• Title/Summary/Keyword: Ceramic materials

Search Result 5,150, Processing Time 0.033 seconds

Synthesis and Phase Relations of Potassium-Beta-Aluminas in the Ternary System K2O-MgO-Al2O3 (K2O-MgO-Al2O3 3성분계에서 K+-β/β"-Al2O3의 합성 및 상관계)

  • Ham, Choul-Hwan;Lim, Sung-Ki;Lee, Chung-Kee;Yoo, Seung-Eul
    • Applied Chemistry for Engineering
    • /
    • v.10 no.7
    • /
    • pp.1086-1091
    • /
    • 1999
  • $K^+-{\beta}/{\beta}"-Al_2O_3$ in the ternary system $K_2O-MgO-Al_2O_3$ was directly synthesized by solid state reaction. The phase formation and phase relation were carefully investigated in relation to starting composition, calcining temperature and time, and dispersion medium. The optimal synthetic condition was also examined for the formation of ${\beta}"-Al_2O_3$ phase with a maximum fraction. As a composition range, the mole ratio of $K_2O$ to $Al_2O_3$ was changed from 1:5 to 1:6.2 and the amount of MgO used as a stabilizer was varied from 4.2 wt % to 6.3 wt %. The calcining temperature was selected between $1000^{\circ}C$ and $1500^{\circ}C$. At $1000^{\circ}C$, the ${\beta}/{\beta}"-Al_2O_3$ phases began to form resulted from the combining of ${\alpha}-Al_2O_3$ and $KAlO_2$ and increased with temperature rising. All of ${\alpha}-Al_2O_3$ phase disappeared to be homogenized to the ${\beta}/{\beta}"-Al_2O_3$ phase at $1200^{\circ}C$. Near the temperature at $1300^{\circ}C$, the fraction of ${\beta}"-Al_2O_3$ phase showed a maximum value with the composition of $K_{1.67}Mg_{0.67}Al_{10.33}O_{17}$. At temperatures above $1300^{\circ}C$, the fraction of ${\beta}"-Al_2O_3$ phase decreased gradually owing to $K_2O$ loss caused by a high potassium vapor pressure, and the appropriate calcining time was about 5 hours. Acetone was more effective than distilled water as a dispersion medium for milling and mixing.

  • PDF

Effect of titanium surface microgrooves and thermal oxidation on in vitro osteoblast responses (마이크로그루브 및 열산화 복합 티타늄 표면의 골아세포분화 증진효과)

  • Seo, Jin-Ho;Lee, Richard sungbok;Ahn, Su-Jin;Park, Su-Jung;Lee, Myung-Hyun;Lee, Suk Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.198-206
    • /
    • 2015
  • Purpose: We aimed to investigate the effect of combined various microgrooves and thermal oxidation on the titanium (Ti) and to evaluate various in vitro responses of human periodontal ligament cells (PLCs). Materials and methods: Grade II titanium disks were fabricated. Microgrooves were applied on titanium discs to have $0/0{{\mu}m}$, $15/3.5{{\mu}m}$, $30/10{{\mu}m}$, and $60/10{{\mu}m}$ of respective width/depth by photolithography. Thermal oxidation was performed on the microgrooves of Ti substrata for 3 h at $700^{\circ}C$ in air. The experiments were divided into 3 groups: control group (ST), thermal oxidation group (ST/TO), and combined microgrooves and thermal oxidation group (Gr15-TO, Gr30-TO, Gr60-TO). Surface characterization was performed by field-emission scanning microscopy. Cell adhesion, osteoblastic differentiation, and mineralization were analyzed using the bromodeoxyurdine (BrdU), Alkaline phosphatase (ALP) activity, and extracellular calcium deposition assays, respectively. Statistical analysis was performed using the oneway analysis of variance and Pearson's bivariate correlation analysis (SPSS Version 17.0). Results: In general, the combined microgrooves and thermal oxidation group (Gr15-TO, Gr30-TO, Gr60-TO) showed significantly higher levels compared with the control (ST) or thermal oxidation (ST-TO) groups in the BrdU expression, ALP activity, and extracellular calcium deposition. Gr60-TO group induced highest levels of cell adhesion and osteoblastic differentiation. Conclusion: Within the limitation of this study, we conclude that the Ti surface treatment using combined microgrooves and thermal oxidation is highly effective in inducing the cell adhesion andosteoblastic differentiation. The propose surface is also expected to be effective in inducing rapid and strong osseointegration of Ti oral implants.

