• Title/Summary/Keyword: Central control system

Search Result 990, Processing Time 0.026 seconds

Design of FPGA in Power Control Unit for Control Rod Control System (원자로 제어봉 구동장치 제어시스템용 전력제어기 FPGA 설계)

  • Lee, Jong-Moo;Shin, Jong-Ryeol;Kim, Choon-Kyung;Park, Min-Kook;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.563-566
    • /
    • 2003
  • We have designed the power control unit which belongs to the power cabinet and controls the power supplied to Control Rod Drive Mechanism(CRDM) as a digital system based on Digital Signal Processor(DSP). The power control unit dualized as the form of Master/Slave has had its increased reality. The Central Process Unit(CPU) board of a power control unit possesses two Digital Signal Processors(DSPs) of the control DSP for performing the tasks of power control and system monitoring and the communication of the Control DSP and the Communication DSP. To accomplish the functions requested in the power control unit effectively, we have installed Field Programmable Gate Arrays(FPGAS) on the CPU board and have FPGAs perform the memory mapping, the generation of each chip selection signal, the giving and receiving of the signals between the power controllers dualized, the fault detection and the generation of the firing signals.

  • PDF

Design of Closed Loop Pipe Cooling System (냉각수 순환 형태의 파이프 쿨링 공법의 설계)

  • 박찬규;왕인수;구자중
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.52-57
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. The pipe cooling method leads to the decrease of curing period by lagging materials as well as the decrease of temperature difference between center and surface of mass concrete member, There are two methods in the pipe cooling system, which are open loop system and closed loop system. However open loop pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation in the central area of city, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance results of hydration heat control with closed loop pipe cooling system.

  • PDF

Embedded System for Automatic Condensation Control of the Car

  • Lee, Dmitriy;Bae, Yong-Wook;Lee, Neung-Ho;Seo, Hee-Don
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.21-27
    • /
    • 2012
  • In this study, we designed an embedded system for automatic condensation control(ESCC) of the car. This system heats the car glasses as and when it is needed that makes driving safer and convenient. The system was built on an ATmega128L central processing unit(CPU), using high-performance electrically erasable programmable read-only memory(EEPROM) complex programmable logic device(CPLD) ATF1504AS, using which an ESCC algorithm has been proposed. The source code was written in C language. The algorithm of work was written using the dew-point table. This system not only clears the condensation on the glass but also averts condensation. The designed ESCC system begins working once the input information comes close to the dew-point table information. This device enables a wider field of view, thereby increasing safety.

Development of a management control system for KODAS (KODAS 관리제어 시스템 개발)

  • Kim, K.H.;Nam, K.Y.;Kim, W.T.;Seo, J.I.;Ko, H.J.;Lee, J.K.;Yyun, T.Y.;Kim, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.424-426
    • /
    • 1993
  • Main function of distribution automation system can be summarized as feeder automation, telemetering, load control and facility information management. But in most cases, one or two of the above mentioned functions are developed in one distribution automation system. Which function to be developed in the automation system depends on the distribution system's characteristics. The title KODAS means $\underline{KO}$rea $\underline{D}$istribution $\underline{A}$utomation $\underline{S}$ystem. Management Korea for KODAS is central control station of distribution system, which is composed of several substations. This paper describes computer system, software tools, data base design data acqusition scheme and information flow.

  • PDF

A Study on the Decision Determination of Replenishment using Dynamic Approach in (1,m)Type Inventory System (DP법을 이용한 (1,m)형 재고시스템의 보충 의사결정에 관하여)

  • 이재원;이철영;조덕필
    • Journal of Korean Port Research
    • /
    • v.14 no.1
    • /
    • pp.37-45
    • /
    • 2000
  • Centralized safety stock in a periodic replenishment system which consists of one central warehouse and m regional warehouse can reduce backorders allocating the centralized safety stocks to regional warehouse in a certain instant of each replenishment cycle. If the central warehouse can not monitoring inventories in the regional warehouse, then we have to predetermine the instant of allocation according to demand distribution and this instant must be same for all different replenishment cycle. However, transition of inventory level in each cycle need not to be same, and therefore different instant of the allocation may results reduced shortage compare to the predetermined instant of allocation. In this research, we construct a dynamic model based on the assumption of monitoring inventories in the regional warehouse everyday, and develop an algorithm minimize shortage in each replenishment cycle using dynamic programming approach.

