• Title/Summary/Keyword: Central X-ray

Search Result 271, Processing Time 0.026 seconds

The Relationship of the Filtration and the Side-scattered Dose in Verious Radiation Shielding Materials (방사선차폐물질(放射線遮蔽物質)에서 발생(發生)하는 측방산란선(側方散亂線)의 측정(測定))

  • Huh, Joon;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1984
  • Side-direction scattered dose from various radiation shielding materials was measured at 50cm distance from the central beam of primary ray by used several kinds of added filters for a x-ray deep therapeutic installation, the obtained results were as follows : 1. Dose rate by tube voltage was more increased at heavy filtration than light filtration. 2. Scattered doses produced by constant tube voltage in all shielding materials were decreased at heavier filtration. 3. Scattered doses produced by constant shielding material in all tube voltages were decreased at heavier filtration.

  • PDF

Hexaphenylbenzene $C_6(C_6H_5)_6$

  • Kim Young-Sang;Ko Jaejung;Kang Sang Ook;Han Won-Sik;Jeong Jae-Ho;Suh Il-Hwan
    • Korean Journal of Crystallography
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • The structure of the title compound has been determined by single-crystal X-ray diffraction work. The crystals are orthorhombic, space group $Pna2_1$ with a=11.095(3), b=21.834(7), c=12.574(4) $\AA$, and R1=0.0667. The average carbon bond length in aromaticity In the molecule is 1.386(1) $\AA$ and the average single bond length linking the central benEene ring and peripheral phenyl rings is 1.491(3) $\AA$. The average dihedral angle between the central benzene ring and each of six peripheral phenyl rings is $67.1(1)^{\circ}$ and the average dihedral angle between neighboring two phenyl rings is $55.0(1)^{\circ}$. Thus the molecule adopts a quasi-propeller configuration with approximate six-fold rotation symmetry.

A Study of Composite Laminates Containing a Central Hole (비균일 응력을 받고있는 중앙에 구멍이 있는 복합재 적층의 분석)

  • Kim, Hyung-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.212-216
    • /
    • 2007
  • Predicting microcracking properties of the composite laminates in nonuniform stress conditions was the subject in this paper. The uniform stress field meant the stresses were independent of the width direction. The material was the 954-2A/IM7 laminates containing a central hole. Microcracks initiated at the edge of the hole and propagated into the laminate. Because the tensile stress concentration decreased with distance, the microcracks were arrested before the edge of the laminate. Because carbon fiber composites were opaque, a x-ray method was used to detect the length of the propagating microcracks. The microcracking at the near edge of the hole could be reasonably predicted by considering the local laminate stresses and the microcracking toughness measured in unnotched laminates. However, the date away from the hole did not agree with the predictions. The local microcrack density was always much higher than that predicted by the local laminate stress.

  • PDF

Mediastinal Emphysema, Giant Bulla, and Pneumothorax Developed during the Course of COVID-19 Pneumonia

  • Ruihong Sun;Hongyuan Liu;Xiang Wang
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.541-544
    • /
    • 2020
  • The coronavirus disease 2019 (COVID-19) pneumonia is a recent outbreak in mainland China and has rapidly spread to multiple countries worldwide. Pulmonary parenchymal opacities are often observed during chest radiography. Currently, few cases have reported the complications of severe COVID-19 pneumonia. We report a case where serial follow-up chest computed tomography revealed progression of pulmonary lesions into confluent bilateral consolidation with lower lung predominance, thereby confirming COVID-19 pneumonia. Furthermore, complications such as mediastinal emphysema, giant bulla, and pneumothorax were also observed during the course of the disease.

Role of p53-dependent PI3K in Radioresistance of Colon Cancer Cells (대장암 세포의 방사선저항성에 대한 p53의존성 PI3K의 역할)

  • Lee, Heui-Kwan;Kim, Jong-Suk;Kwon, Hyoung-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.258-262
    • /
    • 2010
  • Radiotherapy is one of the major therapies for cancer treatment. p53 acts as a central mediator of the cellular response to stressful stimuli, such as radiation. Recently it has been known that activation of the phosphatidylinositol-3-kinase (PI3K) pathway is associated with radioresistance. In this study, we investigated whether X-irradiation up-regulates PI3K in a p53-dependent manner in human colon cancer cells. In order to study this phenomenon, we have treated p53-wild type and p53-mutant type HCT116 cells with X-ray. Treatment of wild type HCT116 cells with 8 Gy resulted in a marked increase in PI3K (p85), which paralleled an increase in PTEN, a counterpart of PI3K. However, these effects of X-rays in the p53-mutant cells were not observed. These results suggest that the X-irradiation-induced up-regulation of PI3K/PTEN pathway is p53-dependent.

