis, the Wilcoxon rank sum test and linear regression analysis were conducted using SPSSWIN (version, 11.5). Result: The level of postoperative NT-proBNP (pg/mL) significantly increased for 6 hours, then for 1 day, 2 days, 3 days and 7 days after the surgery (p=0.003, 0.002, 0.002, 0.006, 0.004). Of the hemodynamic variables measured using the Swan-Ganz catheter, the mean pulmonary artery pressure after the surgery when compared with the pressure prior to surgery significantly increased at 0 hours, 6 hours, then 1 day, 2 days, and 3 days after the surgery (p=0.002, 0,002, 0.006, 0.007, 0.008). The right ventricular pressure significantly increased at 0 hours, 6 hours, then 1 day, and 3 days after the surgery (p=0.000, 0.009, 0.044, 0.032). The pulmonary vascular resistance index [pulmonary vascular resistance index=(mean pulmonary artery pressure-mean pulmonary capillary wedge pressure)/cardiac output index] significantly increased at 6 hours, then 2 days after the surgery (p=0.008, 0.028). When a regression analysis was conducted for changes in the mean pulmonary artery pressure and NT-proBNP levels after the surgery, significance was evident after 6 hours (r=0.602, p=0.038) and there was no significance thereafter. Echocardiography displayed no significant changes after the surgery. Conclusion: There was a significant correlation between changes in the mean pulmonary artery pressure and the NT-proBNP level 6 hours after a pulmonary resection. Therefore, it can be concluded that changes in NT-proBNP level after a pulmonary resection can serve as an index that reflects early hemodynamic changes in the right ventricle after a pulmonary resection.

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

Evaluation of indirect N2O Emission from Nitrogen Leaching in the Ground-water in Korea (우리나라 농경지에서 질소의 수계유출에 의한 아산화질소 간접배출량 평가)

  • Kim, Gun-Yeob;Jeong, Hyun-Cheol;Kim, Min-Kyeong;Roh, Kee-An;Lee, Deog-Bae;Kang, Kee-Kyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1232-1238
    • /
    • 2011
  • This experiment was conducted to measure concentration of dissolved $N_2O$ in ground-water of 59 wells and to make emission factor for assessment of indirect $N_2O$ emission at agricultural sector in agricultural areas of Gyeongnam province from 2007 to 2010. Concentrations of dissolved $N_2O$ in ground-water of 59 wells were ranged trace to $196.6{\mu}g-N\;L^{-1}$. $N_2O$ concentrations were positively related with $NO_3$-N suggesting that denitrification was the principal reason of $N_2O$ production and $NO_3$-N concentration was the best predictor of indirect $N_2O$ emission. The ratio of dissolved $N_2O$-N to $NO_3$-N in ground-water was very important to make emission factor for assessment of indirect $N_2O$ emission at agricultural sector. The mean ratio of $N_2O$-N to $NO_3$-N was 0.0035. It was greatly lower than 0.015, the default value of currently using in the Intergovernmental Panel on Climate Change (IPCC) methodology for assessing indirect $N_2O$ emission in agro-ecosystems (IPCC, 1996). It means that the IPCC's present nitrogen indirect emission factor ($EF_{5-g}$, 0.015) and indirect $N_2O$ emission estimated with IPCC's emission factor are too high to use adopt in Korea. So we recommend 0.0034 as national specific emission factor ($EF_{5-g}$) for assessment of indirect $N_2O$ emission at agricultural sector. Using the estimated value of 0.0034 as the emission factor ($EF_{5-g}$) revised the indirect $N_2O$ emission from agricultural sector in Korea decreased from 1,801,576 ton ($CO_2$-eq) to 964,645 ton ($CO_2$-eq) in 2008. The results of this study suggest that the indirect Emission of nitrous oxide from upland recommend 0.0034 as national specific emission factor ($EF_{5-g}$) for assessment of indirect $N_2O$ emission at agricultural sector.

