• Title/Summary/Keyword: Ceramic-glass

Search Result 1,315, Processing Time 0.025 seconds

A Study on the Colored Glass Plaster Resist Printing Technique Experiment and the Porcelain Vase Fusion with the Motif of Leaf (나뭇잎을 모티브로 한 색유리 플래스터 방염기법 실험과 도자화병 융합에 관한 연구)

  • Kim, Seung-Man;Lee, Jung-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.4
    • /
    • pp.663-674
    • /
    • 2019
  • The background of the study is to experiment with the color glass plaster technique and the resist printing technique which are newly developed with the motif of natural leaves, and to make an interior vase added with new and unique decoration by fusing with ceramic vases. First research and development method is to describe the color glass plaster technique. Second is to explain the resist printing technique and study the decoration method. Third is to examine the history and kinds of vase. And lastly, it is to design 16 vases contemporarily, and use the leaves to experiment with oxidation and reduction of white porcelain and celadon. This experiment acquired the unique color expression by yaobian, and the soft, warm brown resist printing gradation was formed around the leaves. It will get good effects and results by expanding and applying the unique experiment effects to living interior porcelain, molding porcelain, and industrial porcelain.

Accelerated testing for evaluating bubble quality within quartz glass crucibles used for manufacturing silicon single crystal ingots (실리콘 단결정 잉곳 제조용 석영유리 도가니 내 기포 품질평가를 위한 가속시험)

  • Gyu Bin Lee;Seung Min Kang;Jae Ho Choi;Young Min Byeon;Hyeong-Jun Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.91-96
    • /
    • 2023
  • To verify the quality of bubbles during the use of quartz glass crucibles (QC), an appropriate accelerated testing method was proposed. The bubble state of discarded waste crucibles obtained from actual Czochralski (Cz) processes was analyzed, and optimal heat treatment conditions were suggested by varying temperature, pressure, and time using the QC test piece. By subjecting the samples to heat treatment at 1450℃, 0.4 Torr, and 40 hours, it was possible to control the bubble size and density to a similar level as those generated in the actual Cz process. In particular, by selecting a relatively lower pressure of 0.4 Torr compared to the typical range of 10~20 Torr applied in the Cz process, the time required for accelerated bubble formation testing could be reduced. However, it was determined that increasing the heat treatment temperature to 1550℃ led to the phenomenon of Ostwald ripening, resulting in larger bubbles and a rapid decrease in density. Therefore, it was concluded that it was not a suitable condition for the desired b ake test.

Preparation of lightweight fireproofing concrete with high impact strength (고 충격강도의 경량 내열 내화 콘크리트 제조)

  • Seok Ju Jeong;Joo Eun Kim;Seo Lin Jeong;Byeong Woo Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.5
    • /
    • pp.181-186
    • /
    • 2024
  • In order to solve the problems of low strength and brittle fracture of conventional concretes, ordinary cement was used as the main material of concrete binder, and porous glass beads processed from waste glass were used as aggregates to provide lightweight and fireproof insulation, and functional organic binding additives (including polymers) were added to improve concrete strength. Additional binding agents, such as silanes, were used to produce concrete-type lightweight materials with a specific gravity lower than water. The resulting materials thus manufactured have solved the problems of low work-ability and brittle fracture of conventional (ceramic) concretes, and exhibited excellent mechanical and thermal properties, with good fireproofing properties and low thermal conductivity at high temperatures. In addition, it can be molded into a certain space like conventional concrete, processed into bricks or thin boards in molds, or applied like paints, so it is believed that it can be applied to various structural materials.

Effect of Potassium Oxide on the Early Hydration of Tricalciumaluminate (Tricalciumaluminate의 초기 수화반응에 미치는 $K_2O$의 영향)

  • Han, Ki-Sung;Choi, Man;Seo, Il-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.19 no.2
    • /
    • pp.133-138
    • /
    • 1982
  • Two kinds of clinker liquid melts, one containing 2.0% of $K_2O$ and the other without $K_2O$, were prepared with the similar composition as those developed during the firing of portland cement clinker. One portion of melt was quenched and found to consist of glass together with traces of proto-$C_3A$, and the other portion was allowed to cool spontaneously to crystallize $C_3A$ and calciumferrite well. The product obtained by crystallization of the melt without $K_2O$showed cubic $C_3A$, while orthorhombic $C_3A$ was formed from the crystallized product containing $K_2O$. Studies on the hydration behavior of the samples made from the melts with 30% of gypsum were carried out for 24 hours by observation at regular intervals ettringite, monosulphate hydrates and gypsum which were formed or consumed during hydration. The samples without $K_2O$ in the melts were hydrated wth addition of proper amount of $K_2SO_4$ in the water for hydration. Hydration behavior of glassified $C_3A$ showed that it has low reactivity relative to crystallized $C_3A$, and also hydration reactivity of orthorhombic $C_3A$ was much lower than that of cubic $C_3A$ in 60 minutes. Potassium sulphate in the solution reduced the hydration reactivity of $C_3A$ . Evolution peaks of hydration heat examined by twin-type conduction micro-calorimeter showed that glassified $C_3A$ without $K_2O$ had secondary peak after 9 hours and $C_3A$ containing $K_2O$ after 12 hours. When crystallized $C_3A$ was hydrated, initial peaks of hydration heat were considerably high and there was no secondary peak for cubic $C_3A$ but the secondary peak of orthorhombic $C_3A$ appeared after 4 hours.