Nondestructive Evaluation and Microfailure Mechanisms of Single Fibers/Brittle Cement Matrix Composites using Electro-Micromechanical Technique and Acoustic Emission (Electro-Micromechanical 시험법과 Acoustic Emission을 이용한 단섬유/시멘트 복합재료의 미세파괴 메커니즘과 비파괴적 평가)

  • 박종만;이상일;김진원;윤동진
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.18-31
    • /
    • 2001
  • Interfacial and microfailure properties of the modified steel, carbon and glass fibers/cement composites were investigated using electro-pullout test under tensile and compressive tests with acoustic emission (AE). The hand-sanded steel composite exhibited higher interfacial shear strength (IFSS) than the untreated and even neoalkoxy zirconate (Zr) treated steel fiber composites. This might be due to the enhanced mechanical interlocking, compared to possible hydrogen or covalent bonds. During curing process, the contact resistivity decreased rapidly at the initial stage and then showed a level-off. Comparing to the untreated case, the contact resistivity of either Zr-treated or hand-sanded steel fiber composites increased to the infinity at latter stage. The number of AE signals of hand-sanded steel fiber composite was much more than those of the untreated and Zr-treated cases due to many interlayer failure signals. AE waveforms for pullout and frictional signals of the hand-sanded composite are larger than those of the untreated case. For dual matrix composite (DMC), AE energy and waveform under compressive loading were much higher and larger than those under tensile loading, due to brittle but well-enduring ceramic nature against compressive stress. Vertical multicrack exhibits fur glass fiber composite under tensile test, whereas buckling failure appeared under compressive loading. Electro-micromechanical technique with AE can be used as an efficient nondestructive (NDT) method to evaluate the interfacial and microfailure mechanisms for conductive fibers/brittle and nontransparent cement composites.

  • PDF

Quality Changes in Oyster Mushrooms during Modified Atmosphere Storage as Affected by Temperatures and Packaging Materials (저장 온도와 포장재에 따른 느타리버섯의 MA 저장 중 품질변화)

  • Choi, Mi-Hee;Kim, Gun-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1079-1085
    • /
    • 2003
  • Modified atmosphere packaging was applied to oyster mushrooms (Pleurotus ostreatus) to study the effect of storage temperatures and packaging materialso. Whole mushrooms (200g) were package with polyethylene film $(PE,\;60{\mu}m\;thickness)$, ethylene vinyl acetate (EVA), or ceramic film (containing 5% zeolite) and stored at 0, 5, 10 and $20^{\circ}C$. Weight loss, color, firmness, gas composition $(O_2,\;CO_2)$ inside the film package and ethanol content in the tissue of MA packaged mushrooms were examined. Mushroom that were packed unwrapped in a conventional hardboard box (2 kg) lost marketability at a very early stage of storage due to weight loss, shrinkage, browning, and spore formation. During storage, film packaging prevented or retarded the deterioration of the mushrooms in the aspects of appearance, texture, and discoloration. Firmness slightly decreased with storage time. Total color difference was much higher in the control than in the film-packaged mushroom and rapidly increased at the early of storage. Correlation analysis showed a high correlation between total color difference and b values. These results were characterized by the reduced respiration rate resulting from elevated carbon dioxide and reduced oxygen levels in the package. At all storage temperatures, ethanol content in the tissue increased slightly at the early part of storage and rose considerably towards the end of the storage period. Ethanol content in the oyster mushrooms was higher in the stipe than in pileus tissues. The shelf life of the oyster mushrooms was about $8{\sim}11$ days at $0^{\circ}C$, about $4{\sim}6$ day at $5^{\circ}C$, about $2{\sim}3$ days at $10^{\circ}C$, and about $1{\sim}2$ days at $20^{\circ}C$.

