• 제목/요약/키워드: Chang-Ki(張機)

검색결과 419건 처리시간 0.029초

하수열원 열펌프 시스템의 성능 시뮬레이션 (A Characteristics Simulation of Heat Pump System for Sewage Water as a Heat Source)

  • 박일환;장기창;이영수;윤형기;백영진
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.280-286
    • /
    • 2008
  • In this study, characteristics simulation of heat pump system is investigated for heating and cooling using sewage water as a heat source. A simulation program for preestimate operation characteristics of heat pump system is developed. The performance of this system is resolved by several variables and the characteristics which is based on actual air and sewage temperature data. The simulation results agree well with the experimental values of COP. In the analysis of system characteristics, the COP is changed between $3\sim5$ in winter season for heating load, $4\sim6$ in summer season for cooling load. As the results of Life Cycle Cost analysis over a 15 year life cycle, the energy cost could be reduced by 250 million won if a heat pump system was used instead of a conventional boiler and an absorbtion refrigerator on the office building.

지열발전을 위한 칼리나 사이클의 시뮬레이션 (Simulation of the Kalina cycle for a Geothermal Power Generation)

  • 백영진;김민성;장기창;이영수;박성룡;라호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.782-787
    • /
    • 2008
  • The Kalina cycle simulation study was carried out for a preliminary design of a geothermal power generation system. The Kalina cycle system can be used for the utilization of a low-temperature heat sources such as geothermal and industrial waste heat that are not hot enough to produce steam. The sea/river water can be considered as a cooling media. A steady-state simulation model was developed to analyze and optimize its performance. The model contains a turbine, a pump, an expansion valve and heat exchangers. The turbine and pump were modelled by an isentropic efficiency, while a condenser, an evaporator and a regenerative heat exchanger were modeled by UA-LMTD method with a counter-flow assumption. The simulation results show that the power generation efficiency over 10% is expected when a heat source and sink inlet temperatures are $100^{\circ}C$ and $10^{\circ}C$ respectively.

  • PDF

계면활성제에 의한 난류 관내 유동의 마찰감소 현상 (Drag Reduction Phenomena of Surfactant Turbulent Pipe Flows)

  • 윤형기;신광호;장기창;나호상;유성연
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.1025-1032
    • /
    • 2006
  • This is to characterize the fluid mechanics of surfactant water solutions, which exhibit drag reduction in the turbulent flow as compared to pure water. The emphasis is placed on those fluid characteristic aspects of drag reducing solutions which are relevant for application in closed circulation loops for the purpose of pumping power savings, like hydronic cooling and heating systems in buildings. The experiments are carried out with the solutions of the surfactant Beraid DR-IW 616 in concentration of $100{\sim}3,000ppm$. The following key parameters are focused in this study: surfactant concentration, solution temperature and pipe diameter.

무선 전자식 장비를 이용한 지중열전도도 측정 기술 (Ground Thermal Conductivity Test with A Wireless Probe)

  • 김지영;이의준;장기창;강은철;고건혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2381-2384
    • /
    • 2008
  • The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic Response Test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless probe for hi-speed k determination was introduced in this paper. This technique using a wireless probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. As a result, the electronic wireless probe can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of local heat flow, etc.

  • PDF

유한한 열용량의 열원 및 열침 조건에서 열기관의 출력 극대화 (Power Maximization of a Heat Engine Between the Heat Source and Sink with Finite Heat Capacity Rates)

  • 백영진;김민성;장기창;이영수;라호상
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.556-561
    • /
    • 2011
  • In this study, the theoretical maximum power of a heat engine was investigated by sequential Carnot cycle model, for a low-grade heat source of about $100^{\circ}C$. In contrast to conventional approaches, the pattern search algorithm was employed to optimize the two design variables to maximize power. Variations of the maximum power and the optimum values of design variables were investigated for a wide range of UA(overall heat transfer conductance) change. The results show that maximizing heat source utilization does not always maximize power.

