• Title/Summary/Keyword: Chamfer

Search Result 152, Processing Time 0.022 seconds

A new manufacturing method of all ceramic restoration using alumina tape and presentation of clinical cases

  • Oh, Nam-Sik;Kim, Eui-Seong;Lee, Keun-Woo;Han, Jung-Suk;Kim, Dae-Joon;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.800-805
    • /
    • 2000
  • In an effort to facilitate fabrication procedure of all ceramic crowns, a novel preparation method for all ceramic crown using alumina tape was developed. The alumina tape having a uniform thickness was cast by using Doctor blade method. The physical properties of newly introduced alumina tape has biaxial flexure strength of $500\sim600MPa$. The value of toughness is $3.18\sim3,28MPa.m^{1/2}$ which corelates with fracture and the linear shrinkage rate of the alumina tape is 0.44% during core production. The marginal fitness of the alumina tape all-ceramic restoration with $90{!`}$shoulder margin had average marginal discrepancy at $78.3{\S}$ > and average marginal gap at $44.4{\S}$ >. At the marginal preparation of $135{!`}$deep chamfer, the average marginal discrepancy at $82.1{\S}$ > and the average marginal gap at $40.2{\S}$ > had been reported. This fabrication procedure of all ceramic crowns with alumina tapes is easier and less technical sensitive for dental technicians. After restoration with new all ceramic crowns we followed the patients 2 years later, there were no complications as porcelain fractures or periodontal disease. We had good esthetic clinical results with new all ceramic crowns.

  • PDF

Photoelastic Stress Analysis of Proximal Margins in Dental Restorations (치관보철물(齒冠補綴物)의 인접변연부위(隣接邊緣部位)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析))

  • Lim, Chung-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 1980
  • The purpose of this study was to investigate the stresses in different proximal margins and to measure, quantitatively, the effect of different modifications in the design of preparations on the stresses using two-dimensional photoelasticity. Photoelastic stress analysis is based on the phenomenon, exhibited by most transparent solids, of becoming birefringent, or doubly refracting, when strained. Two birefringent materials were used in this study, PSM-1 and PSM-5 in .standard sheet ($10'{\times}10'{\times}\frac{1}{4}'$ thickness), PSM-1(polyester) was used for constructing the substructure, and PSM-5(epoxy resin) was used in making the restorations to be investigated. Two birefringent materials were used in the construction of composite photoelastic model. Seven variable models were constructed. The peripheral dimensions of all model were constant and the models represent an occlusomesial section of a lower posterior molar. Model 1 represents the knife edge margin (shoulderless), Model 2 represents the chamfer, Model 3 represents a rounded shoulder(no sharp angle between the axial wall and gingival floor), Model 4 represents a flat shoulder (axial wall is a $90^{\circ}$ angle to the gingival wall), Model 5 represents $+15^{\circ}$ angulation, Model 6 has a $-15^{\circ}$ angulation, and Model 7 is the same as Model 4 except that it has a $45^{\circ}$ bevel. Improved artificial stone was used to represent dental cement in luting the composite photoelastic model. Static loading procedures(100 pounds) were used at preplanned sites. The results were as follows; 1. The stresses in the proximal portion of all tested models were compressive in nature when the proximal shoulders were loaded vertically on the same proximal marginal ridge. 2. The round and chamfered preparations were the optimum designs in proximoocclusal restorations. They showed the lowest stress concentration factor, i.e. 2.16 and 2.23, respectively. The knife edged shoulder had the highest value, K=5.39. Round type shoulder geometry experiments reduced the stress concentration factor (S.C.F.) 3. The gingival portion of proximal shoulder geometry was a critical location for stress concentration.

  • PDF

Automatic Lung Registration using Local Distance Propagation (지역적 거리전파를 이용한 자동 폐 정합)

  • Lee Jeongjin;Hong Helen;Shin Yeong Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.1
    • /
    • pp.41-49
    • /
    • 2005
  • In this Paper, we Propose an automatic lung registration technique using local distance propagation for correcting the difference between two temporal images by a patient's movement in abdomen CT image obtained from the same patient to be taken at different time. The proposed method is composed of three steps. First, lung boundaries of two temporal volumes are extracted, and optimal bounding volumes including a lung are initially registered. Second, 3D distance map is generated from lung boundaries in the initially taken volume data by local distance propagation. Third, two images are registered where the distance between two surfaces is minimized by selective distance measure. In the experiment, we evaluate a speed and robustness using three patients' data by comparing chamfer-matching registration. Our proposed method shows that two volumes can be registered at optimal location rapidly. and robustly using selective distance measure on locally propagated 3D distance map.

Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time (세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가)

  • Ji-Hyeon Bae;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

Development of a Brain Phantom for Multimodal Image Registration in Radiotherapy Treatment Planning

  • H. S. Jin;T. S. Suh;R. H. Juh;J. Y. Song;C. B. Y. Choe;Lee, H .G.;C. Kwark
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.450-453
    • /
    • 2002
  • In radiotherapy treatment planning, it is critical to deliver the radiation dose to tumor and protect surrounding normal tissue. Recent developments in functional imaging and radiotherapy treatment technology have been raising chances to control tumor saving normal tissues. A brain phantom which could be used for image registration technique of CT-MR and CT-SPECT images using surface matching was developed. The brain phantom was specially designed to obtain imaging dataset of CT, MR, and SPECT. The phantom had an external frame with 4 N-shaped pipes filled with acryl rods, Pb rods for CT, MR, and SPECT imaging, respectively. 8 acrylic pipes were inserted into the empty space of the brain phantom to be imaged for geometric evaluation of the matching. For an optimization algorithm of image registration, we used Downhill simplex algorithm suggested as a fast surface matching algorithm. Accuracy of image fusion was assessed by the comparison between the center points of the section of N-shaped bars in the external frame and the inserted pipes of the phantom and minimized cost functions of the optimization algorithm. Technique with partially transparent, mixed images using color on gray was used for visual assessment of the image registration process. The errors of image registration of CT-MR and CT-SPECT were within 2mm and 4mm, respectively. Since these errors were considered within a reasonable margin from the phantom study, the phantom is expected to be used for conventional image registration between multimodal image datasets..

  • PDF

Influence of the accuracy of abutment tooth preparation on the marginal adaptation of Co-Cr alloy copings fabricated with a selective laser sintering technology (지대치삭제의정확도가레이져신터링기술로제작된Co-Cr 코핑의변연적합도에미치는영향)

  • Kim, Seo-Rahng;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.337-344
    • /
    • 2015
  • Purpose: The purpose of present study is to examine the correlation between the accuracy of abutment preparation and the marginal adaptation of metal coping. With this view, this study compared the correlations regard to the three different manufacturing methods of selective laser sintering technique, milling and casting. Materials and methods: Two master models were made in a different way. First model with deep chamfer margin was prepared directly by a general clinician and the second model was designed by 3-D designing software program with the same abutment preparation principle and produced by computer aided manufacturing. 12 Co-Cr alloy copings were produced respectively with three different method; SLS system, CAD/CAM milling and conventional lost wax technique from each master model. The total 72 copings fully sit on the master model were stereoscopically evaluated at 40 points along the entire circumferential margin. Results: Significant differences in the absolute marginal discrepancies of Co- Cr copings from SLS system (P=.0231) and casting method (P<.0001) were shown between hand preparation model and computer designed model. However, no significant difference was found between the two model groups from milling method (P=.9962). Conclusion: Within the limitation of this study, the effect of the accuracy of abutment preparation on the marginal adaptation of Co-Cr coping is statistically significant in SLS system and casting group. The copings produced by SLS system exhibited the lowest marginal discrepancies among all groups, and the marginal gap of this method group was influenced by the accuracy of the abutment preparation.