Studies on the N-compounds during Chung-Kook-Jang Meju Fermentation (1) -Changes of Soybean Protein during Chung-Kook-Jang Meju Fermentation- (청국장(淸國醬) 메주 발효과정중(醱酵過程中)의 질소화합물(窒素化合物)의 소장(消長)에 관(關)한 연구(硏究)(I)-대두단백질(大豆蛋白質)의 소장(消長)에 관(關)하여-)

  • Park, Ke-In
    • Applied Biological Chemistry
    • /
    • v.15 no.2
    • /
    • pp.93-109
    • /
    • 1972
  • Three lots of Chung-Kook-Jang were prepared by the use of 2 strains of Bacillus subtilis and Bacillus natto. For four samples taken from each lot in 12 hrs interval changes of nitrogenous compounds, insoluble protein, water soluble protein, peptides, free amino acids, amino and ammonia nitrogens during Chung-Kook-Jang fermentation, were studied together with the changes of moisture, pH, proteolytic enzyme activity. In addition the average peptide length of the peptides of a Bacillus subtilis lot was determined by the method of molecular sieving using ion exchange resin. The results were as follows: 1. The contents of moisture and total-nitrogen changed little in all samples throughout the fermentation as it would be expected. 2. In all three experimental lots the pH became higher gradually from the initial value of 6.65 to the final $7.5{\sim}7.85$ during the fermentation. Proteolytic enzyme activities, in accordance with this pH change, steadily increased up to $48{\sim}60$ hrs. of fermentation and then slightly decreased, probably affected by the high pH. The most strong proteolytic activity was observed in the experimental Chung-Kook-Jang fermentation lot using the Bacillus subtilis K-27 isolated by the author. 3. The contents of insoluble protein nitrogen in soybeans increased markedly (5%) by the cooking, after steeping 12 hrs in water. During the Chung-Kook-Jang fermentation, however, it decreased from 1/2 to 1/10 of that of the cooked soybeans. 4. The contents of water soluble protein nitrogen (5%) whereas, greatly decreased to the value of 1.0% by the cooking; but little changed further during the fermentation, 5. The total contents (0.25%) of peptides, amino, and ammonia-nitrogens, PAA-N., increased almost double by the cooking and steadily became higher as the fermentation proceeded, reaching finally up to$4{\sim}7%$ in 72 hrs fermentation. 6. The amounts of free amino acids of soybean generally decreased during the processing of cooking, even some of them like glutamic acid were destroyed completely, However in the subsequent Chung-Kook-Jang fermentation for 72 hrs., they showed from several to a few hundreds folds increases depending upon the kinds of amino acids. Valine which was contained in HCl-hydrolyzed steeped or cooked soybeans in amounts $220{\sim}267mg%$ was not detected at all as the free amino acid in all fermented samples. 7. Average peptide length (APL) of all fractions, eluted and fractionated by using the Dowex-50 ion exchange resin column, and fraction collector showed the highest value for the cooked soybean and then decreased as the fermentation proceeded. The APL value of effluent showed the highest in 12 hrs fermented sample, The value decreased thereafter by fermentation.

  • PDF

Antecedents of Manufacturer's Private Label Program Engagement : A Focus on Strategic Market Management Perspective (제조업체 Private Labels 도입의 선행요인 : 전략적 시장관리 관점을 중심으로)

