• Title/Summary/Keyword: Center detection

Search Result 3,830, Processing Time 0.028 seconds

Financial Fraud Detection using Text Mining Analysis against Municipal Cybercriminality (지자체 사이버 공간 안전을 위한 금융사기 탐지 텍스트 마이닝 방법)

  • Choi, Sukjae;Lee, Jungwon;Kwon, Ohbyung
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.3
    • /
    • pp.119-138
    • /
    • 2017
  • Recently, SNS has become an important channel for marketing as well as personal communication. However, cybercrime has also evolved with the development of information and communication technology, and illegal advertising is distributed to SNS in large quantity. As a result, personal information is lost and even monetary damages occur more frequently. In this study, we propose a method to analyze which sentences and documents, which have been sent to the SNS, are related to financial fraud. First of all, as a conceptual framework, we developed a matrix of conceptual characteristics of cybercriminality on SNS and emergency management. We also suggested emergency management process which consists of Pre-Cybercriminality (e.g. risk identification) and Post-Cybercriminality steps. Among those we focused on risk identification in this paper. The main process consists of data collection, preprocessing and analysis. First, we selected two words 'daechul(loan)' and 'sachae(private loan)' as seed words and collected data with this word from SNS such as twitter. The collected data are given to the two researchers to decide whether they are related to the cybercriminality, particularly financial fraud, or not. Then we selected some of them as keywords if the vocabularies are related to the nominals and symbols. With the selected keywords, we searched and collected data from web materials such as twitter, news, blog, and more than 820,000 articles collected. The collected articles were refined through preprocessing and made into learning data. The preprocessing process is divided into performing morphological analysis step, removing stop words step, and selecting valid part-of-speech step. In the morphological analysis step, a complex sentence is transformed into some morpheme units to enable mechanical analysis. In the removing stop words step, non-lexical elements such as numbers, punctuation marks, and double spaces are removed from the text. In the step of selecting valid part-of-speech, only two kinds of nouns and symbols are considered. Since nouns could refer to things, the intent of message is expressed better than the other part-of-speech. Moreover, the more illegal the text is, the more frequently symbols are used. The selected data is given 'legal' or 'illegal'. To make the selected data as learning data through the preprocessing process, it is necessary to classify whether each data is legitimate or not. The processed data is then converted into Corpus type and Document-Term Matrix. Finally, the two types of 'legal' and 'illegal' files were mixed and randomly divided into learning data set and test data set. In this study, we set the learning data as 70% and the test data as 30%. SVM was used as the discrimination algorithm. Since SVM requires gamma and cost values as the main parameters, we set gamma as 0.5 and cost as 10, based on the optimal value function. The cost is set higher than general cases. To show the feasibility of the idea proposed in this paper, we compared the proposed method with MLE (Maximum Likelihood Estimation), Term Frequency, and Collective Intelligence method. Overall accuracy and was used as the metric. As a result, the overall accuracy of the proposed method was 92.41% of illegal loan advertisement and 77.75% of illegal visit sales, which is apparently superior to that of the Term Frequency, MLE, etc. Hence, the result suggests that the proposed method is valid and usable practically. In this paper, we propose a framework for crisis management caused by abnormalities of unstructured data sources such as SNS. We hope this study will contribute to the academia by identifying what to consider when applying the SVM-like discrimination algorithm to text analysis. Moreover, the study will also contribute to the practitioners in the field of brand management and opinion mining.

Diagnostic Evaluation of the BioFire® Meningitis/Encephalitis Panel: A Pilot Study Including Febrile Infants Younger than 90 Days (BioFire® Meningitis/Encephalitis Panel의 진단적 유용성 평가: 90일 미만 발열영아에서의 예비 연구)

