• 제목/요약/키워드: Ceramic Metal

검색결과 1,481건 처리시간 0.037초

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics

  • Vernekar, Naina Vilas;Jagadish, Prithviraj Kallahalla;Diwakar, Dr Srinivasan;Nadgir, Ramesh;Krishnarao, Manjunatha Revankar
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.113-118
    • /
    • 2011
  • PURPOSE. The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations. MATERIALS AND METHODS. For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test. RESULTS. Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/$m^2$. Group 1 showed the maximum and Group 5 showed the least value. CONCLUSION. The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.

Infiltration Processing of Ceramic-Metal Composites: The Role of Wettability, Reaction, and Capillary Flow

  • Asthana Rajiv;Singh Mrityunjay;Sobczak Natalia
    • 한국세라믹학회지
    • /
    • 제42권11호
    • /
    • pp.703-717
    • /
    • 2005
  • The infiltration of ceramics by liquid metals to fabricate ceramic-metal composites is discussed. In particular, the complexity of infiltrating ceramics by liquid metals at high temperatures due to interfacial reactions, metal oxidation, pore modulation and closure, and transient capillary forces has been highlighted. The role of these factors is discussed in the context of reactive infiltration with examples from ceramic/metal composites of practical interest. In addition to flow through porous ceramics, reactive penetration of dense ceramics via chemical dissolution and reaction is also discussed.

A study on the fracture strength of collarless metal-ceramic fixed partial dentures

  • Yoon, Jong-Wook;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.134-141
    • /
    • 2010
  • PURPOSE. The objective of this study was to evaluate fracture strength of collarless metal-ceramic FPDs according to their metal coping designs. MATERIALS AND METHODS. Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Fifteen 3-unit collarless metal-ceramic FPDs were fabricated in each group. Finished FPDs were cemented to PBT (Polybutylene terephthalate) dies with resin cement. The fracture strength test was carried out using universal testing machine (Instron 4465, Instron Co., Norwood MA, USA) at a cross head speed of 0.5 mm/min. Aluminum foil folded to about 1 mm of thickness was inserted between the plunger tip and the incisal edge of the pontic. Vertical load was applied until catastrophic porcelain fracture occurred. RESULTS. The greater the bulk of unsupported facial shoulder porcelain was, the lower the fracture strength became. However, there were no significant differences between experimental groups (P > .05). CONCLUSION. All groups of collarless metal-ceramic FPDs had higher fracture strength than maximum incisive biting force. Modified collarless metal-ceramic FPD can be an alternative to all-ceramic FPDs in clinical situations.

응력특이성을 고려한 세라믹/금속 접합재의 정적강도평가 (Evaluation of Static Strength on Ceramic /Metal Bonded Joints Considering Stress Singularity)

  • 김기성
    • 한국생산제조학회지
    • /
    • 제6권1호
    • /
    • pp.59-68
    • /
    • 1997
  • Recently, the cases of using bonded dissimiliar materials which have each of the different components tend to increase for the purpose of developing new materials and using the special objects in the field of industry. Among the cases the strength evaluation of the joining materials of vehicle engine and the structural materials with ceramic/metal bonded joints becomes more important. But the residual stress occurs, because the joining of ceramics and metals is performed in extremely high temperature. It becomes a dominant cause to reduce the strength of the ceramic/metal bonded joints. In this paper, strength evaluation method of ceramic/metal bonded joints considering stress singularity was investigated by boundary element method and 4-point bending test. An advanced method of quantitative strength evaluation for ceramin/metal bonded joints is to be suggested.

  • PDF

A Nano-particle Deposition System for Ceramic and Metal Coating at Room Temperature and Low Vacuum Conditions

  • Chun, Doo-Man;Kim, Min-Hyeng;Lee, Jae-Chul;Ahn, Sung-Hoon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권1호
    • /
    • pp.51-53
    • /
    • 2008
  • A new nano-particle deposition system (NPDS) was developed for a ceramic and metal coating process. Nano- and micro-sized powders were sprayed through a supersonic nozzle at room temperature and low vacuum conditions to create ceramic and metal thin films on metal and polymer substrates without thermal damage. Ceramic titanium dioxide ($TiO_2$) powder was deposited on polyethylene terephthalate substrates and metal tin (Sn) powder was deposited on SUS substrates. Deposition images were obtained and the resulting chemical composition was measured using X-ray photoelectron spectroscopy. The test results demonstrated that the new NPDS provides a noble coating method for ceramic and metal materials.

