• Title/Summary/Keyword: Ceramic Metal

Search Result 1,481, Processing Time 0.031 seconds

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

  • Song, Tae-Jin;Kwon, Taek-Ka;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • PURPOSE. Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS. Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS. Mean marginal gaps of 3-unit FPDs were $60.46{\mu}m$ for the Everest group, $78.71{\mu}m$ for the Lava group, and $81.32{\mu}m$ for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION. The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

The Influence of Bonding Strength and Interface Characteristics to Bonding Agent and Veneer Ceramics on Metal-Ceramic Prosthetics (결합재와 베니어세라믹이 금속-세라믹 보철물의 전단결합강도와 계면특성에 미치는 영향)

  • Kim, Min-Jung;Choi, Sung-Min;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.349-357
    • /
    • 2011
  • Purpose: In this study, for the reasons of observing the changes when using bonding agent with Ni-Cr alloy and Co-Cr alloy and using VM13 and Vintage MP ceramic which have the disparity in coefficient of thermal expansion, it is carried out to evaluate the characteristics of the bonding agent through the analysis of the interface between metal and ceramic and the analysis of bond strength by variable. Methods: The surface treatment was performed on the two kinds of alloy(Ni-Cr alloy and Co-Cr alloy) specimens, which were sandblasted and were treated with bonder application. The metal-ceramic interfaces were analyzed with EPMA in order to ionic diffusion, and the shear test was performed. Results: As a result of observation of metal-ceramic interfacial properties, it was observed that Cr atoms were spread from the alloy body to the ceramic floor in the specimen of Group B. It was also seen that Cr, W atoms were spread from the alloy body to the ceramic floor in the specimen of Group S. In consequence of observing Shear bond strength, it was calculated that the specimen of BSV was 27.75(${\pm}11.21$)MPa, BSM was 27.02(${\pm}5.23$)MPa, BCV was 30.20(${\pm}5.99$)MPa, BCM was 27.94(${\pm}10.76$)MPa, SSV was 20.83(${\pm}2.58$)MPa, SSM was 23.98(${\pm}3.94$)MPa, SCV was 32.32(${\pm}4.68$)MPa, and SCM was 34.54(${\pm}10.63$)MPa. Conclusion: In the metal-ceramic interface of Bellabond plus sample group, diffusion of Cr atoms was incurred and diffusion of C Cr atoms and W atoms in the sample group of $Starloy{(R)}\;C$ was observed. Using bonding agent showed the higher bond strength than using the sand blasting treatment. In the Bellabond plus alloys, the specimen group with the use of binding materials showed higher shear bond strength, but didn't show statistically significant differences (p>0.05). In the $Starloy{(R)}\;C$ alloys, the specimen group with the use of binding materials showed higher shear bond strength and statistically significant differences(p<0.05). In terms of VM13 ceramic, it was in the Bellabond plus alloys that the high shear bond strength was showed, but there's no statistically significant differences(p>0.05). In terms of Vintage MP ceramic, it was in the $Starloy{(R)}\;C$ alloys that the high shear bond strength was showed and statistically significant differences(p<0.05). Metal-ceramic to fracture of the shear strength measurements and an analysis of all aspects of military usage fracture of the composite, respectively.

IN VITRO SHEAR BOND STRENGTH OF CERAMIC BRACKETS (도재 브라켓의 전단접착강도에 관한 실험적 연구)

  • Lee, Suhng-Jin;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.22 no.2 s.37
    • /
    • pp.449-474
    • /
    • 1992
  • The purpose of this study was to evaluate the in vitro shear bond strengths to enamel and the failure sites of three ceramic brackets and one metal bracket in combination with light cured orthodontic adhesive. The brackets were divided into four groups. Each ceramic bracket group had different bonding mechanisms with adhesive. Group A; metal bracket with foil-mesh base (control group) Group B; ceramic bracket with micromechanical retention Group C; ceramic bracket with chemical bonding Group D; ceramic bracket with mechanical retention and chemical bonding. Forty extracted human lower first premolars were prepared for bonding and 10 brackets for each group were bonded to prepared enamel surfaces with $Transbond^{\circledR}$ light cured ortho dontic adhesive. Twenty four hours after bonding, the Instron universal testing machine was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites, Statistical analysis of the data was carried out with ANOVA test and $Scheff\acute{e}$ test using SPSS PC+. The results were as follows. 1 . There were statistically significant differences in mean shear bond strengths of three ceramic bracket groups (p < 0.05). Shear bond strengths of group C and D were significantly higher than that of group B and shear bond strength of group C was significantly higher than that of group D. 2. Group C and D both had significantly higher shear bond strengths than metal bracket (group A), but there were no significant differences in shear bond strengths between group A and B (p < 0.05). 3. The failure sites of four bracket groups were also different. Group C and D failed primarily at enamel-adhesive interface, but group A and B failed primarily at bracket base-adhesive interface. 4. Among all ceramic bracket groups, group B was very similar to metal bracket in the aspect of shear bond strength and failure site.