  • PDF

Review of the changes of proprioceptive sensory information (고유수용성 감각 정보의 변화에 관한 고찰)

  • Kang, Jong-Ho;Bang, Hyun-Soo;Kim, Jin-Sang
    • PNF and Movement
    • /
    • v.5 no.1
    • /
    • pp.19-28
    • /
    • 2007
  • Proprioception means the ability to perceive the sensation of position and movement of body. As it is transmitted to central nervous system and used in feed-back or feed-forward motor control, proprioception allows us to keep our normal movement and normal balance activity. However, the conditions such as injury, disease, aging and fatigue can damage the proprioceptiive sensation of position, movement and lead to a functional impairment and additional damages in musculoskeletal system, because they alter the amount of proprioceptive ability that transfer into the central nervous system. The purpose of this study was to identify the definition and the function of proprioception, to look into variations in injury, disease, aging and fatigue that can be easily met in clinical application and eventually to provide valuable aid for assessment and treatment.

  • PDF

Minimize Shortages in Two-Phase Periodic Replensihment System Using Dynamic Approach ((1, m)형 재고시스템에 의한 안전재고의 집중과 최적분배계획에 관한 연구)

  • 이재원;이철영;조덕필
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.83-90
    • /
    • 1999
  • Centralized safety stock in a periodic replenishment system which consists of one central warehouse and m regional warehouse can reduce backorders allocation the centralized safety stocks to regional warehouse in a certain instant of each replenishment cycle. If the central warehouse can not monitoring inventories in the regional warehouse, then we have to predetermine the instant of allocation according to demand distribution and this instant must be same for all different replenishment cycle. However, transition of inventory level in each cycle need not to be same, and therefore different instant of the allocation may results reduced shortage compare to the predetermined instant of allocation. In this research, we construct a dynamic model based on the assumption of monitoring inventories inventories in the regional warehouse everyday, and develop an algorithm minimize shortage in each replenishment cycle using dynamic programming approach.

Malignant Tumours of the Central Nervous System in Kazakhstan - Incidence Trends from 2004-2011

  • Igissinov, Nurbek;Akshulakov, Serik;Igissinov, Saginbek;Moore, Malcolm;Adilbekov, Yerzhan;Gaitova, Kamilla;Kissaev, Yermek;Mustafina, Meruert
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.7
    • /
    • pp.4181-4186
    • /
    • 2013
  • In the article were observed the epidemiological aspects of malignant tumors of the central nervous system (MT CNS) in Kazakhstan in a retrospective study for the years 2004-2011. The material of the study was consolidated accounting data of oncology centers on patients with MT CNS (C70-72) with first time established diagnosis. Calculated were crude, age, standardized (world standard), aligned and predicted incidence of MT CNS among both male and female populations. It was found that over the studied period, there were 4,604 cases of MT CNS. The average annual crude incidence rate of MT CNS in total population was $3.7{\pm}0.1^0/_{0000}$. Trends in aligned incidence rates in the whole country had a tendency to increase (T=+0.9%). Defined levels of morbidity MT CNS in the whole population in different regions of Kazakhstan: low up to $2.87^0/_{0000}$, the average from 2.87 to $4.45^0/_{0000}$ and high from $4.45^0/_{0000}$ and above on the basis of which was given the space-time estimate. Age and sex differences in MT CNS incidence were also clearly established.

Evaluation of Power Flow Control Strategy and DC-link Voltage Regulation for DC Microgrid

  • Nguyen, Thanh Van;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.416-417
    • /
    • 2019
  • In this paper, an effective power flow control strategy (PFCS) based on the centralized control approach and a DC-link (DCV) restoration algorithm for DC microgrid (DCMG) are presented. By investigating the statuses of system power units, eleven operating modes are given to ensure the system power balance under various conditions. To avoid the system power imbalance caused by the delay of grid fault detection, a reliable DCV restoration algorithm is proposed. In the proposed scheme, when an abnormal variation of the DCV is detected, the battery instantly starts a local emergency control mode to restore the DCV to the nominal value regardless of the control mode from the central controller. The simulations and experiments are carried out to prove the effectiveness of the PFCS and the proposed DCV restoration algorithm.

  • PDF

A Study on the Design and Performance Evaluation Technology of Fieldbus Pneumatic Solenoid Valve/Sensor System (필드버스 공압 솔레노이드 밸브/센서시스템 설계 및 성능평가 특성해석)

  • Kim, D.S.;Hong, C.P.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.865-870
    • /
    • 2001
  • For pneumatic system control, we need a data transmission system with high speed and high reliability or information interchange between main computer and solenoid valves and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid valves. In addition we developed a communication protocol for construction of RS-485 based multidrop network, and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. The field test results show that, even under high noise environment, the data transmission of 375Kbps rate is possible up to 1,000m without using repeater. In addition, the system developed in this research is proved to be used easily for extension of a communication network because of its module structure.

  • PDF