  • Kim, Kyung Min;Park, Ji Young;Park, Kyoung Un;Sohn, Young Joo;Choi, Youn Young;Han, Mi Seon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.92-100
    • /
    • 2021
  • Purpose: Rapid detection of etiologic organisms is crucial for initiating appropriate therapy in patients with central nervous system (CNS) infection. This study aimed to evaluate the diagnostic value of the BioFire® Meningitis/Encephalitis (ME) panel in detecting etiologic organisms in cerebrospinal fluid (CSF) samples from febrile infants. Methods: CSF samples from infants aged <90 days who were evaluated for fever were collected between January 2016 and July 2019 at the Seoul National University Children's Hospital. We performed BioFire® ME panel testing of CSF samples that had been used for CSF analysis and conventional tests (bacterial culture, Xpert® enterovirus assay, and herpes simplex virus-1 and -2 polymerase chain reaction) and stored at -70℃ until further use. Results: In total, 72 (24 pathogen-identified and 48 pathogen-unidentified) CSF samples were included. Using BioFire® ME panel testing, 41 (85.4%) of the 48 pathogen-unidentified CSF samples yielded negative results and 22 (91.7%) of the 24 pathogen-identified CSF samples yielded the same results (enterovirus in 19, Streptococcus agalactiae in 2, and Streptococcus pneumoniae in 1) as those obtained using the conventional tests, thereby resulting in an overall agreement of 87.5% (63/72). Six of the 7 pathogen-unidentified samples were positive for human parechovirus (HPeV) via BioFire® ME panel testing. Conclusions: Compared with the currently available etiologic tests for CNS infection, BioFire® ME panel testing demonstrated a high agreement score for pathogen-identified samples and enabled HPeV detection in young infants. The clinical utility and cost-effectiveness of BioFire® ME panel testing in children must be evaluated for its wider application.

Multi-resolution SAR Image-based Agricultural Reservoir Monitoring (농업용 저수지 모니터링을 위한 다해상도 SAR 영상의 활용)

  • Lee, Seulchan;Jeong, Jaehwan;Oh, Seungcheol;Jeong, Hagyu;Choi, Minha
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.497-510
    • /
    • 2022
  • Agricultural reservoirs are essential structures for water supplies during dry period in the Korean peninsula, where water resources are temporally unequally distributed. For efficient water management, systematic and effective monitoring of medium-small reservoirs is required. Synthetic Aperture Radar (SAR) provides a way for continuous monitoring of those, with its capability of all-weather observation. This study aims to evaluate the applicability of SAR in monitoring medium-small reservoirs using Sentinel-1 (10 m resolution) and Capella X-SAR (1 m resolution), at Chari (CR), Galjeon (GJ), Dwitgol (DG) reservoirs located in Ulsan, Korea. Water detected results applying Z fuzzy function-based threshold (Z-thresh) and Chan-vese (CV), an object detection-based segmentation algorithm, are quantitatively evaluated using UAV-detected water boundary (UWB). Accuracy metrics from Z-thresh were 0.87, 0.89, 0.77 (at CR, GJ, DG, respectively) using Sentinel-1 and 0.78, 0.72, 0.81 using Capella, and improvements were observed when CV was applied (Sentinel-1: 0.94, 0.89, 0.84, Capella: 0.92, 0.89, 0.93). Boundaries of the waterbody detected from Capella agreed relatively well with UWB; however, false- and un-detections occurred from speckle noises, due to its high resolution. When masked with optical sensor-based supplementary images, improvements up to 13% were observed. More effective water resource management is expected to be possible with continuous monitoring of available water quantity, when more accurate and precise SAR-based water detection technique is developed.

Automated Analyses of Ground-Penetrating Radar Images to Determine Spatial Distribution of Buried Cultural Heritage (매장 문화재 공간 분포 결정을 위한 지하투과레이더 영상 분석 자동화 기법 탐색)

  • Kwon, Moonhee;Kim, Seung-Sep
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.551-561
    • /
    • 2022
  • Geophysical exploration methods are very useful for generating high-resolution images of underground structures, and such methods can be applied to investigation of buried cultural properties and for determining their exact locations. In this study, image feature extraction and image segmentation methods were applied to automatically distinguish the structures of buried relics from the high-resolution ground-penetrating radar (GPR) images obtained at the center of Silla Kingdom, Gyeongju, South Korea. The major purpose for image feature extraction analyses is identifying the circular features from building remains and the linear features from ancient roads and fences. Feature extraction is implemented by applying the Canny edge detection and Hough transform algorithms. We applied the Hough transforms to the edge image resulted from the Canny algorithm in order to determine the locations the target features. However, the Hough transform requires different parameter settings for each survey sector. As for image segmentation, we applied the connected element labeling algorithm and object-based image analysis using Orfeo Toolbox (OTB) in QGIS. The connected components labeled image shows the signals associated with the target buried relics are effectively connected and labeled. However, we often find multiple labels are assigned to a single structure on the given GPR data. Object-based image analysis was conducted by using a Large-Scale Mean-Shift (LSMS) image segmentation. In this analysis, a vector layer containing pixel values for each segmented polygon was estimated first and then used to build a train-validation dataset by assigning the polygons to one class associated with the buried relics and another class for the background field. With the Random Forest Classifier, we find that the polygons on the LSMS image segmentation layer can be successfully classified into the polygons of the buried relics and those of the background. Thus, we propose that these automatic classification methods applied to the GPR images of buried cultural heritage in this study can be useful to obtain consistent analyses results for planning excavation processes.