  • PDF

IN VITRO MARGINAL FIT OF THE COMPUTERAIDED MILLED CERCON CROWNS

  • Chang, Jae-Yoon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.306-313
    • /
    • 2005
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But most of statistical inferences are not definite because of sample size, measurement number, measuring , instruments, etc. And there have been few studies about the marginal fit of Computer-aided Cercon crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made using computer-aided milled Cercon crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and methods. The in vitro marginal discrepancies of computer-aided milled Cercon crowns and control groups (metal ceramic crowns) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared by milling machine. 30 crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. The means and standard deviations of the marginal fit were 85$\pm$22$\mu$m for the control group and 91$\pm$15$\mu$m for the Cercon crowns. The t-test of the marginal discrepancies between Cercon crowns and metal-ceramic crowns were performed. Significant differences were not found between groups (P=0.230>.05). Based on the criterion of 120$\mu$m as the limit of clinical acceptability, the mean marginal fits of Cercon crowns and metal-ceramic crowns were acceptable. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were 85$\pm$22$\mu$m for the control (metal-ceramic crowns), 91$\pm$15$\mu$m for Cercon crowns. 2. The Cercon crowns showed slightly larger marginal gap discrepancy than the control but marginal gap between Computer-aided milled Cercon crowns and metal ceramic crowns did not showed significant difference (P>.05). 3. The Cercon crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

Modification of Poly(methylsilene) Catalyzed by Group 4 and 6 Transition Metal Complexes and Its Pyrolysis

  • 양수연;박종목;우희권;김환기;김동표;황택성
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.12
    • /
    • pp.1264-1268
    • /
    • 1997
  • The poly(methylsilene) (1) was modified with the group 4 metallocene Cp2MCl2/Red-Al (M = Ti, Zr, Hf) combination catalyst and with the group 6 metal carbonyl M(CO)6 (M = Cr, Mo, W) catalyst, producing the highly cross-linked isoluble polymer and the lowly cross-linked soluble polymer, respectively. An interrelationship between molecular weight and percent ceramic residue yield with metal within the respective group was not found. The polymers modified with the group 4 metallocene combination catalysts have higher molecular weight and lower percent ceramic residue yield than the polymers modified with the group 6 metal carbonyl catalysts do. The catalytic activity of group 4 metallocene combinations appears to be higher at ∼100 ℃, but to be lower at very high temperature than those of group 6 metal carbonyls. The pyrolysis of the modified 1 yielded SiC ceramic.

EFFECTS OF CHEMICALLY CURED RESIN AND LIGHT CURED RESIN ON SHEAR BOND STRENGTH OF METAL BRACKET AND CERAMIC BRACKET (화학중합형 및 광중합형 레진접착제가 금속 및 도재브라켓의 전단결합강도에 미치는 영향)

  • Yoon, Duk-Sang;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.125-134
    • /
    • 1994
  • This study was designed for comparison of shear bond strengths and failure patterns of four experimental groups which combinated mesh-backed metal brackets and texture based ceramic brackets (Transcend series $2000^{(TM)}$) with chemically cured resin (Mono $Lok2^{(TM)}$) and visible light cured resin $(Transbond^{(TM)})$. Brackets were bonded on the extracted human bicuspids, after etching them by manufacturer's recommand, and the shear bond strengths were measured on the Instron machine after 24 hrs passed in the $37^{\circ}C$ water bath. The results were as follows. 1. Ceramic brackets, transcend series $2000^{(TM)}$, bonded with $MonoLok2^{(TM)}$ showed statistically higher shear bond strength than mesh-backed metal brackets bonded with $MonoLok2^{(TM)}$. 2. There was no significant difference in shear bond strengths between metal and ceramic brackets bonded with $(Transbond^{(TM)})$. 3. Ceramic brackets bonded with both $(Transbond^{(TM)})$) and $MonoLok2^{(TM)}$ showed primarily fractures between brackets adhesive interface. 4. Enamel crack was not found in anyone specimen.