A Study of the Comparison of Microleakage according to the Types of Cement on the Cast Post and Core (주조 포스트코아에서 시멘트 종류가 미세누출에 미치는 영향)

  • Nam, Ki-Young;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • The purpose of this study was to compare the microleakage at the interface of cast post and tooth according to the type of cement. Forty anterior teeth with single root were used. The teeth were cut 2 mm coronal from the cementoeamel junction and chamfer finish line was made on 1 mm coronal from the cementoeamel junction. After the routine endodontic treatment, post space was prepared using #5.5 Parapost drill to a depth of 7 mm. After the pick up impression, core building was made to 3 mm of clinical crown with burnout wax, then post and core was cast with nonprecious metal. The teeth were divided into four groups of ten each. In Group I, post and core were cemented with Fleck's(Zinc phosphate cement) In Group II, post and core were cemented with Fuji I(Glass ionomer cement) In Group III, post and core were cemented with Superbond C & B(Composite resin cement) In Group IV, post and core were cemented with Panavia 21(Composite resin cement) All cemented teeth were stored in normal saline at $37^{\circ}C$ for 7 days and thermocycled from $5^{\circ}C$ to $55^{\circ}C$ for 500 cycles with a dwell time of 30 seconds. After thermocycling, teeth were immersed in 1% Basic fuchsin dye for 48 hours. All 40 teeth were then embedded in the epoxy resin and cut buccolingually with a cutting instrument. The degree of penetration of dye at interface was graded on a scale of 0 to 4 using a stereomicroscope at 25 to 40 times magnification. Through the findings of this study, the following conclusion were obtained. 1. All the groups showed the microleakage at the interface of cast post core and tooth. 2. Group I showed the highest microleakage score among the groups with a significant difference(p<0.05). 3. Group II showed higher microleakage score than Group III and Group IV with a significant difference(p<0.05). 4. Group IV showed the lowest microleakage score but there were no significant difference with Group III(p>0.05).

  • PDF

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.

Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations (두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교)

  • Shin, Ho-Sik;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.528-534
    • /
    • 2008
  • Purpose: Marginal fit is one of the important components for the successful prosthodontic restoration. Poor fitting margin of the restoration causes hypersensitivity, secondary caries, and plaque accumulation, which later result in prosthodontic failure. CAD/CAM zirconia all-ceramic restorations, such as $LAVA^{(R)}$ (3M ESPE, St.Paul, MN) and $EVEREST^{(R)}$ (KaVo Dental GmbH, Biberach, Germany) systems were recently introduced in Korea. It is clinically meaningful to evaluate the changes of the marginal fit of the CAD/CAM zirconia systems before and after build-up. The purposes of this study are to compare the marginal fit of the two CAD/CAM all-ceramic systems with that of the ceramometal restoration, before and after porcelain build-up Material and methods: A maxillary first premolar dentiform tooth was prepared with 2.0 mm occlusal reduction, 1.0 mm axial reduction, chamfer margin, and 6 degree taperness in the axial wall. The prepared dentiform die was duplicated into the metal abutment die. The metal die was placed in the dental study model, and the full arch impressions of the model were made. Twenty four copings of 3 groups which were $LAVA^{(R)}$, $EVEREST^{(R)}$, and ceramometal restorations were fabricated. Each coping was cemented on the metal die with color-mixed Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan). The marginal opening of each coping was measured with $Microhiscope^{(R)}$ system (HIROX KH-1000 ING-Plus, Seoul, Korea. X300 magnification). After porcelain build-up, the marginal openings of $LAVA^{(R)}$, $EVEREST^{(R)}$,and ceramometal restorations were also evaluated in the same method. Statistical analysis was done with paired t-test and one-way ANOVA test. Results: In coping states, the mean marginal opening for $EVEREST^{(R)}$ restorations was $52.00{\pm}11.94\;{\mu}m$ for $LAVA^{(R)}$ restorations $56.97{\pm}10.00\;{\mu}m$, and for ceramometal restorations $97.38{\pm}18.54\;{\mu}m$. After porcelain build-up, the mean marginal opening for $EVEREST^{(R)}$ restorations was $61.69{\pm}19.33\;{\mu}m$, for $LAVA^{(R)}$ restorations $70.81{\pm}12.99\;{\mu}m$, and for ceramometal restorations $1115.25{\pm}23.86\;{\mu}m$. Conclusion: 1. $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations in comparison with ceramometal restorations showed better marginal fit, which had significant differences (P < 0.05) in coping state and also after porcelain build-up . 2. The mean marginal opening values between $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations did not showed significant differences after porcelain build-up as well as in coping state (P > .05). 3. $EVEREST^{(R)}$, $LAVA^{(R)}$ and ceramometal restorations showed a little increased marginal opening after porcelain build-up, but did not show any statistical significance (P > .05).