A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system (지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구)

  • Lee, Sang-Hyeok;Ahn, Jin-Soo;Kim, Myung-Ho;Lim, Bum-Soon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.235-242
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the fracture behavior of Zironia, glass infiltrated Alumina and PFM full crown system. Materials and methods: Fifteen crowns for each of 3 experimental groups (Zironia, glass infiltrated Alumina and PFM full crown) were made by the conventional method. The crowns mounted on the testing jig were inclined in 30 degrees to the long axis of the tooth and the universal testing machine was used to measure the fracture strength. Results: 1. The mean fracture strengths were $588.3{\pm}49.6MPa$ for zirconia system, $569.1{\pm}61.8MPa$ for PFM system and $551.0{\pm}76.5MPa$ for glass-infiltrated alumina system (P>.05). 2. The mean shear bond strengths were $25.5{\pm}5.6MPa$ for zirconia system, $38.9{\pm}5.0MPa$ for Ni-Cr alloy system and $39.4{\pm}5.1MPa$ for glass-infiltrated alumina system. 3. The chemical bonding was observed at interfaces between PFM or glass-infiltrated alumina and veneering porcelain, however, no chemical bonding was observed at interface between zirconia and veneering porcelain. Conclusion: With the study, the fracture strengths of PFM crown system had a higher fracture strength than conventional zirconia system crown and glass-infiltrated alumina crowns. and than the shear bond strengths glass-infiltrated alumina system had a higher shear bond strength than conventional PFM system and zirconia system.

A Study on Goryo Celadons of intaglio '○' pattern and '⊙'pattern (고려 음각 '○'문과 '⊙'문청자의 연구)

  • Han, Seong-Uk
    • KOMUNHWA
    • /
    • no.70
    • /
    • pp.133-161
    • /
    • 2007
  • It is judged that celadons with '○' pattern and '⊙' pattern have the indication of manufacturer by engraving mark at the internal center of the bottom. These celadons were produced at No.8.23.27 kiln sites located at Sadang-ri(사당리), Daegu-myon(대구면), Gangjin-gun(강진군), Jeollanamdo(전라남도), Korea and '⊙’ patterned celadon porcelain was found only at No. 23 and 27 kiln sites, so it is assumed that its production sites were limited. Kinds of celadons included bowl, dish, cup, bottle, case and vessel for emptied wine and there were a lot of dishes with a variety of patterns. These celadons were engraved by molded design technique using the same ceramic design as the pattern of celadons in the period of their prosperity and it was appropriate method to produce celadons of a good quality with production method to keep decorative design like pattern or size uniformly. It was also found that inlay method was not universalized in this period and similar celadons were produced with molded design in large quantities. These celadons had partially fire clay temper, but most of them were burnt by supporting the inner bottom of U-type base with quartzite after whole glazing. It was known through relics excavated at Seokreung(석릉) royal tomb of King Heejong(희종) at Ganghwa(강화) and Hyeeumwon(혜음원) temple site at Paju(파주) and military house at Wakamiyaoji(약궁대로) avenue Kamakura(겸창)-city, Japan(일본) that these celadons were manufactured at two quarters of the 13th century centering around 1230s. Therefore, these celadons will be significant materials to fill the gap of the celadons in the 13th century resulted from the record chronologically that green celadons were manufactured in the 12th century. And this period was invaded by Mongolia(몽고), but central control was achieved and green celadons were continuously produced. It was also considered that these celadons were excavated at Gabgot-ri(갑곶리) and Gwanchung-ri(관청리), Ganghwa(강화), Hyeeumwon temple, Paju which played the role of temporary palace, Bu1guksa(불국사) temple at Gyeongju(경주), Silsangsa(실상사) temple at Namwon(남원) and relics of Jangheung(장흥) adjacent to Daeguso(대구소) and these were produced for high class.

