• 제목/요약/키워드: Ceramic tubular membrane

검색결과 31건 처리시간 0.023초

Advanced Water Treatment by Tubular Alumina Ceramic Ultrafiltration: Effect of Periodic Water-back-flushing Period

  • Park, Jin-Yong;Lee, Song-Hui
    • Korean Membrane Journal
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • The periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic ultrafiltration (UF) system for Gongji stream water treatment in Chuncheon city. The filtration time (FT), which was the water-back-flushing period, 2 min with periodic 15 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 6.35 L. Consequently FT 2 min at back-flushing time (BT) 15 sec could be the optimal condition in advanced UF water treatment of Gongji stream. Then the average rejection rates of pollutants by our tubular ceramic UF system were 99.4% for Turbidity, 31.8% for $COD_{Mn}$, 22.6% for $NH_3$-N and 65.9% for T-P.

Effect of Periodic Water-back-flushing Time ad Period in Water Treatment by Tubular Alumina Ceramic Microfiltration

  • Park, Jin-Yong;Lee, A-Reum
    • Korean Membrane Journal
    • /
    • 제10권1호
    • /
    • pp.33-38
    • /
    • 2008
  • In this study periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic micro filtration system for Gongji stream water treatment in Chuncheon city. The filtration time (FT) 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_0$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 7.44L. Also in the results of BT effect at fixed FT 10 min, BT (back-flushing time) 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_0$, and we could be obtained the highest $V_T$ of 8.04 L. Consequently FT 10 min and BT 20 sec could be the optimal condition in Gongji stream water treatment. Then the average rejection rates of pollutants by our tubular ceramic MF system were 93.8% for Turbidity, 20.7% for $COD_{Mn}$, 39.2% for $NH_3$-N and 31.5% for T-P.

Water Treatment of High Turbid Source by Tubular Ceramic Microfiltration with Periodic Water-back-flushing System

  • Lee, Hyuk-Chan;Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • 제9권1호
    • /
    • pp.12-17
    • /
    • 2007
  • We performed periodic water-back-flushing using permeate water to minimize membrane fouling to enhance permeate flux in tubular ceramic microfiltration system for water treatment of high turbid source. The filtration time (FT) = 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume $(V_T)\;=\;6.805L$. Also in the result of BT effect at fixed FT = 10 min and BT (back-flushing time) = 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_o$, and we could obtain the highest $V_T\;=\;6.660\;L$. Consequently, FT = 2 min and BT = 6 sec could be the optimal condition in water treatment of high turbid source above 10 NTU. However, FT = 10 min and BT = 20 sec was superior to reduce operating costs because of lower back-flushing frequency. Then the average quality of water treated by our tubular ceramic MF system was turbidity of 0.07 NTU, $COD_{Mn}$ of 1.86 mg/L and $NH_3-N$ of 0.007 mg/L.

관형 알루미나 세라믹 한외여과막에 의한 고도정수처리 시스템에서 물 역세척의 영향 (Effect of Water-back-flushing in Advanced Water Treatment System by Tubular Alumina Ceramic Ultrafiltration Membrane)

  • 박진용;이송희
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.194-202
    • /
    • 2009
  • 본 연구에서 처리수를 이용한 주기적인 역세척은 춘천시 공지천의 관형 세라믹 한외여과막에 의한 고도정수처리 시스템에서 막오염을 저감하고 투과선속을 향상시키고자 수행되었다. 일정한 역세척 시간(BT) 15초에서 여과시간 즉, 물 역세척 주기(FT) 2분이 가장 높은 무차원 투과선속(초기 투과선속에 대한 투과선속)과 가장 낮은 막오염 저항값을 보였다. 또한, FT 10분으로 고정한 BT 영향의 결과에서 BT 20초가 가장 낮은 막오염 저항과 가장 높은 무차원 투과선속을 나타내어, 가장 많은 총여과부피 107.3 L를 얻을 수 있었다. 결론적으로 공지천의 정수처리에서 FT 10분과 BT 20초가 최적조건으로 관형 알루미나 정밀여과의 선행 연구결과와 정확히 일치하였다. 한편 관형 세라믹 한외여과 시스템에 의한 오염물질 평균제거율은 탁도 97.0%, 망간법에 의한 COD 32.1%, 암모니아성 질소 28.8%, 총인 54.4%로 나타났다.