금속도재, 전장도재, 지르코니아 수복물에서의 도재 파절 (Porcelain Fracture in Metal Ceramic, All ceramic and Zirconia restoration)

  • 김철연
    • 대한심미치과학회지
    • /
    • 제32권2호
    • /
    • pp.46-53
    • /
    • 2023
  • 도자기 파절은 금속도재, 전부도재, 지르코니아 수복물의 흔한 문제점이다. 이와 관련되 여러가지 요소들이 제시되는데, 금속의 물성, 금속도재의 금속 코핑의 형태, 가공 방법, 지지형태, 교하벽, 비기능적 습관들이 포함된다. 이 논문에서는 이런 요소들을 조금더 구체적으로 살펴보고자 한다.

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

상악 중절치 삭제 시 수복 디자인과 변연부 위치에 따른 부피 변화 (Volume difference in upper central incisor preparation according to the changes of restorative design and marginal location)

  • 김종현;박영범;김성태;이근우
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.152-160
    • /
    • 2011
  • 연구 목적: 상악 중절치에 여러 가지 수복물 설계와 변연부 위치를 설정하여 치아 삭제를 하였을 때 나타나는 치아 삭제량의 변화를 평가하기 위함이다. 연구 재료 및 방법: 36개의 상악 중절치 레진 인공치가 실험에 사용되었다. 수복물의 디자인에 따라 이들은 4개의 군으로 나뉘었다. 그리고 각각의 군은 다시 변연부의 위치에 따라 3개의 세부 군으로 나뉘었다. 삭제되지 않은 치아의 부피가 미세단층촬영을 이용해 측정되었고 같은 방법으로 삭제 후의 치아의 부피가 측정되었다. 이 측정된 영상들을 서로 겹쳐서 비교함으로 삭제 전과 후의 부피 변화를 알아보았다. 결과: 수복물 설계에 따른 삭제 전과 후의 부피 변화량은 다음과 같은 순서로 변화량의 차이를 보였다: traditional laminate veneer < full laminate veneer < all ceramic crown < metal ceramic crown. One-Way ANOVA와 다중비교 Tukey로 유의수준5%에서 통계 분석한 결과 각각의 군에서는 다음과 같은 순서로 변화량의 차이를 보였다: CEJ 1 mm 상방 < CEJ < CEJ 1 mm 하방 (P<.05). 부피 변화를 백분율로 나타낸 수치를 보면 all ceramic crown과 metal ceramic crown 에서는 31 - 48% 로 나타났고 laminate veneer에서는 14 - 30%로나타났다. Laminate veneer에서 나타난 부피 변화량은 metal ceramic crown의 1/3로 나타났다. The full laminate (CEJ 1 mm 하방)와 all ceramic crown (CEJ 1 mm 상방)는 유사한 부피 변화를 보였다. Metal ceramic crown은 all ceramic crown과 비교하였을 때 13.7% 더 많은 부피 변화를 보였다. 결론: 수복물의 설계와 변연부 위치의 변화에 따라 부피 변화의 차이가 존재한다.

열-가압을 이용한 금속 도재관과 전통적인 금속 도재관의 변연 적합도 비교 연구 (Comparative study in marginal fit of a pressed ceramic and feldspathic porcelain fused to metal restoration)