  • PDF

International Conference on Electroceramics 2005 (2005년도 국제 전자세라믹 학술회의)

  • 한국세라믹학회
    • Proceedings of the Korean Ceranic Society Conference
    • /
    • 2005.06a
    • /
    • pp.1-112
    • /
    • 2005
  • This report is results of a research on recent R&D trends in electroceramics, mainly focusing on the papers submitted to the organizing committee of the International Conference on Electroceramics 2005 (ICE-2005) which was held at Seoul on 12-15 June 2005. About 380 electroceramics researchers attended at the ICE-2005 from 17 countries including Korea, presenting and discussing their recent results. Therefore, we can easily understand the recent research trends in the field of electroceramics by analyses of the subject and contents of the submitted papers. In addition to the analyses of the papers submitted to the ICE-2005, we also collected some informations about domestic and international research trends to help readers understand this report easily. We analysed the R&D trends on the basis of four main categories, that is, informatics electroceramics, energy and environment ceramics, processing and characterization of electroceramics, and emerging fields of electroceramics. Each main category has several sub-categories again. The informatics ceramics category includes integrated dielectrics and ferroelectrics, oxide and nitride semiconductors, photonic and optoelectronic devices, multilayer electronic ceramics and devices, microwave dielectrics and high frequency devices, and piezoelectric and MEMS applications. The energy and environment ceramics category has four sub-categories, that is, rechargable battery, hydrogen storage, fuel cells, and advanced energy conversion concepts. In the processing and characterization category, there exist domain, strain, and epitaxial dynamics and engineering sub-category, innovative processing and synthesis sub-category, nanostructured materials and nanotechnology sub- category, single crystal growth and characterization sub-category, theory and modeling sub-category. Nanocrystalline electroceramics, electroceramics for smart sensors, and bioceramics sub-categories are included to the emerging fields category. We hope that this report give an opportunity to understand the international research trend, not only to Korean ceramics researchers but also to science and technology policy researchers.

  • PDF

Study on the Development and Properties of Ceramics Restoration Purpose Urethane resin with Excellent Reversibility (가역성이 우수한 도자기 복원용 Urethane resin의 개발 및 물성에 대한 연구)

  • Oh, Seung Jun;Park, Gi Jung;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.37-46
    • /
    • 2015
  • In the case of adhesives & restoration agents currently being used for the preservation treatment of ceramics and earthenware, epoxy type, cellulose type and cellulose type are mainly being used. However, they are showing various problems such as re-detachment from severe contraction, color change from yellowing, work inconvenience of staining on tools and hand during usage and irreversibility. For the purpose of solving the issues of yellowing and irreversibility of epoxy resin being used to restore ceramics, urethane synthetic resin with low yellowing excellent reversibility has been developed in this study. The adhesive strength of urethane resin that has been developed has excellent properties with 2.07MPa for undiluted solution, which is 1.5 times higher than that of existing material EPO-$TEK301^{(R)}$ 1.21MPa. The result of workability measurement showed that the wear rate of urethane resin (in Talc 50wt%) was 1.09%, which was somewhat higher than that of existing material Quick $Wood^{(R)}$ (1.02%). In addition, its wear rate is two times higher than that of $EPO-TEK301^{(R)}$ (0.41%) and $L30^{(R)}$ (0.39%), thereby showing an advantage in its forming process compared to existing materials. As for the advantage of urethane resin of reversibility experiment, 12 hours after acetone, ethyl alcohol deposition, urethane resin and filler talc were dissolved 100% while showing powdering phenomenon. Compared to 0% reversibility of existing epoxy resin, it has much superior reversibility. The result of UV rays experiment to evaluate its durability showed that ${\Delta}E^*ab$ color change value based on undiluted solution of urethane resin was 2.76 before & after UV rays exposure, which was a decrease by about 7-20 times compared to that of existing resin, thereby minimizing the issue of heterogeneity.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.