• 제목/요약/키워드: Ceramic-pressed-to-metal restoration

검색결과 6건 처리시간 0.023초

Fabricating a Ceramic-Pressed-to-Metal Restoration with Computer-Aided Design, Computer-Aided Manufacturing and Selective Laser Sintering: A Case Report

  • Lee, Ju-Hyoung;Kim, Hyung Gyun
    • Journal of Korean Dental Science
    • /
    • 제8권1호
    • /
    • pp.41-47
    • /
    • 2015
  • Even though a conventional metal ceramic restoration is widely in use, its laboratory procedure is still technique-sensitive, complex, and time-consuming. A ceramic-pressed-to-metal restoration (PTM) can be a reliable alternative. However, simplified laboratory procedure for a PTM is still necessary. The article is to propose a technique that reduces time and effort to fabricate a PTM with the aid of computer-aided design, computer-aided manufacturing and selective laser sintering technologies.

열-가압을 이용한 금속 도재관과 전통적인 금속 도재관의 변연 적합도 비교 연구 (Comparative study in marginal fit of a pressed ceramic and feldspathic porcelain fused to metal restoration)

  • 김윤영;박윈희;유동엽;이영수
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.273-279
    • /
    • 2010
  • 연구 목적: 본 연구의 목적은 전통적인 금속 도재관과 열-가압을 이용한 금속-도재관의 변연 적합도를 비교하는 것이다. 연구 재료 및 방법: 상악 제1소구치 레진 치아를 교합면 2.0 mm, 협, 설면과 인접면을 1.0 mm 두께로 삭제하였으며, 변연 형태는 chamfer margin으로 그리고 축면 경사는 6도 taper로 삭제하였다. 삭제한 레진치를 복제하여 금속 다이 20개를 제작하였고, 이 금속 다이를 인상 채득하여 작업을 위한 석고 다이를 제작하였다. 금속 도재관과 $PoM^{(R)}$ 시스템 (Ivoclar vivadent., Liechtenstein)의 두 그룹으로 나누어 금속 코핑을 각각 10개씩 총 20개를 제작하였으며, 광학 현미경을 이용하여 변연 간격을 측정하였다. 도재 축성 후, 위와 동일한 방법으로 변연 간격을 측정하였다. 통계 처리는 Wilcoxon Signed Ranks test와 Mann Whitney U test를 이용하여 분석하였다. 결과: 본 연구의 결과는 다음과 같다. 1. 금속 도재관은 코핑 상태 ($64.93{\pm}12.48\;{\mu}m$)와 도재 축성 후 ($63.43{\pm}12.86\;{\mu}m$)의 변연 간격에 유의성 있는 차이를 보이지 않았다. 2. $PoM^{(R)}$ 시스템은 코핑 상태 ($50.00{\pm}12.28\;{\mu}m$)와도재축성후($56.72{\pm}13.80\;{\mu}m$)의 변연 간격에 유의성 있는 차이를 보이지 않았다. 3. 금속 도재관과 $PoM^{(R)}$ 시스템 변연 간격은 유의성 있는 차이를 보이지 않았다. 결론: $PoM^{(R)}$시스템은 왁스 소결법을 이용해 변화가 적은 기술적인 이점이 있으며, 세밀한 기술을 요구하는 축성 방법과는 대조적으로 왁스 성형으로 도재의 완전한 형태를 만들 수 있는 편리함을 제공하는 장점을 가진다. 본 연구 결과와 이런 장점을 토대로 앞으로 임상적 사용을 고려해 볼 수 있을 것으로 사료된다.

Fabrication of a metal-ceramic crown to fit an existing partial removable dental prosthesis using ceramic pressed to metal technique: a clinical report

  • Seo, Jae-Min;Ahn, Seung-Geun
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.241-244
    • /
    • 2014
  • Fabricating a crown to retrofit an existing abutment tooth for a partial removable dental prosthesis (PRDP) is one of the most time-consuming and labor-intensive clinical procedures. In particular, when the patient is concerned with esthetic aspects of restoration, the task of fabricating becomes more daunting. Many techniques for the fabrication of all-metallic or metal-ceramic crowns have been discussed in the literature. This article was aimed to describe a simple fabrication method in which a retrofitting crown was fabricated for a precise fit using a ceramic-pressed-to-metal system.

Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례 (Full-mouth rehabilitation with pressed ceramic technique using provisional restorations)

  • 노현식;우이형;배아란
    • 대한치과보철학회지
    • /
    • 제51권1호
    • /
    • pp.47-51
    • /
    • 2013
  • 골유착성 임플란트의 등장으로 결손치의 수복이 가능하게 되어 전통적인 고정성 또는 가철성 국소의치가 임플란트로 대체되어가고 있는 추세이다. 특히 젊은 환자의 경우 보철물의 수명과 함께 심미적인 결과를 고려해야 한다. 임플란트는 장기간의 성공적인 치료 결과와 함께 기능적인 회복을 이룰 수 있으나, 치은 퇴축으로 인한 변연부 노출, 치간 유두 상실로 인한 비심미적인 연조직, 금속 지대주, 상부 도재관의 투명도 감소 등은 임플란트 수복 시 정상적인 저작 기능 회복은 이룰 수 있으나 심미적으로는 불리한 결과를 보일 수 있다. 최근 CAD/CAM technology를 이용한 지르코니아는 충분한 강도와 파절 저항성을 가져 정상적인 저작 기능이 가능하고, 뛰어난 굴곡강도로 고정성 보철물, 가철성 의치 보철물에 다양하게 응용되며, 생체 적합성이 뛰어나고, 색조 재현성에서도 금속에 비해 심미적인 결과를 보이며 전치부와 구치부의 보철 치료에 이용되고 있다. 그리고 pressed ceramic technique을 이용한 전부 도재 보철 수복은 기존의 전통적인 도재 축성 과정보다 우수한 파절 저항성을 보인다. Pressed ceramic technique 은 상부의 도재 축성 과정이 왁스업을 통해 용융, 주조 되어 최종 보철물의 형태를 왁스업 단계에서 조절할 수 있는 장점이 있다. 임플란트를 포함한 본 증례의 보철 수복은 임시 보철물의 치경부 형태를 조절하여 심미적인 연조직을 재현하고자 하였고, 임시 보철물의 형태를 왁스업으로 복제하여 원하는 형태의 최종 보철물을 제작하였다. 본 증례에서는 임플란트 치료에 있어서 지르코니아와 pressed ceramic technique을 적용하여 기능적이고 심미적으로 양호한 결과를 얻었다.

IPS-Empress system을 이용한 상악 중절치의 치관복제술 (Crown Duplication Technique of Upper Central Incisor using IPS-Empress system)

  • 오상천;신영호
    • 구강회복응용과학지
    • /
    • 제22권3호
    • /
    • pp.243-250
    • /
    • 2006
  • Due to high esthetic demands from patients, we are driven to fabricate natural-looking(form and color) restorations. In the past decade, the glass-ceramic in dentistry has been used as a material with variable crystals that affects the appearance, characteristics, and mechanical properties of metal-free fixed restoration. The conventional IPS Empress glass-ceramic is a heat-pressed, leucite reinforced material using the "lost wax" principle. This glass-ceramic has been successfully used for esthetic restorations such as all-ceramic crowns, inlays/onlays, and veneers for about 15 years. This article presents that the form and surface texture of clinical crown are duplicated by IPS-Empress system using "lost-wax technique".

수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향 (INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS)

  • 복원미;최근배;박찬운;안승근
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.