중고온 히트파이프를 이용한 열회수기술에 관한 연구 (Technology of Waste Heat Recovery Using Heat Pipe Heat Exchanger for Industrial Practice)

  • 이영수;김종률;장기창;백영진
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1044-1050
    • /
    • 2004
  • The present study has been conducted to develop a heat pipe heat exchanger for middle-high temperature ranged from 300 to $600^{\circ}C$. Heat transfer rate, overall heat transfer coefficient and temperature effectiveness were investigated using a heat pipe heat exchanger with Dowtherm A as working fluid. Theoretical analysis was also conducted, and the followings were obtained: (1) Heat exchange rate increased as waste gas temperature supplied to evaporator and frontal velocity in condenser increased, (2) Overall heat transfer coefficient increased by $3{\sim}7\%$ as frontal velocity in evaporator and condenser increased, (3) Temperature effectiveness was about $30\%$ in evaporator and was about $40\%$ in condenser, (4) Heat recovery rate was about $38\%$, (5) Pressure drop did not exceed $8\;mmH_{2}O$ under the running condition of $1{\sim}3Nm/s$, (6) Simulation results were corresponded with experimental results.

제주지역 연구소 건물의 해수열원 냉난방시스템 적용 및 평가 (The Application and Evaluation of Heating and Cooling System by Seawater Heat Source for Research Center Building in Jeju)

  • 박진영;김삼열;장기창
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.26-31
    • /
    • 2013
  • Use of heat from seawater could be different from the weather conditions of a coastal city and seawater temperatures near the city. It will be a good option to use surface layer water with Heat Pump system for using seawater cooling/heating in Jeju. The study investigates the proper depth for seawater heat gain of Jeju area in Korea. Sampling points are 0, 10, 20, 30m from the surface of the Sea. Seawater temperature does not change significantly according to the depth in winter, while the temperature is quite different according to the depth in summer. In this study, it is analyzed to compare existing system and seawater heat source system for target buildings on Jeju. And this systems are calculated a initial cost.

제주 지역의 해수열원 지역냉난방 시스템 적용을 위한 건축물 용도별 냉난방 부하량 분석 및 적용방안 (Application of Load by Purpose of Buildings for Application of Seawater District Cooling and Heating System in Jeju Area)

  • 박진영;박재홍;김삼열;장기창
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.86-90
    • /
    • 2014
  • It is important to select an optimal capacity for equipment, because the initial cost of new and renewable energy system is more expensive than that of exiting system. An optimal equipment and enhanced rate of operation can be selected, to analyze the cooling and heating load of buildings. In this study, seawater heat pump system in the Jeju area will be applied, by the heat source equipment of district heating. The loads of buildings are analyzed from existing researches, to select optimal capacity of equipment. Also, an optimal rate of building use will be set up, from a combination of buildings.

LCC 분석에 의한 하천수 미활용에너지 이용시스템의 경제성 평가 (Life-Cycle Analysis of the River Water Unutilized Energy System)

  • 박일환;윤형기;장기창;박준택;박성룡
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.596-604
    • /
    • 2005
  • This paper presents the work on evaluating the LCC (Life-Cycle Cost) of a heat pump system as unutilized energy system. The river water as an unutilized energy source was used for the heat source of heat pump system. LCC analysis is a concrete method for evaluating the economical efficiency of energy facilities of building. The present case study shows an example of adequate use of the LCC analysis on a heat pump system and conventional gas boiler and refrigerator for building heat supply. A life cycle of 20 years was used to calculated net present value of energy cost. Over a 20 year life cycle, the energy cost could be reduced by 612 million won if a heat pump system were used instead of a conventional boiler and an absorption refrigerator.

국내 하천수 미활용에너지 부존량에 관한 조사연구 (A Study on the Potential Energy Reserve Amount of Domestic River Water as Unutilized Energy Resource)

  • 박일환;윤형기;박준택;장기창;이영수
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.521-528
    • /
    • 2005
  • This study has been conducted to investigate the potential energy reserve amount of river water as energy resource with useful temperature difference. Since the river water temperature is one of the primary parameters deciding the potential amount of river water energy reserve amount, the climate change effects on it are critically important. In this study, the heat exchange processes and the inter-relationship between the air temperature and river water temperature have been theoretically analyzed. Based on the present study, the potential energy reserve of river water is calculated to amount to 192,000 Tcal/year. Among this, it is estimated that approximately 2,000 Tcal/year can be directly utilized for heat pump energy sources.