Fouling and cleaning of a tubular ultrafiltration ceramic membrane

  • Siddiqui, Farrukh Arsalan;Field, Robert W.
    • Membrane and Water Treatment
    • /
    • 제7권5호
    • /
    • pp.433-449
    • /
    • 2016
  • The successful application of cleaning protocols is vital for optimized filtration processes. A series of experiments with an ultrafiltration ceramic tubular membrane were carried out for the foulants dextran and carboxymethyl cellulose. Firstly, the impact on fouling of concentration changes was investigated with the increase in resistance being used as the key parameter. In the second phase, removal of reversible fouling was also investigated by employing intermittent rinsing consisting of a cold water rinse followed by a hot one. A comparative analysis for both foulants is reported. Across a range of concentrations and for both foulants, the reduction in resistance due to rinsing was found to depend upon concentration (C); it changed as $C^n$ where n was found to be 0.3. A plausible semi-theoretical explanation is given. Thirdly, for both foulants, the application of a combination of strong alkaline solutions with oxidizing agent (mainly sodium hypochlorite) followed by acid was found to be appropriate for cleaning of the ceramic membrane. The effect of increased temperature for cleaning agents followed by a warm water rinse contributed positively to the cleaning capability.

Tubular Alumina Microfiltration Membrane System with Periodic N2-back-flushing for Water Treatment

  • Park, Jin-Yong;Park, Seong-Jae;Kim, Geun-Su
    • Korean Membrane Journal
    • /
    • 제10권1호
    • /
    • pp.26-32
    • /
    • 2008
  • The Gongji stream water of Chuncheon city was filtrated by 2 kinds of tubular alumina ceramic MF membranes with periodic $N_2$-back-flushing. $N_2$-back-flushing time (BT) was changed in $0{\sim}50$ sec at fixed filtration time (FT), or back-flushing period, of 4 min for NCMT-5231 membrane ($0.05\;{\mu}m$). Then, FT was changed in $0{\sim}32$ min at fixed BT of 40 sec for NCMT-7231 $0.1{\mu}m)$). In the viewpoints of total permeate volume ($V_T$), dimensionless permeate flux ($J/J_0$) and resistance of membrane fouling ($R_f$), the optimal $N_2$-BT was 50 sec, which was the longest BT, at 4 min FT for NCMT-5231. It means the longest BT was the most effective to minimize the membrane fouling, and we could acquire the most $V_T$. But the optimal FT for NCMT-7231 was 16 min in the viewpoint of $V_T$, and was 8 min in the viewpoints of $J/J_0$ and $R_f$ at fixed BT of 40 sec. The rejection rates were excellent as $80.6{\sim}96.6\;%$ for turbidity, $35.2{\sim}58.4%$ for $NH_3$-N, $16.3{\sim}45.2%$ for T-P and $16.3{\sim}45.2%$ for $COD_{Mn}$. However, the rejection rate of T-N was very low as $2.7{\sim}13.4%$ and it of TDS below 6.1%.