  • PDF

Fracture resistance of endodontically treated canines restored with different sizes of fiber post and all-ceramic crowns

  • Turker, Sebnem Begum;Alkumru, Hasan Necdet;Akalin, Buket
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.158-166
    • /
    • 2016
  • PURPOSE. The aim of this study was to determine the fracture resistance and the mode of fracture of endodontically treated teeth restored with different fiber posts and all-ceramic crowns. MATERIALS AND METHODS. Two glass fiber reinforced post systems in two different sizes and polyethylene fiber ribbon in two different thicknesses (n=10) were used. The specimens, restored with all-ceramic crowns, were subjected to a compressive load (in N) delivered at a 130-degree angle to the long axis until a fracture could be noted. The results were analyzed statistically with a One-Way ANOVA test (P<.05). RESULTS. Statistically significant differences were observed between the mean fracture resistance values of Postec, Snowlight, and Kerr Connect thin specimens (P<.0095). The Postec results (395.70 N) were found to be significantly higher than the others. No statistical difference was observed among the thick specimens (P<.2657). The mean fracture resistance values of the Snowlight thick samples were found to be higher than those of the Snowlight thin samples. The specimens were always fractured around the cemento-enamel junction at the palatinal side. No post fracture was observed for the thin Snowlight and Kerr Connect specimens or for the thick Postec and Kerr Connect specimens. Among the common failure types of the specimens, the worst was observed to be the root fracture failure. The highest post dislodgement failure result (80%) was obtained from the thin Kerr Connect specimen. CONCLUSION. In terms of optimizing fracture resistance, the fiber post size selection should be done according to the forces applied to the restored teeth.

Preparation of High-Transmittance Glass Thin Films by the Sol-Gel Process (졸-겔법을 이용한 고투과율 유리 박막의 제조)

  • Hwang, Kyuseog;Song, Jongeun;Lee, Hyungmin;Lim, Yongmu;Kim, Sangmoon;Shim, Moonsik;Yun, Yeomhum
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.45-49
    • /
    • 1999
  • To prepare high-transmittance films, thin films were fabricated on the microscope slide glasses with silicon alkoxides and boric acids as starting materials by using a dip-coating technique. Thicknesses of the thin films were controled as viscosity of the sol used and composition of the $B_2O_3$ was changed at 5, 10, 15 and 20 mol%. Transmittance at visible range and IR transmittance of the films according to the composition were measured, and refractive index of the films were analyzed also. Maximum transmittance at visible range and minimum refractive index were obtained at 15 mol% $B_2O_3$. We will discuss a decrease of the transmittance at 20 mol% on the basis of the refractive index.

  • PDF

Repair bond strength of resin composite to bilayer dental ceramics

  • Ataol, Ayse Seda;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.101-112
    • /
    • 2018
  • PURPOSE. The purpose of this study was to investigate the effect of various surface treatments (ST) on the shear bond strength of resin composite to three bilayer dental ceramics made by CAD/CAM and two veneering ceramics. MATERIALS AND METHODS. Three different bilayer dental ceramics and two different veneering ceramics were used (Group A: IPS e.max CAD+IPS e.max Ceram; Group B: IPS e.max ZirCAD+IPS e.max Ceram, Group C: Vita Suprinity+Vita VM11; Group D: IPS e.max Ceram; Group E: Vita VM11). All groups were divided into eight subgroups according to the ST. Then, all test specimens were repaired with a nano hybrid resin composite. Half of the test specimens were subjected to thermocycling procedure and the other half was stored in distilled water at $37^{\circ}C$. Shear bond strength tests for all test specimens were carried out with a universal testing machine. RESULTS. There were statistically significant differences among the tested surface treatments within the all tested fracture types (P<.005). HF etching showed higher bond strength values in Groups A, C, D, and E than the other tested ST. However, bonding durability of all the surface-treated groups were similar after thermocycling (P>.00125). CONCLUSION. This study revealed that HF etching for glass ceramics and sandblasting for zirconia ceramics were adequate for repair of all ceramic restorations. The effect of ceramic type exposed on the fracture area was not significant on the repair bond strength of resin composites to different ceramic types.