  • 김윤영;박윈희;유동엽;이영수
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.273-279
    • /
    • 2010
  • 연구 목적: 본 연구의 목적은 전통적인 금속 도재관과 열-가압을 이용한 금속-도재관의 변연 적합도를 비교하는 것이다. 연구 재료 및 방법: 상악 제1소구치 레진 치아를 교합면 2.0 mm, 협, 설면과 인접면을 1.0 mm 두께로 삭제하였으며, 변연 형태는 chamfer margin으로 그리고 축면 경사는 6도 taper로 삭제하였다. 삭제한 레진치를 복제하여 금속 다이 20개를 제작하였고, 이 금속 다이를 인상 채득하여 작업을 위한 석고 다이를 제작하였다. 금속 도재관과 $PoM^{(R)}$ 시스템 (Ivoclar vivadent., Liechtenstein)의 두 그룹으로 나누어 금속 코핑을 각각 10개씩 총 20개를 제작하였으며, 광학 현미경을 이용하여 변연 간격을 측정하였다. 도재 축성 후, 위와 동일한 방법으로 변연 간격을 측정하였다. 통계 처리는 Wilcoxon Signed Ranks test와 Mann Whitney U test를 이용하여 분석하였다. 결과: 본 연구의 결과는 다음과 같다. 1. 금속 도재관은 코핑 상태 ($64.93{\pm}12.48\;{\mu}m$)와 도재 축성 후 ($63.43{\pm}12.86\;{\mu}m$)의 변연 간격에 유의성 있는 차이를 보이지 않았다. 2. $PoM^{(R)}$ 시스템은 코핑 상태 ($50.00{\pm}12.28\;{\mu}m$)와도재축성후($56.72{\pm}13.80\;{\mu}m$)의 변연 간격에 유의성 있는 차이를 보이지 않았다. 3. 금속 도재관과 $PoM^{(R)}$ 시스템 변연 간격은 유의성 있는 차이를 보이지 않았다. 결론: $PoM^{(R)}$시스템은 왁스 소결법을 이용해 변화가 적은 기술적인 이점이 있으며, 세밀한 기술을 요구하는 축성 방법과는 대조적으로 왁스 성형으로 도재의 완전한 형태를 만들 수 있는 편리함을 제공하는 장점을 가진다. 본 연구 결과와 이런 장점을 토대로 앞으로 임상적 사용을 고려해 볼 수 있을 것으로 사료된다.

교정용 Resin bracket의 마찰 저항력에 관한 연구 (A Study on Frictioal Resistance Force of Orthodontic Resin Bracket)

  • 이원유;임경수
    • 대한치과교정학회지
    • /
    • 제29권1호
    • /
    • pp.107-112
    • /
    • 1999
  • 성인 교정 환자가 증가됨에 따라 교정장치의 심미성이 요구되고 있다. 교정 장치의 심미적 증진을 위해 개발된 브라켓들로는 세라믹, 콤포지트 레진 브라켓, 타이타늄 브라켓등이 소개되고 있다. 콤포지트 레진 브라켓은 우수한 색상 및 투과성이 장점이나 높은 마찰력과 낮은 취성의 단점을 갖고 있다. 이러한 단점을 보완하기 위하여 최근 개발된 세라믹 또는 레진 브라켓(metal reinforced bracket)은 마찰력을 감소시키고 강도를 증가시키기 위하여 브라켓의 슬롯에 메탈을 삽입하고 있다. 그러나 지금까지 이러한 metal reinforced resin bracket(이후 MRRB)의 물성에 관한 연구가 미진하였다. 특히 이러한 브라켓과 교정용 철선의 마찰력에 관한 연구가 미흡하기에 본 연구를 시행하였다. 본 연구는 4종의 교정용 철사(.016 S-S, .0l6X.022 S-S, .016 $TMA^{\circledR}$, .0l7X.025 $TMA^{\circledR}$)와 5종의 브라켓을 사용하였다. 사용된 브라켓들로는 메탈 1종(Ormco.Co., U.S.A)자 세라믹 1종($Crystalline^{\circledR}$), 콤포지트 레진 1종(Clear Medium $Siamase^{\circledR}$), 메탈 슬롯이 삽입된 콤포지트 레진2종($Plastic^{\circledR},\;Spirit^{\circledR}$)의 마찰력을 서로 비교하여 다음과 같은 결과를 얻었다. 1. ceramic bracket과 resin bracket은 metal reinforced resin bracket과 metal bracket보다 마찰력이 유의성 있게 크게 나타났다. 2. metal reinforced resin bracket의 slot내 metal의 삽입형태에 따른 마찰력의 크기는 유의차가 없었다. 3. metal reinforced resin bracket과 metal bracket사이의 마찰력의 크기는 유의차가 없었다. 4.. 교정용 철선과 각 브라켓 비교에서 TMA, Stainless steel 순으로 마찰력이 적게 나타났다.

  • PDF