Multi-classification of Osteoporosis Grading Stages Using Abdominal Computed Tomography with Clinical Variables : Application of Deep Learning with a Convolutional Neural Network (멀티 모달리티 데이터 활용을 통한 골다공증 단계 다중 분류 시스템 개발: 합성곱 신경망 기반의 딥러닝 적용)

  • Tae Jun Ha;Hee Sang Kim;Seong Uk Kang;DooHee Lee;Woo Jin Kim;Ki Won Moon;Hyun-Soo Choi;Jeong Hyun Kim;Yoon Kim;So Hyeon Bak;Sang Won Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.187-201
    • /
    • 2024
  • Osteoporosis is a major health issue globally, often remaining undetected until a fracture occurs. To facilitate early detection, deep learning (DL) models were developed to classify osteoporosis using abdominal computed tomography (CT) scans. This study was conducted using retrospectively collected data from 3,012 contrast-enhanced abdominal CT scans. The DL models developed in this study were constructed for using image data, demographic/clinical information, and multi-modality data, respectively. Patients were categorized into the normal, osteopenia, and osteoporosis groups based on their T-scores, obtained from dual-energy X-ray absorptiometry, into normal, osteopenia, and osteoporosis groups. The models showed high accuracy and effectiveness, with the combined data model performing the best, achieving an area under the receiver operating characteristic curve of 0.94 and an accuracy of 0.80. The image-based model also performed well, while the demographic data model had lower accuracy and effectiveness. In addition, the DL model was interpreted by gradient-weighted class activation mapping (Grad-CAM) to highlight clinically relevant features in the images, revealing the femoral neck as a common site for fractures. The study shows that DL can accurately identify osteoporosis stages from clinical data, indicating the potential of abdominal CT scans in early osteoporosis detection and reducing fracture risks with prompt treatment.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Intracellular CD154 Expression Reflects Antigen-specific $CD8^+\;T$ Cells but Shows Less Sensitivity than Intracellular Cytokine and MHC Tetramer Staining

  • Han, Young-Woo;Aleyas, Abi G.;George, Junu A.;Yoon, Hyun-A;Lee, John-Hwa;Kim, Byung-Sam;Eo, Seong-Kug
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.12
    • /
    • pp.1955-1964
    • /
    • 2007
  • A recent report showed that analysis of CD154 expression in the presence of the secretion inhibitor Brefeldin A (Bref A) could be used to assess the entire repertoire of antigen-specific $CD4^+\;T$ helper cells. However, the capacity of intracellular CD154 expression to identify antigen-specific $CD8^+\;T$ cells has yet to be investigated. In this study, we compared the ability of intracellular CD154 expression to assess antigen-specific $CD8^+\;T$ cells with that of accepted standard assays, namely intracellular cytokine IFN-${\gamma}$ staining (ICS) and MHC class I tetramer staining. The detection of intracellular CD154 molecules in the presence of Bref A reflected the kinetic trend of antigen-specific $CD8^+\;T$ cell number, but unfortunately showed less sensitivity than ICS and tetramer staining. However, ICS levels peaked and saturated 8 h after antigenic stimulation in the presence of Bref A and then declined, whereas intracellular CD154 expression peaked by 8 h and maintained the saturated level up to 24 h post-stimulation. Moreover, intracellular CD154 expression in antigen-specific $CD8^+\;T$ cells developed in the absence of $CD4^+\;T$ cells changed little, whereas the number of IFN-${\gamma}$-producing $CD8^+\;T$ cells decreased abruptly. These results suggest that intracellular CD154 could aid the assessment of antigen-specific $CD8^+\;T$ cells, but does not have as much ability to identify heterogeneous $CD4^+\;T$ helper cells. Therefore, the combined analytical techniques of ICS and tetramer staining together with intracellular CD154 assays may be able to provide useful information on the accurate phenotype and functionality of antigen-specific $CD8^+\;T$ cells.