Relationship between Ionic Conductivity and Composition of Li2O-ZrO2-SiO2 Glasses Determined from Mixture Design (혼합물계획법에 의한 Li2O-ZrO2-SiO2 유리의 이온전도도와 조성의 관계)

  • Kang, Eun-Tae;Kim, Myoung-Joong;Kim, Jae-Dong
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.4 s.299
    • /
    • pp.219-223
    • /
    • 2007
  • The ionic conductivity of $Li_2O-ZrO_2-SiO_2$ glasses has been designed and analyzed on the basis of a mixture design experiment with constraints. Fitted models for the activation energy and the ionic conductivity are as follows: $Q(kJ/moi)=54.8565x_1+144.825x_2+133.846x_3-170.908x_1x_3-334.338x_2x_3$ $log{\sigma}(300K)=-5.00245x_1-1.17876x_2-15.5173x_3+17.4522x_1x_3$. The electrical properties are very sensitive to the ratio of $Li_2O/SiO_2$. The effect of $ZrO_2$ is less than that of this ratio but $ZrO_2$ component attributes to the reduction of the activation energy. The optimal composition for best ionic conduction based on these fitted models is $55Li_2O{\cdot}10ZrO_2{\cdot}35SiO_2$. Its activation energy and ionic conductivity at 300 K are 46.98 kJ/mol and $1.08{\times}10^{-5}{\Omega}^{-1}{\cdot}cm^{-1}$, respectively.

Printing Properties of Ag Paste with the Variation of Binder on the SiNx Coated Si Wafer (SiNx 층이 코팅된 Si Wafer에 바인더 종류에 따른 Ag 페이스트의 인쇄 특성)

  • Kang, Jea Won;Shin, Hyo Soon;Yeo, Dong Hun;Jeong, Dae Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.2
    • /
    • pp.85-90
    • /
    • 2014
  • Ag paste has been used in the front electrode of the Si-solar cell. It is composed by Ag powder, glass frit, binder, solvent and dispersant. The role of the binder and the solvent is to make a flow and a printing property. However, it was not enough to report the printing properties with the variation of binder in the controled viscosity. In this study, we selected 3 kinds of typical binder which were used as binder for the paste in the industry, such as Ethyl cellulose, Hydroxypropyl cellulose and Acrylic. Ag pastes using these were prepared, controled viscosity and printed on the SiNx coated Si wafer. In the 'A paste' used Acrylic binder, printed hight was highest and 'H paste' used Hydroxypropyl cellulose binder was lowest. Because 'H paste' was high viscosity due to the molecular weight, the solvent was added in the paste to control the viscosity. Therefore, the content of solid was lower in 'H paste'. The relative pattern width which is related to the spreading of paste was the best in the case of 'H paste' and 'EH paste' at $30^{\circ}C$. It is thought that the optimization of the relative pattern width is possible for a paste by the controling shear thinning phenomenon. In the case of 'A paste', though printing hight was best, the pattern width was dependant on the temperature.

How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materials

  • Hasanzade, Mahya;Moharrami, Mohammad;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.344-350
    • /
    • 2020
  • PURPOSE. Recently introduced hybrid and reinforced glass ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials have been used for full-coverage restorations. However; the effect of adjustment and type of materials on internal and marginal adaptation are unknown. This study aimed to evaluate and compare the marginal and internal adaptations of crowns made of three different CAD/CAM materials before and after adjustment. MATERIALS AND METHODS. One acrylic resin maxillary first molar was prepared and served as the master die. Thirty-six restorations were fabricated using CAD/CAM system (CEREC Omnicam, MCXL) with three materials including lithium disilicate (IPS e.max CAD), zirconia-reinforced lithium silicate (Suprinity), and hybrid ceramic (Enamic). Internal and marginal adaptations were evaluated with the reference point matching technique before and after adjustment. The data were analyzed using mixed ANOVA considering α=.05 as the significance level. RESULTS. The effect of adjustment and its interaction with the restoration material were significant for marginal, absolute marginal, and occlusal discrepancies (P<.05). Before adjustment, Suprinity had lower marginal discrepancies than IPS e.max CAD (P=.18) and Enamic (P=.021); though no significant differences existed after adjustment. CONCLUSION. Within the limitations of this study, crowns fabricated from IPS e.max CAD and Suprinity resulted in slightly better adaptation compared with Enamic crowns before adjustment. However, marginal, axial, and occlusal discrepancies were similar among all materials after the adjustment.