Effect of $N_2$-backflushing Time in Carbon Ceramic UF & MF System for Paper Wastewater Treatment

  • Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • 제7권1호
    • /
    • pp.34-41
    • /
    • 2005
  • The wastewater discharged from a paper plant was filtrated by 3 kinds of tubular carbon ceramic UF and MF membranes with $N_2$-backflushing. The filtration time (FT) was fixed at 8 min or 16 min, and $N_2$-backflushing time (BT) was changed in 0${\~}$60 sec. The optimal condition was discussed in the viewpoints of total permeate volume ($V_T$), dimensionless permeate flux (J/Jo) and resistance of membrane fouling ($R_f$). In the viewpoints of $V_T$, J/Jo and $R_f$, the optimal $N_2$-BT was 40 sec at both FT for M9 (MWCO: 300,000 Daltons) and C005 ($0.05{\mu}m$) membranes. However, for C010 ($0.1{\mu}m$) it was 10 sec at FT=8 min, and 20 sec at FT=16 min in the viewpoints of J/Jo and $R_f$, and 5 sec at both FT in the viewpoints of $V_T$. It means that the short $N_2$-BT could reduce the membrane fouling and recover the permeate flux sufficiently for MF membrane having a large pore size as C010. Average rejection rates of pollutants were higher than $99.0\%$ for turbidity and $22.8{\~}59.6\%$ for $COD_{cr}$, but rejection rates of total dissolved solid (TDS) were lower than $8.9\%$. Therefore, the low turbidity water purified in our system could be reused for paper process.

정밀여과용 관형막을 이용한 바이오디젤 제조 (Biodiesel Production using Microfiltration Tubular Membrane)

  • 이원중;정건용
    • 멤브레인
    • /
    • 제20권2호
    • /
    • pp.113-119
    • /
    • 2010
  • 카놀라유, 대두유, 자트로파유와 메탄올을 연속적으로 분리막 반응기에 순환시켜 바이오디젤을 제조하였다. 분리막은 반응기 역할과 반응 생성물로부터 미반응된 유지를 분리하여 고순도의 fatty acid methyl ester (FAME)를 생산하는 역할을 한다. 공칭 세공크기 0.2, 0.5 ${\mu}m$인 정밀여과형 세라믹 관형 분리막을 사용하였다. 운전압력 0.5 bar에서 0.2 ${\mu}m$ 정밀여과막에 대한 투과유속은 공급유량 400 mL/min일 경우 15 L/$m^2{\cdot}hr$이었다. 또한 투과액중 FAME 함량은 0.5 bar에서 가장 높았으며 운전압력이 증가할수록 감소하였다.

Membrane Bioreactor를 이용한 폭발성 물질의 가수분해 부산물의 탈질과정에의 적용 (Application of a Membrane Bioreactor in Denitrification of Explosives Hydrolysates)

  • 조경덕
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.113-122
    • /
    • 2002
  • A bench-scale anoxic membrane bioreactor (MBR) system, consisting of a bioreactor coupled to a ceramic crossflow ultrafiltration module, was evaluated to treat a synthetic wastewater containing alkaline hydrolysis byproducts (hydrolysates) of RDX, The wastewater was formulated the same as RDX hydrolysates, and consisted of acetate, formate, formaldehyde as carbon sources and nitrite, nitrate as electron accepters. The MBR system removed 80 to 90% of these carbon sources, and approximately 90% of the stoichiometric amount of nitrate, 60% of nitrite. The reactor was also operated over a range of transmembrane pressures, temperatures, suspended solids concentration, and organic loading rate in order to maximize treatment efficiency and permeate flux. Increasing transmembrane pressure and temperature did not improve membrane flux significantly. Increasing biomass concentration in the bioreactor decreased the permeate flux significantly. The maximum volumetric organic loading rate was $0.72kg\;COD/m^3/day$, and the maximum F/M ratio was 0.50 kg N/kg MLSS/day and 1.82 kg COD/kg MLSS/day. Membrane permeate was clear and essentially free of bacteria, as indicated by heterotrophic plate count. Permeate flux ranged between 0.15 and $2.0m^3/m^2/day$ and was maintained by routine backwashing every 3 to 4 day. Backwashing with 2% NaOCl solution every fourth or fifth backwashing cycle was able to restore membrane flux to its original value.