  • Lim, Chae-Un;Yi, Ho-Taek
    • Journal of Distribution Research
    • /
    • v.17 no.1
    • /
    • pp.65-86
    • /
    • 2012
  • The $20^{th}$ century was the era of manufacturer brands which built higher brand equity for consumers. Consumers moved from generic products of inconsistent quality produced by local factories in the $19^{th}$ century to branded products from global manufacturers and manufacturer brands reached consumers through distributors and retailers. Retailers were relatively small compared to their largest suppliers. However, sometime in the 1970s, things began to slowly change as retailers started to develop their own national chains and began international expansion, and consolidation of the retail industry from mom-and-pop stores to global players was well under way (Kumar and Steenkamp 2007, p.2) In South Korea, since the middle of the 1990s, the bulking up of retailers that started then has changed the balance of power between manufacturers and retailers. Retailer private labels, generally referred to as own labels, store brands, distributors own private-label, home brand or own label brand have also been performing strongly in every single local market (Bushman 1993; De Wulf et al. 2005). Private labels now account for one out of every five items sold every day in U.S. supermarkets, drug chains, and mass merchandisers (Kumar and Steenkamp 2007), and the market share in Western Europe is even larger (Euromonitor 2007). In the UK, grocery market share of private labels grew from 39% of sales in 2008 to 41% in 2010 (Marian 2010). Planet Retail (2007, p.1) recently concluded that "[PLs] are set for accelerated growth, with the majority of the world's leading grocers increasing their own label penetration." Private labels have gained wide attention both in the academic literature and popular business press and there is a glowing academic research to the perspective of manufacturers and retailers. Empirical research on private labels has mainly studies the factors explaining private labels market shares across product categories and/or retail chains (Dahr and Hoch 1997; Hoch and Banerji, 1993), factors influencing the private labels proneness of consumers (Baltas and Doyle 1998; Burton et al. 1998; Richardson et al. 1996) and factors how to react brand manufacturers towards PLs (Dunne and Narasimhan 1999; Hoch 1996; Quelch and Harding 1996; Verhoef et al. 2000). Nevertheless, empirical research on factors influencing the production in terms of a manufacturer-retailer is rather anecdotal than theory-based. The objective of this paper is to bridge the gap in these two types of research and explore the factors which influence on manufacturer's private label production based on two competing theories: S-C-P (Structure - Conduct - Performance) paradigm and resource-based theory. In order to do so, the authors used in-depth interview with marketing managers, reviewed retail press and research and presents the conceptual framework that integrates the major determinants of private labels production. From a manufacturer's perspective, supplying private labels often starts on a strategic basis. When a manufacturer engages in private labels, the manufacturer does not have to spend on advertising, retailer promotions or maintain a dedicated sales force. Moreover, if a manufacturer has weak marketing capabilities, the manufacturer can make use of retailer's marketing capability to produce private labels and lessen its marketing cost and increases its profit margin. Figure 1. is the theoretical framework based on a strategic market management perspective, integrated concept of both S-C-P paradigm and resource-based theory. The model includes one mediate variable, marketing capabilities, and the other moderate variable, competitive intensity. Manufacturer's national brand reputation, firm's marketing investment, and product portfolio, which are hypothesized to positively affected manufacturer's marketing capabilities. Then, marketing capabilities has negatively effected on private label production. Moderating effects of competitive intensity are hypothesized on the relationship between marketing capabilities and private label production. To verify the proposed research model and hypotheses, data were collected from 192 manufacturers (212 responses) who are producing private labels in South Korea. Cronbach's alpha test, explanatory / comfirmatory factor analysis, and correlation analysis were employed to validate hypotheses. The following results were drawing using structural equation modeling and all hypotheses are supported. Findings indicate that manufacturer's private label production is strongly related to its marketing capabilities. Consumer marketing capabilities, in turn, is directly connected with the 3 strategic factors (e.g., marketing investment, manufacturer's national brand reputation, and product portfolio). It is moderated by competitive intensity between marketing capabilities and private label production. In conclusion, this research may be the first study to investigate the reasons manufacturers engage in private labels based on two competing theoretic views, S-C-P paradigm and resource-based theory. The private label phenomenon has received growing attention by marketing scholars. In many industries, private labels represent formidable competition to manufacturer brands and manufacturers have a dilemma with selling to as well as competing with their retailers. The current study suggests key factors when manufacturers consider engaging in private label production.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

The Origin of Changseung and Ongjung Stone (장승의 기원과 옹중석)