  • PDF

Combustion Characteristic and Stability of Flat Premixed Ceramic Burner with Different Porous Baffle Plates (평판 예혼합 세라믹 버너의 분포판 변화에 따른 연소화염특성과 안정성 분석)

  • Lee, Jae-Young;Lee, Pil-Hyong;Park, Chang-Soo;Park, Bong-Il;Hwang, Sang-Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.4
    • /
    • pp.7-16
    • /
    • 2009
  • Porous metal plates (Metal fiber, muti-hole metal plate) using mainly in surface burner are known to have a corrosion and durability problem under high temperature condition. In this study, premixed flat flame with perforated ceramic tile of more durable cordierite material was examined with respect to combustion stability and emission. The flat premixed ceramic burner consists of perforated ceramic tile and various type of baffle plates to form stable surface flame. The results show that most stable flat flame is generated using baffle plate with open ratio of 0.193. In downward flat flame mode which is widely used in condensing boiler, CO is measured below 50ppm from equivalence ratio 0.755 to 0.765 and $NO_X$ is measured below 12ppm from equivalence ratio 0.75 to 0.79. It is also found that the range of blue flame in flame stability curve becomes wider with increasing heat capacity.

  • PDF

A Study on the Mg-doped LAS Ceramics Using Metal Alkoxide (금속 알콕사이드를 이용한 Mg-doped LAS계 내열세라믹스의 제조 및 소결에 관한 연구)

  • 김영배;김형태;이응상
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.1
    • /
    • pp.45-50
    • /
    • 1995
  • In order to densify LAS(Lithuim Aluminosilicate)system compounds, we used metal alkoxides as precursors. Also Mg was added by sol-gel method using metal alkoxides to the LAS system for improving the sinterability, thermal and mechanical properties. The result was that the synthesizing temperature was lowered about 10$0^{\circ}C$, the sintering temperature was lowered by over 10$0^{\circ}C$ and MOR of samples from metal alkoxides was two times larger than that of sample form oxide.

  • PDF

Comparison of the Marginal Fitness of Ceramic Co-Cr Metal Crown (도재용 코발트-크롬 금속관의 변연적합도 비교)

  • Jeon, Byung-Wook;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: In this study, the marginal fitness of ceramic Co-Cr metal crown made by precision casting, milling, and selective laser melting method were compared. Methods: The ceramic Co-Cr metal crown manufactured by precision casting used the lost wax(LC specimen) method. The abutment were scanned and then made by milling(CM specimen), selective laser melting(CS specimen) method. The specimen were cut bucco-lingual and mesio-distal, and absolute marginal discrepancy and marginal gap were measured using a digital microscope. The surface roughness of the crown was also observed. Results: On the bucco-lingual axial, absolute marginal discrepancy was the LC specimen $31.72({\pm}4.58){\mu}m$, the CM specimen $78.29({\pm}3.28){\mu}m$ and the CS specimen $143.13({\pm}3.83){\mu}m$, respectively. On the bucco-lingual axial, marginal gap was the LC specimen $22.70({\pm}1.46){\mu}m$, the CM specimen $22.70({\pm}1.49){\mu}m$ and CS specimen $99.60({\pm}1.57){\mu}m$, respectively. Conclusion: For ceramic Co-Cr metal crowns, LC specimen was superior for absolute marginal discrepancy and marginal gap. The surface of metal crowns by selective laser melting were the roughest.

The Effect of Acid Treatment Time for Ni Plating on the Joint of α-Al2O3 and Ni Metal (α-Al2O3와 Ni 금속 접합을 위한 Ni 무전해 도금시 산처리의 영향)

  • YI, EUNJEONG;AN, YONGTAE;CHOI, BYUNGHYUN;JI, MIJUNG;HWANG, HAEJIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.306-310
    • /
    • 2016
  • In Na-base Battery for ESS, ${\alpha}-Al_2O_3$ and metal bonding was used to prevent direct reaction between electrolyte and electrode. The hard metal was metalized at $1600^{\circ}C$ in a flowing hydrogen gas for high bonding strength. In this study, instead of hard metal metalizing, Ni was plated on ${\alpha}-Al_2O_3$ by electroless Ni plating technique and then bonded with metal. To enhance the bonding strength, surface of ${\alpha}-Al_2O_3$ was treated with $H_3PO_4$. The effects of strength and leakage of joining as a function of acid treatment time on ${\alpha}-Al_2O_3$ are described.