Comparison of Beam Quality Index of High Photon Beam (고에너지 광자선의 선질 지표에 관한 비교)

  • 신동오;지영훈;박성용;박현주;김회남;홍성언;권수일;서태석;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.185-192
    • /
    • 1998
  • It is necessarily to evaluate the energy of X-ray emitted from linear accelerator in order to determine the accurate absorbed dose. The method of direct measurement for x-ray energy is very difficult and impractical. Therefore the method of using beam quality index is generally used. Several dosimetry protocols recommend the use of quality indices such as depth of dose maximum at radiation central axis, dose gradient, and dose level. The linear accelerator manufactures follow the recommendation as dosimetry protocols. The study was performed for us to select the most suitable parameter among the Quality indices as described above. For photon beams of 4, 6, 10, 15, and 21 MV nominal energies produced by four kinds of accelerators(Mitsubishi, Scanditronix, Siemens, Varian) in eleven institutions, We evaluated the x-ray energies obtained by the Quality indices as recommended by several dosimetry protocols and manufactures. Results showed that there were energy spreads according to the same accelerators and Quality indices even though nominal energies were same. It appeared that the percent depth dose at 10 cm (D$_{10}$(%)) gave the smallest deviation and spread of energies. As energies increased, the energy deviation increased for all the quality indices. It is desirable for the use of unified quality index to compare the evaluation of beam quality at different institutions.

  • PDF

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

Synthesis and Characterization of New Azomethine Polymers Containing Bent-Core Mesogen with Sharp Bend Angle

  • Kim, Eun-Chol;Choi, E-Joon;Ok, Chang-Woo;Zin, Wang-Choel
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.553-555
    • /
    • 2007
  • Six azomethine polymers containing bent-core mesogen were synthesized with variation of a bent structure of central core (1,2-dioxyphenylene or 2,3-dioxynaphthylene), and a lateral halogen substituent (X = H, F or Cl ). The properties of the polymers were characterized by FT-IR, NMR spectroscopy, DSC, polarizing optical microscopy, and X-ray diffractometry.

  • PDF

Micromorphology and Chemical Composition of a Sialolith in the Submandibular Gland Duct (악하선 내 타석의 미세형상 및 화학적 조성)

  • Im, Yeong-Gwan;Song, Ho-Jun;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.161-167
    • /
    • 2011
  • Sialolith is one of the most common pathologic conditions found in the salivary glands. The mechanisms responsible for the formation of sialoliths have not been elucidated so far. In this article, the chemical composition and micromorphology of a sialolith of a 58-year old female patient suffering from chronic sialoadenitis of the submandibular gland was analyzed using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). In a SEM evaluation, the highly mineralized amorphous core surrounded by lamellar and concentric structures was revealed, however no foreign body, organic material, or signs of microorganism were observed in the core of the sialolith. EDX analysis showed the central core was composed of only Ca, O and P, and that a high level of C was detected near the central area as well. These results indicated that the inorganic composition of the sialolith was hydroxyapatite crystals, and that inorganic and organic substances existed around the central cores. This study suggests that the sialolith was composed mainly of hydroxyapatite crystals and the formation of the nucleus of the sialolith in the submandibular gland duct was secondary to sialadenitis, which favors the growth of an inorganic crystalline nucleus.

Advanced Treatment Planning Method for Gamma Knife Radiosurgery of Cerebral Arteriovenous Malformations (뇌동정맥기형의 감마나이프 방사선 수술 -치료 계획 방법의 개선을 중심으로-)

  • Jang Geon-Ho;Lim Young Jin;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.87-94
    • /
    • 1995
  • Since March 1992, total 200 patients who visited our hospital as functional or organic lesions of central nervous system were treated by gamma knife stereotactic radiosurgery for 27 months. Thirty-nine patients of total cases was diagnosed as cerebral arteriovenous malformation. The rate of magnification on X-ray film was reduced by cutting fixation adaptor from 1.0 to below 1.45 times. In order to treat the deep- and lateral-seated cerebral arteriovenous malformation, we slightly modified the angiographic indicator, the commercial Leksell system, by cutting each inner sides about 5mm, We performed the more distinction of the scales by adapting 0.5mm or 1mm copper filter to angiographic indicator. The center point of indicator(X=100mm, Y=100mm, Z=100mm) is corrected by adjusting scales of X-, Y-, Z-axis to each inner 100 and outer 100 point within 1-2mm by repeated exposure of X-ray on films in trial-and-errors. We have developed the 'GKANGIO' programed as the Fortran-77 in Microvax - 3100, which can save treatment planning time and perform accurate pretreatment planning using the theoretical target metrix center. The theoretical description of the simplified method is presented for the reduction of experimental and numerical errors in treatment planning of radiosurgery.

  • PDF