Identification of Hepatitis B (HBV) and C (HCV) Virus Infection among Doctors and Nurses in Tertiary Hospitals in Mongolia

  • Batbold, D.;Baigalmaa, Dovdon;Ganbaatar, B.;Chimedsuren, O.
    • Perspectives in Nursing Science
    • /
    • v.7 no.1
    • /
    • pp.50-54
    • /
    • 2010
  • The studies of M. Colombo (1989) and W. Lange (1992) showed that 30~40% of people became chronic after suffering from hepatitis B virus (HBV) and C virus (HCV) infection, and about 50% of the chronic cases transformed into primary liver cancer. There have been few studies done in Mongolia on hepatitis infection among health professionals, particularly in nurses. In a study done by Chimedsuren (8), the study showed that 19.4% of people with identified surface hepatitis B antigen (HBsAg) and antibodies to hepatitis C virus and 8% of people with the identified nucleotide of RNA for the hepatitis C virus (polymerase chain reaction) had an acute form of hepatitis C. Studies on the hepatitis virus genome damaging effect on liver cells showed that genotype 8 (A, B, C, D, E, F, G, TTV) had the most damaging effect on liver cells (Hahn and Faeka, 2007). Several studies have shown a relationship between hepatitis B virus infection and a lack of compliance regarding safety regulations and rules by medical personnel. Results of a study from the Maternal and Child Health Research Center showed that tests done to detect hepatitis B virus antigen and antibodies to C virus did not reveal anything. Both antigen and antibodies in 69% cases did not show, and separately, B virus and antibodies to hepatitis C virus were identified in 13% and 9%, respectively. Results of the tests taken from health personnel in Shastin Central Hospital showed that in 76% of the cases, the B virus antigen with C virus antibodies was not identified. In 8% of the cases, the B virus antigen was present on its own. The combination of B the virus antigen and C virus antibodies were present in 8% of nurses and doctors, respectively. 82% of the cases had negative results for the detection of a combination of B virus antigen and C virus antibodies taken from health personnel from the State Central Clinical Hospital whereas the B virus antigen and C virus antibodies by themselves were present in 7% and 14% of the cases, respectively. Combined cases of the B virus antigen and C virus antibodies were identified in 4% of the personnel. Results of the tests taken from the health personnel in the Hospital of the Ministry of Justice and Internal Affairs showed that in 79% of the cases, the B virus antigen with C virus antibodies were not identified. Separately, the B virus and antibodies to hepatitis C virus were identified in 8% and 13% of the cases, respectively.

  • PDF

Wideband Colpitts Voltage Controlled Oscillator with Nanosecond Startup Time and 28 % Tuning Bandwidth for Bubble-Type Motion Detector (나노초의 발진 기동 시간과 28 %의 튜닝 대역폭을 가지는 버블형 동작감지기용 광대역 콜피츠 전압제어발진기)

  • Shin, Im-Hyu;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1104-1112
    • /
    • 2013
  • This paper presents a wideband Colpitts voltage controlled oscillator(VCO) with nanosecond startup time and a center frequency of 8.35 GHz for a new bubble-type motion detector that has a bubble-layer detection zone at the specific distance from itself. The VCO circuit consists of two parts; one is a negative resistance part with a HEMT device and Colpitts feedback structure and the other is a resonator part with a varactor diode and shorted shunt microstrip line. The shorted shunt microstrip line and series capacitor are utilized to compensate for the input reactance of the packaged HEMT that changes from capacitive values to inductive values at 8.1 GHz due to parasitic package inductance. By tuning the feedback capacitors which determine negative resistance values, this paper also investigates startup time improvement with the negative resistance variation and tuning bandwidth improvement with the reactance slope variation of the negative resistance part. The VCO measurement shows the tuning bandwidth of 2.3 GHz(28 %), the output power of 4.1~7.5 dBm and the startup time of less than 2 nsec.

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber (국내외 상용 단일모드 광섬유의 감마선 영향 분석 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.564-567
    • /
    • 2012
  • Optical fibers are going to be used for telecommunication, image fibers, sensors under irradiation in nuclear power plants and various irradiation facilities. Especially, Temperature detection sensors using Raman light scattering, temperature or strain sensors using fiber gratings, magnet-optical sensors using photo-magnetic effect, are already commercialized. However, When fibers are exposed to ionizing radiation, color centers are formed in fibers which reduces their light transmission, and it is limited in applying under radiation environments. In this study, $Co^{60}$ gamma-ray induced optical attenuation on Ge-doped single mode(SM) fiber has been measured. Gamma-ray is irradiated for 4hours at the dose rate of 0.5kGy/hr, 2kGy/hr, 8kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur precisely. Furthermore, dose rate effect that the higher dose rate in the same total dose, the more increase loss of optical fiber and annealing effect that the higher the loss after irradiation, the more increase the recovery rate of the loss are observed in the fiber. This results plan to make use of bases in the study of the radiation-hardened optical fiber.

  • PDF