  • Chung, Seung Mo
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.1
    • /
    • pp.160-175
    • /
    • 2013
  • There is the need to make a sharp distinction as regards JANGSEUNGs (Korean traditional totem poles) that are different in origin, history and function. This study is to identify the functions of the figures, as well as to trace stone JANGSEUNGs to their origins. In this regard, researched were conducted into the origins of JANGSEUNGs and their changes in history. There was a tradition in the GORYEO Dynasty (an ancient dynasty in the Korean Peninsula) that it erected JANGSAENGs (the archaic name of JANGSEUNGs) or allied stone figures within temples; especially, 'TONGDOSA GUKJANGSAENG SEOKPYO (a stone JANGSAENG that was erected by the royal command and is at the entrance of TONGDO Temple located in YANGSAN, South GYEONGSANG Province, South Korea)' functions as a stone monument rather than as a stone sign. In the engraved inscription, it is written that it should be erected in the form of PANA as before. 'PANA' refers to 'ZHONGKUI', a god in Chinese Taoism believed to exorcise devils that spread diseases. The inscription is to define the territory of TONGDO Temple. The article on HAN JUN GYEOM in a book 'WORAKGI (a travelogue on WORAK Mountain in North CHUNGCHEONG Province, South Korea)' written by HEO MOK makes it possible to guess the scale of GUKJANGSAENGs erected in DOGAP Temple. The stones, on which 'GUKJANGSAENG' or 'HWANGJANGSAENG' were engraved, are not JANGSAENGs but are demarcation posts. In the JOSEON Dynasty (the last dynasty in the Korean Peninsula) JANGSAENGs functioned as signposts. Unlike JANGSAENGs in temples, they were made of wood. At first, the word 'JANGSAENG' was written '長生' in Chinese characters, but in the JOSEON Dynasty another character '木 (wood)' was added to them, and thus the orthography was likely to change into 'JANGSEUNG.' In the JOSEON Dynasty, in addition, optative or geomantic figures were not called 'JANGSEUNG.' Historically, for instance, there has been no case where 'DOL HARBANGs (stone figures found only in JEJU ISLAND, South Korea)' are called 'JANGSEUNG.' In a book 'TAMRA GINYEON (a historical record on JEJU Island, South Korea)' it is written that KIM MONG GYU, JEJU governor, erected ONGJUNG Stones outside the fortress gate. ONGJUNG Stones usually refer to stone statues erected in front of ancient kings or dignitaries' mausoleums. Moreover, they were geomantic figures erected to suppress miasma. A magazine 'GWANGJUEUPJI (a journal on old GWANGJU, South Korea, 1899)' shows that two two ONGJUNG Stones were so erected that they might look at each other to suppress miasma from a pathway through which lucks lose. On the two stone figures located in BUAN-EUP, North JEOLLA Province, South Korea, inscriptions 'SANGWON JUJANGGUN' and 'HAWON DANGJANGGUN' were engraved. The words are to identify the figures' sexes. They are a kind of optative geomantic figures, and therefore there is no reason to call them 'JANGSAENG' or 'JANGSEUNG' or 'DANGSAN.' The words 'SANGWON' and 'HAWON' are closely associated with Taoism. Since then, the words have been widely used as inscriptions on stone figures in temples, and subsequently are used for JANGSEUNGs. A hatted ONGJUNG Stone, found in BUKANSAN Fortress, disappeared and other ones may be being buried somewhere. Meanwhile, ONGJUNG Stones in JEJU Island and stone figures in BUAN-EUP have hardly been displaced and thus have properly functioned. Stone figures, made in those days, seem to be most similar in function to JANGSAENGs made during the GORYEO Dynasty. Specifically, like earlier JANGSAENGs, stone figures made during the early to mid-18th century were likely to function not only as optative figures but as boundary stones. Most of stone figures in temples were made whenever the land use survey was conducted throughout the nation, but given that at the same period of time, the commonalty filed many lawsuits against grave sites, temples might erect many stone figures to mark their territories. Currently, wooden or stone figures are commonly called 'JANGSEUNG', but they were erected in different epochs and for different reasons. Their origins are to be sought in stone figures that functioned not only as optative figures in temples but as boundary stones during the GORYEO Dynasty.

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

A Study on Developing Customized Bolus using 3D Printers (3D 프린터를 이용한 Customized Bolus 제작에 관한 연구)

  • Jung, Sang Min;Yang, Jin Ho;Lee, Seung Hyun;Kim, Jin Uk;Yeom, Du Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.61-71
    • /
    • 2015
  • Purpose : 3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. Materials and Methods : RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$ and $V_{95%}$ in treatment plan through Eclipse. Results : Customized bolus production period took about 3 days. The total volume of air gap was average $3.9cm^3$ at the customized bolus. And it was average $29.6cm^3$ at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. Conclusion : The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against the treatment area with irregular surface. However, the air gap between branded bolus and skin was not enough to cause a change in target dose. On the other hand, in the chest wall could confirm that dose decrease for small the air gap. Customized bolus production period took about 3 days and the development cost was quite expensive. Therefore, the commercialization of customized bolus developed by 3D printers requires low-cost 3D printer materials, adequate for the use of bolus.

  • PDF